Loading...
HomeMy WebLinkAboutConstruction Drawings w m_ LEGEND _ — — — — PROPOSED BOUNDARY LINE CONSTRUCTION DRAWINGS FOR Q�oF`` �p\STERE,c�tiF�, O w R/W ROAD RIGHT-OF-WAY 8 56 I2 S UMBRIA HILLS WAY W FRANKLIN R s 05/08/24 0 J PROPOSED EASEMENT OF U �G C lolls PROPOSED SEWER MAIN A PORTION OF SECTION 15, vo F A Of TOWNSHIP 3 NORTH, RANGE 1 WEST, BOISE MERIDIAN � I � h, • W s w PROPOSED WATER MAIN CITY OF MERIDIAN, ADA COUNTY, IDAHO `n 2024 w M w w ry of w Q 12"SD PROPOSED STORM DRAIN LINE ABBREVIATIONS \ \ N X w _ w AD AREA DRAIN PRC POINT OF REVERSE CURVATURE w \\ /�� N 0 0 o z o w 4"PI PROPOSED PRESSURE IRRIGATION MAIN Q \\ Rp w z a z 0- Y 0 0 ARV AIR RELEASE VALVE PT POINT OF TANGENCY Z \\ �ti1G, -� 3 w o W v PROPOSED FLOW LINE > \\ C/y m w = U o BOW BACK OF WALK PVI POINT OF VERTICAL CURVATURE ❑ ❑ v Q U- Os PROPOSED SEWER MANHOLE CB CATCH BASIN ROW RIGHT OF WAY DEVELOPER 1� \\ VILLAGGIO WA o MERIDIAN STANDARD S SOUTH Q w w 0 s� PROPOSED STORM DRAIN MANHOLE MSS SPECIFICATIONS BALL VENTURES AHLQUIST m o E EAST/FASTING SB SEEPAGE BED 1144 S SILVERSTONE WAY U) PROJECTLOCATI N \\ z U) ® PROPOSED CATCH BASIN SD STORM DRAIN SUITE#500, MERIDIAN, ID 83642 - _ 2 EX EXISTING SUMBRIA HILLS WAY _ \\ INTERSTgTE --- W ® PROPOSED VALVE SDMH STORM DRAIN MANHOLE DEVELOPER CONTACT: — �wAY j_g4- __-----__— FF FINISHED FLOOR HIG a ®B.O. PROPOSED BLOW-OFF FL FLOWLINE SGT SAND/GREASE TRAP KOREY HALL _ SL STREET LIGHT ®ARV 208-401-5501 PROPOSED AIR RELEASE VALVE GIRR GRAVITY IRRIGATION SS or SSWR SANITARY SEWER HP HIGH POINT is PROPOSED IRRIGATION SERVICE INV INVERT SSMH SANITARY SEWER MANHOLE U_ PROPOSED SIGN SSCO SANITARY SEWER CLEAN OUT z LP LOW POINT Z O LL SUB SUBDIVISION O_ 0 PROPOSED TYPE II BARRICADE N NORTH/NORTHING w TOA TOP OF ASPHALT - - > U a ME MATCH EXISTING wLL j w U) PROPOSED TYPE III BARRICADE TOC TOP OF CONCRETE ❑ PC POINT OF CURVATURE PROPOSED PED RAMP PERF PERFORATED TRC TOP OF ROLLED CURB VICINITY MAP = TVC TOP OF VERTICAL CURB SCALE: 1"=1300' 2580 PROPOSED MAJOR CONTOUR PI PRESSURE IRRIGATION W WEST PO PUMP OUT 0 100 200 400 600 U) 2582 PROPOSED MINOR CONTOUR Z F-H / 2580 _ _ i EXISTING MAJOR CONTOUR Z 0 EXISTING MINOR CONTOUR \��' I BM#1 I4 j Sheet List Table \\ \\ I AI/% e i C0.00 COVER 100 � \\ \\ I I MC C0.01 NOTES V W \ \ U 'yO,Qq \ , - Q �� C2.00 EXISTING CONDTIONS&DEMO \ J / O o \� \ z � C3.00 UMBRIA HILLS WAY ROAD PLAN&PROFILE � c w 0 = a \ C3.01 UMBRIA HILLS WAY ROAD PLAN&PROFILE o m r Z ( \ `\ W I /� \ Z C3.02 INTERSECTION DETAILS 0 d \ \ U) w m a — — — — — — — — — — Iv \ C3.03 INTERSECTION DETAILS N z Cie I? — — — — — — — — _ — _ _ — — — — — — \� \\ BM#3 C3.04 UMBRIA HILLS WAY SWALE STATIONS M Mir C o — C3.05 DETAILS � o W VILLAGGIO WAY (PUBLIC)—f—�— _ — — — N O I C4.00 UMBRIA HILLS WAY SEWER PLAN&PROFILE `\ \\ BM#2 C4.01 UMBRIA HILLS WAY SEWER PLAN&PROFILE Il C6.00 UMBRIA HILLS WAY SIGNING AND STRIPING PLAN C7.00 UMBRIA HILLS WAY STREETLIGHT PLAN O I I \�i2 Q ui U) ` ec `\ a \\ `\ cn w oQ \ d9 `\ I O o w l I \ L.L `\ ` U) a I � pI \ ` w Z U) Q \ \ J Q I I z w U- I \ `\ O Q > ryN nI N N — ` ` z w -- _— — — W - - _ l U 1-84 - ♦' _ � I U Z w CALL BEFORE YOU DIG! NOTICE TO CONTRACTORS CALL DIGLINE INC. UTILITY REPRESENTATIVES U) CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH z PRIOR TO COMMENCING GENERALLY ACCEPTED CONSTRUCTION PRACTICES,CONSTRUCTION UTILITY AGENCY PHONE aUNDERGROUND WORK CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE DIAL: 811 RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF ADA COUNTY HIGHWAY CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL ROADS DISTRICT (208)387-6287 = PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE w Z NOTE: MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL SURVEY INFORMATION COMMUNICATIONS CABLE ONE (208)472-8409 co — THE LOCATION OF EXISTING UNDERGROUND WORKING HOURS,AND CONSTRUCTION CONTRACTOR FURTHER co Q_ UTILITIES ARE SHOWN APPROXIMATELY ONLY AGREES TO DEFEND, INDEMNIFY AND HOLD THE ADA COUNTY CONSTRUCTION STAKING WILL BE PROVIDED BY T-O ENGINEERS-ROB O'MALLEY,PLS PHONE NO.(208)-442-6300 COMMUNICATIONS CENTURYLINK (208)385-2144 Z PRIOR TO CONSTRUCTION. IT SHALL BE THE HIGHWAY DISTRICT,THE CITY OF MERIDIAN,AND THE DESIGN O CONSULTANT HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALL ELEVATIONS SHOWN ARE NORTH AMERICAN VERTICAL DATUM OF 1988(NAVD 88). ATTENTION: o RESPONSIBILITY OF THE CONTRACTOR TO INFORM ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON PUBLIC WORKS CITY OF MERIDIAN PUBLIC (208)985-1211 0 1/2 1 (� ALL UTILITY COMPANIES OF THE CONSTRUCTION BM#1 BM#2 BM#3 WORKS o Q THIS PROJECT. CITY OF MERIDIAN STREET IF THIS BAR DOES NOT MEASURE SCHEDULE. THE CONTRACTOR SHALL DETERMINE (IfTHE EXACT LOCATION OF ALL EXISTING UTILITIES UNAUTHORIZED CHANGES & USES: THE DESIGN CONSULTANT NORTHING: 704949.463 NORTHING: 704514.044 NORTHING: 704531.477 STREET LIGHTS LIGHTS (208)489-0352 1"ON 22x34 SHEET or 1/2" ON Z BEFORE COMMENCING WORK. THE CONTRACTOR PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR 1lxl7 SHEET,THEN DRAWING IS FASTING: 2443753.577 EASTING: 2442592.308 EASTING: 2441270.993 p IS RESPONSIBLE FOR ANY AND ALL DAMAGE LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE POWER IDAHO POWER (208)388-6510 NOT TO SCALE co w WHICH MAY OCCUR BY FAILURE TO EXACTLY PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST ELEVATION: 2576.902 ELEVATION: 2564.582 ELEVATION: 2563.844 w Q DATE: April 29,2024 _ LOCATE AND PROTECT ALL UTILITIES. BE APPROVED BY THE PREPARER OF THESE PLANS. DESCRIPTION: 5/8"W/CAP DESCRIPTION: 5/8"W/CAP DESCRIPTION: 5/8"BAR GAS INTERMOUNTAIN GAS (208)377-6863 a N PROJECT: 240076 Q O o' O SHEET: 0 0 N_ J 0 H SS\ON A L £NC m GENERAL CONSTRUCTION NOTES SEWER NOTES ACHD ROADWAY NOTES `��' pST RF 'tip O 1. ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT VERSION OF THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION 1. CONSTRUCTION OF THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE WASTEWATER RULES(IDAPA 58.01.16)AS WELL AS THE STANDARDS 1. THE ENGINEER SHALL COMPLY WITH ACHD POLICY SECTION 3100-CERTIFICATION OF COMPLIANCE WITH DESIGN STANDARDS.THE FOLLOWING w (ISPWC),THE CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC(AND ANY ADDENDUMS),MERIDIAN DESIGN STANDARDS,THE AND SPECIFICATIONS REFERRED TO IN GENERAL CONSTRUCTION NOTE NO. 1. STANDARD NOTE SHALL BE INSERTED ON THE TITLE SHEET OF ALL PLANS SUBMITTED FOR ACHD REVIEW AND APPROVAL: 8 5 6 a REQUIREMENTS OF THE ADA COUNTY HIGHWAY DISTRICT(ACHD),AND/OR THE REQUIREMENTS OF THE IDAHO TRANSPORTATION DEPARTMENT(ITD).THE s MORE STRINGENT OF ANY OF THESE STANDARDS SHALL BE THE CONTROLLING STANDARDS OR SPECIFICATIONS. 2. THE CONTRACTOR SHALL CONSTRUCT THE SANITARY SEWER IN ACCORDANCE WITH THE STAMPED PLANS APPROVED BY THE MERIDIAN CITY PUBLIC WORKS THE ENGINEER OF RECORD CERTIFIES THAT THE PLANS ARE PREPARED INSUBSTANTIAL CONFORMANCE WITH THE ACHD POLICY AND STANDARDS IN � 05/08/24�0 J DEPARTMENT.THESE PLANS WILL BE PROVIDED TO THE CONTRACTOR BY THE PROJECT INSPECTOR PRIOR TO CONSTRUCTION.WORK SHALL NOT BE DONE EFFECT AT THE TIME OF PREPARATION.THE ENGINEER ACKNOWLEDGES THAT ACHD ASSUMES NO LIABILITY FOR ERRORS OR DEFICIENCIES IN THE v qTF \O U y Q 2. THE CONTRACTOR SHALL HAVE A COPY OF THE LATEST CITY OF MERIDIAN STANDARD SPECIFICATIONS AND DRAWINGS ON SITE OR READILY ACCESSIBLE AT WITHOUT THE CURRENT SET OF APPROVED PLANS. DESIGN.ALL VARIANCES FROM ACHD POLICY SHALL BE APPROVED IN WRITING.THE FOLLOWING VARIANCES, LISTED BY DATE AND SHORT O N OF � ALL TIMES DURING CONSTRUCTION(AVAILABLE ON THE WEBSITE). FAILURE TO HAVE ACCESS TO A CURRENT COPY OF THE STANDARD SPECIFICATIONS ON DESCRIPTION,WERE APPROVED FOR THE PROJECT:02/28/23-APPROVAL FOR GRAVITY IRRIGATION DRAIN TO BE LOCATED WITHIN ACHD EASEMENT G. CARP SITE COULD BE GROUNDS FOR A STOP WORK ORDER UNTIL THE SITUATION IS RESOLVED. 3. FINAL APPROVAL AND ACCEPTANCE OF ALL SEWER CONSTRUCTION WILL BE BY THE MERIDIAN PUBLIC WORKS DEPARTMENT. (UNDER ACHD SIDEWALK). (n 4. SEWER INSPECTIONS WILL BE BY THE MERIDIAN PUBLIC WORKS DEPARTMENT AND THEIR DECISIONS SHOULD BE CONSIDERED AS FINAL.THE CONTRACTOR 2. ALL CONSTRUCTION IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO THE CURRENT EDITION OF THE ISPWC AND THE ACHD SUPPLEMENTAL ry of 3. THE CONTRACTOR SHALL HAVE PLANS STAMPED"APPROVED FOR CONSTRUCTION"BY THE CITY OF MERIDIAN ON SITE AT ALL TIMES. WILL NOTIFY THE MERIDIAN PUBLIC WORKS DEPARTMENT 48 HOURS PRIOR TO CONSTRUCTION. MERIDIAN CITY WILL PROVIDE PERIODIC INSPECTIONS FOR AN SPECIFICATIONS.THERE SHALL BE NO EXCEPTIONS TO DISTRICT POLICY,STANDARDS,AND THE ISPWC ALLOWED UNLESS SPECIFICALLY AND N M w w w EIGHT-HOUR DAY, FROM 8:00 A.M.TO 5:00 P.M.,FOR A FORTY HOUR WEEK.THE CONTRACTOR SHALL REIMBURSE THE CITY AT RATES ESTABLISHED BY THE PREVIOUSLY APPROVED IN WRITING BY THE DISTRICT. U) N ❑ U U ❑ Z CITY FOR INSPECTION IN EXCESS OF THE NORMAL WORK WEEK, INCLUDING LEGAL HOLIDAYS.OVERTIME INSPECTION RATES AND A LIST OF LEGAL HOLIDAYS `� w ~ ~ ww z > a Q 4. ALL CONTRACTORS,SUBCONTRACTORS,AND UTILITY CONTRACTORS SHALL ATTEND A PRE-CONSTRUCTION CONFERENCE PRIOR TO START OF WORK. CAN BE OBTAINED FROM THE MERIDIAN PUBLIC WORKS DEPARTMENT. 3. ALL ROADWAY CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE APPROVED CONSTRUCTION PLANS. 2 a 3 a w of W v U Q5. CONTRACTORS SHALL NOTIFY THE APPROPRIATE AGENCY WHEN MATERIALS ARE ON SITE OR INSPECTION OF THE WORK IS REQUIRED.NO WORK MAY BEGIN 5. SEWER CONSTRUCTION WILL MEET SPECIFIC DETAILS AND REQUIREMENTS OF THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION INCLUDING 4. SET THE TOPS OF ALL VALVE BOXES AND SEWER MANHOLES FLUSH WITH THE SLOPE OF THE FINISHED STREET GRADES. m o � a ON ANY PROJECT WITHOUT TWENTY-FOUR(24)HOUR PRIOR NOTICE. MERIDIAN CITY REVISIONS.MERIDIAN CITY REVISIONS TO THE ISPWC STANDARD DRAWINGS ARE AVAILABLE ONLINE. Li_ ON PLACE ALL WATER VALVES, BLOW-OFFS,AND MANHOLES SO THAT THEY DO NOT CONFLICT WITH ANY CONCRETE CURB AND GUTTER,VALLEY GUTTER, 0 6. GROUNDWATER LEVELS SHALL BE MAINTAINED BELOW THE BOTTOM OF THE TRENCH DURING THE PIPE LAYING AND PIPE JOINING OPERATIONS.ALL OR SIDEWALK IMPROVEMENTS. w Z 6. CONTACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS PRIOR TO THE REQUIRED TESTING. THE CONTRACTOR MAY NOT OPEN OR CLOSE MANHOLES LOCATED WITHIN LIMITS OF SEASONAL GROUNDWATER SHALL HAVE THE EXTERIOR OF ALL CONCRETE SURFACES COATED WITH TWO COATS OF Q 0 WATER VALVES. COAL TAR EPDXY. 6. STANDARD 5"THICK CONCRETE SIDEWALK SHALL BE CONSTRUCTED AT LOCATIONS SHOWN ON THE PLANS AND PER THE ACHD SUPPLEMENTAL TO THE p (n ISPWC STD.DWG.NO.SD-709. 7. SERVICE LINES SHALL BE MARKED IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARD DRAWING SD 512.SERVICE LINE MARKERS SHALL REMAIN IN 7. ALL MATERIAL FURNISHED ON,OR FOR THE PROJECT MUST MEET THE MINIMUM REQUIREMENTS OF THE APPROVING AGENCIES.AT THE REQUEST OF THE PLACE DURING CONSTRUCTION AND BE PRESENT FOR FINAL INSPECTION.ON LOTS WHERE ROOF DRAINS ARE UTILIZED,THE CONTRACTOR SHALL COLOR 7. CONCRETE CONSTRUCTION SHALL CONFORM TO ISPWC.SECTION 706 WITH CLASS 30 MPa(4000 PSI)CONCRETE. cr_ APPROVING AGENCY OR THE DESIGN ENGINEER,CONTRACTORS SHALL FURNISH PROOF THAT ALL MATERIALS INSTALLED ON THIS PROJECT MEET THE THE ROOF DRAIN MARKERS TO CLEARLY DIFFERENTIATE ROOF DRAIN MARKERS FROM SEWER SERVICE MARKERS. W SPECIFICATION REQUIREMENTS SET FORTH IN GENERAL CONSTRUCTION NOTE NO. 1. 8. PERMANENT PAVEMENT MARKINGS SHALL CONFORM TO ISPWC.SECTION 1104. PAVEMENT MARKING SHALL ALSO MEET THE MANUAL ON UNIFORM a 8. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS(SANITARY SEWER,STORM DRAIN,AND IRRIGATION)SHALL BE A TRAFFIC CONTROL DEVICES FOR STREET AND HIGHWAYS. z 8. WORK SUBJECT TO APPROVAL BY ANY GOVERNMENTAL AGENCY MUST BE APPROVED PRIOR TO(A)BACKFILLING TRENCHES FOR PIPE;(B)PLACING OF MINIMUM OF TEN(10)FEET.WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN AGGREGATE BASE;(C)PLACING OF CONCRETE;(D)PLACING OF ASPHALT PAVING. (18)INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC 9. PAVEMENT SECTION SUBBASE SHALL BE 6-INCH PITRUN SAND AND GRAVEL AT THE THICKNESS SPECIFIED ON THE PLANS AND CONFORM TO THE ISPWC H DRINKING WATER SYSTEMS(IDAPA 58.01.08)AND SECTION 430.02 OF THE WASTEWATER RULES(IDAPA 58.01.16). SECTION 801. 9. INSPECTION,APPROVAL AND FINAL ACCEPTANCE OF ALL WATER AND SEWER CONSTRUCTION SHALL BE BY THE PUBLIC WORKS DEPARTMENT,AND THEIR 9. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX(6)FEET. 10. PAVEMENT SECTION BASE COURSE SHALL BE 3/4-INCH MINUS,CRUSHED SAND AND GRAVEL,AT THE THICKNESS SPECIFIED ON THE PLANS AND DECISION SHALL BE FINAL.SUCH INSPECTIONS SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PERFORMING THE WORK IN AN WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN(18)INCHES OF VERTICAL CONFORM TO THE ISPWC SECTION 802. Cn z U ACCEPTABLE MANNER IN ACCORDANCE WITH THE DEQ/QLPE APPROVED CONSTRUCTION PLANS. SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS z 0 LL (IDAPA 58.01.08)AND SECTION 430.02 OF THE WASTEWATER RULES(IDAPA 58.01.16) 11. PLANT MIX ASPHALT CONCRETE SHALL BE AT THE THICKNESS SPECIFIED ON THE PLANS AND CONFORM TO A SUPERPAVE PLANT MIX ASPHALT PER U SECTION 814 OF THE ACHD SUPPLEMENTAL TO THE ISPWC. W 10. ANY DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS MUST HAVE THE APPLICABLE AGENCY APPROVAL IN WRITING PRIOR TO CONSTRUCTION. > U a 10. THE CONTRACTOR SHALL PROVIDE MERIDIAN CITY'S INSPECTOR WITH"CUT SHEETS"FOR THE STAKING PROVIDED FOR CONSTRUCTION OF THE SANITARY W w U) SEWER."CUT SHEETS"SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION.ADDITIONALLY,TEMPORARY BENCH MARKS MUST BE PROVIDED TO THE 12. LOCAL RESIDENTIAL ROADWAYS AND ALLEYS SHALL BE A SP-3.0.50 INCH(1/2")MIX,PG 58-28 TWO AND A HALF INCHES(2.5")THICK,AS A MINIMUM WITH 4" ❑ 11. PRIOR TO BEGINNING INSTALLATION OF STREET LIGHTS,THE ELECTRICAL CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT FROM THE BUILDING MERIDIAN PUBLIC WORKS DEPARTMENT, INSPECTION SECTION PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. OF 3/4"BASE AND 14"OF 6"MINUS PIT RUN. USE WHICHEVER PAVEMENT SECTION IS GREATER. DIVISION OF THE MERIDIAN PUBLIC WORKS DEPARTMENT.ANY DEVIATION IN STREET LIGHT LOCATIONS FROM THE APPROVED PLANS MUST BE APPROVED IN O WRITING FROM THE CITY ENGINEER. 11. PRIOR TO CONSTRUCTION,TEMPORARY BENCH MARKS(TBM'S)SHALL BE SET IN THE FIELD BY A LICENSED SURVEYOR OR ENGINEER AND SHALL BE FLAGGED 13. MINOR ARTERIAL ROADWAYS SHALL BE SP-3,0.50 INCH(1/2")MIX, PG 64-28 FIVE INCHES(5")THICK,AS A MINIMUM WITH 4"OF%"BASE AND 25"OF 6" 2 AND CLEARLY VISIBLE FROM ALL DIRECTIONS.A TBM SHALL BE LOCATED WITHIN 100 FEET OF THE TIE-IN TO EXISTING SEWER AND SPACED NO GREATER THAN MINUS PIT RUN H 12. ALL REFERENCE MADE TO THE ISPWC SHALL REFER TO THE CURRENT EDITION.THE CONTRACTOR SHALL HAVE AT LEAST ONE(1)COPY OF THE ISPWC 500 FEET ALONG THE SEWER ALIGNMENT THEREAFTER.TBM'S SHALL HAVE ELEVATIONS TIED TO THE NAVD 1988 DATUM. ON-SITE FOR REFERENCE AT ALL TIMES DURING CONSTRUCTION. 14. ACTUAL FIELD CONDITIONS DURING TRENCHING MAY REQUIRE ADDITIONAL PAVEMENT REPAIR BEYOND THE LIMITS SHOWN ON THE PLANS.THE 07 12. SEWER PIPE WITH COVER OF GREATER THAN 3 FEET,SHALL BE BELL AND SPIGOT,POLYVINYL CHLORIDE(PVC),SDR 35,ASTM D3034 FOR 4-INCH THROUGH FOLLOWING CONDITIONS ARE LISTED IN SECTION 6000 OF THE ACHD POLICY MANUAL. 15-INCH AND ASTM F679 FOR 18-INCH THROUGH 27-INCH AS SET FORTH BY THE MERIDIAN CITY PUBLIC WORKS DEPARTMENT.SEWER PIPE WITH LESS THAN 3 Z 13. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY.THE CONTRACTOR SHALL DETERMINE THE EXACT FEET OF COVER SHALL BE DUCTILE IRON CONFORMING TO ANSI A-21.51 OR AWWA C-151 MINIMUM CLASS 50.A RUBBER RING IS TO BE INSTALLED WHERE THE A.ALL ASPHALT MATCH LINES FOR PAVEMENT REPAIR SHALL BE PARALLEL TO THE CENTERLINE OF THE STREET AND INCLUDE ANY AREA DAMAGED HLOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK.THE CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ANY AND ALL DAMAGES CAUSED PIPE IS IN CONTACT WITH THE MANHOLE BASE AND/OR ITS CHANNEL IN ORDER TO ENSURE A WATER-TIGHT SEAL. BY EQUIPMENT DURING TRENCHING OPERATIONS. z BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. 0 13. THE SEWER CONTRACTOR SHALL SUPPLY ALL LID ASSEMBLIES AND THE REQUIRED NUMBER OF RISER AND GRADE RINGS.THE SEWER CONTRACTOR SHALL B. IF THE CUMULATIVE DAMAGED PAVEMENT AREA EXCEEDS 50%OF THE TOTAL ROAD SURFACE,CONTRACTOR SHALL REPLACE THE ENTIRE ROAD z U 14. ONLY PLAN SETS STAMPED"APPROVED FOR CONSTRUCTION"AND SIGNED BY THE CITY ENGINEER OR HIS AUTHORIZED REPRESENTATIVE SHALL BE USED FIELD VERIFY THE ELEVATION OF THE TOP OF THE MANHOLE CONE TO ASSURE THAT RING ELEVATIONS MATCH FINAL STREET GRADES.THE MAXIMUM HEIGHT SURFACE. U) BY THE PROJECT CONTRACTOR(S). USE OF ANY PLANS ON THE JOB WITHOUT THE"APPROVED FOR CONSTRUCTION"STAMP SHALL BE GROUNDS FOR THE OF THE GRADE RINGS SHALL BE SUCH THAT THE FINISHED GRADE ELEVATION OF THE MANHOLE FRAME AND COVER SHALL NOT BE MORE THAN TWENTY-ONE I- ISSUANCE OF A STOP WORK ORDER. (21")INCHES ABOVE THE TOP OF THE MANHOLE CONE. C.CONTRACTOR SHALL REPLACE THE PAVEMENT SURFACE TO ENSURE MATCH LINE DOE NOT FALL WITHIN WHEEL PATH OF A LANE.MATCH LINE SHALL ONLY FALL IN THE CENTER OR EDGE OF A TRAVEL LANE. � O 15. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO PRIVATE OR PUBLIC PROPERTY AND SHALL RESTORE ALL SURFACES TO A CONDITION EQUAL TO 14. THE PAVING CONTRACTOR SHALL SET THE GRADE RINGS AND POUR THE CONCRETE COLLARS PER STANDARD DRAWING NO.SD 508.THE PAVING 00 � OR BETTER THAN EXISTED PRIOR TO CONSTRUCTION. CONTRACTOR SHALL CONTACT ACHD 24 HOURS PRIOR TO POURING CONCRETE COLLARS. D. PLOWABLE FILL OR IMPORTED MATERIAL MAY BE REQUIRED IF THE NATIVE TRENCH MATERIAL IS DEEMED UNSUITABLE BY ACHD INSPECTOR,DOES C� Z NOT MEET COMPACTION STANDARDS OR TIME IS A CRITICAL FACTOR. W 15. THE TRENCH BACKFILL ABOVE THE PIPE ZONE WILL BE INSPECTED BY THE ACHD OR BY THE DEVELOPER'S ENGINEER IN ACCORDANCE WITH THE LATEST Q �- 16. THE CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF FEDERAL,STATE AND LOCAL AUTHORITIES AND REGULATIONS ADOPTED THEREUNDER, 3: 00 m WITH REGARD TO TEMPORARY POLLUTION AND EROSION CONTROL MEASURES DURING CONSTRUCTION. EDITION OF THE"CONSTRUCTION QUALITY ASSURANCE MANUAL".COMPACTION TESTS ARE REQUIRED ON THE BACKFILL ABOVE THE PIPE ZONE,WITHIN E.ANY EXCEPTIONS TO THESE RULES SHALL BE PRE-APPROVED IN WRITING BY DISTRICT STAFF BEFORE CONSTRUCTION BEGINS. w M o PUBLIC RIGHT-OF-WAY.TESTING SHALL BE CONDUCTED TO MEET ALL ACHD REQUIREMENTS AND THE RESULTS SHALL BE SUBMITTED TO MERIDIAN PUBLIC � = Q WORKS DEPARTMENT AND ACHD PRIOR TO FINAL ACCEPTANCE. 17. THE CONTRACTOR SHALL COMPLY WITH ALL PERTINENT FEDERAL,STATE,AND LOCAL AGENCIES WHICH HAVE JURISDICTION OVER DUST CONTROL o a z PROCEDURES AND ADDITIVES USED IN DUST ABATEMENT. 16. THE MERIDIAN PUBLIC WORKS DEPARTMENT MAY TEST THE COMPACTION OF THE SEWER PIPELINE BEDDING.TESTING WILL BE DONE BY AN INDEPENDENT 0 Q 3:TESTING LABORATORY.THE COST OF THE FIRST TEST WILL BE PAID BY THE MERIDIAN PUBLIC WORKS DEPARTMENT. IF THE FIRST TEST FAILS TO MEET - U) 18. ALL CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE SAFETY LAWS OF ANY REQUIRED COMPACTION,ALL RE-TESTING SHALL BE PAID BY THE SEWER CONTRACTOR.THE CONTRACTOR SHALL CONTACT THE MERIDIAN PUBLIC WORKS z a M = JURISDICTIONAL BODY.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BARRICADES,SAFETY DEVICES AND CONTROL OF TRAFFIC WITHIN AND AROUND DEPARTMENT AND/OR TESTING LABORATORY TO SCHEDULE THE TESTS PRIOR TO ANY PIPE LAYING AND BACKFILLING. Cie cm z co M THE CONSTRUCTION AREA. M v U- 17. THE CONTRACTOR SHALL LEAVE THE EXCAVATION FOR THE UPSTREAM END OF ALL SERVICE LINES OPEN FOR FIELD VERIFICATION OF THE INVERT ELEVATION 0 BY THE CITY'S INSPECTOR.THE CONTRACTOR SHALL NOT BACKFILL THE ENDS OF SERVICE LINES UNTIL HE HAS OBTAINED APPROVAL FROM MERIDIAN CITY'S o z 19. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY CONSTRUCTION PERMITS PRIOR TO START OF WORK. INSPECTOR OR MADE OTHER ARRANGEMENTS FOR THE VERIFICATION OF SERVICE LINE INVERT ELEVATIONS. *14 04 O H 20. ALL CONSTRUCTION WITHIN THE PROJECT BOUNDARIES SHALL COMPLY WITH THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT, UNIFORM 18. PRIOR TO FINAL ACCEPTANCE,AFTER ALL UTILITIES ARE IN AND PRIOR TO PAVING,AN AIR TEST SHALL BE CONDUCTED.THE CONTRACTOR SHALL CONTACT U BUILDING CODE,CITY OF MERIDIAN CODE,AND ALL APPLICABLE COUNTY,STATE,AND FEDERAL CODES AND REGULATION. THE CITY OF MERIDIAN A MINIMUM OF 24 HOURS PRIOR TO TESTING.ALL MANHOLES SHALL BE TESTED IN ACCORDANCE WITH THE ISPWC AND MERIDIAN CITY'S MODIFICATIONS. u- 21. WORK SUBJECT TO APPROVAL BY ANY AGENCY MUST BE APPROVED PRIOR TO(A)BACKFILLING TRENCHES FOR PIPE;(B)PLACING OF AGGREGATE BASE;(C) 0 PLACING OF CONCRETE;(D)PLACING OF ASPHALT PAVING.WORK DONE WITHOUT SUCH APPROVAL DOES NOT RELIEVE THE CONTRACTOR FROM THE 19. THE SEWER MAIN SHALL BE TESTED FOR DEFLECTION IN ACCORDANCE WITH THE ISPWC AND MERIDIAN CITY'S MODIFICATIONS.ALL SEWER LINES SHALL BE O RESPONSIBILITY OF PERFORMING THE WORK IN AN ACCEPTABLE MANNER. TELEVISED WITH A CLOSED CIRCUIT TELEVISION CAMERA IN ACCORDANCE WITH THE ISPWC AND MERIDIAN CITY'S MODIFICATIONS.NO STANDING WATER 2 SHALL BE PRESENT. 0Y 22. THE CONTRACTOR SHALL KEEP ON SITE AT ALL TIMES A COPY OF THE APPROVED CONSTRUCTION PLANS ON WHICH IS RECORDED THE ACTUAL LOCATIONS 0 OF THE CONSTRUCTED PIPELINES AND ANY OTHER UTILITIES ENCOUNTERED.THE CONTRACTOR SHALL PROVIDE THESE LOCATIONS TO THE DESIGN 20. PLACE SEWER SERVICE LINES IN A SIX E INCH DIAMETER WATER CLASS PIPE SLEEVE WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT W ENGINEER FOR USE IN THE PRODUCTION OF RECORD DRAWINGS. FACILITY(I.E.,SEEPAGE BEDS,DRAINAGE SWALES). U) Z) W 23. CONTRACTOR SHALL OBTAIN AN EROSION AND SEDIMENT CONTROL PERMIT FROM THE CITY OF MERIDIAN A MINIMUM OF 72 HOURS PRIOR TO ANY WORK ON-SITE. GRADING & DRAINAGE NOTES z O 24. CONSTRUCTION DEWATERING, IF REQUIRED,SHALL COMPLY WITH ISPWC.SECTION 205.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF 1. THE CONTRACTOR SHALL CONTACT DIGLINE 48 HOURS PRIOR TO ANY EXCAVATION. 1-800-342-1585 OR 811. I1/ �- SEDIMENT DEPOSITED AS A RESULT OF DEWATERING ACTIVITIES. IF THE PROJECT WILL GENERATE CONSTRUCTION WASTEWATER THAT DISCHARGES TO O U STATE OR FEDERAL WATERS,A SHORT TERM ACTIVITY EXEMPTION FROM DEQ OR EQUIVALENT SHALL BE OBTAINED BY THE CONTRACTOR. 2. WHERE IT IS NOT SPECIFICALLY STATED IN THESE SPECIFICATION THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION SHALL GOVERN. 25. TRENCH EXCAVATION,BEDDING,AND BACKFILL SHALL CONFORM TO THE ISPWC.DIVISION 300.BEDDING SHALL BE A CLASS A-1 BEDDING SYSTEM. IF SOFT, 3. ALL EXISTING ORGANIC AND/OR DISTURBED SOILS, IF ENCOUNTERED,SHALL BE REMOVED TO DEPTHS OF 1-FOOT(MINIMUM),AND STOCKPILED FOR LATER LL UNSTABLE,OR UNSUITABLE TRENCH BOTTOM MATERIAL IS ENCOUNTERED, PIPE BEDDING SHALL BE TYPE II PER ISPWC.SECTION 304.BACKFILL SHALL USE. U) d COMPLY WITH ISPWC.SECTION 306 FOR TYPE A BACKFILL AND TYPE A-1 COMPACTION.W 4. STOCKPILE EXCAVATED LANDSCAPE FILL MATERIALS AND STRUCTURAL FILL MATERIAL SEPARATELY WITHOUT INTERMIXING.PLACE,GRADE,AND SHAPE V 26. CONTRACTOR SHALL RETAIN AN INDEPENDENT TESTING LABORATORY FOR FIELD QUALITY CONTROL OF ALL BACKFILL AND ASPHALT.FIELD QUALITY STOCKPILES TO DRAIN SURFACE WATER. Z U) ZCONTROL SHALL BE IN ACCORDANCE WITH ISPWC.SECTION 204.3.4 AND SECTION 810.3.13.COPIES OF ALL TEST RESULTS SHALL BE PROVIDED TO THE CITY 5. ALLOW AN INDEPENDENT QUALIFIED TESTING AGENCY TO INSPECT AND TEST SUBGRADES AND EACH FILL OR BACKFILL LAYER.PROCEED WITH Q OF MERIDIAN FOR REVIEW. SUBSEQUENT EARTHWORK ONLY AFTER TEST RESULTS FOR PREVIOUSLY COMPLETED WORK COMPLY WITH REQUIREMENTS. J 27. ALL UNSUITABLE MATERIAL SUCH AS SOILS,TRASH,AND VEGETATION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND PROPERLY DISPOSED OF 6. WHEN TESTING AGENCY REPORTS THAT SUBGRADES,FILLS,OR BACKFILLS HAVE NOT ACHIEVED DEGREE OF COMPACTION SPECIFIED,SCARIFY AND < J OFF SITE. MOISTEN OR AERATE,OR REMOVE AND REPLACE SOIL TO DEPTH REQUIRED;RECOMPACT AND RETEST UNTIL SPECIFIED COMPACTION IS OBTAINED D WITHOUT ADDITIONAL COMPENSATION. Q ^ 28. THE CONTRACTOR SHALL OBTAIN AND HAVE ON SITE AT ALL TIME A COPY OF THE GEOTECHNICAL REPORT BY GEOTEK, INC DATED JANUARY 20,2020. W Q7. CONTRACTOR SHALL VERIFY ALL EXISTING ELEVATIONS NOTED ON THIS PLAN AND NOTIFY DESIGN ENGINEER WHEN ELEVATIONS DO NOT MATCH PLANS. 7 O29. THE CONTRACTOR SHALL COMPLY WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL SOILS REPORT PREPARED BY GEOTEK, INC JANUARY 20,2020. 8. WASTE SOIL SHALL BE HAULED TO AN OFFSITE DISPOSAL SITE FURNISHED BY THE CONTRACTOR. O Q 30. ALL MATERIALS AND FINISHES SHALL BE AS PER DRAWINGS.DETAILS AND SPECIFICATIONS.CONTRACTOR IS RESPONSIBLE FOR DETERMINING ANY AND ALL 9. ALL FINISHED GRADES SHALL BE SMOOTH AND UNIFORM. ry O N ORDERING LEAD TIMES,AND PROVIDING REQUIRED MATERIALS AT THE PROJECT SITE IN A TIMELY MANNER. NO UNAPPROVED SUBSTITUTIONS WILL BE 1 ALLOWED.CONTACT THE LANDSCAPE ARCHITECT IMMEDIATELY IF A SPECIFIED MATERIAL IS NOT AVAILABLE. 10. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS.PROVIDE POSITIVE DRAINAGE TO ALL CATCH BASINS,DRAINAGE STRUCTURES,CURB CUTS,AND a DRAINAGE WINDOWS. o O 31. ALL WORK IS TO BE PERFORMED BY LICENSED CONTRACTORS AND EXPERIENCED WORKERS. w 11. ALL CONCRETE SIDEWALKS SHALL HAVE A MINIMUM OF ONE PERCENT(1%)CROSS SLOPE UNLESS OTHERWISE NOTED. H zz Q_ 32. IF ANY ARCHAEOLOGICAL,CULTURAL OR HISTORICAL RESOURCES,OR ARTIFACTS OR OTHER FEATURES ARE DISCOVERED DURING THE COURSE OF . CONTRACTOR SHALL COORDINATE CONNECTION OF ALL ROOF DRAIN DOWN SPOUTS AND BUILDING PLUMBING.SEE ARCHITECTURAL AND MECHANICAL V J CONSTRUCTION ANYWHERE ON THE PROJECT SITE,WORK SHALL BE SUSPENDED IN THAT LOCATION UNTIL A QUALIFIED PROFESSIONAL ARCHAEOLOGIST �^ w = DRAWINGS FOR EXACT LOCATION OF DRAINAGE CONNECTION POINTS. 7 o H ASSESSES THE SIGNIFICANCE OF THE DISCOVERY. L > 13. ALL CHANGES REQUIRE APPROVAL BY THE DESIGN ENGINEER. O '^ < 33. UPON COMPLETION OF ALL WORK THE CONTRACTOR SHALL CLEAN THE ENTIRE CONSTRUCTION SITE.FINAL CLEAN UP SHALL CONSIST OF REMOVAL OF ALL v J Z CONSTRUCTION DEBRIS,TRASH, REMAINING CONSTRUCTION STAKES,CONSTRUCTION SIGNS, ETC.FROM THE SITE.THE CONTRACTOR SHALL SWEEP ALL 14. ALL NON GRATED STORM DRAIN MANHOLE COVERS SHALL BE MARKED"STORM DRAIN". U W SIDEWALKS AND STREETS AS NECESSARY TO REMOVE ANY SOIL, ROCKS,GRAVEL OR OTHER MATERIALS.THE CONTRACTOR SHALL CLEAN ALL CATCH g BASINS AND MANHOLES REMOVING ANY SAND,DIRT,GRAVEL OR DEBRIS. 15. CONCRETE COLLARS SHALL BE POURED AT ALL STORM DRAINAGE INLETS AND MANHOLES.COLLARS SHALL BE PLACED IN ACCORDANCE WITH ISPWC w j SD-616. U F_ o z 16. PIPE TRENCH SHALL CONFORM TO DIVISION 300 OF THE LATEST EDITION OF THE ISPWC AND SD-301.BEDDING AND BACKFILL SHALL BE CONSTRUCTED PER WATER NOTES SECTIONS 305 AND 306 OF THE ISPWC. co 1. CONSTRUCTION OF THE WATER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE"IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS(IDAPA 58.01.08)" 17. PIPE LENGTHS SHOWN ARE NOT EXACT.ACTUAL INSTALLATION LENGTHS MAY VARY SLIGHTLY.LENGTHS ARE SHOWN FOR GENERAL INFORMATION ONLY. = AS WELL AS THE STANDARDS AND SPECIFICATIONS REFERRED TO IN GENERAL ~ CONSTRUCTION NOTE NO. 1. 18. ALL PROPOSED STORM DRAINAGE CATCH BASIN INLETS AND MANHOLES SHALL BE COVERED WITH FILTER FABRIC BY THE STORM DRAIN CONTRACTOR TO g U PREVENT CONTAMINATION OF STORM DRAINAGE FACILITIES. FABRIC SHALL NOT BE REMOVED UNTIL AFTER CONSTRUCTION IS COMPLETE AND LANDSCAPE co Z 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS(SANITARY SEWER,STORM DRAIN,AND IRRIGATION)SHALL BE A AREAS HAVE MATURED. MINIMUM OF TEN(10)FEET.WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN z (18)INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC 19. CARE SHALL BE TAKEN TO PREVENT DIRT AND OTHER SUPERFLUOUS MATERIALS FROM ENTERING STORM DRAINAGE FACILITIES DURING CONSTRUCTION. DRINKING WATER SYSTEMS(IDAPA 58.01.08)AND SECTION 430.02 OF THE WASTEWATER RULES(IDAPA 58.01.16). ATTENTION: o cr_ 20. FOR ANY DRAINAGE FACILITIES WITHIN A PUBLIC RIGHT OF WAY,ACHD OR ITD SHALL BE RESPONSIBLE FOR INSPECTION. FOR ANY PRIVATE DRAINAGE 0 1/2 1 z 0 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX(6)FEET. FACILITIES THE PROJECT ENGINEER OR ARCHITECT SHALL BE RESPONSIBLE FOR INSPECTION AND CERTIFICATION OF DRAINAGE FACILITIES; HOWEVER ° WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN(18)INCHES OF VERTICAL ANY ROOF DRAINAGE AND PIPING TO THE DRAINAGE FACILITIES WILL BE INSPECTED BY THE MERIDIAN PLUMBING OFFICIAL UNDER THE APPROPRIATE SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS PERMIT. IF THIS BAR DOES NOT MEASURE (IDAPA 58.01.08)AND SECTION 430.02 OF THE WASTEWATER RULES(IDAPA 58.01.16). 1"ON 22x34 SHEET or 1/2" ON z 11x17 SHEET,THEN DRAWING IS 9 cl 4. PLACE WATER SERVICE LINES IN A TWO(2)INCH DIAMETER PIPE SLEEVE WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY(I.E. NOT TO SCALE U) SEEPAGE BEDS,DRAINAGE SWALES). Q DATE: April 29,2024 a N 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONTINUOUS WATER SERVICE TO ALL EXISTING WATER USERS AFFECTED BY CONSTRUCTION. IF PROJECT: 240076 O WATER SERVICE MUST BE INTERRUPTED,THE CONTRACTOR SHALL COORDINATE WITH THE PUBLIC WORKS INSPECTOR. o O SHEET: Co.0 1) 0 0 N_ J 0 tw_- gS�ON A L £N LEGEND LEGEND NOTE: w0 30 60 120 180 8 56 a — — — — EXISTING BOUNDARY LINE so EXISTING STORM DRAIN MANHOLE 1. ABANDONED BUILDINGS,TEST PITS OR WATERWAYS LOCATED WITHIN CURRENT OR FUTURE RIGHT-OF-WAY SHALL BE RE-EXCAVATED TO NATIVE SOIL AND BACKFILLED WITH STRUCTURAL FILL J'j 05/08/24 0 J PER ISPWC SPECIFICATIONS. PROVIDE SOILS DATA TO VERIFY NATIVE MATERIAL MEETS THE F- R/W ROAD RIGHT-OF-WAY ® EXISTING CATCH BASIN REQUIREMENTS FOR ENGINEERED FILL PER ISPWC SPECIFICATIONS AND A COPY OF THE v0, F OF 0 COMPACTION TESTS. NG• CAR?F'� — — — SECTION LINE ® EXISTING VALVE W 2. THE EXISTING SURFACE SHOWN IN THESE DRAWINGS ARE FROM THE ORIGINAL SURVEY BEFORE ANY SITE WORK BEGAN.THE SURFACE HAS CHANGED SINCE THEN,AND THEREFORE SHOULD EASEMENT LINE ®B.O. EXISTING BLOW-OFF ONLY BE USED AS A GENERAL REFERENCE AND NOT FOR CONSTRUCTION PURPOSES. w M w w Q�Q w SEW EXISTING SEWER MAIN EXISTING SIGN N Lu o � Z w w z a z 0- p oo 0 W EXSITIGN WATER MAIN EXISTING STREETLIGHT m w v v Q Q � -i W U a U- SD EXISTING STORM DRAIN LINE EXISTING TYPE II BARRICADE O z O PI EXISTING PRESSURE IRRIGATION MAIN u EXISTING TYPE III BARRICADE W W EXISTING STORM DRAIN FLOW LINE EXISTING MAJOR CONTOUR 2 w EXISTING SEWER MANHOLE ,- EXISTING MINOR CONTOUR 0- - z W H U / I I\1 I I� 1 I I \\ I I I I I I j II I I I I z o LL v I `� \\\ 1 I / \ i I 1 J I I I I I I I L w I I I I 1 I I I I I /� I I Ilil o O I I I 111'IIII / I RETAIN AND PROTECT EXIST I I I ING IRRIGATION DITCH RETAIN AND PROTECT EXISTING IRRIGATION f / 1 I I IIII I STRUCTURES O I{- I I /��� v I _N_ I ` III I W /I �I ► I } 1� I � I II I � � � I i \ EXISTING SEPTIC TANK � I I I II I \ TO BE REMOVED . I I I I I / / EXISTING WELL TO BE ` e O I I i t I I I \ ABANDONED PER } EXISTING IRRIGATION \ \ IDWR REQUIREMENTS ce Q 00 �i DITCH TO BE REMOVED \ 1 j/ 'I I w (D O I II I I Ir / I O If - AND BACKFILLED PER 1 ! 0: W GEOTECH REPORT \ I I 2 = Q � Qo I REMOVE CONCRETE EX ST NG W T IN BOUNDS OF I X I \ `ct) I I l I I I I I I I I I p PROJECT GRADING AND ` I 1 1 z Q M II I II I } IIIIII I / 1 Cie DISPOSE OF OFF SITE I \ I I I M z co I 1 v O I I II }I111�1 / �� 1 ° I \I I o ° N O I � III I ° IIIIII I / 1 " a I I I I I I I I I I I 0 STRUCTURES AND CONCRETE G I IIIIIIII \ I /� I \ PADS TO BE REMOVED I I l _ � _ IIIIII � 1 ► / 1 � � \ I I REMOVE EXISTING CONCRETE \ \ \ IIIIII \ \ 1 I I n AND DISPOSE OF OFF SITELL I \ I EXISTING IRRIGATION I I' d 1 i IIIIIIII \ \ I I / v \ Cb / DITCH TO BE REMOVED W I III \ AND BACKFILLED PER V II \I II I I I I \ \\ \\ I I GEOTECH REPORT I I I II � z Q 4; 1111 II EXISTING GRAVITY IRRIGATION \ \ I I / //� / I / I I I I I I i I �06/� STRUCTURES AND PIPES TO BE I, RETAINED AND PROTECTED. \ \ I /j / / I I I I I I Q J I "lll��l — � I _ I . � Q I � / � PROPOSED S UMBRIA HILLS WAY \\L } W VILLAGIO I WAY UTILITIES HAVE NOT N I < I BEEN INSTALLED AT THE TIME OF THESE N } I I PLANS.OBTAIN THE MOST RECENT W \ \ / I I C0 z F_ I 0 I VILLAGGIO WAY PLANS FOR REFERENCE. \ 1 I / / Nti� I I I C0 I I l/ g WILLIAMS GAS / LL v m O 0 O I I IIIIII 1 / \\ / I / / �. PIPELINE EASEMENT \ // \\ I I w J III r _ CC / °= G I. / \ �G / II I Z z I � IIIIII 1 1 I � ` / i— I I - - - - - - - - - - - - - -J- � � G%� / /� / 1 / 1 / II I z Z_ I �^ REMOVE EXISTING TYPE III BARRICADE � _ I I 24"GAS MAIN I / � I- I z LLI I i� / J 12"W 12"W 12W / g I I ca Z) T I— — + - PROPOSED S UMBRIA HILLS WAY 7 ` \ I ( // // 22"GAS MAIN 10"S 1 lolls �..s �••� I / 1 w N III J cc) a O I I I I I I 1 :..:s: ..> I I // // ATTENTION: ry z CG I // I IF THIS BAR DOES NOT MEASURE G / I 1"ON 22x34 SHEET or 1/2" ON 11 x1 7 SHEET,THEN DRAWING IS p 11 I 1 \ :>. I I / / I I NOT TO SCALE w ` DATE: April 29,2024 a N I I I \ I I / G / PROJECT: 240076 G / SHEET: 0 O N_ O J 0 m Sc KEYNOTES F� ir ST RE,c�ti aC01 PEDESTRIAN RAMP AND TACTILE WARNING SURFACE PER ACHD SUPPLEMENTAL SD-712 8 56 05/08/24 0 J I CO2 4'VALLEY GUTTER PER ACHD SD-708OF Of v qTF �pQ� ,1 II l II •'I �'y'� I �yN�. CA RP���� ;I I CO3 SHALLOW INLET PER ACHD SD-715 cn / II A II Ilr I Il 11 11 I I Q I I III I �j III / OMBRIA HILLS wA P'�, I "- X C06 INSTALL(4)4"CONDUITS w ry of ❑ = ❑ II II I I INTERSECTIO Y N U U LU Z�S� 6 I s w N z a a 0 o > w II l I I II I E I III A / SHEET C3.02 ������� G3�2 B I x C07 INSTALL(4)6"CONDUITS Z 0- z 0- w U 0 o II IIIII IIII�'•t��: I III I. = I / e 5 c O ❑ 11 II I IIII'' I III 1 A U U CO3 a PERMANENT ACHD EASEMENT ��� 5� v'.\ s m w = a 2'BEHIND SIDEWALK FSEE 5�� CO3 �� °o�� C08 LANDSCAPE BERM UPHILL OF CATCH BASIN,SEE DETAIL 2 SHEET C3.04 ❑ ❑ Q o I / I I I IIII �I I I co3 o g / U U A J a s� N� s ox z I r N M o a Ii CO3 U o �oorn L _O �jI�� co °' �, " O o J a a I x� x� O� L��s�;�, U) II 1! I W V cV CO N O Co N O J O N r (n I I cv aNi` " (ri Lf+j <° ) A O rn N in `o 0 o cfl v " N ^ U B I �� o �G 6 C\\ O�`s6 _ I , (h O N N I ` O ((j O C^O +O I\ (V (\/ !- U _ �� �iJ 6\ J III IIII I IIII I 11 N o + "' M a Co3 L �� 2. ?' + COO •N N II Q U O O O r" M _ N '� + ^+ '� - a ~ tS C� Cs 6\OQ u? 69 ... N 11 11 0 a A s a 0 � s NOTES: It 11 11 N Q U h O I O "I' �-' N N N ^ CO,� CO J J d I O. t3%CO •p J (.l V' h 11 + W (O (0 (O n II 11 II 11 \\ tS 6 I NN N ; U COf-�N N N N Q j FQ ;- N N N o o N o _ CO3 ��r� �6 J� �' 1. CURB RETURN RADII ARE 20'TO BACK OF CURB UNLESS OTHERWISE NOTED.ALL ACCESSIBLE I I I I N p CO Co N I- II II 11 11 h (� I (() / s Cp < �` W II 11 III j (,.(n 11 11 Cp II 11 N N CO O COO t O ~ '- IQ U IQ U .6 OJ M O O Q U A J (S 6 a III I IIII N (" c� 11 11 N c� c6 m I " " coo I a Cog �� sj ��9 �2 �'ti�c ROUTES TO MEET CURRENT ADA GUIDELINES.ACHD WILL CHECK CROSS SLOPES AND RUNNING I „ II Q t 11 11 N N N N ` N `, .-, v �- O y yo d)- U;\ SLOPES AFTER CONCRETE IS POURED.ANY SLOPES EXCEEDING ALLOWABLE MINIMUMS OR W II III I II III ` ., �' U �' u j �.� � Q �j Q V 26 I N M M rn iv ci_ _ o _ -� o a CO3 \� J /\t<J y MAXIMUMS WILL BE REMOVED AND REPLACED AT THE EXPENSE OF THE CONTRACTOR. I I ±- �- r j j I c+° r� r"o N �° o co o N J io Ox �L °p C\� X CONTRACTOR SHALL VERIFY SLOPES DURING STRINGLINE/FORM PROCESS. MAXIMUM CROSS H I I I I Z f- C06 �.. _ ..,- . II I I I s r' / SLOPE 1.75/o. MAXIMUM RUNNING SLOPE OF 4.75/o. ~ II III IIII n `' ' � ,NO � �,\ �� peso o ° + co I „ „ N N c\4 K 1� o o o � -t �O \N O� \� 0 O � 11 N c\j N N 00 � � n � � N sO.�s6 d,`r6 x00 t�� O II III I I II I I Q v i� �_ ci U , cI'> 1 N (v s / j 12 31 �r 2. CONTRACTOR TO COORDINATE DRY UTILITY SERVICES WITH APPLICABLE UTILITY PROVIDERS. I I I �- 1- c/) I- (n + o N N ' o� + I",tS , O, )7 �S rn Z U I I W °j LID ,I " 6S N w Ln �� ��,,_< � \NW Z O_ I >- III W W ___ 25+00 12"W N N_Q U N N n/ J 3. SEE SHEETS C3.02 THROUGH C3.03 FOR DETAILED INTERSECTION GRADING. Q II � ILL 2566 � ZI 11 11 1- �-+ m_ u u N /..'...: ' A ��P` O � I II I I I W 12„w co1 ' Q U ' "rn �.� 7s CoW II I 11 I III II IIV U �'- - I 26+00 1 _~ ~ 6 a `' J� 4. SEE SHEETS C3.04 THROUGH C3.05 FOR STORM DRAINAGE SWALE DETAILS. � I r ID III II I � III I � l- I I � 0.48°�= CO2 •�' ;. • , _ ,.„ a r _, ., /r,::> := � °�g� � ' ��j 5. SEE SHEETS C4.00 THROUGH C4.01 FOR UTILITY PLAN AND PROFILES. � ❑ J IIII l I III✓ I 10"S _- S U 27+00 R30'• �CO2 f:E% - //�\,°j`��/ 6. SEE SHEETS C6.00 FOR SIGNING AND STRIPING PLANS. � UMBRIA TYP. <"<._ R200 � � �/ x O o III/ HILLS waY _ �_ _ ox°° /� 'j, �` so o� II III( I _ n', o 7. SEE SHEETS C7.00 FOR STREETLIGHT PLANS. I I _ 1 I o o rn . �� 28+00 �6a 0' �\ U-)05 20-U v .:._ a _.•... . . y._. 0.48% Z TYP. �\ u'Ox`S6d, \�O�s6 �OxsOcPdQ � O i CV" ,I = o o C07 „ (; (o a R15' 29+00 1 ~o. \��s0/ x d O O Od, Op II I a J I I (V > �' 'd a l� + U N U cow .coo M o C01 R15' cp c' s a w ; II�1� III ✓' N .�t O CV >N to z _ N I o � � ;:;..�: . s � o � FLOW LEGEND L II p I 1 I I I j I 11 N Lo I- _� ~M jj'p h O II 2 (O CO •- ' •.e TYP. CP •`JcS: �iA /•Q z I III I �, ,� I ,� 00 M 6 U o N o ; N_� _ OL I II 1 I II Ifs c) " _2 >CO U C3.05 0 11 _(..) O rr•.::.r<:t , U III l r I I M + M� +� �- I o U Q CO y' C06 �� CO3 25 YR PEAK 100 YR PEAK 11 I I I i v� o Z o a a o Urn _ _ N�G > O\ y FLOW(CFS) FLOW(CFS) 1 I I CO3 O N N o CO p � II I l !-I I 1 N N Q � �h � a � " . ��,q 30 �� n���\ems J B II III III ,lY I Q Q N o 11 No � v) CO �o N _:A N ` Os I I A c" 1- �- u) c4 It co U uD n N: �, u� o C06 - _ f i s \ c' x W OA 0.0-0.1 0.0-0.1 d I I 11 N U V .- 11 O N ^.r d' '' - 'a: .:J (A ._',• ($\ I I I I Q N ` (\i (o N_ - o \\ CA Ox 00 O II III I f/r I I U � n 2 � �_ ^MN.�� �M � � � �=U N I CO3 Q mo ` ~M�v U o) 6 m o U ma o o U co ^_� 2�Dn - OU, / o� O III III �- �- _ a a N o (n N s w' O C I B 0.0-0.1 0.1-0.2 ` co + a o� �N ❑ _ r.�� a d o_ i G Nj C) o co:. d co nn + n N v + O COO '�O 1� ^ W U iz U M N N COc" cp• N rn O'� N -y�\ -9 Z II IIII I IIII••] I A I N N Fr � �U � � > 11 0 ��` \\ 11 d 1- O (V U h U O 11 � N O 11 Lf) ,� „ - N 00 1 t9/ (P (Y) \\ \` lJ tS ts� 1 } o + co h o o c" (\i co o U o (o cS cr'cDs • N + Cp f, O N O O '��-n N Lo I- U " O N O U-O II O bp W II III I II I I I 11 CO N Q + a ° N' �' (O ca N. �- o o U o > o n . U o C3.05 o o rn Ep OO C 0.1 0.2 0.1 0.2 Q 00 I I J I PERMANENT ACHD EASEMENT I Q c" n �- (O 00 ; " 11 `p c\' w °' o > Lo 1- co U c" > 00 > � cn cp x cY� O �o �' °° M N I- N U c"o cO rn I, ~ o �- + > '- " h 90 cr Our u' Or? n w a°i O 00 Q ' II a 2'BEHIND SIDEWALK cn Q �- " co > It "' N + 0) + °� «' (n o_ O J Cie � °° )7 D 0.1-0.2 0.2-0.3 I.II_:I I I c i CO3 o cl) + ~ CND j I + co Q ~ ^ /� o jp �J �� i� o Q I A ^ N N F-cr) cI, N co N ro+��c�i // o ?i CO3 �'s Oo. OE 0.2 0.3 0.3 0.4 Q c\I It coz I It `� I� a co CO3cf) Q � / Q CO3 B o Q m a U) I co c\l c j 1- w ; ~ C08 / OF 0.3-0.4 0.5-0.6 m a o � it B � :.;... co Z o _ M Z IMo ~ co CONTINUE CUTOFF DITCH AWAY Cie OFROM UMBRIA HILLS WAY TO CUTOFF DITCH FLOW LINE SEE ROAD v TEMPORARY STORM POND. SECTION DETAILS SHEET C3.05 \\ N z SEE DETAIL THIS SHEET. TEMPORARY STORAGE POND FOR OFF SITE STORM O WATER RUNOFF FROM UPHILL OF UMBRIA HILLS WAY. Q �C\\FL=2566.11' 06 (TO BE REMOVED WITH FUTURE DEVELOPMENT.) U �Sss , 6% o0 '06,�� ���� TOTAL RUNOFF AREA=3.72 ACRES Q 0 20 40 80 120 02 h� .,`L�� DESIGN PERC RATE=2 IN/HR O S6 J �0,�1 DESIGN STORM=100 YEAR,60 MINUTES 2 sOQ �O�OQ RUNOFF COEFFICIENT C=0.15 RUNOFF FLOW RATE=0.47 CFS O FREE BOARD=0.5 FT 1 1 1 TOTAL RUNOFF VOLUME=1692 CF L.LI W TOTAL STORAGE VOLUME=1897 CIF J U Z) POND BOTTOM TO BE FREE DRAINING MATERIAL, ASTM C-33 FILTER SAND OR APPROVED EQUAL. O Z °D I` o {; LL o :.j. >> 06 N V L� W co c0 (o I z v! Q (n � + N I _ J Z 2570 v NIZT CD r N N 2570 co Q cn w U) N \ `� w FINISHED GRADE AT ~ w _ ROAD CENTERLINE _ Q J -o_ a a � CONTRACTOR TO VERIFY TIE IN ELEVATION 0.48% _ _ - - - - I - I _ _ _ - - - - - - - - - - - - - _ o I _ - - = Q Q -2 00% -2.00/0 11.30% - - _ _ _ - - - - rn - L6 co z _ _ _ EXISTING GRADE AT r c0 O ILL2565 I - - - ROAD CENTERLINE N + Ln O _ 00 o N 2565 }' � N II _ Hw 12 W C, \ VILLAGGIO WAY CENTERLINE U w " a W 12"W M o O I - W VILLAGGIO WAY- r-� W w w I 12"W w - - - z 2 2560 _ - - - - - - - - - - - - - - - - - - - - 2560 I > I z J a _� T _ _ _ _ - - - - - - - - - - - - APPROXIMATE HIGH GROUNDWATER -I O _ - - - ELEVATION AT ROAD CENTERLINE 8"SS I Q I I V/ Z v 2 - ' I 8„SS Q 10"SS _ C, z 2555 2555 I �/ o \ I W i � 2553 _ 2553 \ J Lo Cn V' Lo co W O O 7 O N Lo m rn M O O co O M V O 00 M N (fl Lo \ O M CO Ln (O 6) Lo N N V Lo CO 0T 6- N - (O M ti O 00 V r- 00 M N LC) (O 00 Cn O Q U V Lo 00 Ln co Ln d- (O Lo CO Lf) (O Lo (O (6 � (6 1` (O r- t_ r� � 06 � 06 o0 oC) 00 O 00 6 \ \ w Z O (O O O O co O (O O (O O O (O CO O (O (O O (O O (O O O (O (O O (O O (O O O O \ \ co Ln Lo Ln to Ln L/) Ln LC) Ln Lo Ln Lo Lo Ln Ln Lo Ln Lo LO Lo Ln LC) Ln LC) Ln Lo Ln Lo Ln L() Ln L() N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N \GL co a 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50 29+00 29+50 30+00 30+50 31+00 31+50 \`A) \ � < O \C \ ATTENTION: o, O \,p \\ W NAVIGATOR DR 0 1/2 1 \ IF THIS BAR DOES NOT MEASURE \F \ 1"ON 22x34 SHEET or 1/2" ON Z \ 1 1x1 7 SHEET,THEN DRAWING IS S UMBRIA HILLS WAY PLAN AND PROFILE `\ \\ NOT TO SCALE w Q DATE: April 29,2024 04 STA. 24+00 - 31+50 PROJECT: 240076 N VERTICAL SCALE: 1" =4' KEY MAP SHEET: O HORIZONTAL SCALE 1" =40' 0 (WHEN PRINTED 22"X34") N_ J 0 m Sc KEYNOTES F� j, ST RFc/ti aC01 PEDESTRIAN RAMP AND TACTILE WARNING SURFACE PER ACHD SUPPLEMENTAL SD-712 8 56 05/08/24 0 J CO2 4'VALLEY GUTTER PER ACHD SD-708 v qTF �pQ� F- 0, of IY N�• CAR? CO3 SHALLOW INLET PER ACHD SD-715 U) \�\ IPA C06 INSTALL(4)4"CONDUITS N ry M w w w C - x 2 2 �E GO O�SpG � w N o o z o w Q �EMP�MP`FtP v O ,� C07 INSTALL(4)6"CONDUITS a 3¢ a w m w < IY Y \6 + °�p m o Q a Q W A �, + - N �S vMg`t�PHC�\ON C N N N o 0 0�\ \1 SE N 0 o v o cwi �..� \NTE SHEET C3 0 v v v `i° -A w (Nr r i° Z O A gEE PERMANENT ACHD EASEMENT O + W W \\ N cs _\ 6 N <,� a� rn , rn O .w .1 2571 r w �cO N 2'BEHIND SIDEWALK N X- -A 6?0 257u cn oo CO3 A -A `'''-G w N G 2569 1 x`'�w� cn -A -A U, a-,A N o° N c n ��N 0 2570 \ NOTES: � �W 0v � . 2571 1. CURB RETURN RADII ARE 20'TO BACK OF CURB UNLESS OTHERWISE NOTED.ALL ACCESSIBLE r, �, OO + \W - + P + w + 0 1\ n 0 -\ r o ROUTES TO MEET CURRENT ADA GUIDELINES.ACHD WILL CHECK CROSS SLOPES AND RUNNING O co O. v Q 00 W (7 G�p G +r N1 co) G N cNs a 0 is , o y o o, + n w �, o a) _,� A'w •= SLOPES AFTER CONCRETE IS POURED.ANY SLOPES EXCEEDING ALLOWABLE MINIMUMS OR Z Oo ' xo O` co o U U G n \\ 'cr \N w o G o C; o '���1 �' MAXIMUMS WILL BE REMOVED AND REPLACED AT THE EXPENSE OF THE CONTRACTOR. B . -� P N n $ \\ i cNr 25�1 r P/ .�'Y`: s 3$ I- co M1 h0 ,� h M p o co Q a o� N + a, r• ` o \ \ CONTRACTOR SHALL VERIFY SLOPES DURING STRINGLINE/FORM PROCESS. MAXIMUM CROSS ry' e O ry ,%V x p)• O N i W N 00 '� O \N N CNP O O/ �...:. �o H X -` �Q V �R o O' ry CO3 A o q W cr o N C, o G o o 0 0 . _ ��L � * o .0 J . :' , r - Ln N >O r o 0 0 / ✓` ` \ �1� SLOPE 1.75%. MAXIMUM RUNNING SLOPE OF 4.75%. VM�ry N ��� o o co -u (r\ri� e NPR nc?}�OO �\��0�9. �6 / � ,.. / 4� 2 CONTRACTOR TO COORDINATE DRY UTILITY SERVICES WITH APPLICABLE UTILITY PROVIDERS.y c� Ij LO n ry O N _ 26 n' - '0 n °' `' 3� 3 SEE SHEETS C3 02 THROUGH C3 03 FOR DETAILED INTERSECTION GRADING Z O LL �� / , \ > a. t, �Q G� ^ `�- 0) M o cr \N '0 c" ' r f/' �� o° N.\ ` TYP. o N \\ n 4. SEE SHEETS C3.04 THROUGH C3.05 FOR STORM DRAINAGE SWALE DETAILS. W �Q �j �Q U�+ �_ch (i �, / +00 R15' UUi \32xo 2569 •° ti� N < 12' 3 \ /TYP. R50' o 07 W 5. SEE SHEETS C4.00 THROUGH C4.01 FOR UTILITY PLAN AND PROFILES. ❑ U R15' Ln571 TYP' w \ \ 0 6. SEE SHEETS C6.00 FOR SIGNING AND STRIPING PLANS. 1. q `V�� ,. ..-' C01 '35+00 V\GA�OR OR '4i ti ° ���s \ " _:r=.:''r: : w o / �W \ 0 48°I° W NP N �J• 2�F� y y 7. SEE SHEETS C7.00 FOR STREETLIGHT PLANS. 12" `BOO �,°j <r' .. �qy �..:� Col / � IN N y + r co' 04,' \ ... \ 12�- cot - w rn`s\ w \N ?-2y►Z H Doti ry� \ ° • 33+ 34+00 • ° r' .N Z �O G� �\ 1 Op �� G O M _ o v \ 1\ w �x OO�c) / i 8„s — R30' CO2 n y n—w \\ w N\%N�' �`\�\ o \6 \N �� w z „ \ oti�h 2570 — i - N �� \� N FLOW LEGEND `c o ,�� R200' TYP. �/ �,. P w r \\\ cr m ?� o ooO V d. ' . s / ° 1\ 00- ? w w o p \\\ 'o W 25 YR PEAK 100 YR PEAK \ co 1 - -, ; ? 257 i cs L' 2 0 �� w w GRADE TEMPORARY BORROW ! : :• C01 N cr) G 2570 w 0 FLOW(CFS) FLOW(CFS) U) i, h ry O ^ N . "(P -� -1 -1 i c,�o s a N N 0 \\ p cs Q °j ° O ry�\ oo .: '?_":f�_ n' -� n N G G y cs.os s N J I \ w Oo DITCH AROUND TEMPORARY I— /� c, /, \W \\ v N 1\ xo � ti V �\ry0' O / C06 \\ wN yn, yn wN, 251 •00� 0 o cr _ \ I \ O � ` h � N �cr \I \\ \\ � \\ C, � CULDESAC PER ACHD OA 0.0-0.1 0.0-0.1 _ , �Oo ,ti 9. X, cn + -\ w N �"c + -\✓ N � \ '\\ STORMWATER DESIGN �'\ - °... + 0 rn� ro' per'' �`r\ oo rn \ `` p O ?5 0 7� \ \\ GUIDELINES SD-05 69 U of o. ... c�i�it% 0 -Co0' a' + o o� o a 0 �, C, \\ \ OB 0.0-0.1 0.1 0.2 V H Mry ry < �q 256 U ^ U o o- _ N c9 0, �, o cr c9 0 / Z CO3 '� ,� 25j69 8 U x � o o co < N `r N CUTOFF DITCH FLOW LINE,GRADE W �•� Q 6 . a c°o-a ai �, - N D C) _ N rn \/ OC 0.1-0.2 0.1-0.2 Q n A g / N ^�=o w 11 N 26 6 o CUTOFF DITCH ON SOUTH SIDE OF ) \\\ \ / _ N_� U 1° j.... + �.. o / U,�= G o p W oo - UMBRIA HILLS ROADWAY TO / \\\� Cie 0 w co o U_� 1' .\ A ?� '`' REDIRECT SURFACE RUNOFF FROM \.\\ O O O Q () rn o G n p \ D 0.1-0.2 0.2-0.3 cn PERMANENT ACHD EASEMENT F- M C3.05 - o�! N < \� \N cNr J U n ADJACENT LAND.SEE ROAD o Q 2'BEHIND SIDEWALK o °' v ° `�y -\ C, a�` + CO3 SECTION DETAILS SHEET C3.05 OE 0.2-0.3 0.3-0.4 < o Z + la J \ . O - / + M co I \ U' \c,N W,Na , / �,•0 ^, o M Q _ _� M M n \ . � + � moo `' C OF 0.30.4 0.50.E m � o o _ Q v~i CO3 \ 14� N m � �, MZ m N O W 04 co 70 u- O0 20 40 80 120 O W W J U) w LL Z 0 Z) O Q o 06 '^ d 2575 2575 V) W (D Z Z U Q Z FINISHED GRADE AT Q -ROAD CENTERLINE - Q 0.48% - - - - 2570 - - _ - --- - - - - - - - - EXISTING GRAVITY IRRIGATION 2570 Q 0 DITCH TO REMAIN,SEE SHEET 4.01 FOR PIPING DETAILS. EXISTING GRADE AT Q _ ROAD CENTERLINE z O ILLN N O O + O fi IN = — — — — — — — — — — H.�/ N N ° w 12"W ~ ry w M J d b 12- 2565 C 12"W W - M 2565 W VILLAGGIO WAY ❑ O w J LL CL - - - - - - - - - - - - - - - z J a � - - - - - - - - - - - - - APPROXIMATE HIGH GROUNDWATER O ' - _ELEVATION AT ROAD CENTERLINE J � H W 2560 ¢ I 2560 m Q $"SS m — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — ❑ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - - — — — — — — — — — — — — — — — — — — — — — — — — — — - Z a — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — \ \ m ~ 2555 2555 \ Q U (O to O O co N I� O 00 to h 00 N (O O 00 't 00 6 O Lf) \ \ m Z �? O N N O ((, O h N O N M I� M O) N M c} V (O CO 6? o \ 2 — 00 O O O O O o 0) o 0 o O o O o 0 o O o o N N \ _ (O C4 (O (O (O (O I� O ti ti ti iz ti Ln Ln Ln LO Ln Ln Ln V) Ln Ln Ln LO Lr) V) Ln LLB Ln LO Ln Ln Ln LC) to LO to to to V) / N N N N N N N N N N N N N N N N N N N N N N N N N N N N \�`� \ — now z a O _ v _ v \ �' \ ATTENTION: o Of 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00 36+50 37+00 37+50 38+00 \ 1,p NAV1G W gT0 0 1/2 1 zz 0 \ A\\ RDR IF THIS BAR DOES NOT MEASURE \ 1"ON 22x34 SHEET or 1/2" ON z \� \ 1 1x1 7 SHEET,THEN DRAWING IS S UMBRIA HILLS WAY PLAN AND PROFILE `\ \\ NOT TO SCALE W Q DATE: April 29,2024 04 04 STA. 31+50 - 38+00 PROJECT: 240076 VERTICAL SCALE: 1" =4' KEY MAP SHEET: O HORIZONTAL SCALE 1" =40' 0 (WHEN PRINTED 22"X34") C3.01 N_ J 0 tw_— gS\ON A L £N pST RFC�y� w 8 56 a s�05/08/24 0 F— v qTF \�P� U p OF Of NG• CAR? H U) / vry Of � N ❑ U U � ❑ Z Q W '� _ w N W � tz ❑ Z W � / v W z a z a Y O o _1 G1 I 8 ` p ❑ O -i 3 U w Q a L �L�,\\ Q L —J - - - _ '00, W cU C U En w IQY OCL a r10 JG a OO\ �O f. : v — — — — — — — J — — — — — — — as C I I D Q Z �8 d d v ❑ 4 d d I D Q Too Toc f f ° � � o o , 1 w \�'S ohs L7 �h� �h� I L�,\ 00b,� I 000000000 Z G>O, d 6d,0 J BOG, BOG, I \`,s6 ,U Cr� Q I�� Q ���I 8_1w L �� �+�_1—� OC\\ - sss iti�� 8' I. 0�� ass a 8' �c�, °\9 a ,�0`0 000000 �' h G s �- U �C'o 697,000000000, s6j I I p`L 0000000000 /U u�� :I U) z Z O 2s6 A 8 6°% TO OS - (n �G 1b �Aj 8'TRANSITION FROM I O (b' \1.56%� 8'� I 6"VERTICAL CURB I D (A �� 2sG I I �,`L4' :—`, - TO PEDESTRIAN I I p > U Q- TLC'`. /0 TO 6�Q 8'TRANSITION FROM I Off' ��'— ,Q 1� I RAMP AT ALL RAMPS. q,� :I v W w Cn c'30 c'�s `SSG 6"VERTICAL CURB � �g� \�O',.: I I. I �' ❑ �2 09 690 TO PEDESTRIAN I BOG ,,� G I pQ I �Aj RAMP AT ALL RAMPS. OG 3p, —COMMERCIAL DRIVE — — � D J I (FUTURE-PRIVATE) � — COMMERCIAL DRIVE — — SOP — COMMERCIAL DRIVE I I I 26 (FUTURE-PRIVATE) + Z (FUTURE-PRIVATE) 26 I— �� �`eG,�� O QG1 I I TO �G'.1 OGpL G•.ti �� I } z h h��� o Oc°2 G,,ti`'� Imo— Q > — — — — — — — — L I QJ' U) D o �.� O— CO 1.Sq/ �ro6' ��2 55°/° 06 _C'J s� I �G ��R o 0 0 0 0 0 0 0 o b /,���o �to°� °o, J v O \�� /i/ -~-- `O h6�• _ � v 0,1 w ''� °� 0000000000 `off ��` - 1 ss� C` 00000-00000 2s6 o �- 'a� Q Q 0 �J 6\ \ h �\ �\\2 >, 2ss, / SO I c�i p D o d \ JG .th� Ly�o sbs ���',� 27 0 2`S6 h V . m v Q c I �i I e 10 D 0 <OG o �JG l�� ,Ol..- RAJ o O� I 0�� z T T �O lO D Q m a �ti d �6\0 oc2 d a oc`�2 I v N a M L L �OG.,L �OG.,L ^ s6 Os S6 20 D. � M Z N ti O I.\ I I �� o ` 00 o N O 011 O o UMBRIA HILLS WAY INTERSECTION 'A' DETAIL a ° I D UMBRIA HILLS WAY INTERSECTION 'B' DETAIL d v D w Z U O O '� U) d 0 5 10 20 30 0 5 10 20 30 �/) J w z rJn z z v Z � J Q W < J C) 0 o = z z Q O LL o O � U 0 w _ m W F O W VILLAGGIO WAY— -� W ^ w L/J w U W a INTERSECTION'A' I z J O �_ Z Q I v C� z w cn _ CC cc Qco C G m ABBREVIATIONS LEGEND U) NOTES. FL FLOWLINE PROPOSED FLOW LINE \ INTERSECTION'S' a � 1. CURB RETURN RADII ARE 30'TO BACK OF CURB UNLESS OTHERWISE NOTED.ALL ACCESSIBLE ROUTES TO MEET CURRENT TOA TOP OF ASPHALT \ c�o = ADA GUIDELINES.ACHD WILL CHECK CROSS SLOPES AND RUNNING SLOPES AFTER CONCRETE IS POURED.ANY SLOPES \ ~ EXCEEDING ALLOWABLE MINIMUMS OR MAXIMUMS WILL BE REMOVED AND REPLACED AT THE EXPENSE OF THE TOC TOP OF CONCRETE O O O PROPOSED TRUNCATED DOME \ b CONTRACTOR.CONTRACTOR SHALL VERIFY SLOPES DURING STRINGLINE/FORM PROCESS.MAXIMUM CROSS SLOPE 1.75%. TVC TOP OF VERTICAL CURB \ \ m Z_ MAXIMUM RUNNING SLOPE OF 4.75%. PROPOSED TYPE III BARRICADE \ PC POINT OF CURVATURE \ \ d 2. SEE SHEETS C3.00 THROUGH C3.01 FOR ROAD PLAN AND PROFILES. z D PT POINT OF TANGENCY �_2580`� PROPOSED MAJOR CONTOUR \9,�� \ \ O \ ATTENTION: o 3. ELEVATION POINTS PREFIXED WITH"TOC"MAY NOT REFLECT FULL CURB HEIGHT AND BE WITHIN A CURB TRANSITION TO GB GRADE BREAK \G) 0 1/2 1 zo Ur PEDESTRIAN RAMP.CONTRACTOR TO CONFIRM PROPER FRONT DRAINAGE OF DRIVE APPROACHES. �_2582 _� PROPOSED MINOR CONTOUR \�'oi\\ W NAVIGATOR DR IF THIS BAR DOES NOT MEASURE \F \ 1"ON 22x34 SHEET or 1/2" ON Z \ 1 1x1 7 SHEET,THEN DRAWING IS \\ \ NOT TO SCALE w Q \ DATE: April 29,2024 a N PROJECT: 240076 o KEY MAP SHEET: 0 N J 0 tw_— gS\(jN A L £N i,,\ST w 8 56 a s�05/08/24 0 H v qTF \�P� U p OF Of NG• CAV U) To TL C) C7 C) s�`S�p 26' Gi�� N M w w Q�Q w Q 6 x 2 2 Q z LU W z a z a Y O O w w 4 T C'', \O O -i 3: U w Q CO 2S�O G''y� g m p U U Q 4 a Q C`R25�S,D4 25� 6j 0 �\ � , e II\ G�y a. OG , O OO G z a a ° o oQO � 00j 61T 4 1.43% o° � ° 2.04% G Q 4. 61 Q4Cn o o� L7 O o\ > rb ° Q ooM A_; � o � p6 U w \ W w d o W To g � ^h \ I 8 C2s09 OU Iv O 8' I o,. z o LL - - - - -- - w T� I °�° I > W w 09,A c3 Q�1 O of s�9 °° U) z w z 0 — _ tip o _ P' �_ W NAVIGATOR DR — — O 0 w } z an � Z) Cie w � G� 00 Q F- �e _ �`O�°^z o �C�2 O 1 f_ s� Q a v� G s °ss 0° o .... ... ...... .... ...... j., .. � J e M N O00 TRANSITION FROM p 0' \O 6^VERTICAL CURB �O F�'�C� _ — — — — — — ~ TO PEDESTRIAN \` U _ _ RAMP AT ALL RAMPS. `,SRO �`AJ T O w 6// 4_ /\O O > �S Q 4 4 4 Z a a 0oo 0� o o00 2� G 1.04% o0 ^b 4.0 4%' a 4 a 4 d Lo 0,( o w o o � 0 o o o �sto oC,� O o� O s TOC=2570.18'(1T) ��A To To LL $ °�\ � LL VJ�C� I 8 S,O s,� Q O 40 h� �2s� .,�2" l8, w' G.,1 DO ' ) V J �} J 1 1°� �-� 26' �- •'1.. JG SRO UJ Q _... o = z Q UMBRIA HILLS WAY INTERSECTION 'C' DETAIL z O cl LL p Q — H � U w _ m W F O W VILLAGGIO WAY ^ w L/J 0 N O w U W w 0 5 10 20 30 � I _ z Q I v Z w _ CC cc Qco C G m ABBREVIATIONS LEGEND z NOTES. FL FLOWLINE PROPOSED FLOW LINE \ a 1. CURB RETURN RADII ARE 30'TO BACK OF CURB UNLESS OTHERWISE NOTED.ALL ACCESSIBLE ROUTES TO MEET CURRENT TOA TOP OF ASPHALT \ C�o = ADA GUIDELINES.ACHD WILL CHECK CROSS SLOPES AND RUNNING SLOPES AFTER CONCRETE IS POURED.ANY SLOPES \ ~ EXCEEDING ALLOWABLE MINIMUMS OR MAXIMUMS WILL BE REMOVED AND REPLACED AT THE EXPENSE OF THE TOC TOP OF CONCRETE O O O PROPOSED TRUNCATED DOME \ b CONTRACTOR.CONTRACTOR SHALL VERIFY SLOPES DURING STRINGLINE/FORM PROCESS.MAXIMUM CROSS SLOPE 1.75%. TVC TOP OF VERTICAL CURB \ \ m z_ MAXIMUM RUNNING SLOPE OF 4.75%. PROPOSED TYPE III BARRICADE \ PC POINT OF CURVATURE \ \ d 2. SEE SHEETS C3.00 THROUGH C3.01 FOR ROAD PLAN AND PROFILES. z PT POINT OF TANGENCY �_2S80`� PROPOSED MAJOR CONTOUR \9,�� \ \ O \ ATTENTION: o 3. ELEVATION POINTS PREFIXED WITH"TOC"MAY NOT REFLECT FULL CURB HEIGHT AND BE WITHIN A CURB TRANSITION TO GB GRADE BREAK \G) 0 1/2 1 zo Ur PEDESTRIAN RAMP.CONTRACTOR TO CONFIRM PROPER FRONT DRAINAGE OF DRIVE APPROACHES. �_2582 _� PROPOSED MINOR CONTOUR \�'oi\\ W NAVIGATOR DR IF THIS BAR DOES NOT MEASURE \ INTERSECTION'C' 1"ON 22x34 SHEET or 1/2" ON o \ \ 11x17 SHEET,THEN DRAWING IS 0 \\ \ NOT TO SCALE w Q \ DATE: April 29,2024 a N PROJECT: 240076 o KEY MAP SHEET: C23.0 3) J 0 H Sc\ONAL £N ,S T a0 30 60 120 180 8 5 6 s�05/08/24 0 H v qTF \�P� U p,, OF Of NG• CAR? H U) NOTES: U) Q 1. BIORETENTION SWALES SHALL BE CONSTRUCTED ACCORDING TO ACHD ry N X w _ w STORMWATER BEST MANAGEMENT PRACTICE 30. iv p U U = w N o Z a z a Y 00 Q 2. SEE SHEET C3.05 FOR TYPICAL SECTIONS OF BIORETENTION SWALES. 0- � 3 wof w v O w 9 = U o_ Q3. BIORETENTION SWALES SHALL ACHIEVE A MINIMUM INFILTRATION RATE OF m p p U Q u- 21NCHES/HOUR. O W VILLAGGIO WAY Z IN 4. SUBSURFACE STORAGE DEPTHS SHOWN BELOW ARE MINIMUMS.THE ------_-____ - --- GRAVEL LAYER SHALL EXTEND TO THE SILTY SAND WITH GRAVEL LAYER. p VJ •m.: j:; ;:j .,:.�rrx... �..sr�+.•r�sc.�t•: �-�.:�.,�:yw-�t� } i�,�.�:-�------ ..: - - - - - - - - - - - - - - - - - - - - - - - - - - - - W STA=24+81.87(START) STA=24+81.87(START) a 29'LX2'WX4.26'D o 4 0 ~4 29'L X 2'W X 4.26'D z SUBSURFACE STORAGE AREA c3.05 � - C3.05 SUBSURFACE STORAGE AREA W STA=25+11.29(END) I `" STA=25+11.29(END) .71 V! Z li \l % O U iY W W > c) U) = o wo Q o .` + O m N >_ 2i U) H STA=26+56.82(START) Z 21'L X VW X 4.26'D t STA=26+56.82(START) SUBSURFACE STORAGE AREA 4 4 21'L X VW X 4.26'D C3.05 _ C3.05 SUBSURFACE STORAGE AREA O STA=26+77.64(END) STA=26+77 o .64(END) Z U o H I o I O + c0� Z n W STA=27+47.54(START) 54(START). 0 � 28'LX1'WX4.26'D STA=27+47 . :- �� wry O SUBSURFACE STORAGE AREA 4 4 28'L X VW X 4.26'D Cie0: co 0, c3.os. C3.05 SUBSURFACE STORAGE AREA 00 Q STA=27+75.90(END) STA=27+75.90(END) QU) C) o 0 U) I o+ m o 00 Z Q M CieM Z to M N LL / 00 a TEMPORARY STORM POND \ N OSEE DETAIL SHEET C3.00 U_ u- , `STA=28+78.99(START) 0 \ STA=28+91.55(START) 48'L X 1'W X 4.26'D O SUBSURFACE STORAGE AREA 4 + 48'LXVWX4.26'D C3.os c3 os �93�ENDP�(1 49'LX1'WX4.26'D SUBSURFACE STORAGE AREA 2g+� lg\ W r• ` :; : Sip= gk6gg2 SUBSURFACE STORAGE AREA gTP=2g+21.16 IEN�I gCp 2 ti`��Ol V J +36 A5 ls�PR�� cos .,3�X�� �pe�1 26'L X V W X 4.26'D z Z s\K2g ` 4' k ��P � g SUBSURFACE STORAGE AREA /�� OC3.05. V:.�. \ a k��' `Q1 1 I `/y O U _° ok 49'LXVWX4.26'D `• :z oo ��P ��Ol OSUBSURFACE STORAGE AREA l��Ql ` + pk LL Q 3$ ` 4 5�a C3.05 `r i gk$� W W ��5 58- W X 4.26'D J c3 os oo P,3`XA SUBSURFA E STORAGE AREA 6G L ID D 15F 5C �3 P�P �G P Q J Q 5� $� ` G� �� 5 .3Lk �� 13'LX3'WX3.26'D ILL pk Z - �� P� O x SUBSURFACE STORAGE AREA Q O 26'L X VW X 4.26'D �Q' .fj/ c3.os c�� SJ o O- SUBSURFACE STORAGE AREA 0 ` 9 '� x� U) o r/ } ti koo \ •? (Lire N n i.:. M M 'l W o `gCP� 4 coIf Q + � V J F a g •'" C3.05 U) F- M �j C3.05 + It k 4J r.,i _ ¢ M �-r 5C 1 xoo iy :, CO} ^ •mil.C3.05 Z 58'LX2'WX4.26'D X35 ,.. ` W SUBSURFACE STORAGE AREA .,30 y� 34+00 U a � > m U 36+00` q' ���"ioW NAVIGATOR pR oo 3 m 37+ x s,; 5 a Cn TEMPORARY DITCH ROUTING RUNOFF FROM THE � �... = SOUTH TO TEMPORARY STORM POND. QC3.05t` "• `•'"' = - H SEE ROAD SECTIONS DETAILS 1 AND 2 SHEET C3.05 4 -_^ N ::. Q U hj CMp Q Z ...��... C3.05 M W Q d CO If M o ^ 15 W z Q M + CO O 51'LXVWX3.26'D COco `r a M I i. ATTENTION: rr,o cr- SUBSURFACE STORAGE AREA Q 0 1/2 1 o ~cl) U + + ~ Q cy)i M IF THIS BAR DOES NOT MEASURE 45'LXVWX3.26'D Q I- w SUBSURFACE STORAGE AREA Q co ~ 1"ON 22x34 SHEET or 1/2" ON z co 11x17 SHEET,THEN DRAWING IS 9 cl 18'L X 2 W X 3.26'D NOT TO SCALE CO SUBSURFACE STORAGE AREA Q DATE: April 29,2024 a N PROJECT: 240076 of O N SHEET: o O 3.04 N J 0 tw_— gc A L £N ST RFCiy� Q 69'ACHD RIGHT-OF-WAY w 8 56 a s�05/08/24 0 U 4:1 DAYLIGHT 4:1 DOWN FOR 1 1 4:1 DOWN FOR 4:1 DAYLIGHT v0, OF ly- TO EXISTING MINIMUM 8' 10'PUBLIC UTILITY EASEMENT 10'MULTI-USE PATHWAY 17'BIORETENTION SWALE 18.5'CENTERLINE TO BACK OF CURB 18.5'CENTERLINE TO BACK OF CURB 17'BIORETENTION SWALE 10'MULTI-USE PATHWAY 10'PUBLIC UTILITY EASEMENT MINIMUM 8' TO EXISTING G. CAR? HORIZONTAL HORIZONTAL U) 11'TRAVEL LANE 1 V CENTER TURN LANE 11'TRAVEL LANE w ry Q N X 2 2 Q � U) Z tz ❑oN 2TYP 2i T Y\I/\I/ \I/ \/\I/ \I/ \I/ Zza o Q \ / 2'MIN. \I/ \I/ \I/ `I/ \I/ \I/ 2'MIN. \ / m w = o \ / \I/ \I/ \I/ J/ \I/ \I/ \I/ \I/ \I/ \I/ \ / ❑ ❑ Q LL / Q / PAVEMENT SECTION PER \ Z BIORETENTION SWALE SEE DETAIL 6 THIS SHEET SIDEWALK PER \ w 6"VERTICAL CURB AND ACHD SD-709 0 _Q DETAIL 4 THIS SHEET AND GUTTER PER ACHD SD-701 (n LANDSCAPE DRAWINGS co 2 a UMBRIA HILLS WAY NO PARKING SECTION N.T.S. 1 z w 69'ACHD RIGHT-OF-WAY U z o U 1, 1' O w 9.5'LANDSCAPE BUFFER 9.5'LANDSCAPE BUFFER w n- 4:1 DOWN FOR OR SWALE,SEE SWALE OR SWALE,SEE SWALE 4:1 DOWN FOR w U) 4:1 DAYLIGHT 4:1 DAYLIGHT TO EXISTING ❑ MINIMUM 8' 10'PUBLIC UTILITY EASEMENT 10'MULTI-USE PATHWAY STATION SHEET C3.04 26'CENTERLINE TO BACK OF CURB 26'CENTERLINE TO BACK OF CURB STATION SHEET C3.04 10'MULTI-USE PATHWAY 10'PUBLIC UTILITY EASEMENT MINIMUM 8' TO EXISTING HORIZONTAL AND LANDSCAPE AND LANDSCAPE HORIZONTAL Q DRAWINGS DRAWINGS H= 9'PARKING 1 V TRAVEL LANE 1 V CENTER TURN LANE 11'TRAVEL LANE 9'PARKING H \ \I/\I/ \I/ \I/\I/ \I/ \I/\I/ \I/ \I/ I/ \I/ \I/ \I/ \I/ \I/ \I/ 2%TYP 2%TYP \I/ \I/ \I/ \I/ \I/ \I/ -J \I/ \I/ \I/\I/ \I/ \I/\I/ \I/ \I/\I/ �— \ / 2'MIN. 2'MIN. \ / W \ / o 0 0 0 0 0 \ / I— Z / \ O / PAVEMENT SECTION PER \ SIDEWALK PER U i / DETAIL 6 THIS SHEET \ \ U) 6"VERTICAL CURB AND ACHD SD-709 1— GUTTER PER ACHD SD-701 C Q \ 0 W Z :2an UMBRIA HILLS WAY PARALLEL PARKING SECTION N.T.S. 2 � � = a U m z 0 U) N Z t0 I— Cie I? N 0 / v Q 00 ` Q \ O Z a _O \I/\I/ \I/ \I/\I/ \I/ \I/\I/ \I/ \I/ \I/ \I/\I/ \I/ \ / rQr U Y 4' �< o 0 / \ Q 12"WATER MAIN 8.5' o 0 10'JOINT TRENCH w10'JOINT TRENCH m. U) 8' 10' 10, Z) w o 0770 0 10"SEWER MAIN 145 Z O U O Q UMBRIA HILLS WAY UTILITY CORRIDOR N.T.S. 3 U) w W Z � J Q 1.5'DEEP MAX ABOVE GROUND STORAGE 7"DEEP MAX ABOVE GROUND STORAGE Q J FLOW LINE FLOW LINE U) SIDEWALK VARIES WITH Q w' 1.50' BULBOUT GEOMETRY 1.50' SIDEWALK 9.5' Q (17'MAX) 1.50' 1.50' 1.5'STEP OUT ZONE 7 Z 1-2" 1-2" 1-2" SP-3,0.50 INCH(%")MIX, PG 64-28, 1-2" PLANT MIX ASPHALT PAVEMENT>_ \1 \1 ry ui o o O O N a \I/ \I/ M 1 MPX 3/4"CRUSHED GRAVEL AB M 0 2 O \1i \1i \1i \1i \1i qX 3 6"MINUS PITRUN SUBBASE W 3 MIN 2'DEPTH COMPACTED SUBGRADE W o W MIN 2'DEPTH Xp U) = BIORETENTION SOIL MINIMUM 3' PAVEMENT DESIGN TABLE Q I— BIORETENTION SOIL MEDIA PER ACHD 7 w SEPARATION TO TRAFFIC Z SPECIFICATIONS o MEDIA PER ACHD MINIMUM 3' GROUND WATER O r — DESCRIPTION AC AB SUBBASE R-VALUE � � SPECIFICATIONS O O SEPARATION TO 2"THICK CHOKER LAYER ASTM 4.26'MIN p 2'WIDE,2"WASHED INDEX v, Z SEE SHEET C3.04 FOR p p D WIDE,2"WASHED GROUND WATER #8 OPEN GRADED FRACTURED DRAIN ROCK COLLECTOR ROAD(W VILLAGGIO WAY,S UMBRIA HILLS U W MINUMUM DEPTHS DRAIN ROCK AGGREGATE BEDDING COURSE GRAVEL SECTION WAY,COMMERCIAL APPROACHES, INDUSTRIAL 3" 6" 17" 8.0 5 g GRAVEL SECTION w tAPPROACHES) m U — 2' MAX HIGH SEASONAL o Z_ 2"THICK CHOKER LAYER ASTM VARIES GROUNDWATER ELEVATION #8 OPEN-GRADED FRACTURED SEE SHEET C3.04 MAX HIGH SEASONAL a AGGREGATE BEDDING COURSE FOR WIDTHS GROUNDWATER ELEVATION NOTES: g U 1. PAVEMENT, BASE,AND SUBGRADE SHALL BE CONSTRUCTED PER THE co Z NOTE: NOTE: SPECIFICATIONS AND RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL d REPORT,ACHD,AND THE ISPWC. co z Z 1. BIORETENTION SWALES TO BE CONSTRUCTED PER ACHD 1. BIORETENTION SWALES TO BE CONSTRUCTED PER ACHD 2. THE PAVEMENT SECTIONS INDICATED IN THE PAVEMENT DESIGN TABLE ARE o BASED ON THE ABOVE MENTIONED TRAFFIC INDEX AND"R"VALUES REFERENCED 0 1/2 1 z Q 2. GRAVEL LAYER SHALL EXTEND TO FREE DRAINING 2. GRAVEL LAYER SHALL EXTEND TO FREE DRAINING IN THE MERIDIAN 118 GEOTECHNICAL ANALYSIS BY GEOTEK DATED APRIL 4,2020. Q MATERIAL,BUT NO FURTHER THAN THE SEASONAL HIGH MATERIAL, BUT NO FURTHER THAN THE SEASONAL HIGH "R"VALUE AND CORRESPONDING PAVEMENT THICKNESS SHALL BE CONFIRMED 0 DURING CONSTRUCTION. IF THIS BAR DOES NOT MEASURE GROUNDWATER ELEVATION. GROUNDWATER ELEVATION. 1"ON 22x34 SHEET or 1/2" ON 11x17 SHEET,THEN DRAWING IS o 3. DESIGN INFILTRATION RATE=2 IN/HR 3. DESIGN INFILTRATION RATE=2 IN/HR NOT TO SCALE Q 4. TARGET SOIL LAYER=SILTY SAND WITH GRAVEL 4. TARGET SOIL LAYER=SILTY SAND WITH GRAVEL DATE: April 29,2024 a 04 PROJECT: 240076 c.� O M' N SHEET: C3.05 UMBRIA HILLS WAY BIORETENTION SWALE - STANDARD SECTION N.T.S. 4 UMBRIA HILLS WAY BIORETENTION SWALE - PARALLEL PARKING SECTION N.T.S. 5 PAVEMENT SECTION DETAIL N.T.S. 6 N J 0 m Sc \rjKEYNOTES F� �r ST RE,c�ti 0 CL SSO BACK FILL EWER CLEAN-OUT PER MERIDIAN SD S1,SURVEYOR TO AS-BUILT INVERT PRIOR TO g 56 05/08/24 0 UOFFIRE HYDRANT ASSEMBLY,GATE VALVE, 12"X6"TEE,6"PIPE, LENGTH PER PLAN N CA RP�� k] W02 2"TEMPORARY BLOWOFF ASSEMBLY PER MERIDIAN SD-W12 U) U) h� Q si W06 12"22.5°ELBOW N M w _ ry w I x N H H0 Z LU W W > 12"TEE,VALVES PER PLAN o 0 a Z a L) of O < 0 i �t.r• I w _ b a U I'� W09 12"X 8"CROSS,ORIENTATION AND VALVES PER PLAN Q 1<9 I CONNECT TO EXISTING 12"WATER w Z ; N MAIN.REMOVE EXISTING TEMPORARY W10 2"TEMPORARY BLOWOFF ASSEMBLY PER MERIDIAN SD-W13 O BLOW-OFF VALVE.CONTRACTOR TO o 07 � VERIFY LOCATION OF EXISTING MAIN �. U) 11 I W12 4"TEMPORARY BLOWOFF ASSEMBLY PER MERIDIAN SD-W13 O - SSCO-02 W I Q STA=27+12.21 a J I RIM=2562.17' I so �L 'INV OUT=2556.17 (W) _ \ W j ` .... _ I o W10 `:.:t.. . / •v;::... _... /� � �� NOTES: 24+pp ..':` �2 P 70'of 8"PVC 0.50% �_ . . / x226� b1x� (35 I @ ^ � I �'rry ,� � �\\� 1. EXISTING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON AVAILABLE � Z U / W01 • ±11 LF 6"W \P' RECORD INFORMATION AND FIELD SURVEY.CONTRACTOR SHALL VERIFY LOCATION OF EXISTING Z OILL _ y 25+00 12"W W01 •.: . �' ' UTILITIES VIA DIG-LINE PRIOR TO START OF CONSTRUCTION. O U � 12"W +13LF6"W ..� o � di � ._ .' ..�_•...��Y - W _ - 26+pp ±54LF 8"W _ �_ •_ +31 Lrl2"W "w" / 5 ;�Y� 2. CONTRACTOR TO COORDINATE DRY UTILITY SERVICES WITH APPLICABLE UTILITY PROVIDERS. W U) n- SSMH 09 12"W �.. .', ;` •.... -+ �:,. \ w lolls a... :,a.,: � .': :>... y. . � V I :E� W09 � �'� - �'- a ±24LF 12"W"t' 3. WATER AND SEWER MAIN STUBS EXENDING OUTSIDE THE RIGHT-OF-WAY SHALL BE COVERED BY to"s co _±39LF 12"_W \ ;.:. 08 SSMH-05 °;j / A 10'WIDE EASEMENT ON EITHER SIDE OF THE MAINLINE EXTENDING 20'BEYOND THE STUBBED O o I -.. °• lolls 27+00�190° 12,,W MAIN. H `' a. -:.. :. 9 • . 8„s 28+00 ±166LF 121,W 06 +82LF 12:: _ •: ..... —90° I III - 161' /. UJ SSMH-02 8„s �� 29+00 W02 o� UMBR►A WAY S HILLS a„S —164°�--- — 8„S CONNECT TO EXISTING 10"SEWER ma's=:r• SMH-04 i �j I �' • 4 SSMH-03 64'of 8"PVC @ 0.50% MAIN. REMOVE EXISTING TEMPORARY r;:::::< ZO i O Fj I CLEAN-OUT.CONTRACTOR TO VERIFY U ; r LOCATION OF EXISTING MAIN ±84LF 8"W CI APPROXIMATE INVERT=2554.89' SSCO-03 0+23.45 'I 64'of 8"PVC @ 0.50% ;. .,• y., ., o �.< ° iF.I ° o W10 y ,_ ±84LF 12"W — r.. O �Ii SSCO-01 NV OUT 32557.97'(NE) 0 — — — SO H STA=27+12.21 / W12 t� W RIM=2562.14' SO I �� Ciea n Ir INV OUT=2556.14'(E) J C Fa TEMPORARY DITCH ROUTING RUNOFF FROM THE Cie � coo w SOUTH TO TEMPORARY STORM POND. 00 Q SEE ROAD SECTIONS DETAILS 1 AND 2 SHEET C3.05 Q o U) z Q 0 0: m 0. U) m C. 0 Cie N Z (O M N /0 00 ` O \ O z N _O Q U u_ O0 20 40 80 120 W' w O J Z) LL w O Z o n U O W z 0 z z U) U) co o° 20S �^•) Z W (n W v O W U-) co rl- ITS) M N Lo Lo N V CO 4 � Lr)CO Cn CO CUB III - 11) + 11 CNN I- - Z _ + u') I I I I (n W r CV Ln to In to O +MAN H O, NNN 2 IOMI NZZ O U Z 2570 Ln c\ � LO in LO N N N II 0 = u II Z O Q g > > > 2570 I� N + (O LO LO LC) II = II II Z O 2 Q �_ > > U) ~ Q °p � Co LLO ON � N 1 11 ? c') > > Cn (n � Z Z (n Cn2 - - — J - � NI � 2 II NZZZ O (n (n � _. NCLO4 \ u `3 > > > > -2 N N IZI Z) \ (n U) Of Z Z Z lL co II > uj -XFa- � > ; — T i i QILL O 2565 I — — N - F- + �/ t U W \ CONTRACTOR TO VERIFY HORIZONTAL AND 12 W — M O VERTICAL LOCATION OF EXISTING MAINS. W VILLAGGIO WAY o _ i 12"W LL 5 g a G w W 2 2560 2560 31 ^ w H CONNECT TO EXISTING INVERT z �J J ) U) j CONTRACTOR TO VERIFY ELEVATION- MATCH CROWNS 0.50/o Z EXISTING 24"GRAVITY 0.50% ° I Q I 0 52'of 8"PVC @ 238'of 8"PVC @ _ ( , — = W IRRIGATION PIPE 73'of 8"PVC @ 0.50/o cov a - - - - - w 0.50% I m 179'of8"PVC@ � U v F- 218'of loll PVC @ 0.35% 2555 z 2555 } co CONNECT TO EXISTING INVERT - \ I LL = CONTRACTOR TO VERIFY ELEVATION 2553 _ 2553 \ J Lo 6 (fl W O O 7 O N Lf) O O M O Cfl W O M V (n 00 M N O LC) \ O M CO Ln O O LC) N N V LC) CO � N(T — (O M ti (O — 00 r- 00 M NM (O 00 O Q U V LO W to (M LO It Co u') CO LO CO LC) CO 6 � (O r` O r- t` r� � 00 � 00 o0 o0 00 O 00 6) \ \ m Z (fl (0 (fl (0 (0 O Co (0 Co (0) (0 (0 (0 (0 (0 CO (0 Cfl Cfl Cfl co Cfl (fl (O (fl O (C) (0 (0 (0 (0 O \ \ LOLC1 In u') LO LO LO u') LO LO In LO Lo Ln In l() In Ln In N In Lf) U') In III) LO L() Lr) L() LO L() u')N N \ _ N _ N N_ N N_ N N N_ N _ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N N_ N co a 0 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50 29+00 29+50 30+00 30+50 31+00 31+50 \`A) \ � < O \C \ ATTENTION: o, O \`row\\ W NAVIGATOR DR 0 1/2 1 IF THIS BAR DOES NOT MEASURE \F \ 1"ON 22x34 SHEET or 1/2" ON Z \ 1 1x1 7 SHEET,THEN DRAWING IS UMBRIA HILLS WAY PLAN AND PROFILE `\ \\ NOT TO SCALE w Q DATE: April 29,2024 04 04 STA. 26+50 - 35+00 PROJECT: 240076 VERTICAL SCALE: 1" =4' KEY MAP SHEET: O HORIZONTAL SCALE 1" =40' (WHEN PRINTED 22"X34") C4.00 N_ J 0 m Sc KEYNOTES F� j, ST RFc/ti aIR01 4'X 4'IRRIGATION BOX PER ACHD SD-619 8 56 Ln�05/08/24�0 i IR02 PIPE FLARED END SECTION WITH TRASH RACK. INSTALL 6"RIP RAP, 12"THICK,4'BEYOND v ��P I— SECTION AND TO TOE OF SLOPE U Oy OF �k. l SO "T"-TYPE SEWER CLEAN-OUT PER MERIDIAN SD S1,SURVEYOR TO AS-BUILT INVERT PRIOR TO • CAR? BACKFILL U) \ Q W01 FIRE HYDRANT ASSEMBLY,GATE VALVE, 12"X6"TEE,6"PIPE, LENGTH PER PLAN N r X N U U 0 _ LU W W03 NON-POTABLE CROSSING,SEE SEWER NOTE#8,SHEET C0.01 0 a Z a Y of O 0 � w U C m w = o p Q \ W06 12"22.5°ELBOW U O \ IRR-BOX-02 STA:36+63.39 OFF:-50.50L w Z IR02 RIM:2572.90 W09 12"X 8"CROSS,ORIENTATION AND VALVES PER PLAN Q INV=2568.18'(12") INV IN:2568.28 12" (S) (q INV OUT:2568.28 12" (N) U) / W10 2"TEMPORARY BLOWOFF ASSEMBLY PER MERIDIAN SD-W13 2 IR01 / cr_ 13'of 12"PVC @ 0.77% W / . W12 4"TEMPORARY BLOWOFF ASSEMBLY PER MERIDIAN SD-W13 Z W \ SO / . y g \ $+00 / 3 SSCO-04 / / / W03 eo. STA=33+94.24 \ / RIM=2566.18' gp. W10 / / W INV OUT=2560.18' S p° /. 12 7+p0 I (� 0 \Z, • 4\ ( ) ±64LF 8"W / 3� W12 NOTES: z o CL U \ o /. /' ' !y 12 W N 1. EXISTING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON AVAILABLE L W s\\ \ i \ 80'of 8"PVC @ 0.50/o / ; `"::' g$'of 12"C900 @ 0.31% RECORD INFORMATION AND FIELD SURVEY.CONTRACTOR SHALL VERIFY LOCATION OF EXISTING > e�8/S \32x2'� \�/ °' ' 1' 245�F 12 W 3�� UTILITIES VIA DIG-LINE PRIOR TO START OF CONSTRUCTION. o 2. CONTRACTOR TO COORDINATE DRY UTILITY SERVICES WITH APPLICABLE UTILITY PROVIDERS. 10 W06 •W01 ±40LF 12"W :" :� 12'W / R OR y \ :."IR 1 / �,.': a.` ' •^tea,\ �.qY W03 09 35; W NAv\GA _ 0 - 3. WATER AND SEWER MAIN STUBS EXENDING OUTSIDE THE RIGHT-OF-WAY SHALL BE COVERED BY 8" \ �' `-'��±16LF 6"W ° 12'W / / A 10'WIDE EASEMENT ON EITHER SIDE OF THE MAINLINE EXTENDING 20'BEYOND THE STUBBED ?.\ S o .M IRR-BOX-01 � _ _• STA:36+73.09 OFF:50.49R MAIN. H ; ��'\\ 160 \ 33+86LF 12 �34 • " _ @ \ INV IN 2569.17 12" (S) 00 W +00 - %.'.�'... 3'of 12"PVC 0.91% INV OUT 2568 59 12 (N) j 1 SSMH 06 8„S 155 SSMH-08 v`^; ,:.; _T .." --: j 9" i ." INV=2569.29'(12") IR02 \ / \ 'r>Hj �:SSMH-07 s \ ,:;•� �" 0 • ° +84LF 8"W QQ W TEMPORARY DITCH ROUTING RUNOFF FROM THE 3: 00 Ir .. e° SOUTH TO TEMPORARY STORM POND. Joe w M Gn 64'of 8"PVC @ 0.50% W10 SEE ROAD SECTIONS DETAILS 1 AND 2 SHEET C3.05 O0 U) SSCO- SO 05 \ , D o a 00 Z STA=33+94.24 OQ RIM=2566.10' � a — U) INV 0UT=2560.10'(N) m o N Z (O C M N 0 / 00 O ` O \ O Z N _O F- Q U U- O0 20 40 80 120 Q-' w O J Z) LL w 0 Z o n ° Q 06 Z) � o � d 2575 W z ? _z � 2575 w Z W v) v - can w 00 �y 00 Ln O O N Zp � BOO Ln � � ln Ln N �- � O � � - � rLo N - -� � Olo to II - Z l//,w`j Z Lo N r a) Lo Lo O M I- N 11 N F_ V / Q + coN OMN II � _ 2Ml�1ZZ — M N II - = II II Z O U) Q Q - O — � >z >z >z > > ni> U) > > uc~n - -12"—GR—AV—ITY— < � EE E z I - - - — — — — — - - - - - - — — — — — — — — — — — — — — — — — — IRRIGATION D 2570 CROSSING 2570 Qw Q18"SEPARATION z N MINIMUM o O _ W N I— 12"W ry W w ------------ _ U LL M o O 2565 12"W 2565 W VILLAGGIO WAY— W z L z � w _ - Q cn ramr^^ > V U I z J O � LJJ 2560 2560 m a 89'of 8"PVC @ 0.50% T m — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — i — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - v � - - — — — - - - - - - - - - - - - - - - - - - - 39'of 8"PVC @ 0.50% � o Z �y— — — — — — — — — — — — — — — — — — — — — — — — — — — - - — — — — — — - - — — — — — — — — — — — — — — — — — — — — — — — — LL c \ _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - \ i m J 2555 2555 \ Q U (O Lo 0 O co N I� O 00 Lo h 00 N v (0 O 00 't °0 6 O Ln \ \ m Z �? O N N CO (n O h N O N (h I� M O V N M v V (O CO 6? O \ — 00 0) O O O O Cl 0) O O CD O O O O O O O O N N (.0 O (.0 O (.0 (0 � to \ _ r- � � P.- P.- r- r- r- ti ti ti r Ln Ln Ln Lo Ln Lo Ln Ln Ln Ln Ln Ln Ln Ln Ln Lo Ln Lo Ln Ln Lo Lo Ln Lo Lo Ln Ln Ln / N N N N N N N N N N N N N N N N N N N N N N N N N N N N \ — now z 9,� \ a O _ v _ v \ ) \ � � ATTENTION: o Of 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00 36+50 37+00 37+50 38+00 \C9S W NAVIGATOR 0 1/2 1 zz UI \ A\\ R DR IF THIS BAR DOES NOT MEASURE \ 1"ON 22x34 SHEET or 1/2" ON z \� \ 11x17 SHEET,THEN DRAWING IS UMBRIA HILLS WAY PLAN AND PROFILE `\ \\ NOT TO SCALE w Q DATE: April 29,2024 04 04 STA. 31+50 - 35+00 PROJECT: 240076 VERTICAL SCALE: 1" =4' KEY MAP SHEET: O HORIZONTAL SCALE 1" =40' 0 (WHEN PRINTED 22"X34") C4.01 N_ J 0 tww SS\rJNAL £N i,,\ST w KEYNOTES 8 56 s�05/08/24 0 J O LEFT TURN ARROW MARKING, PER ACHD STANDARD DETAIL TS-1113.010 v 9T� \OQ� U Oy OF �k. try O 8"SOLID WHILE CHANNELIZING LINE PER ACHD STANDARD DETAIL 15 TS-1112.03 NG• CAR? j^ 43511��.IF U) _ — I W VILLAGGIO WAY - :n--- _ 4 SOLID WHITE STOP BA PER ACHD STANDARD DETAIL 19 TS-1112 03 W tr of ��:•:::a �•-- 6 2 R,P - � — _ _ - - N Q Q _ _x 2 2 Q_ Z •:•I n.:�..�.. co --------- ,;;::.- ------ ------ __________ _ _ ____ ----------z' ;� ��`� _ _ _ — — TYPE III BARRICADE WITH THICKENED EDGE ALUMINUM WITH 6"-WIDE REFLECTIVE RED/WHITE "" y " " — — IAGONAL DETAILS PER ACHD SD 1132B _ Z ter}.,.:_.�,.,�. p ..� N p Z W --- w�•:::: W > Ll — — — — — — — — — 23 - :^ez+C•::v:l c -. r.T.•�I f :::::7 e^ .�;a a�_ — — _ _ _ �r D 0 W LY Q p — — — — — — — — — — — — — — — — — — — — — — — — — — — 11 p O p v O Q O 4"YELLOW TWO-WAY LEFT TURN LANE STRIPING,PER ACHD STANDARD DETAIL 13 TS-1112.02 m Q (7/18') Lf_ a: O Z 13 5 13 4"DOUBLE YELLOW CENTER LINE,PER ACHD STANDARD DETAIL 7 TS-1112.02 W _O o (n 4"YELLOW MULTI-USE PATH CENTERLINE STRIPE PER ACHD STANDARD DETAIL 24 TS-1112.03B 20 (379') 2 2 w 23 STOP SIGN PER MUTCD DETAIL(R1-1)AND STREET NAME SIGH PER MUTCD(D3-1) 0- 0 30 60 120 180 Z 20 20 w H H v LEGEND z o IL O W NEW SIGN U CL W U) U) NEW STRIPE Wo H Q NEW STREET LIGHT O 2 F- W TYPE III BARRICADE 7 = 7 O TYPE III BARRICADES, () Q WITH MOUNTED SIGN H � Z COMMERCIAL DRIVE COMMERCIAL DRIVE w (FUTURE-PRIVATE) Z) (FUTURE-PRIVATE) O o 4 SIGN LEGENDco Z H o THIS ROAD WILL BE o z EXTENDED IN THE FUTURE w a n fY � � w OR1 1-2 00 Q 60"X3X30" o a U) o � Z ma U) 20 Z o 0 Ciecm t0 M N NOTES Z 00 O `\ N O 1. ALL SIGNAGE AND STRIPING SHALL BE INSTALLED PER THE SPECIFICATIONS OF THE 2017 ISPWC, U 0 ACHD STANDARDS,AND 2009 MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES(MUTCD). w 2. ALL STRIPING SHALL BE PAINT IN ACCORDANCE WITH SECTION 1104 OF THE ISPWC. O _ 3. STREET SIGNS SHALL BE INSTALLED PER ACHD TRAFFIC STANDARDS AND SPECIFICATIONS. w v 4. CONTRACTOR TO FIELD-VERIFY LOCATION OF EXISTING STRIPING PRIOR TO NEW STRIPING. z Z) Q w J 7 11 �� o U U a�•�� 20 O z LL u_ 12- GO J�J �� v J E w 'si W^ z (f) U) z Q ui w p =W j /^ OLL 7 z z ILL N 20 O z z I— 20 'CL w Z a z a Q a W 11 �^ z W NAVIGATOR DR 7 V J Z z z �/� N CA ,,�_� � �/� vJ 20 1 v) J w U J W m > w j 7 p Q U F- > Q U) Q o Z U d LL Lu� m 5 J_ O 2 Q Z) U co Z co co Q_ z a O ATTENTION: o 0� 0 1/2 1 z 0 IF THIS BAR DOES NOT MEASURE 1"ON 22x34 SHEET or 1/2" ON z 1 1x1 7 SHEET,THEN DRAWING IS p NOT TO SCALE w Q DATE: April 29,2024 a N PROJECT: 240076 o O SHEET: 0 0 N_ J 0 KEYNOTES: ��,ss\G\ST pNA TYPE 1 STREET LIGHT,35'HIGH WITH 12'MAST ARM, O 1 INSTALL PER CITY OF MERIDIAN STANDARDS < 8 56 s�05/08/24 0 U 0, OFAe Of NOTES NG. CAR? U) U) 1. ALL STREET LIGHT CONSTRUCTION SHALL BE DONE IN ACCORDANCE wOf ry Q WITH THE CURRENT VERSION OF THE ISPWC,THE MERIDIAN N X = _ I SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC,AND THE NATIONAL w N o ! ° z °w w ELECTRIC CODE. w z a z a Y O of p 2. A STREET LIGHTING ELECTRICAL PERMIT SHALL BE OPENED PRIOR TO m w 9 v v Q _ y:�-Q ::•:F cl STARTING WORK.USE THE ONLINE CITIZEN PORTAL AT LL W VILLAGGIO WAY _ = HTTPS://CITIZENPORTAL.MERIDIANCITY.ORG/CITIZENACCESS/TO OPEN p - — — _ — — — — ---- -- --^•:::• �' . •��==-�' A PERMIT AND REQUEST INSPECTIONS. ---------_ _ _ _ — — — 3. INSTALLATION WILL REQUIRE INSPECTIONS FOR THE CONCRETE BASE �•:::•:,4 s I E Q ._. �_; '.•jam a+�- :r------------- ...� ----- -------------^•:::G: i� _ _ _ _ — — REINFORCING,BEDDING, BACKFILL,AND FOR THE POLE AND CiJ — — — — — — — --' z.=.*u�. C�: t��i-ear: —•.....t�;:�� ASSOCIATED WIRING. 4. STREET LIGHT BASES SHALL BE LOCATED 10'MIN.FROM TREES,5'MIN. w FROM FIRE HYDRANTS AND 2'MIN.FROM WATER METERS. a I 0 30 60 120 180 z 5. KEEP ACCURATE NOTES OF CONDUIT,JUNCTION BOX LOCATIONS. w g' I ATTACH A REDLINED AS BUILT DRAWING OF THIS PLAN SHEET TO THE STREET LIGHTING ELECTRICAL PERMIT,OR SUBMIT A HARD COPY TO ~ I THE MERIDIAN PUBLIC WORKS DEPARTMENT PRIOR TO REQUESTING FINAL INSPECTION. U 6. CONTACT THE CITY TRANSPORTATION AND UTILITY COORDINATOR Z O LL (208)898-5500 FOR QUESTIONS REGARDING UTILITY CONFLICTS,OR TO O_ U 1 ACCESS LOCKED METER PEDESTALS. cA w I > U c I � o O u, I LEGEND w Q 1 PROPOSED STREET LIGHT Z o J — — PROPERTY BOUNDARY z H = R/W ROAD RIGHT-OF-WAY lr_ Q � � O COMMERCIAL DRIVE COMMERCIAL DRIVE (FUTURE-PRIVATE) (FUTURE-PRIVATE) zco W Boa U) z ' 0 � I Q ma o ;r z c/) r• Cie cm t0 N M LL / v O ` 00 Q z N O S Q y U - I o I 0 t' ud O W o LL Q �— U) _ z V J �— Q GHQ\ JQ (ten W LLJ F _ LL C� \ �f a Ujr M Q w D W a \\ uX g O � o I C H - s, 1 z N ..,_... } ' A I- : ... ------- - w Q NAVIGATOR DR a Z N uj Z °> Q_ �a z � o w a O w Of ATTENTION: 0 1/2 1 zo' U O IF THIS BAR DOES NOT MEASURE 1"ON 22x34 SHEET or 1/2" ON z 11x17 SHEET,THEN DRAWING IS ° Q I NOT TO SCALE Q DATE: April 29,2024 a N PROJECT: 240076 o O SHEET: 0 7.00 N J