HomeMy WebLinkAboutL2.6 IRRIGATION DETAILS 021G UAL SURVEY ON FILE AT ACCURATE SURVEYING & MAPPING
FINISH GRADE
FINISH
GRADE o°p°p44o❑❑00000000
61 S� of ID �Ooo
z_ z LINE FLUSHING N o00°°°5
TZo oo
°o
IL ua Q VALVE #TLSOV w V) o 00
- lU R-1
Q V) o LA- 6536 ho
°o q/I-7/2025
VALVE BOX 0000 w
WEED BARRIER FABRIG SEE SPECS CSo°OO° NDSCA�o o°°° o
O
0000❑❑❑o°oo >
WHERE APPLICABLE o
Z
ti
° z
Techline LATERAL
L SPAGIN6 PER PLANS
SUB GRADE O 7�J-7 7 7 7��0� TEGHL I NE o t+1
OOOOOOOO TUBING AS ° N °
MULGH PER PLANS o O o O)00 OO o0 U c .0 N o o
SPECIFIED ON
PLANS. a 00
TECHLINE SUBGRADE Is
� �' n 3 � w
BRICK SUPPORTS O0o a` E iu g _ . r? a w
4 (THREE) I __ Q us � ; 0
INSTALLATION NOT °GALE ' 0 o ° -0 CU N °
36" SLACK WIRE ROLLED NEATLY, USE 3M DBY w Is °"° 1 3 0 co a z
WATER PROOF WIRE CONNECTORS
° UJW C7� J 3 � L CO m
• • • • • • u- a CO C7
RECTANGULAR HEAVY DUTY PLASTIC VALVE BOX FINISH GRADE 3/4" GRAVEL SUMP I _ x
K WITH LOGKIN& LID AND LABELED "IRRIGATION" (I GUBIG FOOT) 0"c O 0 00 I - • ■ z
(PROVIDE BOLTS AND SECURE PER I O O O O OO OO OO I o
MANUFACTURES RECOMMENDATIONS) BOX TO BE L O o 0 0 0 0 0 o OJ
LEVEL AND FLUSH WITH FINISH GRADE. Techline COMBINATION TEE m
5/4" 56H 80 MODEL TLO-75FTEE Q
UNION FINISH GRADE ,
Techline TUBING w z
REMOTE CONTROL VALVE AS SPECIFIED (ONE w ).M
A N UAL LINE FLUSHING VALVE °
= VALVE PER BOX) 12" MIN. VALVE DEPTH. Q
3/4" S Im
CH 8O II ;� � o NOT TO SOAVE
INSTALL FPTxFPT BALL VALVE IN VALVE BOX. °
UN IQN III III_ PLUMBED TO TUBING
(2" DIA. PIPE AND ABOVE USE SGH. 80 BALL N
J III VALVES. ANY PIPE SIZES UNDER 2 DIA. PIPE USE
z 9
SCHEDULE 40 1 IIII SGH. 40 BALL VALVES -- J °
P.V.G. LATERAL IIII ) o
LINE \ L o = LOCATOR TAPE w I w
I" CLEAR a =III III IIIAlkAROUND FILTER FABRIG BARRIERII
10
LATERAL (TYP) _— III VALVE BOX EXTENSION AS REQUIRED 5/4" MIN. -z MULCH
TRIPLE SWING JOINT III III a F
3/4" PRV LENGTH AS REQUIRED -III -� FINISH GRADE z
III PAVING BRICK (I OF 4) III III III w
M x F I.P.S z -w IN-LINE EMITTER Copyright C�2025 z
HARGO SGH 40 PVG GASKETED SERVICE TEE OR d All rights reserved. Reproduction or use in any form 0
GQUPLING M IIII III III III III III III DRIP TUBING or by any means without written permission of 2
APPROVED EQUAL OR ROMAG 202N PIPE _ x
H -III O O O O O O O O O O O O O O O O O O Breckon Land Design,Inc is unlawful and subject to 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
5/4" DISCI — g g g g g g g g, g, g, g, III SADDLE OR APPROVED EQUAL
• I II ,III„ ,III„ I I I I I I I I I I IIII I I I I IIIIII
,�, ,�,�,�� �, criminal prosecution. w
F I LTER I I I I I IIII Oo Oo Oo Oo Oo o Oo Oo Oo Oo Oo Oo Oo Oo Oo Oo Oo Oo Oo Oo Oo III w
MAINLINE AS SPECIFIED (24" MIN. BURY) PVG TEE (5x5xT)
I I I I I III III III III III III I III I I
4" MIN. OR 90° (SXT) III III III III III III;
CLEARANCE -1II-111=1II=1 II III=11 II TAPE AND BUNDLE CONTROL WIRE AT 10-0 O.G. NOTE: =1II Z10
ABOVE PEA -III INTERVALS ALONG MAIN LINE EGO INDICATOR Y
EACH CONNECTION IS CAPABLE OF MAX 10 GPM PVG OR POLY PIPING III
GRAVEL — 1—' 'III- HUNTER MODEL:
24 VOLT COMMON AND CONTROL WIRE TO DRIPLINE I O w
UNDISTURBED NOTE:
VALVE COMBINATION IIII OPERIND o
OR TECHLINE START CONNECTION TEE III III MARLEX CD
COMPACTED I. USE SGH. 80 PVG NIPPLES AND FITTINGS. 6" DEEP (MIN.) BED OF 3/8" GLEANED AND5 STREET ELBOW Z
NATIVE SOIL. WASHED PEA GRAVEL NOT TO SCALE SPIRAL IIII II II W °
REMOTE CONTROL VALVE - 0
a
11 NOT TO SGAL- MANUAL FLUSH VALVE FLEX TUBING �— N
1 IIIIIIIIIIIII,II I IIIIIIIIIII, Q coVJ
WITH 3/4 FILTER PLUMBED TO DRIPLINE TUBING _ - Q w
REFER TO START CONNECTION
II III III III II III I
36" SLACK WIRE ROLLED NEATLY, USE 3M DBY WATER SPECIFIED IFIEDLINE �ON1 LAN NC7 AS DETAIL. IIII 1 1 III r^ o
PROOF WIRE CONNECTORS co < Lu
o GHRISTY'S BLANK YELLOW ID TA6 OR APPROVED EQUAL E CO INDICATOR Q oo z
If) \10 TO `_;GALE °
( � 0
RECTANGULAR HEAVY DUTY PLASTIC VALVE BOX WITH v o
LOGKIN6 LID AND LABELED "IRRIGATION" (PROVIDE
F � CD W 0 w
L0 BOLTS AND SECURE PER MANUFACTURES
RECOMMENDATIONS) BOX TO BE LEVEL AND FLUSH WITH
FINISH GRADE.
M Z_ _ FINISH GRADE — — — —I0
I-III- I I I I I I I I IF
� I- III III I I III III I' Q � O
-0 z_ REMOTE CONTROL VALVE AS SPECIFIED (ONE VALVE / -III III III Q
o SGH. 80 — FINISH GRADE
0 NIPPLE —III PER BOX) 12" MIN. VALVE DEPTH. -IIII
ROTOR POP-UP SPRINKLER 0
SGH 40 PVG = INSTALL FPTxFPT BALL VALVE IN VALVE BOX. (2" DIA.
— —
I LATERAL (15' IIII — PIPE AND ABOVE USE SGH. 80 BALL VALVES. ANY PIPE PREFABRICATED I" SWING JOINT AS W CO
_ SIZES UNDER 2 DIA. PIPE USE SGH. 40 BALL VALVES) =III
E MIN. BURY) o —III— MANUFACTURED BY LASGO OR
APPROVED EQUAL
0) SLxFPT PVG LOCATOR TAPE W
GOUPL I NG —
I I
— FILTER FABRIC BARRIER
I" CLEAR �� 8�d � SEE DRIP NOTES AREA PERIMETER `lr/
-C _ _ - VALVE BOX EXTENSION AS REQUIRED -III T
�y AROUND 00 0 00 00 00 00 00 00 00 00 o FOR ROW SPAGIN6 LOW VOLUME CONTROL ZONE
LATERAL (TYP) -III=III- 0
0 0 0 ���3 o - PAVING BRICK (I OF 4) PERIMETER LATERALS
KIT-REMOTE CONTROL VALVE,
o 0 0 0 0 0 0 0 0 0 0 0 2" TO 4" FROM EDGE FILTER AND PRESSURE = —
REGULATOR. co
�� o 0 0 0 0 0 0 0 0 o HARGO SGH 40 PVG GASKETED SERVICE TEE OR -III III III �
0 4 MIN. 0 NOTE: I=III=III=II O
CLEARANCE I I I = =III=III = �- APPROVED EQUAL OR ROMAG 202N PIPE SADDLE OR
ABOVE PEA - APPROVED EQUAL I. CENTER FEED LITE LAYOUTS ALLOW 2X MAX " MIN PVG/POLY TUBING TO
GRAVEL TUBING LENGTH OF STANDARD LAYOUTS. CONNECTION; SIZE AS
1_I MAINLINE AS SPECIFIED (24" MIN. BURY) 2. PLACE SOIL STAPLE EVERY 3'-5' PLUS TWO ON INDICATED ON PLANS. 6
UNDISTURBED I,— I I- - EACH TEE, ELBOW OR GROSS.
TAPE AND BUNDLE CONTROL WIRE AT 10 O O.G. 3. BELOW ARE MAX LINE DISTANCE FOR CENTER
OR IIIIII 11I11I11 I1- INTERVALS ALONG MAIN LINE FEED LITE LAYOUT @ 57 PSI INLET,
3:
COMPACTED INLET; REFER TO FULL I -III III III III IIIIII PVG SGH 40 TEE OR ELL
o NATIVE SOIL. CHART FOR ALTERNATE PRESSURES: - I I I I
NOTE: 24 VOLT COMMON AND CONTROL WIRE TO VALVE SCHEDULE 40 PVG LATERAL LINE
.53 @ 12" o.c. = 1,056 .53 0 12" o.c. = 774' rr
1. USE SGH. 80 PVG NIPPLES AND FITTINGS. 6" DEEP (MIN.) BED OF 3/8" GLEANED AND WASHED PEA .33 @ 18" O.C. = 1,504' .53 @ 15" o.c. = 1,104' (MIN. 18" DEEP)
GRAVEL
REMOTE CONTROL VALVE DRIPLINE LAYOUT ROTOR POP—UP SPRINKLER
z
�, 0 2 NOT TO SCALE 6 NOT TO SCALE 1 0 NOT TG SGAI-E
�- o
CID DRIPLINE TUBING REVISIONS
v LATERAL, SNAKE No. Date Description
(0 AROUND BASE OF 1 3/11/25 MERIDIAN COMMENTS r
a) TREES AT A 18" AND v
can 36" RADIUS '
-III FINISH GRADE
BLANK TUBING TO—\
1111II I INSTALL I/4" ABOVE GRADE AND
SUPPLY HEADER - PROJECT NO.:
o - _ 'NDS' VALVE BOX, OR APPROVED A MINIMUM OF 4" OFF WALKS I
_ EQUAL. SET BOX FLUSH WITH z AND CURBS 24054 V,
B < III 1 FINISH GRADE, PROVIDE I1111111I I I I = POP-UP SPRAY HEAD DRAWN BY: z
- — - — EXTENSIONS AS REQUIRED -
III 00 1 1 TREE TRUNK N —dial III CR. KS O
I 1/2" MARLEX STREET ELLS
IIII (IIII II BALL VALVE, OR APPROVED q0°ELL SPIRAL BARB � CHECKED BY:
EQUAL. FITTIN65 LINEAR LOW DENSITY U
2" MIN. POLYETHYLENE SWING PIPE (12" DATE:
= = PVG MAIN LINE SCHEDULE 40 PVG—-____' LONG MIN., 18" LONG MAX) 09/17/2025 C*
NOTE: LATERAL LINE
I. TO BE USED AT ALL TREES PLANTED (MIN. 12" DEEP) 0
THREADED FEMALE ADAPTOR, WITHIN AREA NOTED ON PLAN. SHEET NUMBER O� �I III III -III III III III 1 I III 1 SCHEDULE 40 FITTINGS T
0 111 111 III11' TYPICAL 1 „III „I
A � —III= III III� III III III III III
0, ISOLATION VALVE DRIPLINE LAYOUT L2.6
Of 3 NOT TO SGAL NOT T°7 SPRAY HEAD POP-UP SPRINKLER
ATTREES rGAI-- 11 NOT TO sG L_-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15