HomeMy WebLinkAboutL2.0 IRRIGATION PLAN 021G NAB SURVEY ON FILE AT ACCURATE SURVEYING & MAPPING o�o� K. cOF�ID���Oo VALVE SCHEDULE IRRIGATION SCHEDULE °° �� ����� °°° a UMBER MODEL SIZE TYPE GPM SYMBOL MANUFACTURER/MODEL/DESCRIPTION o LA- 6536 cwg o Hunter PRO5-04-PR530-GV-R 8' radius, 10' radius, 12' ci/I7/2025 o° I Hunter IGV-G 2" Turf Rotor 16.75 radius, 15' radius and 17' radius. o°oo lj oo°o 2 Hunter IGV-G 2" Turf Rotor 5.5 H H H H H Turf Spray, 30 psi regulated 6.0" Pop-Up. With Check 00000°O�aoo 0�ado 00o j 3 Netafim LVGZ58010075-HF Ir Area for Dripline 7.32 Valve, and Purple reclaimed cap. See detail II/L2.6. 4 Netafim LVGZ58010075-HF I" Area for Dripline 6.8 Hunter I-20-04-SR-R 0.5 0.75 1.5, o 5 Netafim LVGZ58010075-HF I" Area for Dripline 4.43 Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Plastic 0 6 Hunter IGV-G 2" Turf Rotor 17 0 0 Riser. Drain Check Valve. Short Radius Nozzle. With W L 7 Netafim LVGZS8010075-HF I" `C�'Area for Dripline 7.08 Reclaimed Water Purple ID Cover. See detail 10/L2.6. 8 Hunter IGV-6 2" Turf 5 ra 20.17 o M Cl Netafim LVGZ58010075-HF I" Area for Dri Ilne 10.44 Hunter P6P-04-GV-R 1.5, 2.0, 4.0, 6.0 o N ° 21 10 Netafim LVGZ58010075-HF I" Area for Dripline II.84 ® ® ® ® Turf Rotor, 41n. Pop-Up. Adjustable to Full Circle. With C) ° � N II Hunter IGV-G 2" Turf S ra 18.04 Drain Check Valve, and Reclaimed Water Purple ID. See Y c I tb iD o m ° 12 Netafim LVGZ58010075-HF I" Area for Dripline G.GI detail 10/L2.6. .E _ _� n /n� z II 'L L a E U) O CO 4-/ N (0 W 13 Hunter IGV-G 2 Turf 5 ra 20.51 ru a cn E � co W (D aCD w 14 Netafim LVGZ58010075-HF I" Area for Dripline 5.38 Q 0 �� � � ; 0 IS Hunter IGV-G 2 Turf S ra 28.ga Netafim LVGZ58010075-HF m II U 00 C U.0 N L W UI.0L �'-' W 2aoN OU o Pre-Assembled Control Zone Kit, with lin. Series 80 Control _ -a �, Q o � z r- ib Netafim LVGZ58010075-HF I" Area for Dripline 10.55 > E o .m E 3 Cu ) 1-7 Netafim LVGZ58010075-HF I" Area for Dri line 10.52 Valve, 3/4in. Disc Filter, and High Flow Pressure Regulator � 30 Lu CD SE 3 3 ,, L cco 18 Hunter IGV-G 2" Turf Rotor 2a.8 4.56PM to 17.66PM. See detail I and 5/L2.6. 3 u- W co cD N LL la Hunter IGV-6 2" Turf 5praq 6.04 Area to Receive Dripline . _ ■ - K 20 Netafim LVGZ58010075-HF I" Area for Dri line 12.84 Netafim TLHGVXR-G5-077-12 21 Hunter IGV-6 2" Turf Rotor 7.5 5ee drip material legend Techline HGVXR-G5 Pressure Compensating Landscape o 22 Hunter IGV-6 2" Turf 5praq Ici.02 Dripline with Copper Stripe, Check Valve and Anti-Siphon = 23 Netafim LVGZ58010075-HF I" Area for Dripline 11.1 feature. 0.77 &PH emitters at 12" O.G. Dripline laterals m 24 Netafim LVGZ58010075-HF I" Area for Dripline 13.73 spaced at 12" apart, with emitters offset for triangular , 25 Hunter IGV-6 2" Turf 5prog 13.64 pattern. 17mm. See detail 4, 6 and 7 L2.6. 26 Netafim LVGZS8010075-HF I" Area for Dripline 12.65 Hunter EGO-ID 27 Netafim LVC-ZS8010075-HF I" Area for Dripline 11.2 EGO-ID: 1/2in. FPT connection with 12 psi-70 psi operating o 28 Netafim LVGZ58010075-HF I" Area for Dripline a.47 O pressure. Specify with Hunter SJ swing joint. See detail Q 24 Netafim LVGZ58010075-HF 1" Area for Dripline 11.0 30 Netafim LVGZS8010075-HF I Area for Dri Ilne 10.66 Hunter IGV-6 J lin., 1-1/21n., 21n., and Sin. Plastic Electric Remote Control Valves, 61obe Configuration, with NPT Threaded Inlet/Outlet, Z for Gommercial/Municipal Use. See detail 2/L2.6 ° Hunter 12C-4000-M ' © 40 Station Outdoor Modular Controller. With four IGM-800 w Module. Commercial Use. Metal Cabinet. See detail I/L2.5. Hunter W55 o I Wireless Solar, rain freeze sensor with outdoor interface, connects to Hunter PGC, Pro-C, and I-Gore Controllers, w I ® install as noted. Includes 10 year lithium battery and rubber module cover, and gutter mount bracket. See detail 2/L2.5. Copyright©2025 I Z All rights reserved. Reproduction or use in any form °w or by any means without written permission of 2 H Isolation Valve. See detail 3/1-2.6. Breckon Land Design,Inc.is unlawful and subject to 0 criminal prosecution. POI Point of Connection 3/4" , See detail 5 and (6 /L2.5 I a r< o �>e _ Irrigation Lateral Line: PVG Schedule 40 R GIRR GIRR GIRR GI GIRR R GIRR R GIRR ==; Only lateral transition pipe sizes I" and above are indicated ° GI�r< � '� z on the plan, with all others being 3/4". Y O W xxxx:: 2" Irrigation Mainline: PVC, Schedule 40, see detail 4/L2.5 0 77� xxxxxx xxxxxxx w \\ xxxxxxx ^ \ % xxxxxx v) \ ixlxexxx Z 01) �!� x;;;; _ _ _ _ _ _ _ = Pipe Sleeve: PVG Schedule 40. See detail 3/L2.5 L G H � F7 ����� � xxxx � W ' xxx C\J 0 �O == xx Gap for future use \\\� / f� Gap at the mainline or lateral line for future use. The 0 s;, pressure and flow provided to that location are indicated o Poc it next to the cap symbol W 10 \\\ Valve Callout w W � ,. \ Valve Number w 0- J W Valve Flow r n z v I n ° N II W Valve Size 1..` a Z & W II I rnn / O 1 W V / II II po� z - Q Q w 0 I I III � Q I wCO POC 2 r 10 _ N w DC o o I W D Id,.t, ldgl� - d MAP Q T C C �� ���� �������������� C '� 11 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 C C'1 �xCu �����"����•✓• C POC4 ,.pT , ......, .... 1� �1'I'1'I'1'll,l ,I,I I I I 1 �... _ v o ------------------------------------------ W 8" W8' W8" W8" W8" �P8" E ESCALATION DRIVE E ESCALATION DRIVE - � O o - z Q 0 0 o � z co � � REVISIONS No. Date Description 1 3/11/25 MERIDIAN COMMENTS ( , QC) L.L I PROJECT NO.: C140 24054 (n B C- DRAWN BY: z CR. KS O CHECKED BY: - - - - - - - - CR, JB DATE: o 09/17/2025 C* O C SHEET NUMBER CD A IRRIGATION PLAN T T 0, Nl E 50 0 50 100 150 L2.0 al SCALE: I"= 50'-0" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15