Loading...
HomeMy WebLinkAboutL2.02 Irrigation Plan Area B IRRIGATION SCHEDULE IRRIGATION SCHEDULE Irrigation Notes: �� �,._., A. SYSTEM DESIGN BASED ON THE ASSUMPTION OF THE AVAILABILITY OF 60 G.P.M. i1 �WE �i''�� T H E SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI DETAIL SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL AND 65 P.S.I. WFIALAN D HUNTER PROS-06-PRS30-CV 10 SERIES HUNTER ICV-G-FS B. CONTROLLER IS LOCATED IN PHASE 1 AREA. ALL VALVES SHALL CONNECTED TO TURF SPRAY, 30 PSI REGULATED 61N. POP-UP. WITH FACTORY INSTALLED 11N., 1-1/21N., 21N., AND 31N. PLASTIC ELECTRIC REMOTE CONTROL VALVES, TWO-WIRE LEADING BACK TO CONTROLLER. . a10 1H 10 DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT 30 8/L2.50 GLOBE CONFIGURATION,WITH NPT THREADED INLET/OUTLET, FOR 6/L2.50 C. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANY -� GROUP MATERIAL. COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY. DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING ' HUNTER PROS-06-PRS30-CV 12 SERIES SHUT OFF VALVE 4/L2.50 UTILITIES SHALL BE CONTRACTOR'S RESPONSIBILITY. TURF SPRAY, 30 PSI REGULATED 61N. POP-UP. WITH FACTORY INSTALLED D. COORDINATE ALL IRRIGATION INSTALLATION OPERATIONS WITH CIVIL, 1H 12 1H 1F DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT 30 8/L2.50 MECHANICAL, AND ELECTRICAL ENGINEERING SHEETS. ' MATERIAL. Op DRAIN VALVE 5/1-2.50 E. CONTRACTOR TO COORDINATE INSTALLATION OF IRRIGATION CONDUIT AND HUNTER PROS-06-PRS30-CV 17 SERIES SLEEVES UNDER HARD SURFACES WITH RESPECTIVE CONTRACTORS. TURF SPRAY, 30 PSI REGULATED 61N. POP-UP. WITH FACTORY INSTALLED F. ALL SLEEVES TO BE INSTALLED AS PART OF IRRIGATION CONTRACT. ' 17 17 30 8/L2.50 EXISTING MAINLINE CAP EXTENSION APPROXIMATE LOCATION OF SLEEVES ARE SHOWN ON THE IRRIGATION PLAN. o H DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT EXTEND NEW MAINLINE DOWNSTREAM OF EXISTING MAINLINE CAP. FIELD VERIFY LOCATION. ALL ENDS OF SLEEVES TO BE TAPED OR CAPPED AND MATERIAL. T SADDLE TAP MARKED WITH A 2"X 4" PAINTED STAKE EXTENDING TO 24" ABOVE GRADE. HUNTER PROS-06-PRS30-CV ADJ SERIES SADDLE TAP INTO EXISTING PRESSURE IRRIGATION MAINLINE. UTILIZE 1/1-2.50 TURF SPRAY, 30 PSI REGULATED 61N. POP-UP. WITH FACTORY INSTALLED STAKES ARE NOT TO BE REMOVED UNTIL THE IRRIGATION SYSTEM IS COMPLETE.(1) © ® 10 12 a 17 30 8/L2.50 LEEMCO RSST SERIES SADDLE TAP MODEL RSST-604,AND RSST-804. ALL SLEEVES SHALL EXTEND A MINIMUM OF 18" BEYOND BACK OF CURB OR EDGE DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT IRRIGATION LATERAL LINE: PVC SCHEDULE 40 OF PAVEMENT. PROVIDE COMPACTED BACKFILL. JHUNTER PROS-I2-PRS30 CV 8 SERIES PVC SCH. 40 PIPE SHALL BE USED WITH SOLVENT WELD SCH. 40 FITTINGS 2/L2.50 G. CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR � � SHRUB SPRAY 30 PSI REGULATED 121N POP-UP WITH FACTORY FROM 1/2"-2-1/2" PIPE SIZES.ALL PIPE 3"AND ABOVE SHALL BE CLASS THIS WORK. 1 ® 12) , . .0) ® 30 8/L2.50 200 WITH DUCTILE JOINT RESTRAIN FITTINGS BY LEEMCO. H. IRRIGATION CONTROLLER(S) ARE TO BE LOCATED AS SHOWN ON PLAN. Q T H F INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV IRRIGATION MAINLINE: PVC SCHEDULE 40 CONTROLLERS SHALL BE WIRED TO POWER SUPPLY BY A LICENSED ELECTRICIAN _ _ RESISTANT MATERIAL. ����� PiRF� J PVC SCH. 40 PIPE SHALL BE USED WITH SOLVENT WELD SCH. 40 FITTINGS PER LOCAL CODES. IRRIGATION CONTRACTOR TO PROVIDE ALL REQUIRED - HUNTER PROS-I2-PRS30-CV 10 SERIES FROM 1/2"-2-1/2" PIPE SIZES.ALL PIPE 3"AND ABOVE SHALL BE CLASS 2/1-2.50 CONNECTIONS TO 24 VOLT IRRIGATION CONTROL WIRE INSIDE THE BUILDINGS 1 = 1- 1 T1 I I I I I I I I I I I El ED SHRUB SPRAY, 30 PSI REGULATED 121N. POP-UP. WITH FACTORY THROUGH APPROPRIATE SIZED CONDUIT. 10 10 E) 10 10 O 30 8/L2.50 200 WITH DUCTILE JOINT RESTRAIN FITTINGS BY LEEMCO. Q T H F INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV PIPE SLEEVE: PVC CLASS 200 SDR 21 1. IRRIGATED AREAS CONTAINING VEGETATION WHICH POTENTIALLY MAY IMPEDE c RESISTANT MATERIAL. PIPE SLEEVE SHALL BE TWICE THE SIZE OF DESIGNED PIPE DIAMETER FOR PERFORMANCE OF A POP-UP SPRINKLER AND/OR ROTOR HEADS ARE TO BE N MAINLINE AND 4" FOR LATERAL LINES INSTALL ADDITIONAL 2"SLEEVE AT 3/L2.50 REPLACED WITH A 12" HIGH POP-UP HEADS. . SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM DETAIL J. ALL ELECTRICAL WORK TO MEET OR EXCEED N.E.C., STATE CODES, LOCAL CODES, 6 GB ALL MAINLINE SLEEVES FOR CONTROL WIRES OR WHERE CONTROL WIRE HUNTER 1-20-06-PRB-MPR 25 AND MANUFACTURER'S RECOMMENDATIONS. 25 TURF ROTOR, 61N. POP-UP. ADJUSTABLE AND FULL CIRCLE. PLASTIC 45 7/L2.50 LEAVES MAINLINE ROUTE. K. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL ROCK AND DEBRIS BROUGHT RISER. DRAIN CHECK VALVE. MPR NOZZLE. PRESSURE REGULATING BODY. Valve cauout TO THE SURFACE AS A RESULT OF TRENCHING OPERATIONS. HUNTER 1-20-06-PRB-SR 0.5 Valve Number L. CONTRACTOR SHALL REFER TO SPECIFICATIONS AND DETAIL DRAWINGS FOR TURF ROTOR, 61N. POP-UP. ADJUSTABLE AND FULL CIRCLE. PLASTIC # # Valve Flow ADDITIONAL REQUIREMENTS. 0.5 RISER. DRAIN CHECK VALVE. SHORT RADIUS NOZZLE. PRESSURE 50 0.5 7/1-2.50 M. ALL 24 VOLT POWER WIRES SHALL BE #14 AWG COPPER. ALL ABOVE GROUND $ " Valve Size REGULATING BODY. 120 VOLT AND 24 VOLT WIRE SHALL BE IN PVC CONDUIT. ALL 24 VOLT WIRES HUNTER I-20-06-PRB-SR 1.0 SHALL BE TAPED TOGETHER AT TEN FOOT(10'-0") INTERVALS. - - - - - - - - - - TURF ROTOR, 61N. POP-UP. ADJUSTABLE AND FULL CIRCLE. PLASTIC N. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS 0 RISER. DRAIN CHECK VALVE. SHORT RADIUS NOZZLE. PRESSURE 50 1 7/1-2.50 AND ORDINANCES. REGULATING BODY. 0. IRRIGATION CONTRACTOR SHALL PROVIDE AN AS-BUILT IRRIGATION PLAN UPON COMPLETION OF INSTALLATION AND PRIOR TO FINAL PAYMENT. 25 HUNTER 1-20-12-PRB-MPR 25 P. THE ENTIRE SYSTEM SHALL BE GUARANTEED TO BE COMPLETE AND PERFECT IN Q SHRUB ROTOR, 121N. POP-UP.ADJUSTABLE AND FULL CIRCLE. PLASTIC 45 7/1-2.50 EVERY DETAIL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ITS ACCEPTANCE; PHASE 1 RISER. DRAIN CHECK VALVE. MPR NOZZLE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR SHALL BE FREE OF EXPENSE TO THE OWNER. Q. AS PART OF THIS CONTRACT, PERFORM AT NO EXTRA COST WINTERIZATION AND SPRING START UP OF THE SYSTEM DURING THE GUARANTEE PERIOD. ' `o R. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS OF THE W QUALITY AND PERFORMANCE SPECIFIED, AND SHALL MEET THE REQUIREMENTS ' OF THIS SYSTEM. USE MATERIALS AS SPECIFIED, NO SUBSTITUTIONS SHALL BE CA PERMITTED WITHOUT PRIOR WRITTEN PERMISSION OF THE OWNER. S. IRRIGATION CONTRACTOR SHALL MAKE NECESSARY MINOR FIELD ADJUSTMENTS 44 TO SPRINKLER NOZZLES, SPRINKLERS PIPE, AND OTHER IRRIGATION EQUIPMENT LOCATIONS TO FIT THE AS-BUILT SITE. ADJUST HEAD AND PIPE LOCATIONS AS 4 3 1 1 3 4 ' REQUIRED TO AVOID DAMAGING EXISTING TREE ROOTS. ADJUSTMENTS SHALL 2" ENSURE HEAD TO HEAD COVERAGE. " 6"P1 R 10 10 10 BEGIN 6 P IRR BEGIN 10 d 10 10 0. 0.5 � RR T. IRRIGATION PIPING LAYOUT IS SCHEMATIC. WHERE LINES ARE SHOWN BELOW ill 4 1 PAVEMENT ADJACENT TO LANDSCAPE AREAS, THEY ARE TO BE LOCATED IN THE ' 4 13.6 1 10 10 62 2 7 10 110 1 LANDSCAPE AREA UNLESS SHOWN WITH A SLEEVE SYMBOL. 10 10 10 10 10 io 1.0 1.0 „ 1 14' 1Ya° 1° T.A. IRRIGATION MAINLINE SHALL BE SLEEVED UNDER ALL HARDSCAPE. Z 0 10 10 10 1 1%° 1 17.1 6 10 10 1 1i 10 10 , SLEEVING MAY NOT BE SHOWN FOR MAINLINE FOR GRAPHICAL PURPOSES. 10 10 4 10 10 7 17.1 U. LOCATION OF EXISTING EQUIPMENT ARE SCHEMATIC IN NATURE. FIELD VERIFY O LJJ o 10 1" 1 ALL BASE AND EXISTING IRRIGATION ELEMENTS AND CONDITIONS PRIOR TO cc 10 a, 10 10 5 14.5 1Y„ 10 10 END 10 10 � , o CONSTRUCTION AND PROVIDE NECESSARY ADJUSTMENTS. CA 10 10 10 1 10 10 10 10 N V. IN THE EVENT OF A DISCREPANCY, IMMEDIATELY NOTIFY THE LANDSCAPE LJJ t.o 1.0� � LJJ ARCHITECT. � o C ' 1a 10 V. 10�10 10 10 W. CONTRACTOR SHALL SCHEDULE A MEETING WITH LANDSCAPE ARCHITECT AND 10 y� 1010 1° _ , OWNERS REPRESENTATIVE PRIOR TO INSTALLATION OF IRRIGATION CONTROL O 1.0 1.0 10 10 10 10 10 Z 10 SYSTEM TO DETERMINE PROCEDURES OF INSTALLATION OF IRRIGATION CONTROL Q 10 10 SYSTEM. w X. PIPE VELOCITIES SHALL NOT EXCEED 5 FT/SEC. y 1.0 1.o V 10 10 1010 Y. AREAS WHERE FULL CIRCLE HEADS ARE REQUIRED, NON REVERSING CIRCLE _ 10 m 10 HEADS SHALL BE INSTALLED. PARTIAL CIRCLE HEADS WITH REVERSING CD Z 10 10 DIRECTION ARE PROHIBITED FOR USE OF 360°ROTATION. - J Z I Z. FOR MAINLINE 3-IN AND LARGER, ALL FITTINGS SHALL BE LEEMCO DUCTILE IRON y - - - - - - I ' - - - - - - - PUSH ON TYPE AND ARE TO BE JOINED USING LEEMCO JOINT RESTRAINT 0. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SYSTEMS. INSTALL PER MANUFACTURERS RECOMMENDATIONS. - - - - - - - "- - _ � AA. PROVIDE AND INSTALL GROUNDING ALONG THE TWO WIRE PATH PER FVVY'. . �.` o.�.' �.".`.'. .'.�.� �.'��.'. .�.`. .'.�. �.`.a.�." . .'.�.�.�.�.' MANUFACTURERS RECOMMENDATIONS. . . W `O 01 `a" AB. REFER TO SHEET L1.00 FOR SITE WORK PHASING, AND COORDINATION WITH . W WORK BY OTHERS. � Q W cc co W. LESINA CT. - - - W W W Irrigation Execution: _ 00 O A. REMOTE CONTROL VALVES: A.A. INSTALLED (1) REMOTE CONTROL VALVE PER VALVE BOX. ENSURE THAT ADEQUATE SPACE IS PROVIDED AROUND ENTIRE VALVE FOR EASE OFR/w " " o " "Q" "o" MAINTENANCE. ROUND VALVE BOXES ARE NOT PERMITTED. co A.B. VALVE BOXES SHALL BE GREEN OR BLACK WITH GREEN LIDS. Co 2� - - - - - - - B. IRRIGATION CONTROL WIRE: - - - W _ B.A. Revisions 1 CONNECTERS AND- - - - - - - a `'�� - DBY/R CAP OR BLAZING NUT WIRE SPLICE CONNECTOR 17 1 5 END - - _ _ \ B.B. ALL WIRE SPLICES SHALL BE LOCATED IN VALVE BOXES AND INDICATED ON 1. AGENCY COMMENTS- 10/24/25 AS-BUILT DRAWINGS. PROVIDE AS A MINIMUM, 36"OF EXTRA WIRE AT ALL 11j" 1Y" � I 19 24.8 � � - \ � � WIRE SPLICES AND REMOTE CONTROL VALVE CONNECTIONS. 1 1X" 1 B.C. CONTROL WIRE SHALL BE INSTALLED WITH PROPOSED MAINLINE. IF CONTROL 10 10 10 0 11„ 17 1„ 17 19 1)/222 14.7 \ ' WIRE LEAVES PIPING TRENCH,WIRE SHALL BE INSTALLED AT A MINIMUM 1 10 10 10 1„ 20 1„ 1" DEPTH OF 12". 23.5 16 10 21 20 24.4 C. PIPING USE THE FOLLOW): 1" 1 10 1Y 17 17 1 0 22 C.A. 2(1/2"AND SMALLER I SDR 21 SCH.40 PVC, SOLVENT-CEMENT JOINTS: 1 1 10 4 14' 10 1" 23 1/ 23 7.88 C.B. 3"AND LARGER I SDR 26 CLASS 200 RUBBER GASKETED PVC WITH DUCTILE 1" 10 END 10 17 17,i 1" 1" IRON JOINT RESTRAINT SYSTEM, LEEMCO OR APPROVED EQUAL. 37.4 17 1 10 1 10 0 i 5 BEGIN 21 9.92 C.C. TRENCHES SHALL BE PHOTO DOCUMENTED AND SUBMITTED ARCHITECT 1%" 1 1Y2" 4 2" 1 PRIOR TO BACKFILLING. 1 10 10 16 17 C.D. BACKFILL TRENCHES CONSISTING OF SAND, FINE GRAVEL OR SELECT EARTH p 1 12 12 2 3 I I FREE OF LARGE LUMPS OR ROCKS LARGER THAN%"SHALL BE USED IN AND N 56.4 18 1 10 10 2 17 1'/a" 1p 1 AROUND INSTALLED PIPE. 10 12 12 2 10 10 182X2 1p 10 12 12 1" CALLOUT NUMBERS COORDINATED 14" PIRR 1Yn 1"6 PIRR 6 PIRR _. P� P� "PIRR 6"P 1" 1Y„ P� P� RR 1Ya" 1Yz" _ 6"PIRR 1Y"-2" RR . � 10 10 ���, 10 Keynotes: # TO NUMBERED NOTES BELOW _ °� P� _ PIRR 6"PIR 10 10 ; 10 �� 10 . ' 10; 10 10 10 10 �, 10 "� 10 '' 10 10 � 10 10 10 r� 10 ;"; 10 10 10 10 10 10� 10 � 10`� ''10 1 � `' 0 10 10 10 10 10 10 1 '10 10 10 r 10 10 10 10 ; 10 10 10 10 10 10 10 10 10 1 10 - - 1U 10 - - gV� �EjOF 1" � .. __ " > ,, �, �� : ,<, " . -� . 10 10 10 10 10 10 10 1 a 18 $., $ ,. MAINLINE. P q � .. � � �,, �, � � _. �4 _. ,, .* , .. �.... ;� � :$ . $ $„ $ 6 PIRR 0 � FIELD LOCATE EXISTING PRESSURE IRRIGATION SADDLE TAP ON 10 EG �G 10 I I 1 3 4 1 EG $ EXISTING MAINLINE AND EXTEND NEW MAINLINE PER PLANS AND DETAILS. EG G EG EGJll �G = a e 2. FIELD LOCATE EXISTING PRESSURE IRRIGATION MAINLINE CAP. CONNECT NEW E T1_ 7-fE E G 6 1 6 BEGIN 6 s ��, s\\ MAINLINE AND EXTEND PER PLANS. _ to I I R IRR IR I I E I G E 10 1 a 3. FIELD LOCATE EXISTING TWO-WIRE ALONG EXISTING PRESSURE IRRIGATION RR 10 4 10 "AA I IRR s MAINLINE. SPLICE NEW TWO-WIRE ALONG NEW MAINLINE AS SHOWN ON PLANS. 2 \ 1Y�� 1h" " 2" 2� - 4 LA-16589 2 1 1" 5 1y" 1Y' 1Y" 1Y" 2 2 i �" 10 10 T ALL SPLICES TO BE INSTALLED INSIDE OF 10-IN ROUND VALVE BOX AND USE DBY 5 25 2� 2 25 5 25 2 \ WATERPROOF CONNECTORS.. i� ,L °26' 7.62 10 10 J 10 10 25 4. SHOWN IN HARDSCAPE FOR GRAPHICAL PURPOSES ONLY. INSTALL MAINLINE, �/�`�NDSCA,,? VALVES, AND LATERALS IN ADJACENT COMMON LOT LANDSCAPE AREA. 10/2z4/2025 5. SHOWN IN PRIVATE LOT FOR GRAPHICAL PURPOSES ONLY. INSTALL MAINLINE, \ VALVES, AND LATERALS IN ADJACENT COMMON LOT LANDSCAPE AREA. Project No.: 123200 TOE 6. PRESSURIZED IRRIGATION LATERAL CROSSING OF GRAVITY IRRIGATION PIPE. Date of Issuance: 09.02.2025 Project Milestone: PERMIT TOP CD Irrigation Plan Area B Irri ation Plan-Area B 3°' 6°' s� - g Horizontal Scale: 1" = 30' L2mO2