Loading...
HomeMy WebLinkAboutC7.01 Utility Plan Area A Sheet Notes: .,� ,�_.. ' THE 1. ALL CONSTRUCTION AND MATERIAL SHALL BE IN ACCORDANCE WITH THE IDAHO C. w w STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), CITY OF MERIDIAN LAND STANDARDS,AND ADA COUNTY HIGHWAY DISTRICT STANDARDS. NO EXCEPTIONS ARE . 00PERMITTED WITHOUT PRIOR APPROVAL. - GROUP cn CIO cc 2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN 6"PIRR _ _ 6"PIRR _ _ APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL COMPLY WITH IDAHO CODE, I CHAPTER 22,TITLE 55 REGARDING UNDERGROUND FACILITIES DAMAGE PREVENTION. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE w w 6"PIRR 6"PIRR PHASE 1 6"PIRR 6"PIRR 6"PIRR 6"PIRR FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED AS A RESULT OF FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES. THE CONTRACTOR PHASE 2 SHALL CONTACT THE APPROPRIATE UTILITY COMPANIES OR DIG-LINE (208.342.1585) m I I a FOR EXACT LOCATIONS A MINIMUM OF 48-HOURS PRIOR TO DIGGING. 00 v 1 1 5 3. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB AND GUTTER, STORM DRAIN, B2 L26 CHANNEL CROSSINGS,AND SEWER ELEVATIONS OR INVERTS PRIOR TO cc 7,859-SF i2'1 CONSTRUCTION AND NOTIFY ENGINEER WHEN ELEVATIONS OR INVERTS DO NOT MATCH zo 81-LF 8-IN C900 W PLANS. cJ w woo W I 1 ?j B2 L27 c/�= co 4. ALL PIPE INSTALLATION AND TRENCHING SHALL CONFORM TO THE LATEST EDITION OF B2 L25 B2 L24 B2 L23 B2 L22 B2 L21 B2 L20 B2 L19 I THE ISPWC DIVISION 300 AND SD-301. BEDDING AND BACKFILL SHALL BE CD I 1 10,065-SF - - - -- \\ 6,578 SF 6,600 SF 6,600 SF 6,600 SF 6,600 SF 6,600 SF 6,600 SF I Z CONSTRUCTED PER SECTIONS 305 AND 306 OF THE ISPWC. m i 3.2 W 5. ALL BENDS AND TEES SHALL HAVE THRUST BLOCKS PER ISPWC SD-403. CDCD / R Z 11 6-IN C900 / \ 6. LABEL/TAG EACH WATER METER SETTING WITH LOT AND BLOCK SERVED BY METER. _ / 4 40 LF 8-IN C900 I METER SHALL HAVE TRAFFIC RATED LID. a 1 w w �' �� 13-LF 6-IN C900 3.2 3.2 3.2 3.1 4 _ - - - - - - - - - - - - - - - - - - - - - - -- - - - _ 7. MINIMUM COVER OVER WATER LINES UNDER SECTION-LINE AND MID-SECTION LINE 1 `o �/ MT M7 MT 2 2 2 2 2 2 2 ROADWAYS SHALL BE FIVE FEET FROM TOP OF PIPE TO FINISHED GRADE. IN ALL OTHER AREAS, COVER SHALL BE FOUR FEET. e 21-LF 8-IN C900 8. GROUNDWATER DATA BASED ON GEOTECHNICAL EVALUATION 2240-ID PERFORMED BY e-7 2 GEOTEK, INC. ON APRIL 20, 2021 AND SUBSEQUENT GROUNDWATER MONITORING 1 OBSERVATIONS. r-- - -- - --- 8"W 8"W 8"W811 8"W 8"W8w � 154-LF 8-IN C900 N 418-LF 8-IN C900 W. LESINA ST. 9. ACHD STAFF SHALL VERIFY THE INFILTRATION RATE AFTER THE FACILITY IS FULLY 39- 8-IN C900 s. " S 8"SS T 8"SS � 8"SS 8"SS 8" S 8"SS EXCAVATED. --- - -- - 2 2 2 2 2 cc 7 2 2 10. CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY IF GROUNDWATER IS a 6 ENCOUNTERED WITHIN 3-FT OF THE BOTTOM DESIGN ELEVATION FOR ANY INFILTRATION FACILITY AND/OR IF IT IS HIGHER THAN ANTICIPATED. I 3.2 8.2 y I 1 11. ALL WATER UTILITY PIPE, STRUCTURE,AND FITTING JOINTS SHALL HAVE SBR GASKETS CD CD � � - - - -- - - - -- - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - -- - - - - - - - - - - - - - - - - --- -- - - - INCLUDED AT THE POINT OF CONNECTION. HDPE PIPE NOT ALLOWED UNDER PAVERS. w w 3.2 8.4 9.2 3.2 3.2 \ 3.2 Water Keynotes: ��, Cy 1. POTABLE/NON-POTABLE WATER MAIN CROSSING. SEE CITY OF MERIDIAN WATER NOTE I � B2 L29 1 NO. 1 ON THIS SHEET FOR MORE INFORMATION. cc Cl- 8,335 SF B2 L31 B2 L32 B2 L33 B2 L34 B2 L35 B2 L36 B2 L37 B2 L38 B2 L39 2. POTABLE/NON-POTABLE WATER SERVICE CROSSING. SEE CITY OF MERIDIAN WATER y B2 L30 6,738-SF 6,848-SF 6,858-SF 6,869-SF 6,879-SF 6,889-SF 6,899-SF 6,909-SF 6,920-SF NOTE NO. 2 ON THIS SHEET FOR MORE INFORMATION. CD LU w 6,144-SF 3. WATER METERS Cc 3.1. INSTALL 1-IN SINGLE WATER SERVICE CONNECTION PER CITY OF MERIDIAN 1 STANDARD DRAWING W2 WITH SERVICE MARKER PER CITY OF MERIDIAN 1 STANDARD DRAWING SW3. MINIMUM SPACING BETWEEN WATER SERVICES IS O I 18-IN. y y 3.2. INSTALL 3/4-IN DOUBLE WATER SERVICE CONNECTION PER CITY OF MERIDIAN ' a a STANDARD DRAWING W3 WITH SERVICE MARKER PER CITY OF MERIDIAN cc °C a a STANDARD DRAWING SW3. MINIMUM SPACING BETWEEN WATER SERVICES IS cc co 18-IN. 6"PIRR 6"PIRR 6"PIRR 6"PIRR - 6"PIRR 6"PIRR 6"PIRR - 6"PIRR 6"PIRR 6"PIRR 6"PIRR 4. INSTALL FIRE HYDRANT PER CITY OF MERIDIAN STANDARD DRAWING W8. O I 5. REMOVE AND DISPOSE EXISTING BLOW-OFF ASSEMBLY. CONNECT TO EXISTING WATER ■ EG - EG EG EG - EG EG EG EG EG EG EG EG EG EG EG MAIN PER ISPWC AND MERIDIAN PUBLIC WORKS STANDARD (SHOWN APPROX.). CONFIRM PIPE SIZE,TYPE AND CONDITION PRIOR TO CONSTRUCTION, INFORM O ENGINEER OF ANY DISCREPENCIES. COORDINATE WITH CITY OF MERIDIAN PUBLIC ■ EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG WORKS AS REQUIRED. IRR GIRR GIRR GIRR GIRR GIRR GIRR IRR GIRR GIRR GIRR GIRR GIRR � 6. CITY OF MERIDIAN UTILITY EASEMENT. ■ y 7. INSTALL BEND WITH THRUST BLOCK PER ISPWC SD-403. 7.1. 11.25°8-IN (MJ X MJ) 7.2. 22.50°8-IN (MJ X MJ) 7.3. 45°8-IN (MJ X MJ) 8. INSTALL GATE VALVE O 8.1. ONE (1)8-IN (FL X MJ) GATE VALVE. y J ■ ■ 8.2. TWO (2) 8-IN (FL X MJ) GATE VALVES. Ut l�l ty P h a n - A r e a A 0 30' 60' 8.3. THREE (3) 8-IN (FL X MJ) GATE VALVES. 8.4. ONE (1)6-IN (FL X MJ) GATE VALVE. cc &00pC 9. INSTALL TEE WITH THRUST BLOCK PER ISPWC SD-403. N CO Horizontal Scale: 1" = 30' 9.1. ONE (1)8-IN (MJ X FL)TEE � cc `� CO 9.2. ONE (1)8-IN X 6-IN (MJ X FL)TEE cc 0C) 10. INSTALL CROSS 10.1. ONE (1)8-IN (MJ X FL) CROSS Cc Legend: Co SD STORM DRAIN Revisions 1� W WATER MAIN 1. W EXISTING WATER MAIN 811SS SANITARY SEWER MAIN AN SANITARY SEWER MANHOLE OEXISTING SANITARY SEWER MANHOLE co 0 SANITARY SEWER CLEANOUT t FIRE HYDRANT ® WATER MAIN VALVE BLOWOFF ASSEMBLY LJ GASKETED CAP SINGLE WATER SERVICE �gSZGSAL ENl DOUBLE WATER SERVICE 568 s 09/02/2025 0 �qTE OF \�P 9 ES w G 3 Project No.: 123200 Date of Issuance: 09.02.2025 Project Milestone: PERMIT a Utility Plan Area A 3 0 o E C7m01