HomeMy WebLinkAboutC6.02 Sewer Plan & Profile N. Apricot Hill Ave. Sheet Notes: = T H E 1. COMPLY WITH ALL NOTES ON SHEET C1.00. L AN D 2. ALL CONSTRUCTION AND MATERIAL SHALL BE IN ACCORDANCE WITH THE GROUP LATEST EDITION OF THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), CITY OF MERIDIAN STANDARDS,AND ADA COUNTY HIGHWAY DISTRICT STANDARDS. NO EXCEPTIONS ARE PERMITTED WITHOUT PRIOR APPROVAL. 3. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL COMPLY WITH IDAHO CODE, CHAPTER 22,TITLE 55 REGARDING UNDERGROUND FACILITIES DAMAGE ® PREVENTION. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED AS A RESULT OF FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES. THE CONTRACTOR SHALL CONTACT THE APPROPRIATE B15 L12 B15 L11 B15 L10 B15 L9 B15 L8 B15 L7 a UTILITY COMPANIES OR DIG-LINE (208.342.1585) FOR EXACT LOCATIONS A 5,128-SF 4,000-SF 4,000-SF 4,000-SF 4,000-SF 5,128-SF B10 L17 MINIMUM OF 48-HOURS PRIOR TO DIGGING. I 6,857-SF 4. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB AND GUTTER, STORM DRAIN, M N CO `° CHANNEL CROSSINGS,AND SEWER ELEVATIONS OR INVERTS PRIOR TO co � Lo N � lLo N � N Lo N � Lo N ( J CONSTRUCTION AND NOTIFY ENGINEER WHEN ELEVATIONS OR INVERTS DO NOT Q LL N Q LL N Q LL N Q LL N Q LL N O� ow O� ow O� ow O� owu 3 � owu MATCH PLANS. — — 3 5. ALL PIPE INSTALLATION AND TRENCHING SHALL CONFORM TO THE LATEST — — — — — — - — — — - - — EDITION OF THE ISPWC DIVISION 300 AND SD-301. BEDDING AND BACKFILL SHALL BE CONSTRUCTED PER SECTIONS 305 AND 306 OF THE ISPWC. 2 2 2 2 2 6. ALL SEWER SERVICE LINES SHALL HAVE A 2%MINIMUM GRADE TO THE 5 Mil8 Mile M. B10 L18 PROPERTY LINE. s,s47-SF 7. STATIONING REPRESENTS SEWER MAIN ALIGNMENT. 31+00 r 32+00 ��— 33+02.46 _ o 8 SS81 CIO SG8 S8 y w 183-LF 0 8-IN o 8. SEWER PIPE SLOPES ARE CALCULATED USING LENGTH OF RUN FROM CENTER TO PVC AT 1.37/o ° 2 N. APRICOT 2 90o a III CENTER OF MANHOLES. HILL AVE. LD SSMH 38 4.1 z Sewer Keynotes: oo - CD I 1. POTABLE WATER MAIN CROSSING-SEE CITY OF MERIDIAN SEWER NOTE NO. 2 LL LJ o ON SHEET C1.00. N cO � rO Co rO Co �O m O co + a[ o? � + a[ r � + a[ r � + ccm + � r` � M N co N co M 7r N M M Zzr N ; co N cn B10 L19 2. POTABLE/NON-POTABLE SERVICE CROSSING-SEE CITY OF MERIDIAN SEWER Q LL N Q LL N Q LL N Q LL N Q LL N LL LL LL � LL Z LL c 6,837-SF NOTE NO.3 ON SHEET C1.00. U) CD V) c' � ow � � ow � � cD v 3. INSTALL 4-IN SEWER SERVICE PER ISPWC SD-511 AND MARK PER MERIDIAN SD B16 L1 B16 L2 B16 L3 B16 L4 B16 L5 B16 L6 I�CCI SW3. 5,128-SF 4,000-SF 4,000-SF 4,000-SF 4,000-SF 5,128-SF oq a a y 4. INSTALL 48-IN STANDARD MANHOLE TYPE A PER ISPWC SD-501. 4.1. THREE-WAY SEWER MANHOLE CHANNEL. ■ 5 REMOVE EXISTING"T"-TYPE CLEANOUT AND CONNECT TO EXISTING SEWER MAIN STUB B10 L20 Cs.�s 6,827-SF Cc mmi ld Pititild�b lild�b 0 Sewer Plan & Profile - N. Apricot Hill Ave. 3 6 _ CIO Horizontal Scale: 1" = 30, 2553 2553 ■y 0 SEWER - APRICOT HILL: Sta. 30+60 - 33+90 HORIZONTAL SCALE: 1" = 30' ■� y VERTICAL SCALE: 1" = 3' � EXISTING GROUND ELEVATION 2550 AT PIPE CENTERLINE 2550 PROPOSED GRADE ELEVATION y O AT PIPE CENTERLINE 2547 2547 � � � � cc CO co_LZ boo 2544 2544 c LO 4-IN PVC PIRR CROSSING O2541 Q WATER SERVICE CROSSING 2541 Revisions OWATER SERVICE CROSSING 1. AGENCY COMMENTS- 10/24/25 I 2538 5 2538 183-1F OF 8-W PVC AT 1.37% SSMH 38 STA: 32+92.95, 0.06113 RIM: 2546.63+ 2535 DEPTH: 8.49' 2535 70-LF OF EXISTING 8-IN PVC AT 1.50% IE IN: 2538.98, 4-IN PVC (W) IE IN: 2538.98, 4-IN PVC (E) IE OUT: 2538.64, 8-IN PVC (N) r N W W CO2 cc 2532 d a EXISTING GROUND ELEVATION PROPOSED GRADE ELEVATION 2532 AT PIPE CENTERLINE AT PIPE CENTERLINE AL 2530 2530 N � � 1 � m r � � 10 coN 568 QD L0 LID LID N N N N N N N N N N � N N N N N 10/24/2025 T,9T�OF \OPT 30+60 31+20 31+80 32+40 33+00 33+60 33+90 f`9W,G Project No.: 123200 Date of Issuance: 09.02.2025 Project Milestone: PERMIT Sewer Plan & Profile N. Apricot Hill Ave. C6mO2