Loading...
HomeMy WebLinkAboutCC - Drainage Report and Calcs DRAINAGE CALCULATIONS FOR BRUNDAGE ESTATES SUBDIVISION NO. 2 ADA COUNTY, IDAHO July 22, 2025 ENGINEERING SOLUTIONS, LLP 1029 N. Rosario Street, Suite 100 Meridian, Idaho 83642 (208) 938 -0980 �\C ENS 60 OFP M. Job Number: 250522 Brundage Estates Subdivision No. 2 Drainage Calculations Report Brundage Estates Subdivision No. 2 is the second phase of a multi-phase residential development. The project is generally located in Section 25, T.3N., R.1 W., B.M., Meridian, Ada County, Idaho. It is located on the east side of Brundage Estates Sub. No. 1 and north of the Calkins Lateral and is comprised of 36 residential lots and 10 common lots on approximately 12.6+/- acres. The storm drainage from this project will be intercepted by drop inlets, will flow through sand and grease traps and then into seepage beds located within common lots. Assumptions used for this drainage report are as follows: 1. Rational Equation used to estimate storm runoff(Q = CIA) 2. SCS: TR-55 Method used to determine Time of Concentration (Tc) 3. Coefficient of Runoff used is C = 0.50 this is from ACHD Section 8011.2.1 Coefficients of Runoff. Residential Single Family 0.35-0.50. I used maximum. 4. ACHD Policy allows one half of the entire lot area to be included in the runoff calculations unless a specific lot grading plan is developed. The rational method was used to determine the peak discharge. This method uses a "C" value (0.50 in this case), Time of Concentration (Tc) calculated by SCS TR- 55 methods and rainfall Intensity Duration Frequency (IDF) curves for the Boise Front from the ACHD Storm Water Design Manual. The rainfall intensity is determined from the IDF curve where "I" is selected at the calculated Tc and the 100-year return. I used the latest ACHD spreadsheet Version 10.5, November 2018. Brundage Estates Subdivision No. 2 is divided into ten runoff collection zones. The contributing areas are depicted on the attached drainage map. Six of the drainage areas flow to existing storm drain systems constructed as a part of Brundage Estates Subdivision No. 1. The remaining four flow to two new drainage systems/seepage beds. The assumption is made that the front half is the only contributing portion of the lot. This is based on the assumption that the rear portion of the lot is self- contained and/or is delayed long after the peak discharge has passed. The peak discharge is used to determine the capacity of the pipes and drop inlet. A minimum value of 10 minutes is used to select the "I" in the peak discharge calculations. Per ACHD policy, the volume calculations are determined using Tc of 60 minutes, therefore; I=0.96". I have used the ACHD worksheets Version 10.5 dated November 2018 to determine the peak discharge, and volumes of the storms. Proposed Drainage The proposed drainage system improvements consist of drop inlets, a storm pipe network, sand and grease traps and seepage beds. Seepage Bed No. 2.1 Areas 2.1 and 2.2 will be picked up in drop inlets and piped to two 1000-gallon sand and grease traps. From the sand and grease traps an 18" pipe goes 5' into the seepage bed, then an 18" top only perforated pipe extends through the seepage bed. The bottom of the bed is in free draining soils and has 3' separation from groundwater. Seepage Bed No. 2.2 Areas 2.3 and 2.4 will be picked up in drop inlets and piped to a 1000-gallon sand and grease trap. From the sand and grease trap an 18" pipe goes 5' into the seepage bed, then an 18" top only perforated pipe extends through the seepage bed. The bottom of the bed is in free draining soils and has 3' separation from groundwater. Areas 1 and 2 flow to existing Seepage Bed 1.1, areas 3 and 4 flow to existing Seepage Bed 1.2 and Areas 5 and 6 flow to existing Seepage Bed 1.3; all constructed as a part of Brundage Estates Subdivision No. 1. Seepage Beds All seepage bed systems are sized for the 100-year storm using the ACHD spreadsheets. The seepage beds use clean drain rock wrapped in filter fabric to facilitate drainage, an 18" pipe perforated on the top only and 1.5' of sand underneath the clean drain rock. The seepage beds also contain a monitoring well inside the bed and one outside of the bed. The seepage beds were sized using a percolation rate of 1" per hour which is less than the recommended percolation rate from the soils engineer. The beds were designed to have 3' of separation from high groundwater based on the groundwater monitoring report that was provided. n N W 1 n N p a g �Q �N H Z, Hzmo � � g wp�� W W � oa aCOD W o �x Nwg 31YdI1QJ'S �,'Jj alw4GUV Z C R I E6 i�. � I � 31Y d1103tl S,' S cc $� YMwui rmt>me NaA tmurinmoe s aL (V in � I `�•. Si�53 i I I8 �- 55 i $ O i s� A A � / Of10 41 Zz TF ooc u AYM 30Q3'FlDfll'3 ;Y �O OF7 � � W N m o O r 00 N 0 N O O O V N 00 O (O O N II II II 0 I- M N (O 7 E O (n N , a7 ccV 10 N O (O 000 V V 0 N— V V N ca O O O 0 0 O O O II II II a) W U U U °N°rn 0 00 a) a) a) E E E O U U mm ul Q Q Q C9 Q N � Z co N CO � Q' * c0 N (O r— (O 0 V Q a) aJ N o w n n V (O c7 CO O a) Q U' V O Cl) V N II o O II n o N> > > V 0 0 Du 0) N V Cy 0 V 0 O O O N N —0 N O N V V 0 w N O V M r— N C1 0 0 O O O X 0 N JI O >I N N W O CD � 0 O 0 (n N N N NI N 0 O 0 N :1 2t, > ca co ca c7 V V N O N LL LL LL 0 V' V a) a) a) — 0) O) 0) C_ C_ C_ Cn U) U) O O O 0 0 0 O O O II II II U U U 00 't N 0 N _ (n i0 Lo V v v, 00) 00) 00) (D 0 0 0 0 0 E E E U N) cn U) Q Q Q O� N O O 00 O a) CDN O („> 7 0 V V O(O O LL J 0 0 0 ~ 0 r N N N Y 0 O IOI E a I I W a 00 0 a '� 00 0 00 O w Lq (q < a 0n q N� N O N Z 0 C Z O c y O N N v L a O 3 0 0 Z U) N N (� N M V toO 7 Q Z N N N N N m a) W 0 W 70 0 � c i m` m ACHD Calculation Sheet for Finding Peak Discharge/Volume-Rational Method NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology.These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.1-Area 2.1 2 Is area drainage basin map provided? YES (map must be included with stormwater calculations) 3 Enter Design Storm(100-Year or 25-Year With 100-Year Flood Route) 100 4 Enter number of storage facilities(25 max) Click to Show More Subbasins ❑ Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin 1 Subbasin 2 3 4 5 Subbasin 6 7 8 9 10 5 Area of Drainage Subbasin(SF or Acres) Acres 0.70 Acres 0.70 6 Determine the Weighted Runoff Coefficient(C) 0.50 C=[(C1xA1)+(C2xA2)+(CnxAn)]/A Weighted Avg1 0.50 7 Calculate Overland Flow Time of Concentration in Minutes(Tc)or use default 10 User Calculate min to Min. Estimated Runoff Coefficients for Various Surface Type of Surface Runoff Coefficients"i Business Downtown areas 0.70-0.95 Hydraulic Urban neighborhoods 0.50-0.70 Radius Flow Residential Intercept A/Wet Velocity V Flow Time single Family 0.35-0.50 ID Pipe Size(in) Slope(ft/ft) Coeff. Length Manning n Perm (fps) (min) Multi-family 0.60-0.75Residential(rural) 0.25-0.40 Segment 1:Pipe Flow Apartment Dwelling Areas 0.70 a Industrial and Commercial Light areas 0.80 Heavy areas 0.90 Segment 2:Gutter Shallow Concentrated Flow Parks,Cemeteries 0.1010-0.25 b 0.005 0.619 366 1.4 4.5 Playgrounds 0.20-0.35 Railroad yard areas 0.20-0.40 Segment 3:Overland Sheet Flow By TR-55,<300-ft c 0.020 40 0.240 3.6 11.1 Computed Tc= 15.6 User-Entered Tc= 15.6 8 Determine the average rainfall intensity(i)from IDF Curve based on Tc i 2.18 in r y Calculate the Post-Development peak discharge(QPeak) Qpe k 0.76 cfs 10 Calculate total runoff vol(V)(for sizing primary storage) V 1,210 ft V=Ci(Tc=60)Ax3600 it Calculate Volume of Runoff Reduction Vrr Enter Percentile Storm I(95th percentile=0.60 in) 95th 0.60 in Enter Runoff Reduction Vol(95th Percentile=0.60-in x Area x C) Vrr 756 ft' 12 Detention:Approved Discharge Rate to Surface Waters(if applicable) cfs 13 Volume Summary Unimproved areas 0.10-0.30 Surface Storage:Basin Streets Basin Forebay V 121 ft' Asphalt 0.95 Concrete 0.95 Primary Treatment/Storage Basin V 1,089 ft' Brick 0.95 Subsurface Storage Roofs 0.95 ' Gravel 0.75 Volume Without Sediment Factor(See BMP 20 Tab) V 1,210 ft Fields:Sandy soil Soil Type Slope A B C D Flat:0-2% 0.04 0.07 0.11 0. Average:2-6% 0.09 0.12 0.15 0. Steep:>6% 0.13 0.18 0.23 0. Adapted from ASCE K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Area 2.1.xlsm 7/16/2025,11:05 AM Version 10.5,November 2018 ACHD Calculation Sheet for Finding Peak Discharge/Volume-Rational Method NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology.These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. t Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Area 2.2 2 Is area drainage basin map provided? YES (map must be included with stormwater calculations) 3 Enter Design Storm(100-Year or 25-Year With 100-Year Flood Route) 100 4 Enter number of storage facilities(25 max) Click to Show More Subbasins ❑ Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin 1 Subbasin 2 3 4 5 Subbasin 6 7 8 9 10 5 Area of Drainage Subbasin(SF or Acres) Acres 3.40 Acres 3.40 6 Determine the Weighted Runoff Coefficient(C) 0.50 C=[(C1xA1)+(C2xA2)+(CnxAn)]/A Weighted Avg1 0.50 7 Calculate Overland Flow Time of Concentration in Minutes(Tc)or use default 10 User Calculate min 10 Min. Estimated Runoff Coefficients for Various Surfav Type of Surface Runoff Coefficients Business Downtown areas 0.70-0.95 Hydraulic Urban neighborhoods 0.50-0.70 Radius FlowLFlowTime Residential Intercept A/Wet Velocity V single Family 0.35-0.50 Multi-family 0.60-0.75 ID Pipe Size(in) Slope(ft/ft) Coeff. Length Manning n Perm (fps) Residential(rural) 0.25-0.40 Segment 1:Pipe Flow Apartment Dwelling Areas 0.70 a Industrial and Commercial Light areas 0.90 Heavy areas 0.90 Segment 2:Gutter Shallow Concentrated Flow Parks,Cemeteries 0.1010-0.25 b 0.006 0.619 866 1.6 9.2 Playgrounds 0.20-0.35 Railroad yard areas 0.20-0.40 Segment 3:Overland Sheet Flow By TR-55,<300-ft c 0.020 27 0.240 3.3 8.2 Computed Tc= 17.4 User-Entered Tc= 17.4 8 Determine the average rainfall intensity(i)from IDF Curve based on Tc i 2.18 in r y Calculate the Post-Development peak discharge(QPeak) Qpeak 3.71 cfs 10 Calculate total runoff vol(V)(for sizing primary storage) V 5,875 ft V=Ci(Tc=60)Ax3600 11 Calculate Volume of Runoff Reduction Vrr Enter Percentile Storm I(95th percentile=0.60 in) 95th 0.60 in Enter Runoff Reduction Vol(95th Percentile=0.60-in x Area x C) Vrr 3,672 ftJ 12 Detention:Approved Discharge Rate to Surface Waters(if applicable) cfs 13 Volume Summary Unimproved areas 0.10-0.30 Surface Storage:Basin streets Basin Forebay V 588 fe Asphalt 0.95 Concrete 0.95 Primary Treatment/Storage Basin V 5,288 ft' Brick 0.95 Subsurface Storage Roofs 0.95 Volume Without Sediment Factor(See BMP 20 Tab) V 5,875 ft' Gravel Fields:Sandy soil Soil Soil Type Slope A B C D Flat:0-2% 0.04 0.07 0.11 0. Average:2-6% 0.09 0.12 0.15 0. Steep:>6% 0.13 0.18 0.23 0. Adapted from ASCE K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Area 2.2.xlsm 7/16/2025,11:05 AM Version 10.5,November 2018 ACHD Calculation Sheet for Finding Peak Discharge/Volume-Rational Method NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology.These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. tfor Peak Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Areas 2.1 and 2.2 2 Is area drainage basin map provided? YES (map must be included with stormwater calculations) 3 Enter Design Storm(100-Year or 25-Year With 100-Year Flood Route) 100 4 Enter number of storage facilities(25 max) Click to Show More Subbasins ❑ Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin 1 Subbasin 2 3 4 5 Subbasin 6 7 8 9 10 5 Area of Drainage Subbasin(SF or Acres) Acres 0.70 3.40 Acres 4.10 6 Determine the Weighted Runoff Coefficient(C) 0.50 0.50 C=[(C1xA1)+(C2xA2)+(CnxAn)]/A Weighted Avg1 0.50 7 Calculate Overland Flow Time of Concentration in Minutes(Tc)or use default 10 Luser Calculate min 10 Min. Estimated Runoff Coefficients for Various Surfao Type of Surface Runoff Coefficients"t Business Downtown areas 0.70-0.95 Hydraulic Urban neighborhoods 0.50-0.70 Radius Flow Residential Intercept A/Wet Velocity V Flow Time Single Family 0.35-0.50 ID Pipe Size(in) Slope(ft/ft) Coeff. Length Manning n Perm (fps) (min) Multi-family 0.60-0.75 Residential(rural) 0.25-0.40 Segment 1:Pipe Flow Apartment Dwelling Areas 0.70 a Industrial and Commercial Light areas 0.80 Segment 2:Gutter Shallow Concentrated Flow Heavy areas 0. 90 Parks,Cemeteries 0.1010-0.25 b 0.006 0.619 866 1.6 9.2 Playgrounds 0.20-0.35 Railroad yard areas 0.20-0.40 Segment 3:Overland Sheet Flow By TR-55,<300-ft c 0.020 27 0.240 3.3 8.2 Computed Tc= 17.4 User-Entered Tc= 17.4 8 Determine the average rainfall intensity(i)from IDF Curve based on Tc i 2.18 in hr y Calculate the Post-Development peak discharge(QPeak) Qpeak 4.47 cfs 10 Calculate total runoff vol(V)(for sizing primary storage) V 7,085 ft V=Ci(Tc=60)Ax3600 11 Calculate Volume of Runoff Reduction Vrr Enter Percentile Storm I(9Sth percentile=0.60 in) 95th 0.60 in Enter Runoff Reduction Vol(95th Percentile=0.60-in x Area x C) Vrr 4,428 ft' 12 Detention:Approved Discharge Rate to Surface Waters(if applicable) cfs 13 Volume Summary Unimproved areas 0.10-0.30 Surface Storage:Basin Streets Basin Forebay V 708 ft Asphalt 0.95 Concrete 0.95 Primary Treatment/Storage Basin V 6,376 ft' Brick 0.95 Subsurface Storage Roofs 0.95 Volume Without Sediment Factor(See BMP 20 Tab) V 7,085 ft' Gravel 0.75 Fields:Sandy soil Soil Type Slope A B C D Flat:0-2% 0.04 0.07 0.11 0. Average:2-6% 0.09 0.12 0.15 0. Steep:>6% 0.13 0.18 0.23 0. Adapted from ASCE K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Areas 2.1 and 2.2.xIsm 7/16/2025,11:06 AM Version 10.5,November 2018 ACHD Calculation Sheet for Sand/Grease Traps NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology. These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Steps for Sand/Grease Trap Velocity Calculation User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Areas 2.1 and 2.2 2 Enter number of Sand/Grease Traps(25 max) 1 Number of Peak Flow Baffle Throat Velocity Is the S/G Traps Q-cfs Vault Size Spacing width Area(ft2) 0.5 fps Velocity inch inch max. ok? 1000 G 2 4.47 20 48 13.33 0.34 Reference for Throat widths(inch) Boise ADS Vault Lar-ken WQU, BMP 16 1000 G 48.0 50.5 n/a 1500 G 60.0 61.5 n/a WQU1000 n/a n/a 60 WQU1500 n/a n/a 60 K:\Data From PC\2025\250522- Brundage Estates No. 2\Calculations\ACHD_SD_CALCS_Areas 2.1 and 2.2.xIsm 7/16/2025, 11:06 AM Version 10.0, May 2018 ACHD Calculation Sheet for Sizing Seepage Bed With Optional Chambers NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology. These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Note this spreadsheet pulls information from the"Peak Q,V"tab Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Areas 2.1 and 2.2 2 Enter number of Seepage Beds(25 max) 1 3 Design Storm 100 4 Weighted Runoff Coefficient C 0.50 Link to: LQ,v QV TR55 5 Area A(Acres) 4.10 acres 6 Approved discharge rate(if applicable) 0.00 cfs 7 Is Seepage Bed in Common Lot? Yes V 7,085 ft3 0%Sediment 8 Set Total Design Width of All Drain Rock W 6.0 ft 9 Set Total Design Depth of All Drain Rock D 9.0 ft Rock Only,Do Not Include Filter Sand Depth or Cover 10 Void Ratio of Drain Rock Voids 0.4 0.4 for 1.5"-2"drain rock and 3/4"Chips 11 Design Infiltration Rate(8 in/hr max) Perc 1.00 in/hr 12 Size of WQ Perf Pipe(Perf 180°) Dia pipe 18 in 13 Size of Overflow Perf Pipe(Perfs 3600),READ if Q100>3.3 cfs in 14 Calculate Total Storage per Foot Spf 22.3 ft3/ft 15 Calculate Design Length L 318 320 ft Override Value Required for Chambers 16 Variable Infiltration Window L SWL 320 ft 17 Variable Infiltration Window W SWW 6.0 ft 18 Time to Drain 39.9 hours 90%volume in 48-hours minimum 19 Length of WQ&Overflow Perf Pipes 320 314 ft 20 Perf Pipe Checks.Qperf>=Qpeak; where Qperf=CdxAxd(2xgxH) Optional Storage Chambers Note:This assumes chambers are organized in a rectangular layout. 1-StormTech, 1 Type of Chambers SC740 2 Volume to Store V 0 ft3 3 Installed Chamber Width Cw 4.25 ft Installed Chamber Depth Cd 2.50 ft Installed Chamber Height Ch 7.12 ft 4 Chamber Void Factor 5 Chamber Storage Volume,Without Rock,Per Manuf 45.90 ft3/Unit 6 Chamber Storage Volume,With Rock,Per Manuf 74.90 ft'/Unit 7 Total Number of Units Required 0 ea 8 Area of Infiltration Aperc ft2 9 Volume Infiltration Vperc 0 ft3/hr 10 Time to Drain hours 90%volume in 48-hours minimum K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Areas 2.1 and 2.2.xIsm 7/16/2025,11:06 AM Version 10.0,May 2018 ACHD Calculation Sheet for Finding Peak Discharge/Volume-Rational Method NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology.These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Area 2.3 2 Is area drainage basin map provided? YES (map must be included with stormwater calculations) 3 Enter Design Storm(100-Year or 25-Year With 100-Year Flood Route) 100 4 Enter number of storage facilities(25 max) Click to Show More Subbasins ❑ Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin 1 Subbasin 2 3 4 5 Subbasin 6 7 8 9 10 5 Area of Drainage Subbasin(SF or Acres) Acres 2.10 Acres 2.10 6 Determine the Weighted Runoff Coefficient(C) 0.50 C=[(C1xA1)+(C2xA2)+(CnxAn)]/A Weighted Avgl 0.50 7 Calculate Overland Flow Time of Concentration in Minutes(Tc)or use default 10 User Calculate min 10 Min. Estimated Runoff Coefficients for Various Surface Type of Surface Runoff Coefficients"1 Business Downtown areas 0.70-0.95 Hydraulic Urban neighborhoods 0.50-0.70 Radius Flow Residential Intercept A/Wet Velocity V Flow Time single Family 0.35-0.50 ID Pipe Size(in) Slope(ft/ft) Coeff. Length Manning n Perm (fps) (min) Multi-family 0.60-0.75Residential(rural) 0.25-0.40 Segment 1:Pipe Flow Apartment Dwelling Areas 0.70 a Industrial and Commercial Light areas 0.80 Heavy areas 0.90 Segment 2:Gutter Shallow Concentrated Flow Parks,Cemeteries 0.1010 -0.25 b 0.009 0.619 1,097 1.9 9.6 Playgrounds 0.20-0.35 Railroad yard areas 0.20-0.40 Segment 3:Overland Sheet Flow By TR-55,<300-ft c 0.020 70 0.240 4.0 17.4 Computed Tc= 27.0 User-Entered Tc= 27.0 8 Determine the average rainfall intensity(i)from IDF Curve based on Tc i 1.58 in r y Calculate the Post-Development peak discharge(QPeak) Qpeak 1.66 cfs 10 Calculate total runoff vol(V)(for sizing primary storage) V 3,629 ft V=Ci(Tc=60)Ax3600 11 Calculate Volume of Runoff Reduction Vrr Enter Percentile Storm I(9Sth percentile=0.60 in) 95th 0.60 in Enter Runoff Reduction Vol(9Sth Percentile=0.60-in x Area x C) Vrr 2,268 ft' 12 Detention:Approved Discharge Rate to Surface Waters(if applicable) cfs 13 Volume Summary Unimproved areas 0.10-0.30 Surface Storage:Basin streets Basin Forebay V 363 ft Asphalt 0.95 Concrete 0.95 Primary Treatment/StorageBasin V 3,266 ft' Brick 0.95 Subsurface Storage Roofs 0.95 Volume Without Sediment Factor(See BMP 20 Tab) V 3,629 ft' Gravel 0.75 Fields:Sandy soil Soil Type Slope A B C D Flat:0-2% 0.04 0.07 0.11 0. Average:2-6% 0.09 0.12 0.15 0. Steep:>6% 0.13 0.18 0.23 0. Adapted from ASCE K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Area 2.3.xlsm 7/16/2025,11:07 AM Version 10.5,November 2018 ACHD Calculation Sheet for Finding Peak Discharge/Volume-Rational Method NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology.These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Area 2.4 2 Is area drainage basin map provided? YES (map must be included with stormwater calculations) 3 Enter Design Storm(100-Year or 25-Year With 100-Year Flood Route) 100 4 Enter number of storage facilities(25 max) Click to Show More Subbasins ❑ Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin 1 Subbasin 2 3 4 5 Subbasin 6 7 8 9 10 5 Area of Drainage Subbasin(SF or Acres) Acres 1.50 Acres 1.50 6 Determine the Weighted Runoff Coefficient(C) 0.50 C=[(C1xA1)+(C2xA2)+(CnxAn)]/A Weighted Avg1 0.50 7 Calculate Overland Flow Time of Concentration in Minutes(Tc)or use default 10 User Calculate min 10 Min. Estimated Runoff Coefficients for Various Surfao Type of Surface Runoff Coefficients Business Downtown areas 0.70-0.95 Hydraulic Urban neighborhoods 0.50-0.70 Radius Flow Residential Intercept A/Wet Velocity V Flow Time Single Family 0.35-0.50 ID Pipe Size(in) Slope(ft/ft) Coeff. Length Manning n Perm (fps) (min) Multi-family 0.60-0.75 Residential(rural) 0.25-0.40 Segment 1:Pipe Flow Apartment Dwelling Areas 0.70 a Industrial and Commercial Light areas 0.80 Segment 2:Gutter Shallow Concentrated Flow Heavy areas 0.90 Parks,Cemeteries 0.10-0.25 b 0.005 0.619 446 1.4 5.2 Playgrounds 0.20-0.35 Railroad yard areas 0.20-0.40 Segment 3:Overland Sheet Flow By TR-55,<300-ft c 0.020 75 0.240 4.0 18.4 Computed Tc= 23.6 User-Entered Tc= 23.6 8 Determine the average rainfall intensity(i)from IDF Curve based on Tc i 1.81 in r y Calculate the Post-Development peak discharge(QPeak) Qpeak 1.36 cfs 10 Calculate total runoff vol(V)(for sizing primary storage) V 2,592 ft V=Ci(Tc=60)Ax3600 it Calculate Volume of Runoff Reduction Vrr Enter Percentile Storm I(95th percentile=0.60 in) 95th 0.60 in Enter Runoff Reduction Vol(9Sth Percentile=0.60-in x Area x C) Vr, 1,620 ft' 12 Detention:Approved Discharge Rate to Surface Waters(if applicable) cfs 13 Volume Summary Unimproved areas 0.10-0.30 Surface Storage:Basin Streets Basin Forebay V 259 W Asphalt 0.95 Concrete 0.95 Primary Treatment/Storage Basin V 2,333 ft' Brick 0.95 Subsurface Storage Roofs 0.95 Volume Without Sediment Factor(See BMP 20 Tab) V 2,592 ft Gravel 0.75 Fields:Sandy soil Soil Type Slope A B C D Flat:0-2% 0.04 0.07 0.11 0. Average:2-6% 0.09 0.12 0.15 0. Steep:>6% 0.13 0.18 0.23 0. Adapted from ASCE K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Area 2.4.xlsm 7/16/2025,11:07 AM Version 10.5,November 2018 ACHD Calculation Sheet for Finding Peak Discharge/Volume-Rational Method NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology.These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Areas 2.3 and 2.4 2 Is area drainage basin map provided? YES (map must be included with stormwater calculations) 3 Enter Design Storm(100-Year or 25-Year With 100-Year Flood Route) 100 4 Enter number of storage facilities(25 max) Click to Show More Subbasins ❑ Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin Subbasin 1 Subbasin 2 3 4 5 Subbasin 6 7 8 9 10 5 Area of Drainage Subbasin(SF or Acres) Acres 2.10 1.50 Acres 3.60 6 Determine the Weighted Runoff Coefficient(C) 0.50 0.50 C=[(C1xA1)+(C2xA2)+(CnxAn)]/A Weighted Avgl 0.50 7 Calculate Overland Flow Time of Concentration in Minutes(Tc)or use default 10 User Calculate min 10 Min. Estimated Runoff Coefficients for Various Surface Type of Surface Runoff Coefficients"I Business Downtown areas 0.70-0.95 Hydraulic Urban neighborhoods 0.50-0.70 Radius FlowLFlowTime Residential Intercept A/Wet Velocity V single Family 0.35-0.50 Multi-family 0.60-0.75 ID Pipe Size(in) Slope(ft/ft) Coeff. Length Manning n Perm (fps) Residential(rural) 0.25-0.40 Segment 1:Pipe Flow Apartment Dwelling Areas 0.70 a Industrial and Commercial Light areas 0.80 Heavy areas 0.90 Segment 2:Gutter Shallow Concentrated Flow Parks,Cemeteries 0,10-0.25 b 0.009 0.619 1,097 1.9 9.6 Playgrounds 0.20-0.35 Railroad yard areas 0.20-0.40 Segment 3:Overland Sheet Flow By TR-55,<300-ft c 0.020 70 0.240 4.0 17.4 Computed Tc= 27.0 User-Entered Tc= 27.0 8 Determine the average rainfall intensity(i)from IDF Curve based on Tc i 1.58 in r y Calculate the Post-Development peak discharge(QPeak) Qpeak 2.84 cfs 10 Calculate total runoff vol(V)(for sizing primary storage) V 6,221 ft V=Ci(Tc=60)Ax3600 11 Calculate Volume of Runoff Reduction Vrr Enter Percentile Storm I(95th percentile=0.60 in) 95th 0.60 in Enter Runoff Reduction Vol(95th Percentile=0.60-in x Area x C) Vrr 3,888 ft, 12 Detention:Approved Discharge Rate to Surface Waters(if applicable) cfs 13 Volume Summary Unimproved areas 0.10-0.30 Surface Storage:Basin streets Basin Forebay V 622 ft Asphalt 0.95 Concrete 0.95 Primary Treatment/Storage Basin V 5,599 ft' Brick 0.95 Subsurface Storage Roofs 0.95 Volume Without Sediment Factor(See BMP 20 Tab) V 6,221 ft' Gravel 0.75 Fields:Sandy soil Soil Type Slope A B C D Flat:0-2% 0.04 0.07 0.11 0. Average:2-6% 0.09 0.12 0.15 0. Steep:>6% 0.13 0.18 0.23 0. Adapted from ASCE K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Areas 2.3 and 2.4.xlsm 7/16/2025,11:08 AM Version 10.5,November 2018 ACHD Calculation Sheet for Sand/Grease Traps NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology. These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Steps for Sand/Grease Trap Velocity Calculation User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Areas 2.3 and 2.4 2 Enter number of Sand/Grease Traps(25 max) 1 Number of Peak Flow Baffle Throat Velocity Is the [71000G Spacing width Area(ft2) 0.5 fps Velocity S/G Traps Q-cfs inch inch max. ok? 1 2.84 20 48 6.67 0.43 Reference for Throat widths(inch) ADS Boise Lar-ken WQU, Vault BMP 16 1000 G 48.0 50.5 n/a 1500 G 60.0 61.5 n/a WQU1000 n/a n/a 60 WQU1500 n/a n/a 60 K:\Data From PC\2025\250522- Brundage Estates No. 2\Calculations\ACHD_SD_CALCS_Areas 2.3 and 2.4.xlsm 7/16/2025, 11:08 AM Version 10.0, May 2018 ACHD Calculation Sheet for Sizing Seepage Bed With Optional Chambers NOTE:This worksheet is intended to be a guideline to standardize ACHD checking of drainage calculations and shall not replace the Engineer's calculation methodology. These calculations shall establish a minimum requirement.The Engineer's methodology must result in facilities that meet or exceed these calculations in order to be accepted. Note this spreadsheet pulls information from the"Peak QV"tab Calculate Post-Development Flows(for pre-development flows,increase number of storage facilities to create new tab) User input in yellow cells. 1 Project Name Brundage Estates Subdivision No.2-Areas 2.3 and 2.4 2 Enter number of Seepage Beds(25 max) 1 3 Design Storm 100 4 Weighted Runoff Coefficient C 0.50 Link to: LQY QV TR55 5 Area A(Acres) 3.60 acres 6 Approved discharge rate(if applicable) 0.00 cfs 7 Is Seepage Bed in Common Lot? No V 7,776 ft3 25%Sediment 8 Set Total Design Width of All Drain Rock W 15.0 ft 9 Set Total Design Depth of All Drain Rock D 9.0 ft Rock Only,Do Not Include Filter Sand Depth or Cover 10 Void Ratio of Drain Rock Voids 0.4 0.4 for 1.5"-2"drain rock and 3/4"Chips 11 Design Infiltration Rate(8 in/hr max) Perc 1.00 in/hr 12 Size of WQ Perf Pipe(Pert 180°) Dia pipe 18 in 13 Size of Overflow Perf Pipe(Perfs 360%READ if Q100>3.3 cfs in 14 Calculate Total Storage per Foot Spf 55.4 ft3/ft 15 Calculate Design Length L 140 ft Override Value Required for Chambers 16 Variable Infiltration Window L SWL 140 ft 17 Variable Infiltration Window W SWW 15.0 ft 18 Time to Drain 39.9 hours 90%volume in 48-hours minimum 19 Length of WQ&Overflow Perf Pipes 140 134 ft 20 Perf Pipe Checks.Qperf>=Qpeak; where Qperf=CdxAxV(2xgxH) Optional Storage Chambers Note:This assumes chambers are organized in a rectangular layout. 1-StormTech, 1 Type of Chambers SC740 2 Volume to Store V 0 ft 3 3 Installed Chamber Width Cw 4.25 ft Installed Chamber Depth Cd 2.50 ft Installed Chamber Height Ch 7.12 ft 4 Chamber Void Factor 5 Chamber Storage Volume,Without Rock,Per Manuf 45.90 ft3/Unit 6 Chamber Storage Volume,With Rock,Per Manuf 74.90 ft'/Unit 7 Total Number of Units Required 0 ea 8 Area of Infiltration Aperc ft2 9 Volume Infiltration Vperc 0 ft3/hr 10 Time to Drain hours 90%volume in 48-hours minimum K:\Data From PC\2025\250522-Brundage Estates No.2\Calculations\ACHD_SD_CALCS_Areas 2.3 and 2.4.xlsm 7/16/2025,11:08 AM Version 10.0,May 2018 v LO W d' ti 00 F— N V LO = Ch OD O O LO LO O CL OQ O O N ti I— N O O O O 9 V N N N N O O O O O O O O O N Ld? Lq Ld) Lq Lf-) Lf) Lf) Lf) Lf) 'a N 0 0 0 0 0 0 CO CO 0 E E E E C ' 00 CO 00 00 00 00 00 00 co x x x x O O O O O O O O O O O O O O CV N (N N N N N N N Q Q Q 0 V V V V V V V V V m m m m 4- 4- 4- 4- ca c� ca c� U) Ln U) U) N cY 0 LO LO LO LO LO LO LO Lid J � � O N N N N N N N N S L •; N N N N N N N N N c c c c O V V V V V V V V V O O O 0 Q 0 C 7 — 7 G N Z3 D Z; Z3 NLO 0 0 0 0 L O N > +� Z a N N O .CD m ++ � � > > > > O O O O Z � W �_ .O i O 'a (1) L. L() O L() LO N LO r` r-- C,6 C,6 (Q _ M N O c� _ MLO Q Q �V11 M 0 U U U U �O �O Lil 0 n 4- � � � N N 3 _Q Q Q _Q ,Q _Q Q Q O Q Q Q Q O) U) O O O O CD CD CD CD - O O Q CV Ln L? Ln LO LO LO LO L- L- L- � O O m CL Ln LO LO Ln LO U-) Ln U-) LO cn cn w cn E E n n n n n n n n n Z3 Z3 � o 0 O O O O 0 o 0 O O O O0 LO LO Lo LO LO LO LO LO c� O I` ti r` ti a' f` Cfl Cfl CO Cfl CU Cfl C� Cfl ti LO LO N m N ~ n n n n n n n n n 7- = = 0 0 4- a� a� N w O O Q Q CL 0- Q 0 0- 0- 0- x x LO N N N Lo Lo Lo Lo Lo LO N c� � N N N CD O O N N N N N N 0- 0- 0 - 0) O N N N 0 0 0 0 0 O Q) N N -- N N N N N N ,� 0 LO N N N � LO LO m Iq O O O O O O O N -- -- N N N N N O N O O O N CY) O c- N N (Y') LoLO cn cn cn cn m m m m 0 C) N co V Ln CO Test Pit Log Project: Brundage Estates Subdivision Page 1 of 1 Client: Lee Centers Project No.: 24006 Test Pit: TP-3 Excavation Company: Schmidt Construction Excavation Date: 5/30/2025 Excavation Equipment: DEERE 350D Logged By: A. Mascorro Excavator Bucket Width: 5 feet Test Pit Location (Latitude, Longitude): Equipment Operator: David 43.5683020, -116.4095610 Laboratory Tests _71Q Notes / Remarks USCS Soil Description Atterber g M Limits Depth to Groundwater: N/A Y U) Ground Elevation =2706.3 ft N I 2E LL PL PI BGS = Below Ground Surface 0 Fat CLAY with Sand (Native): brown, very Approximately 6 inches of 1 U stiff to stiff, moist surficial topsoil and roots. Sandy silt contained cemented 2 _J Sandy SILT: orange-tan, m. dense to dense, moist �% -�r���. particles 3fy x SILT-STONE (hardpan): tan, hard to very'hard dA 4 Silty SAND with 1/" to 8" diameter cemented particles (caliche): orange-tan, dense, moist 5 W 6 [1, 7 x SILT-STONE (hardpan): orange-tan, very hard ro r�l S 8 Silty SAND with 1/2" to 8" diameter cemented 9 particles (caliche): orange-tan, dense to medium dense, moist 10 11 12 ...... Variable weakly cemented zones W observed from 10 to 15 feet 13 14 15 Field seepage test 16 performed at 17 feet. Seepage rate 3 in/hr. 17 Test pit terminated at 17 feet BGS. 18 PVC pipe installed to 17 feet BGS. 19 Test Pit Log Project: Brundage Estates Subdivision Page 1 of 1 Client: Lee Centers Project No.: 24006 Test Pit: TP-4 Excavation Company: Schmidt Construction Excavation Date: 5/30/2025 Excavation Equipment: DEERE 350D Logged By: A. Mascorro Excavator Bucket Width: 5 feet Test Pit Location (Latitude, Longitude): Equipment Operator: David 43.5683080, -116.4079560 Laboratory Tests Notes / Remarks $ U' USCS Soil Description � `. Atterberg � U � ..c Limits Depth to Groundwater: N/A Ground Elevation =2706.7 ft o 2 LL PL PI JBGS = Below Ground Surface 0 Fat CLAY with Sand (Native): brown, very Approximately 6 inches of = stiff to stiff, moist surficial topsoil and roots. 1 U 2 -7 0 Sandy silt contained cemented J Sandy SILT: orange-tan, m. dense tp dense moist particles 3 SILT-STONE (hardpan): tan, hard to very x hard 4 Q� Silty SAND with 1/� to 8 diameter cemented 6 particles (caliche): orange-tan, dense, moist 7 � s x SILT-STONE (hardpan): orange-tan, very 9 L hard 10 Silty SAND with 1/2" to 8" diameter cemented particles (caliche): orange-tan, dense, moist 11 U) 12 SILT-STONE (hardpan): orange-tan, very 13 x hard 14 Silty SAND with 1/2" to 8" diameter cemented 15 particles (caliche): orange-tan, dense to medium dense, moist 16 2 U) 17 Field seepage test performed at 18.25 feet. 18 * sy Seepage rate 4 in/hr. Test pit terminated at 18.25 feet BGS. 19 PVC pipe installed to 18.25 feet BGS. 20