HomeMy WebLinkAboutEstancia Subdivision No. 2 FP-07-005
BEFORE THE MERIDIAN CITY COUNCIL
C/C March 20, 2007
IN THE MATTER OF THE )
APPLICATION OF ESTANCIA )
DEVELOPMENT, INe., FOR FINAL )
PLAT APPROVAL OF 62 SINGLE- )
FAMILY RESIDENTIAL BUILDING )
LOTS AND 8 COMMON LOTS ON )
20.18 ACRES IN AN R-8 ZONE )
LOCATED WEST OF EAGLE )
ROAD ON AMITY ROAD IN THE )
WEST ~ OF THE SE Y-I OF THE SW )
Y-I OF T. 3N., R. IE., SECTION 29 )
)
)
CASE NO. FP-07-00S
ORDER OF CONDITIONAL
APPROVAL OF FINAL PLAT
This matter coming before the City Council for Final Plat approval pursuant to
Unified Development Code 11-6B-3 on March 20, 2007, and the Council finding that the
Administrative Review is complete from Kristy Vigil, Assistant City Planner for the Planning
Department, and Michael Cole, Development Services Coordinator for the Public Works
Dqmrum:nt, dated: Hearing Date: March 20, 2007, to the Mayor and Council, and the Council
having considered the requirements ofthe preliminary plat the Council takes the following action:
IT IS HEREBY ORDERED THAT:
1. The Final Plat of "PLAT SHOWING ESTANCIA SUBDIVISION NO. 2 LOCATED
IN THE WEST ~ OF THE SE ~ OF THE SW ~ OF T. 3N., R., IE., SECTION 29,
BOISE MERIDIAN, MERIDIAN, ADA COUNTY, IDAHO 2007,
ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT
FOR ESTANCIA SUBDIVISION NO.2 / (FP-07-005)
Page 101"4
HANDWRITTEN DATE: 01/31/07, SHEET I OF 5, BAILEY ENGINEERING,
INC.", ESTANCIA DEVELOPMENT, INC., Developer, is Conditionally Approved
subject to those conditions of Staff comments as set forth in the Memorandum to the
Mayor and City Council from Kristy Vigil, Assistant City Planner for the Planning
and Zoning Department and Michael Cole, Development Services Coordinator for
the Public Works Department, dated: Hearing Date: March 20, 2007, listing 17 SITE
SPECIFIC REQUIREMENTS/FINAL PLAT and II GENERAL REQUIREMENTS,
a true and correct copy of which is attached hereto marked Exhibit "A", and
consisting of 4 pages, and by this reference incorporated herein, and the response
letter from Bailey Engineering, Inc., a true and correct copy of which is attached
hereto marked Exhibit "B" and consisting of 1 page, and by this reference
incorporated herein, and the response letter from Intermountain Gas Company, a true
and correct copy of which is attached hereto marked Exhibit "c" and consisting of I
page, and by this reference incorporated herein, and the additional requirements of
the Council taken at their March 20,2007 meeting as follows, to-wit:
1.1 Adopt the Recommendation of the Central District Health
Department as follows:
The Central District Health requires after written approval
from the appropriate entities are submitted, they can approve
this proposal for central sewage and central water; that plans
must be submitted to and approved by the Idaho Department
of Health and Welfare, Division of Environmental Quality for
central sewage and central water; that run-off is not to create a
mosquito breeding problem; and it is suggested that the
stonnwater be pretreated through a grassy swale prior to
ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT
FOR ESTANCIA SUBDIVISION NO.2 / (FP-07-005)
Page 2 of 4
discharge to the subsurface to prevent impact to groundwater
and surface water quality; that engineers and architects should
obtain current best management practices for stormwater
disposal and design a stormwater management system that is
preventing groundwater and surface water degradation.
Manuals for guidance:
1. State of Idaho Catalog of Stormwater Best
Management Practices for Idaho Cities and Counties.
Prepared by the Idaho Division of Environmental
Quality, July 1997.
2. Stormwater Best Management Practices Guidebook.
Prepared by City of Boise Public Works Department,
May 2000.
2. The final plat upon which there is contained the Certification and signature of the
City Clerk and the City Engineer verifYing that the plat meets the City's requirements shall
be signed only at such time as:
1. The Plat dimensions are approved by the City Engineer; and
2. The City Engineer has verified that all off-site improvements are completed
and/or the appropriate letter of credit or cash has been issued guaranteeing the
completion of off-site and required on-site improvements.
NOTICE OF FINAL ACTION
AND RIGHT TO REGULATORY TAKINGS ANALYSIS
The Applicant is hereby notified that pursuant to Idaho Code 67-8003, the Owner may
request a regulatory taking analysis. Such request must be in writing, and must be filed with the City
Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A
rt:4. ut:st fur a rt:gulatury takings analysis will tull tht: timt: period within which a Petition for Judicial
Review may be filed.
ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT
FOR ESTANCIA SUBDIVISION NO.2 / (FP-07-005)
Page 3 of 4
Please take notice that this is a final action of the governing body of the City of
Meridian, pursuant to Idaho Code ~ 67-6521. An affected person being a person who has an interest
in real property which may be adversely affected by this decision may, within twenty-eight (28) days
after the date of this decision and order, seek a judicial review as provided by Chapter 52, Title 67,
Idaho Code.
By action of the City Council at its regular meeting held on the dO th day
of ---.O:Ja yt1h
,2007.
Copy served upon:
,',"''''''''''''~;, ~:~
"",~"", ~ ~'~/I~ YOR T de WEERD
~ ......,~ r..t1: //
~v 1:'~;-
~ ~()-::
~ ~
~ -
- -
- ::'
BElJ..L
"1
~s _
-'1\ P ~~
~ (") _ 7 13' ' x,::>
~ .., (') '" -:
""" C'..-... h. ...J ~,. , ",\
/111 .~T"\ , .,.,"
I't, .' I.',.. '
""'"1111\; ,
./ Applicant
../ Planning Department
/. Public Works Department
J City Attorney
ATTEST:
BYlJ... ~
Ity Clerk's Office
Dated: ~ -t q -ol
ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT
FOR ESTANCIA SUBDIVISION NO.2 / (FP-07-005)
Page 4 of 4
CITY OF MERIDIAN PLANNING AND PUBLIC WORKS
STAFF REPORT:
Hearing Date: March 20,2007
Transmittal Date: March 15, 2007
DEPARTMENTS STAFF REPORT
~;;di~ \
.\ lIMHO
TO:
Mayor and City Council
Kristy Vigil, Assistant City Planner 'FJ/
208-884-5533
Michael Cole, Development Services Coordinator rv\ C
208-898-5500
FROM:
sunmCT:
Estancia Subdivision No.2
Request for Final Plat Approval of Estancia Subdivision No. 2 Consisting of 62
Single-Family Residential Building Lots and 8 Common Area Lots on 20.18
Acres in an R-4 Zone by Estancia Development, LLC (File# FP-07-005).
We have reviewed this submittal and offer the following comments and conditions of the applicant.
These conditions shall be considered in full, unless expressly modified or deleted by motion of the
Meridian City Council:
APPLICATION SUMMARY & LOCATION
The applicant, Estancia Development, LLC, has applied for final plat approval of 62 single-family
residential building lots and 8 common area lots on 20.18 acres of land for Estancia Subdivision NO.2.
The zoning district for the proposed subdivision is R-8 (Medium-Density Residential). The gross density
ofthe proposed subdivision is 3.1 dwelling units per acre; the net density is 4.2 dwelling units per acre.
Estancia Subdivision No.2 is located on the north side of Amity Road, approximately a ~ mile east of
Locust Grove Road in the SW y.; of T. 3N., R. IE., Section 29. This property has not been previously
platted.
This second phase of Estancia Subdivision was originally preliminary platted as Cottswold Village
Subdivision. The City Council approved the preliminary plat for Cottswold Village Subdivision on
November 28,2006. The submitted final plat substantially complies with the approved preliminary plat.
Staff recommends approval of Estancia Subdivision No.2 with the comments and conditions stated
in this report.
SITE SPECIFIC CONDITIONS
1. Applicant is to meet all terms of the approved annexation (AZ-06-042) and preliminary plat (PP-
06-044).
2. The Final Plat approval for this subject phase shall expire on 12/12/08.
3. Sanitary sewer and water service to this site is being proposed via extensions of existing mains
installed in previous phases. Applicant will be responsible to construct the sewer and water mains
to and through this proposed development. Subdivision designer to coordinate main sizing and
routing with the Public Works Department. Applicant shall execute City of Meridian standard
forms of easements, for any mains that are required to provide service.
Exhibit "A"
FP-07-005 Estancia Subdivision No.2 FP.doc
PAGE 1
CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT
4. The City Engineer shall not sign the plat for this development prior to the Black Cat Trunk
connecting to the Glacier Springs Diversion Manhole, or the applicant shall be required to install
an "Off Peak Pumping Station" in a location coordinated with the Public Works Department. The
design shall be coordinated with the Public Works Department.
5. Revise the construction plans and plat to include the 15-inch sewer main being proposed from
Bellingham Park to be included in a common lot, instcad of within a buildable lot. All lots must
still meet them minimum dimensional standards as required by code.
6. The applicant shall be required to install the sewer to and through this subdivision. This means
an 8-inch line to the western boundary in Amity Road, and the IS-inch line to the eastern
boundary in Amity Road.
7. Prior to any excavation or improvements within this development that applicant shall submit a
Flood Plain Development Pennit and comply with all conditions of the same.
8. The applicant has indicated that Nampa and Meridian Irrigation District will own and operate the
required pressurized irrigation system in this development. Therefore a letter of plan approval
shall be submitted prior to scheduling of a preconstmction meeting_
9. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water. If a single-point connection is used, the developer shall be responsible for the
payment of assessments for the irrigable common areas prior to signature on the final plat by the
Meridian City Engineer_
10. The applicant shall dedicate additional Public Utilities, Drainage and Irrigation Easement along
interior lot lines where the pressurized irrigation system is being installed. The width needs to be
sufficient to ensure 5-feet past the centerline of pipe.
11. Graphically depict a special setback from the right.of-way on the lots listed below. The setback
needs to be sufficient to ensure the 20-foot separation between an infiltration trench and a
building foundation as required by The Department of Envirorunental Qualities Best Management
Practices:
a) The eastern boundary of Lots 11-15 Block 5.
b) The north boundary of Lots 1-2, Block 14.
12. Revise or add the following note(s) on the face of the plat prepared by Bailey Engineering, Inc.,
stamped on 01/31/07 by D. Terry Peugh, prior to signature ofthe final plat by the City Engineer:
8.) Revise to read, ". . . shall be restrictea to [ooc foot open fence per City of Meridian
requirefReBts in compliance with the applicable zoning regulations of the City of
Meridian at the time uf submittal".
10.) Delete note.
12.) Revise note to accurately reflect where sewer easement will be placed per site specific
condition #5 above.
13. All fencing installed on the site must be in compliance with UDC 11-3A-6 and 11-3A-7, and as
proposed on the landscape plan as amended with condition #14 below. Temporary construction
fencing to contain debris shall be installed at the subdivision boundary where permanent fencing
Exhibit "A"
FP~07-005 Estancia Subdivision NO.2 FP.doc
PAGE 2
CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT
does not exist. Perimeter fencing shall be installed prior to release of building pennits for this
subdivision.
14. The landscape plan, prepared by Jensen Belts and dated 02/07/07, shall be revised as follows:
a. Include the details of the gazebo on the face of the plan;
b. Label the fencing adjacent to Lots 2 - 5, Block 15.
c. The 6.foot solid fencing adjacent to Lot 9, Block 13 shall be revised per UDC 11-3A-
7A7b.
Submit three copies qf the revised landscape plan to the Planning Department prior to signature
of the final plat by the City Engineer.
15. Submit a copy of the Ada County Street Name Committee's "Final" letter for the street names
and lot & block numbering. Make all corrections necessary to comply.
16. All areas approved as open space shall be free of wet ponds or other such nuisances. All
stonnwater detention facilities llll,;urporated into the approved open space are subject to UDC 11-
3B.ll and shall be fully vegetated with grass and trees. Sand, gravel or other non-vegetated
surface materials shall not be used in open space lots, except as permitted under 1 me; 11- 3B-ll.
If the stormwater detention facility cannot be incorporated into the approved open space and still
meet the standards of UDC 11-3B.11, then the applicant shall relocate the facility. This may
require losing a developable lot or developable area. It is the responsibility of the
developer to comply with ACHD, City of Meridian and all other regulatory requirements at the
time of final construction.
17. Staff s failure to cite specific ordinance provisions or conditions from the preliminary plat does
not relieve the Applicant of responsibility tor compliance.
GENERAL REQUIREMENTS
1. Per UDC 11-3A.6 all irrigation ditches, laterals or canals, exclusive of natural waterways, that
intersect, cross or lie within the area being subdivided shall be covered. Plans will need to be
approved by the appropriate irrigation/drainage district, or lateral users association (ditch
owners), with written approval or nun-approval submitted to the Public Works Department prior
to plan approval. If lateral users association approval can not be obtained, alternate plans will be
reviewed and approved by the City Engineer.
2. Street signs are to be in place, water system shall be approved and activated, fencing installed,
drainage lots constructed, road base shall be approved by the Ada County Highway District, and
the Final Plat for this subdivision shall be recorded, prior to applying for building pennits.
3. A letter of credit or cash surety in the amount of 110% shall be required for all uncompleted
fencing, landscaping, amenities, pressurized irrigation, sanitary sewer, water, etc., prior to
signature on the final plat.
4. All development improvements, including but not limited to water, sewer, fencing, micro-paths,
pressurized irrigation and landscaping shall be installed and approved prior to obtaining
certificates of occupancy.
5. A written certificate of completion shall be prepared by the landscape architect, landscape
designer or qualified nurseryman responsible for the landscape plan upon completion of the
landscape installation. The Certificate of Completion shall verify that all landscape
Exhibit "A"
FP-07-005 Estancia Subdivision No.2 FP.doc
PAGE 3
CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEP AR TMENTS STAFF REPORT
improvements, including plant materials and sprinkler installation, are in substantial compliance
with the approved landscape plan.
6. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as detennined during the plan review process, prior to signature on the final plat.
7. Compaction test results must be submitted to the Meridian Building Department for all building
pads receiving engineered backfill, where footing would sit atop fill material.
8. Applicant shall be responsible for application and compliance with any Section 404 Pennitting
that may be required by the Army Corps of Engineers.
9. Applicant shall be responsible for application and compliaw:t: with and NPDES Permitting that
may be required by the Environmental Protection Agency.
10. All development features shall comply with the Americans with Disabilities Act and the Fair
Housing Act.
11. Any tree over 4" in caliper that is removed from the property shall be replaced by installing
additional trees. being the equivalent number of caliper inches of trees that were removed.
Required landscaping trees will not be considered as replacement trees for those trees that have to
be removed.
STAFF RECOMMENDATION
Staff recommends approval of the final plat for Estancia Subdivision No.2 (FP-07-005) with the
above stated comments and conditions.
Exhibit "A"
FP-07-005 Estancia Subdivision NO.2 FP.doc
PAGE 4
u--.-.
~iley Engineering,lnc.
CIVIL ENGINEERINGIPLANNINGICADD
DATE:
l'Vlnr('h HI, 2007
TO:
Mayor and City Council
RE:
Estancia Subdivision No.2
Dear Mayor and City Coullcil,
On bebalf of our client we would like to state that Estancia Development, LLC. agrees with all Site
Specific Comments and Conditions set forth in the final plat for Estancia Subdivision NO.2
Thank YOll for your time and consideration,
Sincerely,
c/t/~
Aj Lopez
1500 E. Iron Eagle Drive ~ Eagle, Idaho 83616 . Tel.. 208-938-0013 . Fax: 208-938-0516
www.baileyengineers.colll
Exhibit "8"
~'\
~-'.,,' "'.
" .
L-.. \.
'.--' \
(~\
\ }
~......_--- - .,~.....,
"
1,1AR - 1 2GG?
WESTERN REGION OFFICE
INTERMOUNTAIN GAS COMPANY
: ). !!) t ,:",\. .1' i:"'~: J
'. j
555 SOUTH COLE ROAD · PO BOX 7608 . BOISE, ID 83707
(208) 377-6000 . FAX (208) 377-6867
FEB 2 8 2007
(b.; ~Po1-005
~aI~ )18. ~
To Planning and Zoning,
Intennountain Gas Company has received your letter of application. In order to best serve
this development Intennountain Gas does require that a 5' minimum utility easement along
the interior lot lines and a 10' minimum utility easement along all right of ways or private
drive. The private drive of the development would also be required to include a utility
easement for Intermountain Gas to encroach into with the gas lines.
Thank you for your time and consideration in this matter. If you have any questions or
concerns please contact Mishelle Singleton at 377-6863.
Sincerely,
m~ ~9A---
Mishelle Singleton
Engineering Tech
cc: Roger Phillips
Exhibit "C"