HomeMy WebLinkAboutC5.03_Water Plan Water Plan \ /�.�
0
%= T H E
L AN D
- G R O U P
EP EP \ 131 L34
11
6„pIRR
EP EP 6 pIRR \
EP � B1 L33
EP Ep VP
— 6 pIRR \ INSTALL 12"x12"x8"TEE I INSTALL 8"22.5°ELBOW
EP 1-12"GATE VALVE W/THRUST BLOCK \
6„pIRR M M I \ 1-8"GATE VALVE PER ISPWC SD-403
131 L32 W/THRUST BLOCK PER ISPWC SD-403
---------------- I INSTALL 8"22.50 ELBOW 131 L35
INSTALL 8 L.F. 6"WATER MAIN — — — _— W/THRUST BLOCK
I 131 L31 1-6" FIRE HYDRANT PER CITY OF PE ISPWC SD-403 F.o
MERIDIAN W8 \
131 L30 \ W/THRUST BLOCK PER ISPWC SD-403 ' r \ 30-LF 8-IN C900
�I B 9 \ W2 -== -==W2 - W2 INSTALL 8" 11.25°ELBOW F,o
B1 L28 INSTALL 8 TEE �2-8"GATE VALVE — \N CgpO W/THRUST BLOCK
37-LF 8-IN C900 PER ISPWC BLOCK
\ F,o
I B1 L27 INSTALL 8 L.F. 6"WATER MAIN W/THRUST BLOCK PER ISPWC SD-403 —— — ,, Al-�F$' 0lF \ / 6�
1-6"FIRE HYDRANT PER CITY OF `114i
MERIDIAN W8 — — — — — p0 Cg4p \
I W/THRUST BLOCK PER ISPWC SO-403 — — — —— _ — — — 16�F$\N�g O 8 SS \ \ \\ B1 L36 F,o
REMOVE EXISTING BLOW-OFF _ _— — — _ _ _- W2 W1 \\ F,� t�►
AND CONNECT TO EXISTING 8" MAIN F%
_ _ _ — — — _------ ' \ i \
8-IN C900 W2 \ `AZL\` /
203- o,
_- -- op
W2 _ O \ -LF 4-IN pI R \ W2
MiP
=65-LF 8-IN C900 W3 d W1 _ n $t _ __---- 71 r R \
IN _ W ening
__------ a-7 T 8- 900 r \
LU
W2 4 p1RR W3 \ \\ \\ \ ` \ <%
W1 C4
W2 _ � 8„SS � % �—�— � � `� `� \ \ ��� �� \ B1 L37 \ F,o
8 SS W3 W1 F,
61
CP
CD
IN PI \ W2 \ \ \ 'T \
— 67 L15
CL
B7L13 dd � � \ � � \\ \\ \� � o� \\ O
\
B1 L38 C2
W \ \ o ? W2 \ s \ \ \ O \ CD
W CA \ o W2
\o ?y
CA
cs \ \ Oc \ / F,o
\ /� - dd v � v v 3 ,� v v so �, ��
F
,� LU 0
CD
B7 L16 V A \ �P, ��
\ \ \ \ W1 \ \ / / <% \
W CA CA \ \ y \ B7 L12 \ v \ \ \
\ C
\ \ \ \ \ \ o W2 lc \CP 131 L39
s i B4 L16 V '� \ \ �� \ \V ��� 2��� A A O
1A2 `� �� A Q
B7 L17W2 W2 M
s \ V B7 L11 d �� \ ` V / w
v s CA C3
d� B4 L17 \ \ \ '
W2 \\ \ cn \\ \\ \ \ 131 L40
W2 \ B8 L2 \ ` s� \\ Revisions
\ \ / \ \
\ \ ` INSTALL 8"22.50 ELBOW 1. AGENCY COMMENTS 07-28-25
B7 L18 \ �� \ low so / `� ` W/THRUST BLOCK
� \ ERAS WC SD-403
goo
s B4 L18 \\ o \ B7 L10 --sheet C5.02Soo
\
W2wassumum \\ W2 `PcP U \
d o \ /
\ \ \ W2
/ \ 00
Se Sheet C5.02 \ \ d \ Wi J /
� A \
B8 L3 \
67 L19 \
\ B4 L19 \ \ \ W2
/ \\ Water Plan 0 30' 60'
Horizontal Scale: 1" = 30'
��SZONAL ENS
G\ST 1�
Keynotes: Sheet Notes: Legend:
10961
1. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROPRIATE
W1 POTABLE WATER MAIN CROSSING-SEE WATER NOTE N0. 2 ON THIS SHEET. sV 8"WATER MAIN (OR AS NOTED) sV EXISTING WATER MAIN
LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL .1 OF 0
W2 POTABLE/NON-POTABLE WATER SERVICE CROSSING-SEE WATER NOTE NO. 3 ON EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY 2" BLOW-OFF ASSEMBLY PER CITY OF MERIDIAN DETAIL W13 O® EXISTING BLOW-OFF ASSEMBLY J�soN DEN
THIS SHEET. RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY HIS FAILURE TO
8"or 12" C900 CONDUIT FOR PRESSURE IRRIGATION, PLACE REBAR AT BOTH ENDS EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. • GATE VALVE ® EXISTING GATE VALVE 0712512025
W3 FOR LOCATING PURPOSES. SEE PRESSURE IRRIGATION PLANS FOR LENGTHS. Project No.: 121172
2. MIDSECTION LINE WATER MAINS SHALL HAVE 5 FEET OF COVER, IN ALL OTHER AREAS FIRE HYDRANT PER CITY OF MERIDIAN DETAIL W8 EXISTING FIRE HYDRANT
e COVER SHALL BE 4 FEET. Date of Issuance: 07-28-2025
PROTECT IN PLACE ALL EXISTING UNDERGROUND UTILITIES AND SURFACE Project Milestone: PERMIT SUBMITTAL
W4 APPURTENANCES. LOCATE ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. CALL 3/4"WATER SERVICE PER CITY OF MERIDIAN DETAIL W1 s ss SEWER MAIN (SIZE NOTED)
811 PRIOR TO CONSTRUCTION. 3. NO PERMANENT STRUCTURES CAN BE WITHIN AN EASEMENT OR OVER A SEWER/WATER Water Plan
MAIN.THIS INCLUDES BUILDINGS, CARPORTS,TRASH ENCLOSURES,TREES, OR DEEP 3/4"DOUBLE WATER SERVICE PER CITY OF MERIDIAN DETAIL W3 PIRR PRESSURE IRRIGATION (SIZE NOTED) Water Plan
PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE ROOTING BUSHES.
W5 WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY(I.E. ■■m■m■m■m■m■■ WATER SERVICE SLEEVE
SEEPAGE BEDS, DRAINAGE SWALES). 4. WHERE WATER MAINS ARE TO BE INSTALLED ON A RADIUS, PIPE JOINT DEFLECTION
"= SHALL NOT EXCEED ONE-HALF THE PIPE MANUFACTURER'S MAXIMUM ALLOWABLE
DEFLECTION.
C5mO3