Loading...
HomeMy WebLinkAboutC5.02_Water Plan Water Plan d� = T H E W,000 LAND \<� - G R O U P W2 \ B8 L2 \\ ��, \� B1 L40 See Sh 3\ INSTALL 8"22.51 ELBOW \ \ \ o \ B7 L18 \ \ • ,, r wa \ W/ HRUST LOCK T / \ B4 L18 \ w \ B7 L10 \ W2 \ \ d \ �- \\ W2 C-D W2 See Sheet C5.0$ \ \ 1 \ W1 C� \ J B8 L3 INSTALL 8"22.51 ELBOW "' \ \ B7 L19 \ W2 \ W/THRUST BLOCK -�- - - - \ B4 L19 \ \ \ \ PER ISPWC SD-403 8"SS - / W2 \ \ \ B7L9 �� ' 1 53/I - --- - - - -- \ ? W2 -- // ti CU - 64 L20 \ B7 L20 \ -------- - 8"W W1 / co \ i w \\ \ o W2 \\\ B7 L8 Cla- - $t ___-- - INSTALL 8"45,ELBOW \ s \ \ \ _ W/THRUST BLOCK PER ISPWC SD-403 cry B4 L21 \\ W2 \ _ INSTALL 8"TE _ ----- / _, N 2-81,GATE VALVESio _ s \ \I \ _ ' W/THRUST BLOCK PER ISPWC SD-4031\ I 1 - -_- - - - W \ r \ e�i� INSTALL 8 L.F. 6"WATER MAIN ' _ -- - - - W 1 \ 0,I \ 1-61,FIRE HYDRANT PER CITY OF MERIDIAN W8 1 B7 L21 '\ W2 - - - C4 W CA \ 1 W/THRUST BLOCK PER ISPWC SD 403 a - a Cm MCC \ 0 1 B7 L7co own ift s B4 L22 ICD ~ ' cr- 1 c) W2 '1 B1 L43 ' W2 \ - d I z CL \\ o \\ W COD CIO 1 1 \ \ I T J I I I B7 L22 I ca I 4'MIN I INSTALL 8 L.F. 6"WATER MAIN O d? 1 1 I 3 1-61,FIRE HYDRANT PER CITY OF MERIDIAN W8 B1 L4 '3 I W/THRUST BLOCK PER ISPWC SD-403 I >� B4 L23 W2 I 4 MIN I B7 L6 I ' CIO CM CD \ '17 ' 4 PIRR CODI _ i Q � � ,1 I _ - \ 1� � 11 PIRR _ , W2 I - - I I W 0 H W2 B1 L44Cm also I I I 1 _ _ \ B4 L24 \ I \ B7 L23 I I 1 1 I I I II B7 L5 I W2 1 1 1 _ _ I I w2ICC ' I M I cc Q - B4 L25 I W2 a ca W2 O I I I N I 131 L45 I co ' I I I ILu B7 L24 _ - - I ' W2 I B7 L4 I II I I 1 _ I I I I Revisions I ' 50 II - - 1. AGENCY COMMENTS 07-28-25 - 1 - B4 L26 I I - - I I I I I � - I In- ® I I N l a I I Iv � I 60 1 I — I II co Ii i d- � II � _ ' 131 L46 - _ I B7 L25 See Sheet C .01 I - _ - o- See Sheet C5. 1 I 67 L380 _r I d I I I N W2 ' W2 � o I I B4 L27 I I W2 I CD - 1 - r ater Plan 3°' 6°' / Horizontal Scale: 1" = 30, �- SZONAL E1V �G\ST G'1� Keynotes: Sheet Notes: Legend: W1 POTABLE WATER MAIN CROSSING-SEE WATER NOTE NO. 2 ON THIS SHEET. 1. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROPRIATE 8V 8"WATER MAIN (OR AS NOTED) 8°w EXISTING WATER MAIN 10961 LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL POTABLE/NON-POTABLE WATER SERVICE CROSSING-SEE WATER NOTE NO. 3 ON EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY 2" BLOW-OFF ASSEMBLY PER CITY OF MERIDIAN DETAIL W13 O® EXISTING BLOW-OFF ASSEMBLY 9q�e OF \oP�o W2 THIS SHEET. RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY HIS FAILURE TO J so1V DEN EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. ® GATE VALVE ® EXISTING GATE VALVE 8"or 12" C900 CONDUIT FOR PRESSURE IRRIGATION, PLACE REBAR AT BOTH ENDS 0712512025 W3 FOR LOCATING PURPOSES. SEE PRESSURE IRRIGATION PLANS FOR LENGTHS. 2. MIDSECTION LINE WATER MAINS SHALL HAVE 5 FEET OF COVER, IN ALL OTHER AREAS FIRE HYDRANT PER CITY OF MERIDIAN DETAIL W8 -(5 EXISTING FIRE HYDRANT Project No.: 121172 PROTECT IN PLACE ALL EXISTING UNDERGROUND UTILITIES AND SURFACE COVER SHALL BE 4 FEET. Date of Issuance: 07-28 2025 W4 APPURTENANCES. LOCATE ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. CALL - 3/41,WATER SERVICE PER CITY OF MERIDIAN DETAIL W1 81ISS SEWER MAIN (SIZE NOTED) Project Milestone: PERMIT SUBMITTAL 811 PRIOR TO CONSTRUCTION. 3. NO PERMANENT STRUCTURES CAN BE WITHIN AN EASEMENT OR OVER ASEWER/WATER Water Plan MAIN.THIS INCLUDES BUILDINGS, CARPORTS,TRASH ENCLOSURES,TREES, OR DEEP 3/41,DOUBLE WATER SERVICE PER CITY OF MERIDIAN DETAIL W3 PIRR PRESSURE IRRIGATION (SIZE NOTED) " PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE ROOTING BUSHES. Water Plan s W5 WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY(I.E. •■■■■■■■■■■■• WATER SERVICE SLEEVE SEEPAGE BEDS, DRAINAGE SWALES). 4. WHERE WATER MAINS ARE TO BE INSTALLED ON A RADIUS, PIPE JOINT DEFLECTION T SHALL NOT EXCEED ONE-HALF THE PIPE MANUFACTURER'S MAXIMUM ALLOWABLE DEFLECTION. �o C5mO2