HomeMy WebLinkAboutC5.01_Water Plan Water Plan T H E
LAND
0 CD I _ — - GROUP
B4 L26
O I �
II II N O�I O• II — — I I ' � � S Sh 5.02
O° I
- d I _
I I C I e Shee C5.02 o
H I 131 L46
I B7 L25 I
I I B7 L3 ► I
I I W21 W2 I
I B4 L27 i I I I oo I
W2
CD
— — — — — —
ao I — — � I �
a I - - - s � i I CLUBHOUSE UNDER
_ o I"� c ' � O F 6
— d I Np I '
IN STALL 8-IN CROSS N - SEPARATE PERMIT L - � o
o I I INSTALL 3-8"GATE VALVES I I I
I I L,,
Isoma
_ ----- 6 \0\PN F
r I I o W2 I B7 L2 I B7 L26 I I 61 L47 I L M��Np,VS�
W I I INSTALL 8-IN CROSS I oo p —
W CA CD
rF
B4 L28 I INSTALL 3-8"GATE VALVES W2 I DEFLECTION ANGLES NOT TO
I INSTALL 8 L.F. 6 WATER MAIN —
Cm o% I I I O I I EXCEED MANUFACTURER'S S o _
1-61, FIRE HYDRANT PER CITY OF I I SD
co � Am EROEIOVE BLOW-OFF AND CONNECT I I � I MERIDIAN W8 � — —— — — — — — REQUIREMENTS —
_ _ EXISTING 8-IN WATER MAIN I I W/THRUST BLOCK PER ISPWC SD-403 l — — — —
pp _ _ U r
9
— — —
LL-
H = _ _ - - - - - - - - cn B7L1
o>
`°
y B4 L29 0o ___---- ----- 76- F 8 N
---- --- -
102-LF 8-IN C90
_ I ---811W3 LF 8 I W _ _
e.:.
8"W
-------- 8"W 2 8-IN _ __-
811 — _
233-LF 8-IN C900 � oc _ g"S z
39-LF 8-IN C900 _ W2 —
8"SS o
811W 811w 13511
-LF 8-IN C900 _ — W2 — 8"SST 8"SS — 8" 8SS w3
8"ss O W Rio De Plata or w3 o W1 SD N
8"SS --- o o —
77
--- ----------
SD
--- - -- - --- ------------------------ z� 0 0 SD __
------------------------------ o SD a
o SD , _ _
- o o — e o B9 Li 4"PIRR
UJ
----------------- I z a J 4"PIRR — —— — — — — — —
PA
J B6L1 `� - -- - - -- - - - -- - - - — — —— _ - - - - - -- - - -- - - — — Jx
Mollie
B5L3 0 - - -- - - -- - - -- - - - - - - - -- - - -- - - — — — —
uu-or s -- — —— — — —— — — —— — W2 r�
— — — — — — — � W1 I
YJ
W2
w2 I
9
nq 65 L4 I I B6 L2 I I 3 I B9 L2
_02- I W2 I I B6 L3 I ao INSTALL 8 L.F. 61,WATER MAIN
1,I 1-6 FIRE HYDRANT PER CITY OF
MERIDIAN W8 -
- —I— — W/THRUST BLOCK PER ISPWC SD-403
INSTALL BLOW-OFF ASSEMBLY PER CITY OF _ _ _ — — — —
_ INSTALL BLOW OFF ASSEMBLY PER CITY OF CA
GRAVEL ACCESS ROAD �� MERIDIAN DETAIL W13 -o"' — — — -J MERIDIAN DETAIL W13
FUTURE PHASE 4 GRAVEL ACCESS ROAD
CD
Water Plan FUTURE PHASE 4 0 30 60 W O
Horizontal Scale: 1" = 30, _ Cm am
a co
OCm
FUTURE PHASE 3 FUTURE PHASE 3 0 _
I � ,o
cn - I pC / INSTALL BLOW-OFF ASSEMBLY
co INSTALL 8 L.F. 6"WATER MAIN 0
Sp � � - -- � INSTALL BLOW-OFF ASSEMBLY PER CITY OF 1-6"FIRE HYDRANT PER CITY OF MERIDIAN W8 Wi � PER CITY OF MERIDIAN DETAIL W12 � —
INSTALL 8 L.F. 6"WATER MAIN
MERIDIAN DETAIL W12 z
1-61,FIRE HYDRANT PER CITY OF i W/THRUST BLOCK PER ISPWC SD-403 cc
O INSTALL 8 L.F. 6"WATER MAIN — — — _ _ Q
p MERIDIAN W8
1-61,FIRE HYDRANT PER CITY OF MERIDIAN W8
W/THRUST BLOCK PER ISPWC SD-403 o I p W/THRUST PER ISPWC SD-403
O , NSTALL 12"x8"x8"TEEcc B12 Li C4
w
INSTALL 8"x8"x12"TEE 2-81,GATE VALVE
2-81,GATE VALVES &1-121,GATE VALVE W/THRUST BLOCK PER ISPWC SD-403 y �_ - — — —— B11 L
V C9�0 M W/THRUST BLOCK PER _ — — ------ _ Revisions
ISPWC SD-403 _ 81N ---------_------
_ BnN _ INSTALL 90,ELBOW 1. AGENCY COMMENTS 07 28 25
INSTALL 11.25,ELBOW
8/N —
EXCEED MANUFACTURER'S
- - - DEFLECTION ANGLES NOT TO — — — z __------- $ 1-8"GATE VALVE
--
REQUIREMENTS -------------- 224�Lv8-IN C900 — — _- _`" --- ---- W/THRUST BLOCKS PER ISPWC SD-403
\ --- z� wi - --
104- ------- 8"W _
�F8-IN -----
--
C900 53-LF 8-IN C900 33-LF 8-IN C900 — o
"w
---- 1 1 L4
110-LF 8-IN C900
�\ _ _ — —
Q N wi ZA -------WRio ----- __ — _ —_ _ - - --_ �`_
W3 W1
--- De Plata Dr m
\\\ C J v -- —
6, ► _ —
`� — — 3 W6
o
R8AI 1 �
FUTURE PHASE 4 L- y - - - — X B10 L1 — 1 a 1 L2— ` _ -_ FUTURE PHA E 3
y-— —— INSTALL BLOW-OFF ASSEMBLY PER CITY OFS
_ _ _ - - — ��
- -� MERIDIAN DETAIL WI3 - ---- - - -- - - -- - - -- -
Water Plan ' w6 FUTURE PHASE 3 0 30' 60' ��SZp SAL EN01
Horizontal Scale: 1" = 30,
Keynotes: Sheet Notes: Legend: 10961
e of \oP�o
W1 POTABLE WATER MAIN CROSSING-SEE WATER NOTE NO. 2 ON THIS SHEET. 1. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROPRIATE s w 8"WATER MAIN (OR AS NOTED) s w EXISTING WATER MAIN `l`�S
LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL oN DEN
W2 POTABLE/NON-POTABLE WATER SERVICE CROSSING-SEE WATER NOTE NO. 3 ON EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY 2" BLOW-OFF ASSEMBLY PER CITY OF MERIDIAN DETAIL W13 0® EXISTING BLOW-OFF ASSEMBLY 07/2W 2025
THIS SHEET. RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY HIS FAILURE TO
EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. Project No.: 121172
• GATE VALVE ® EXISTING GATE VALVE
d W3 8"or 12" C900 CONDUIT FOR PRESSURE IRRIGATION, PLACE REBAR AT BOTH ENDS Date of Issuance: 07-28-2025
FOR LOCATING PURPOSES. SEE PRESSURE IRRIGATION PLANS FOR LENGTHS. 2. MIDSECTION LINE WATER MAINS SHALL HAVE 5 FEET OF COVER, IN ALL OTHER AREAS l Project Milestone: PERMIT SUBMITTAL
T FIRE HYDRANT PER CITY OF MERIDIAN DETAIL W8 EXISTING FIRE HYDRANT
PROTECT IN PLACE ALL EXISTING UNDERGROUND UTILITIES AND SURFACE COVER SHALL BE 4 FEET. Water Plan
W4 APPURTENANCES. LOCATE ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. CALL N PERMANENT STRUCTURESCAN BE WITHIN AN EASEMENT R OVER ASEWER/WATER 3/41,WATER SERVICE PER CITY OF MERIDIAN DETAIL W1 s°ss SEWER MAIN (SIZE NOTED)
811 PRIOR TO CONSTRUCTION. 3 0 S 0 0 Water Plan
MAIN.THIS INCLUDES BUILDINGS, CARPORTS,TRASH ENCLOSURES,TREES, OR DEEP — 3/41,DOUBLE WATER SERVICE PER CITY OF MERIDIAN DETAIL W3 PIRR PRESSURE IRRIGATION (SIZE NOTED)
T PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE ROOTING BUSHES.
W5 WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY(I.E. WATER SERVICE SLEEVE
SEEPAGE BEDS, DRAINAGE SWALES). 4. WHERE WATER MAINS ARE TO BE INSTALLED ON A RADIUS, PIPE JOINT DEFLECTION
t C5 .,01
LABEL/TAG EACH WATER METER SETTER WITH LOT AND BLOCK SERVED BY METER. SHALL NOT EXCEED ONE-HALF THE PIPE MANUFACTURER'S MAXIMUM ALLOWABLE
s d g W6 DEFLECTION.
METER SHALL HAVE TRAFFIC RATED LIDS