Loading...
HomeMy WebLinkAboutC4.10_Sanitary Sewer Line G U �I B7 L19 B7 L18 B7 L15 W Evening Sun St - — — _ _ I Sheet Notes: ��_„ M I O B7 L17 B7 L16 M 4 a N 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB &GUTTER, STORM DRAIN, r ��' T H E + c I N I II O O4 4 4 O 1 z M � CHANNEL CROSSINGS, &SEWER ELEVATIONS OR INVERTS PRIOR TO �, ) + J `� I o I co O I O I + J o CONSTRUCTION AND NOTIFY ENGINEER WHEN ELEVATIONS OR INVERTS DO NOT . LAND Q L.L N M C3) p co O E �� O O p p . C! O w O M C'n0 + J M O M O 1 Ch O 'A m co I MATCH PLANS. GROUP + m m I r` co �- cfl Q m m U_ CV N p 0 + J r O + J C3� -� Q LWi N C n O w O C�J N O + J 6� + J O O r (n �W "' `� N o CO"' �; ° �, O° CO "� 1 I I 2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN cn o LLi N ¢ L:L_ N ¢ LL N U_ cv O I + B1 L32 cn o `—" c~ o w c i o w "' o `—" j r„ I y I APPROPRIATE LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY HIS - ------- Q� I a FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND T0.40% ----- --- -��8„SS 740 ------ - ------- _ UTILITIES. -O _ ----------- o SSMH 25 = - --------- -------- O 271-LF OF 8-IN PVC AT 0.40%8 SS 13.47 * m _ v _0 3. PROFILE ALIGNMENT REPRESENTS PIPE CENTERLINE. STATIONING IS GIVEN TO 8"SS, 64+00 175 SSMH 49 8„S$ 85-LF OF 8-INN PVC AT 3.60 ° LU _ — — — I 3 CENTER OF STRUCTURES UNLESS NOTED OTHERWISE. 2 � � - -- - - _ -�--- 0 - 2 n v 6'0 � --- - a, 4. ALL PIPE INSTALLATION AND TRENCHING SHALL CONFORM TO THE LATEST EDITION ----,_----___ 8 W 81W 2 S Country View Way 2 SSMH 50 `9 + OF ISPWC DIVISION 300 AND SD-3011. - 8"W 81W 811W 81.W o o BEDDING FILL SHALL BE CONSTRUCTED PER SECTION 305 AND 3060E THE ISPWC. ------- ----------- o STA:40+08.43 : OFF:45'L # 2659.7 5. NO PERMANENT STRUCTURES CAN BE WITHIN AN EASEMENT OR OVER A c. i B1 L33 SEWER/WATER MAIN.THIS INCLUDES BUILDINGS, CARPORTS,TRASH ENCLOSURES, a'� ^' TREES, OR DEEP ROOTING BUSHES rn � 1 Ln Ln I N r` z m cm pNC c6 O CV LO r` I uu ' a I Cfl LC) c O �Q � w � � I J ' m m U&3 ' I B8 L2 j � ; W I E = 0+64.20 ,- COD SSMH 26 4 T L m I W �,, NP�S P` � 659.5 W �F F r ' COD ° $� , , nc e M J Keynotes: CID Y e ti U') B1 L34 1. POTABLE WATER MAIN CROSSING-SEE SEWER NOTE NO. 2 ON SHEET C1.00. Line G 0 30' N 2. POTABLE/NON-POTABLE SERVICE CROSSING-SEE SEWER NOTE NO. 3 ON SHEET Horizontal Scale: 1" = 30' C1.00. ■ . ■ 2679 2679 3. NOT USED. W Sewer Line G.: Sta. 62+10 - 65+70 y HORIZONTAL SCALE- 111 — 30' 4. 4.INSTALL 4-IN SEWER SERVICE AT A MIMIMUM 2%GRADE TO LENGTH SHOWN PER mime VERTICAL SCALE- 1 II — 31 ISPWC SD-511. CAP AND MARK PER MERIDIAN SD SW3. Q 2676 2676 CL 2673 2673 Q 0 CD C 2670 2670 W Q C3also Q � 2667 EXISTING GROUND AT CENTERLINE PIPE 2667 O 0 2664 2664 Q c z Q PROPOSED GROUND AT CENTERLINE PIPE CA 2661 A 2661 Q QWATER SERVICE STORM Revisions 1-- CROSSING 12-IN PVC CROSSING 1. AGENCY COMMENTS 07-28-25 2 WATER SERVICE 2658 CROSSING 2658 2655 2655 271-LF OF 8-IN PVC AT 0.40% 8S'�F OF8 SSMH 50 gT3 ° 2652 5 48-IN DIA. PER ISPWC SD-501 600 STA: 64+49.27, 0.00, I RIM: 2663.22-t IE IN: 2653.77, 8-IN PVC (S) ��SZON T ENC ��G\ST 2649 IE OUT: 2653.69, 8-IN PVC (N) SSMH 25 2649 48-IN DIA. PER ISPWC SD-503 STA: 65+33.93, 0.00' 10961 RIM: 2664.34± IE IN: 2650.64, 8-IN PVC (SE) J qTE OF \pP �4sON 2646 IE IN: 2650.64, 8-IN PVC (S) 2646 DEN IE OUT: 2650.54, 8-IN PVC (W) 0712512025 Project No.: 121172 3 EXISTING GROUND ELEVATION PROPOSED GROUND ELEVATION Date of Issuance: 07-28-2025 AT CENTERLINE PIPE AT CENTERLINE PIPE Project Milestone: PERMIT SUBMITTAL 2643 2643 m CID M m �, o N O N Lf> Sanitary Sewer 0') I� r N Cq 00 O ti N (D N T CA � co C.C') � N N l!') W � � Line G LC� LC� LIJ LO LC') CO LC� LC') Lf7 LC') l.f� CO M CO M CO M CO M CO CO CO co CO M CO M CO M CO C6 CO C6 CO 4 CO CD CO O C0 O CO CD C0 O CO C0 O CO O CO O CO O CO O CO O CO co C0 N O N O N O N O N CO N O N O N O N O N O N co N O N co N N N N N N N N N N N N N w E� 62+10 62+40 62+70 63+00 63+30 63+60 63+90 64+20 64+50 64+80 65+10 65+40 65+70 _- C4ml 0 ��o