HomeMy WebLinkAboutC6.01 Pressure Irrigation Plan %. T H E
w ,
1 LAND
x
GSA � •
1 — - G R O U P
PRESSURE IRRIGATION w '
RISER (TYP). SEE SHEET C6.02.
CONNECT TO EXISTING VALVE '
' PRESSURE IRRIGATION SLEEVE (TYP).
SEE SHEET C6.02. '
554-LF 6-IN PI ca
6 PIRR 6 PIRR 6 PIRR 6 PIRR 6 PIRR 6 PIRR G' G z
JT x G I G
II W
Mw
I '
R/W R/W R/W R/W R/W _.... o R/W R/W
W
.02
LU "W 12" 12"W 12"W
1
1
W. Grand Mogul Dr
§_5 A 8"SS — S
N23+00 8"SS 8ASS 2 21+00 20+00 S 8"SS �8"SS 8"SS S �Xr r
C.'S' SAN ' .\
HERE IRRIGATIONEEVE(TYP).
HEET C6.02.
_134W R/W_ R R/W R/W R/W R/W R/W R/W R/W
o R —
18 SD 0 1 18 SD 8 SD O II O 18"SD 18'SD 18" D 18"S 18"SD 18"SD �60 O
Z
evee
6"PIRR 6"PIRR 6"PIRR 6"PIRR 6"PIRR PIMP 6"PIRR 6"PIRR 6"PIRR 6"PIRR 6"PIRR °° y
453-LF 6-IN PI 453-LF 6-IN PI
' W ■
P� 42-(F 6-lN p/R �
I ■
VALVE PRESSURE IRRIGATION SLEEVE (TYP). INSTALL 11.5°ELBOW
SEE SHEET C6.02.
CONNECT TO EXISTING VALVE 61,PIRR
ON
I
2.
- l
Pressure Irrigation Plan 20 40 Mhc
1600
Horizontal Scale: 1" = 20' cc ■
INSTALL BLOW-OFF ASSEMBY C2
PRESSURE IRRIGATION PRES
RISER (TYP). SEE SHEET C6.02.
X PRESSURE IRRIGATION X' RISER (TYP). c
' RISER (TYP). SEE SHEET C6.02. PRESSURE IRRIGATION SLEEVE (TYP). ■�
INSTALL 6-IN GATE VALVE INSTALL 6-IN GATE VALVE SEE SHEET C6.02. ' PRESSURE IRRIGATI �
EP
in
6„44mmF 6-IN PI y "PIRR67 LF 6-IN PI 6"PIRR 4FIR 6"PIRR 6"PIRR 6"PIRR 6"PIRR 1�554-1_F 6-IN PI 6"PIR 51-LF 6-IN PI O 6"PIRR 6"PIRR 6" R PIRR 6"PIRR
6d6 Idy
o
� P1
P2
R/W I RIV R/W R/W R/W R/W °� R/W R/W R/ R/W R/W R'' R/W
O
12"W 12"W x X 12"W k 1 'W 12"W 12"W 12"W 12"W 12"W x X x x 12"W 12"W 12" 12"W IN 0
PRESSURE IRRIGATION SLEEVE (TYP). PRESSURE IRRIGATION SLEEVE (TYP). ' y C z
,`; SEE SHEET C6.02. SEE SHEET C6.02. ,m O Q
COD :— — — — — — — — — — — — — — — — — — — ■ o
a 00 27+00 26+00 25+00 4�+�00 p ccc
W ii ii ii ii ii ii SAN "SS 8"SS 8"SS — -T B��JJ u'�J I_I_I
S 8"SS 8"SS 8 SS 8 SS 8 SS 8 SS 8 SS 8 SS 8"SS U JJ U
Rom
W. Grand Mogul Dr PRESSURE IRRIGATION SLEEVE (TYP).
SEE SHEET C6.02.
Revisions
— — — — — — — — — — — — — — — — — —
R/W- R/W — R/W �/W 3 W _R/W — R/W R/1(1L R/W / ao R/W R/� 1.
O I 18"SD 1 "SD 18" D 18"S18"SD 18"SD 8"SD O �0 P1 18"SD 18" D 8"SD O
W4L66"PIRR 6"PIRR 6"PIRR6"PIRR 6"PIRR 6"PIRR 6"P R X 6"PIRR "PIRR 6"PIRR — 6"PIRR
340-LF 6-IN PI P P 453-LF 6-IN
' PRESSURE IRRIGATION SLEEVE (TYP).
EP '
SEE SHEET C6.02. 67-LF 6-IN PI
INSTALL 6-IN GATE VALVE PRESSURE IRRIGATION SLEEVE
' INSTALL BLOW-OFF ASSEMBLY PRESSURE IRRIGATION o ' SEE SHEET 1
RISER (TYP). SEE SHEET C6.02. P2 PRESSURE IRRIGATION
INSTALL 6-IN GATE VALVE
' PRESSURE IRRIGATION SLEEVE (TYP). RISER (TYP). SEE SHEET C6.02. '
SEE SHEET C6.02. ,
Pressure Irrigation Plan ° 20 40 $Z0NALE
Horizontal Scale: 1" = 20' 0� �G\ST
Pressure Irrigation Notes: Sheet Notes: Keynotes:
10961
1. INSTALL ALL CROSSINGS OF THE PUBLIC RIGHTS-OF-WAY, PRIVATE ROADWAYS AND TRAVELWAYS WITH PRESSURE IRRIGATION AT A MAXIMUM DEPTH OF TWO-AND 5. LABEL ALL IRRIGATION RISERRS AND FAUCETS WITH DURABLE TAGS CARRYING THE WARNING DANGER-UNSAFE WATER OR NON-POTABLE WATER. 1. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROPRIATE P1 POTABLE WATER MAIN CROSSING-SEE NOTE NO.3 ON THIS SHEET.
ONE-HALF(2-1/2) FEET AND IN AN AWWA C-900 PIPE SLEEVE WITH LOCATOR WIRE.THE PUBLIC WORKS DEPARTMENT AND ACHD SHALL INSPECT ALL CROSSINGS LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL O 9TE OF �pP
PRIOR TO BACKFILLING. 6. LABEL ALL VALVE BOXES AND VAULTS WITH DURABLE TAGS CARRYING THE WARNING DANGER-UNSAFE WATER OR NON-POTABLE WATER.THE VALVES AND BOXES EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY P2 C900 PVC SLEEVE/CONDUIT. DIAMETER SHALL BE TWO TIMES THE �soNDL14
ARE TO BE LOCATED A MINIMUM OF TEN (10) FEET OUTSIDE OF THE PUBLIC RIGHT-OF-WAY, PRIVATE ROADWAYS AND TRAVELWAYS. RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY HIS FAILURE TO DIAMETER OF THE PRESSURE IRRIGATION MAIN. 0-7/23/2o25
2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS (SANITARY SEWER, STORM DRAIN,AND IRRIGATION) SHALL BE A EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
MINIMUM OF TEN (10) FEET.WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) 7. INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER IN ANY CONNECTION BETWEEN THE POTABLE WATER SYSTEM AND THE PRESSURE IRRIGATION SYSTEM.THE Project No.: 124186
INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING DEVICE MUST BE APPROVED BY THE IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY(DEQ)AND THE CITY OF MERIDIAN WATER DEPARTMENT. 2. SEE SHEET C6.02 FOR NAMPA-MERIDIAN IRRIGATION STANDARD DETAILS. Date of Issuance: 07-23-2025
WATER SYSTEMS (IDAPA 58.01.08)AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16). Project Milestone: FINAL PLAT SUBMITTAL
8. ALL PRESSURE IRRIGATION PIPE SHALL BE CONSTRUCTED TO SLOPE TO DRAINS AND/OR PUMP-OUT STATIONS AS SHOWN ON THE PLANS
a 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE WATER SERVICES OR POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX(6) FEET.
WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL 9. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH NAMPA-MERIDIAN IRRIGATION DISTRICT STANDARD SPECIFICATIONS FOR IRRIGATION DISTRIBUTION Pressure Irrigation Plan
E N SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA SYSTEMS.
58.01.08)AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16).
A 10. PRESSURIZED IRRIGATION SYSTEM IS AN EXTENSION OF THE EXISTING SOUTHRIDGE SUBDIVISION PHASE 1 SYSTEM.
4. INSTALL FINDER TAPE WITH ALL IRRIGATION MAINS. TAPE SHALL BE TWO (2) INCHES WIDE, METALLIC RED IN COLOR,WITH THE WORDS DANGER-UNSAFE WATER 10.1. SYSTEM IS OWNED AND OPERATED BY THE SOUTHRIDGE HOME OWNER'S ASSOCIATION. DEVELOPER IS IN DISCUSSIONS WITH NAMPA-MERIDIAN IRRIGATION
OR NON-POTABLE WATER CLEARLY MARKED ALONG ITS LENGTH. PLACE THE TAPE BETWEEN SIX(6) INCHES BELOW THE SURFACE AND EIGHTEEN (18) INCHES ABOVE DISTRICT REGARDING POTENTIAL OF TRANSFERRING SYSTEM TO N.M.I.D. C6m01
Off THE TOP OF THE PIPE. 10.2. SYSTEM IS CONNECTED TO CITY OF MERIDIAN POTABLE WATER SYSTEM FOR SECONDARY SOURCE.