HomeMy WebLinkAboutC4.50 Streetlight Plan 1 1 Sheet Notes: .,�
F&2;4 T H E
1. ALL CONSTRUCTION AND MATERIAL SHALL BE IN ACCORDANCE WITH THE IDAHO � 0
STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), CITY OF MERIDIAN LAND
STANDARDS,AND ADA COUNTY HIGHWAY DISTRICT STANDARDS. NO EXCEPTIONS ARE .
PERMITTED WITHOUT PRIOR WRITTEN APPROVAL. � G R 0 U P
1 1
2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN
APPROXIMATE WAY ONLY.THE CONTRACTOR SHALL COMPLY WITH IDAHO CODE,
CHAPTER 22,TITLE 55 REGARDING UNDERGROUND FACILITIES DAMAGE PREVENTION.
THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF EXISTING UTILITIES
BEFORE COMMENCING WORK.THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE
FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED AS A RESULT OF FAILURE
Ox O Y) TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES.THE CONTRACTOR SHALL
' STA: 25+64, OFF: 24.00'R —STA: 23+04, OFF: 24.001R ' O° CONTACT THE APPROPRIATE UTILITY COMPANIES OR DIG-LINE (342-1585) FOR EXACT
x Q 6"PIRR Q 6"PIR 6"PIRR 611P RR 6"PIRR 6"PIRR Q 6"PIPR LOCATIONS A MINIMUM OF 48-HOURS PRIOR TO DIGGING.
77
City of Meridian Standard Notes:
- - — - - - - W RW RW RW RW RW R RW RW RW RW 3 _-,
a ' 12"W x' k 12"W 12"W 12"W — x ' k 12"W 12"W X -x� x STREET LIGHTING
= f*u "
1. ALL STREET LIGHT CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THE
+ — I - W. Grand Mo ul Dr — — — — — W. Grand Mo ul DrCURRENT VERSION OF THE ISPWC,THE MERIDIAN SUPPLEMENTAL SPECIFICATIONS TO
29+00 8"SS 8" 8"SS 8"SS +0
�4+0� 8"SS 23+06SS22 J 20+00 THE ISPWC,AND THE NATIONAL ELECTRIC CODE.
R. — — — — 2. A STREET LIGHTING ELECTRICAL PERMIT SHALL BE OPENED PRIOR TO STARTING WORK.
o I o R/1l\� �W TO OPEN A PERMIT AND REQUEST INSPECTIONS, USE THE ONLINE CITIZEN PORTAL AT: r
o II I " o II 1811SD 18"$D 18
u u ii n https://citizenponal.meridiancity.org/citizenaccess/
611PIRR 611PIRR 611PIRR 6"PIRR x x 6"PIRR 611PIRR 611PIRR 611PIRR 611PIRR
' 8 ' 3. INSTALLATION WILL REQUIRE INSPECTIONS FOR THE CONCRETE BASE REINFORCING,
BEDDING, BACKFILL,AND FOR THE POLE AND ASSOCIATED WIRING.
4. STREET LIGHT BASES SHALL BE LOCATED 10' MIN. FROM TREES, 5' MIN. FROM FIRE
HYDRANTS AND 2' MIN. FROM WATER METERS.
5. KEEP ACCURATE NOTES OF CONDUIT,JUNCTION BOX LOCATIONS.ATTACH A REDLINED O
AS BUILT DRAWING OF THIS PLAN SHEET TO THE STREET LIGHTING ELECTRICAL ■
PERMIT, OR SUBMIT A HARD COPY TO THE MERIDIAN PUBLIC WORKS DEPARTMENT y
PRIOR TO REQUESTING FINAL INSPECTION. ■�
6. CONTACT THE CITY TRANSPORTATION AND UTILITY COORDINATOR (208) 898-5500 FOR
QUESTIONS REGARDING UTILITY CONFLICTS, OR TO ACCESS LOCKED METER ■
PEDESTALS.
1 1 Streetlight Keynotes: �O
Streetlight Plan 0 40' 80' 1. INSTALL TYPE 1 STREET LIGHT ON 30-FT POLE WITH 8-FT MAST ARM PER CITY OF
MERIDIAN PUBLIC WORKS DESIGN STANDARDS INCLUDING C.O.M. STANDARD DETAIL T1
Horizontal Scale: 1" = 40' AND T2.
Street Light Numbers: !c
� 0
LOCATION NUMBER TYPE
I-
STA 23+04 XXXXX TYPE 1
STA 25+64 XXXXX TYPE 1 ■
mime 0
y
o
Rom o
CD C z
Q
■ o
Ir
w
Revisions
1.
L
10961
COO, OF
9s0N DEN
a 0�/23/2�25
Project No.: 124186
Date of Issuance: 07-23-2025
Project Milestone: FINAL PLAT SUBMITTAL
Streetlight Plan
E
v E
CC50