HomeMy WebLinkAboutSITE PLAN V5 1 SHEET NOTES:
I
u u COVERAGE AREA CALCULATION
— —BI' rny1_ rnla1_ rnpll rn�1- nnr1- 1- rn PJ�
1 BP tY CY T FP tY hY tY CP hY —
8„W 8"W 1 8"W 8"W 8"Wryby- ti.8"W ry� LU AREA UNITS PERCENT
^� TOTAL AREA 87045.91 SF 100
®W�— LU
S.TOPAZ AVE.: -I¢
® 8„$$ U) „8 p2 BUILDING COVERAGE 24885.16 29
8"SS 8"SS�—$"SS
A"SS EXISTING PROPERTY ASPHALT&CONCRETE 36916.48 42
U) 81 assr�8"S$ 10'SETBACK_ X- BOUNDARY LINE Ite
-< � LANDSCAPE AREA 25244.24 29
EV PARKING
zi
SPACE
x
4 x 1 4 18, ' KEYNOTES:
I 9 I WATER WISE Il
U) — — — — — BUFFER o. 1. RESERVED FOR UNCOVERED VERTICAL INTEGRATED PARKING
(6 SPOTS).
II I MAINTENANC
SHOP 213R 26 6 6661 q I II 2. RESERVED FOR GUEST PARKING(4 SPOTS).
_— 2BR 2BR SF. 2BR 2BR 2BR 2BR a BLDG D
25 O O J w I 1 Oq 1 O 3. RESERVED FOR 3 BEDROOM OWNER PARKING.ONE SPOT PER
DRIVE AISLE N—w 1 Q 3 BR UNIT(3 SPOTS).
¢7 BLDG A 6 O 1 4. RESERVED FOR COMMERCIAL PARKING(20 SPOTS).
O ILL
GRASS PAVER/ 3131 2BR
EXISTING PROPERTY MAILBOX - -----
-- -- ——————————— FIRE ACCESS F EXISTING PROPERTY
BOUNDARY LINE � �� w w 1 °D I' I BOUNDARY LINE 5. PARKING ANALYSIS FOR BUILDING"D"IS GROUND FLOOR
<n SS„8 $$„g N�U` co I COMMERCIAL FLOOR AREA AT 7,987 SF/400 SF PER STALL=
\ \ sa "� 1 \ 20 STALLS REQ'D FOR GROUND FLOOR COMMERCIAL,PLUS
\ ¢ COMMERCIAL THE 2nd FLOOR THAT CONTAINS VERTICALLY INTEGRATED
UNDERGROUND -- ------- --- ------------ __ 1 I RESIDENTIAL,THE STALL REQUIREMENT IS AT 1.5 STALLS PER
SEEPAGE BED h I 26$g �_ I'" 2 OR 3-BED UNITS ADDING AN ADDITIONAL 6 REQ'D STALLS.
y 2BR 2 BR 1 10' 1 THUS 20+6=26 STALLS REQ'D FOR BUILDING"D",THUS 26
Z Y 1 1 SF7 TOTAL STALLS AS SHOWN IS IN COMPLIANCE FOR BUILDING
EXISTING PROPER / 2BR 2BR 2BR 5837 O w O 1 a ❑ D
2BR 2BR cnN 1 q z 6. ALL UNITS IN BUILDING"A","B"AND"C"CONTAIN A 2-CAR
SITE LINE i ~ SF' ¢ x I
w N�w 1 O 30' BIKE RACK � GARAGE WHICH ACCOMMODATES THE COVERED PARKING
6 a d UTILITY I �s� w STALLS.TOTAL PARKING COUNTS ARE IDENTIFIED AS
\ 'L/,• v / N F BLDG B w j 1 1 1 EASEMENT I 3 BR 1 ss� a O FOLLOWS:
\ w — O 4 I ui • BUILDING A HAVING 7 UNITS WITH 14 COVERED STALLS(14
BIKE REPAIR \� BIKE RACK 1 O REQ'D DUE TO(7)2-BED UNITS).
\ STATION -- — 25 I 4 PARKING REQUIREMENT FOR BUILDING A IS MET VIA
\ \ — — DRIVE AISLE
\ -- 1 1 W/PARKING THE GARAGES.
V) °3 3 S I O4 N o o • BUILDING B HAVING 7 UNITS WITH 14 COVERED STALLS(14
\ \ ?Z 4 o REQ'D DUE TO(7)2-BED UNITS).
_ __ ° L_ 4 1 PARKING REQUIREMENTS FOR BUILDING B IS MET VIA
z THE GARAGES.
�P\Sx\\ \\ EG °3 03 03 p 4 �20'UTILITY 1 I I ° ° NO y • BUILDING C HAVING 5 UNITS WITH 10 COVERED STALLS.
3 1 z PARKING REQUIREMENTS FOR BUILDING C THAT
4 EASEMENT LO 2 BR
\ 2 \ \\ 3 BR � 2BR SF. 2BR 3 BR + 1 1 1 p 1 CONTAINS(5)TOTAL UNITS,(2)OF WHICH BEING 2-BED
r— I UNITS AND(3)BEING 3-BED UNITS,CONTAINS 10
\ \\ 2 �\\ \\ 3 I �° 4 1 1 a a COVERED STALLS AND THE(3)ADDITIONAL STALLS
�� 3 BR ( SHOWN DIRECTLY NORTH OF BUILDING C AS
cp BLDG C 6 4 1 DO NOT ENTER/ o
4 KEYNOTED AS#3.
�P9� J(\V�t�C\ / 1 ONE WAY SIGN GUEST PARKING FOR MULTIFAMILY:1 STALL PER 10 UNITS IS
jo O REQUIRED FOR GUEST PARKING.19 UNITS REQUIRES(2)
\\ ❑ STALLS,AND THESE(2)STALLS HAVE BEEN SHOWN NORTH OF
_� _ _ o BUILDING B.
ILL Lu
O3 �>rp�� INFILTRATION BASIN 7 3 • TWO MORE GARAGE STALLS GOING ABOVE/BEYOND CODE
p , M.'s IN
o¢ 1 O o ARE SHOWN ON THE NORTHERN"MAINTENANCE SHOP"
o BBQ/PATIO \� PORTION OF BUILDING A,WHICH ARE TO BE USED AT THE
EG OWNER'S DISCRETION AS THEY ARE BEYOND CODE REQ'S.
— - EG �EE-��a Q _ O
\ Z
Z
\ W I �� D.
< ccn N r W 1 a EXISTING PROPERTY J fJ"
\ � w 1 0 LL BOUNDARY LINE °
z 170 p1L
w \ N Z In
O J In
j \ 1
1
Q \
� Io \\ I
N
NA L Fti
Z ��� ENSFO C�2 20' 0 20' 40LU
aSCALE OF FEET
19085
Jesse DESIGNED: SUB SHEET NO. DATE:
= REVISIONS TITLE OF SHEET
Q THIS DRREPR AND DUCEDE INFORMATION THOUTEXPRESSWRITIEDHEREIN MAY ISSION OT BE HECO COPIED ,^ O Z.MATHEWS JULY
OR REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION OF HECO H E C O Christen se V'-� P = OVERALL LAYOUT 2025
NO. DATE BY DESCRIPTION ENGINEERS. V DRAWN BY'Tc C O r� S.00HOA
UNAUTHORIZED DISCLOSURE OR CONSTRUCTION USE ARE PROHIBITED BY l> ` O r \ �`V:J PROJECT NO.:
COPYRIGHT LAW. /�LJp�,(�` DESIGN QC: 0 TOPAZ DEVELOPMENT PR24-0363
ORIGIN AL DOCUMENTS STORED AT: ENGINEERS Digitally signed by Jesse Christensen CHR� ` J.CHRISTENSEN C
HE CO ENGINEERS CORPORATE OFFICE Date:2025.08.2014:20:47-06'00' SHEET
N 32 N.MAIN,PAYETTE,IDAHO
DWG QC:
Z.MATHEWS MERIDIAN IDAHO 5 of 8
12"x18"ALUMINUM SIGN
® DISPENSER BOX
® REPAIR TOOL STATION
® 8-FT STEEL SIGN POST
BBQ GRILL 9WILl
® TIRE AIR INFLATOR
10-GAL WASTE RECEPTACLE
WITH ATTACHED LID
o
Y'z TYPICAL PET WASTE STATION TYPICAL BIKE REPAIR STATION
LU
l 0 C5.o NTS C5.o NTS
u L)¢
U 0
Z W tlNIJ Q
p ppp qI LU
U
p a-
s V d
0�
O
w
0
0
U
U
N
C7
Z_
G
BBQ GRILL
z
w
o_
O
w
w
0
N
Q
0_
O
H
5s
TYPICAL BBQ GRILL \o NA L Fti
a C5.0 NTS O�� \GENSF�
w
U
19085
= REVISIONS DESIGNED: SUB SHEET NO. TITLE OF SHEET DATE:
THIS DOCUMENTANDTHE INFORMATION CONTAINED HEREIN MAY NOT BE COPIED ,^ O Z.MATHEWS JULY
U OR REPRODUCED WITHOUT E%PRESS WRITTEN PERMISSION OFHECO HECO Jesse Christense v �l,
� NO. DATE BY DESCRIPTION ENGINEERS � �,9T P`Z` �� DRAWN BY: STANDARD DETAIL 2025
N
UNAUTHORIZED DISCLOSURE OR CONSTRUCTION USE ARE PROHIBITED BY F O F `G, S.OCHOA
COPYRIGHT LAW. Digitally signed b S \ PROJECT NO.:
9 Y 9 Y DESIGN oc PR24-0363
ORIGINAL DOCUMENTS STORED AT: ENGINEERS Jesse Christensen R. CI-IRIS J.CHRISTENSEN C5.0 TOPAZ DEVELOPMENT
HE ENGINEERS CORPORATE OFFICE SHEET
32 N.MAIN,PAVETTE,IDAHO Date:2025.08.20
14:21:03-06'00' rDWG QC: 9 9
.M ATHEWS MERIDIAN IDAHO of