Loading...
HomeMy WebLinkAboutSITE PLAN V5 1 SHEET NOTES: I u u COVERAGE AREA CALCULATION — —BI' rny1_ rnla1_ rnpll rn�1- nnr1- 1- rn PJ� 1 BP tY CY T FP tY hY tY CP hY — 8„W 8"W 1 8"W 8"W 8"Wryby- ti.8"W ry� LU AREA UNITS PERCENT ^� TOTAL AREA 87045.91 SF 100 ®W�— LU S.TOPAZ AVE.: -I¢ ® 8„$$ U) „8 p2 BUILDING COVERAGE 24885.16 29 8"SS 8"SS�—$"SS A"SS EXISTING PROPERTY ASPHALT&CONCRETE 36916.48 42 U) 81 assr�8"S$ 10'SETBACK_ X- BOUNDARY LINE Ite -< � LANDSCAPE AREA 25244.24 29 EV PARKING zi SPACE x 4 x 1 4 18, ' KEYNOTES: I 9 I WATER WISE Il U) — — — — — BUFFER o. 1. RESERVED FOR UNCOVERED VERTICAL INTEGRATED PARKING (6 SPOTS). II I MAINTENANC SHOP 213R 26 6 6661 q I II 2. RESERVED FOR GUEST PARKING(4 SPOTS). _— 2BR 2BR SF. 2BR 2BR 2BR 2BR a BLDG D 25 O O J w I 1 Oq 1 O 3. RESERVED FOR 3 BEDROOM OWNER PARKING.ONE SPOT PER DRIVE AISLE N—w 1 Q 3 BR UNIT(3 SPOTS). ¢7 BLDG A 6 O 1 4. RESERVED FOR COMMERCIAL PARKING(20 SPOTS). O ILL GRASS PAVER/ 3131 2BR EXISTING PROPERTY MAILBOX - ----- -- -- ——————————— FIRE ACCESS F EXISTING PROPERTY BOUNDARY LINE � �� w w 1 °D I' I BOUNDARY LINE 5. PARKING ANALYSIS FOR BUILDING"D"IS GROUND FLOOR <n SS„8 $$„g N�U` co I COMMERCIAL FLOOR AREA AT 7,987 SF/400 SF PER STALL= \ \ sa "� 1 \ 20 STALLS REQ'D FOR GROUND FLOOR COMMERCIAL,PLUS \ ¢ COMMERCIAL THE 2nd FLOOR THAT CONTAINS VERTICALLY INTEGRATED UNDERGROUND -- ------- --- ------------ __ 1 I RESIDENTIAL,THE STALL REQUIREMENT IS AT 1.5 STALLS PER SEEPAGE BED h I 26$g �_ I'" 2 OR 3-BED UNITS ADDING AN ADDITIONAL 6 REQ'D STALLS. y 2BR 2 BR 1 10' 1 THUS 20+6=26 STALLS REQ'D FOR BUILDING"D",THUS 26 Z Y 1 1 SF7 TOTAL STALLS AS SHOWN IS IN COMPLIANCE FOR BUILDING EXISTING PROPER / 2BR 2BR 2BR 5837 O w O 1 a ❑ D 2BR 2BR cnN 1 q z 6. ALL UNITS IN BUILDING"A","B"AND"C"CONTAIN A 2-CAR SITE LINE i ~ SF' ¢ x I w N�w 1 O 30' BIKE RACK � GARAGE WHICH ACCOMMODATES THE COVERED PARKING 6 a d UTILITY I �s� w STALLS.TOTAL PARKING COUNTS ARE IDENTIFIED AS \ 'L/,• v / N F BLDG B w j 1 1 1 EASEMENT I 3 BR 1 ss� a O FOLLOWS: \ w — O 4 I ui • BUILDING A HAVING 7 UNITS WITH 14 COVERED STALLS(14 BIKE REPAIR \� BIKE RACK 1 O REQ'D DUE TO(7)2-BED UNITS). \ STATION -- — 25 I 4 PARKING REQUIREMENT FOR BUILDING A IS MET VIA \ \ — — DRIVE AISLE \ -- 1 1 W/PARKING THE GARAGES. V) °3 3 S I O4 N o o • BUILDING B HAVING 7 UNITS WITH 14 COVERED STALLS(14 \ \ ?Z 4 o REQ'D DUE TO(7)2-BED UNITS). _ __ ° L_ 4 1 PARKING REQUIREMENTS FOR BUILDING B IS MET VIA z THE GARAGES. �P\Sx\\ \\ EG °3 03 03 p 4 �20'UTILITY 1 I I ° ° NO y • BUILDING C HAVING 5 UNITS WITH 10 COVERED STALLS. 3 1 z PARKING REQUIREMENTS FOR BUILDING C THAT 4 EASEMENT LO 2 BR \ 2 \ \\ 3 BR � 2BR SF. 2BR 3 BR + 1 1 1 p 1 CONTAINS(5)TOTAL UNITS,(2)OF WHICH BEING 2-BED r— I UNITS AND(3)BEING 3-BED UNITS,CONTAINS 10 \ \\ 2 �\\ \\ 3 I �° 4 1 1 a a COVERED STALLS AND THE(3)ADDITIONAL STALLS �� 3 BR ( SHOWN DIRECTLY NORTH OF BUILDING C AS cp BLDG C 6 4 1 DO NOT ENTER/ o 4 KEYNOTED AS#3. �P9� J(\V�t�C\ / 1 ONE WAY SIGN GUEST PARKING FOR MULTIFAMILY:1 STALL PER 10 UNITS IS jo O REQUIRED FOR GUEST PARKING.19 UNITS REQUIRES(2) \\ ❑ STALLS,AND THESE(2)STALLS HAVE BEEN SHOWN NORTH OF _� _ _ o BUILDING B. ILL Lu O3 �>rp�� INFILTRATION BASIN 7 3 • TWO MORE GARAGE STALLS GOING ABOVE/BEYOND CODE p , M.'s IN o¢ 1 O o ARE SHOWN ON THE NORTHERN"MAINTENANCE SHOP" o BBQ/PATIO \� PORTION OF BUILDING A,WHICH ARE TO BE USED AT THE EG OWNER'S DISCRETION AS THEY ARE BEYOND CODE REQ'S. — - EG �EE-��a Q _ O \ Z Z \ W I �� D. < ccn N r W 1 a EXISTING PROPERTY J fJ" \ � w 1 0 LL BOUNDARY LINE ° z 170 p1L w \ N Z In O J In j \ 1 1 Q \ � Io \\ I N NA L Fti Z ��� ENSFO C�2 20' 0 20' 40LU aSCALE OF FEET 19085 Jesse DESIGNED: SUB SHEET NO. DATE: = REVISIONS TITLE OF SHEET Q THIS DRREPR AND DUCEDE INFORMATION THOUTEXPRESSWRITIEDHEREIN MAY ISSION OT BE HECO COPIED ,^ O Z.MATHEWS JULY OR REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION OF HECO H E C O Christen se V'-� P = OVERALL LAYOUT 2025 NO. DATE BY DESCRIPTION ENGINEERS. V DRAWN BY'Tc C O r� S.00HOA UNAUTHORIZED DISCLOSURE OR CONSTRUCTION USE ARE PROHIBITED BY l> ` O r \ �`V:J PROJECT NO.: COPYRIGHT LAW. /�LJp�,(�` DESIGN QC: 0 TOPAZ DEVELOPMENT PR24-0363 ORIGIN AL DOCUMENTS STORED AT: ENGINEERS Digitally signed by Jesse Christensen CHR� ` J.CHRISTENSEN C HE CO ENGINEERS CORPORATE OFFICE Date:2025.08.2014:20:47-06'00' SHEET N 32 N.MAIN,PAYETTE,IDAHO DWG QC: Z.MATHEWS MERIDIAN IDAHO 5 of 8 12"x18"ALUMINUM SIGN ® DISPENSER BOX ® REPAIR TOOL STATION ® 8-FT STEEL SIGN POST BBQ GRILL 9WILl ® TIRE AIR INFLATOR 10-GAL WASTE RECEPTACLE WITH ATTACHED LID o Y'z TYPICAL PET WASTE STATION TYPICAL BIKE REPAIR STATION LU l 0 C5.o NTS C5.o NTS u L)¢ U 0 Z W tlNIJ Q p ppp qI LU U p a- s V d 0� O w 0 0 U U N C7 Z_ G BBQ GRILL z w o_ O w w 0 N Q 0_ O H 5s TYPICAL BBQ GRILL \o NA L Fti a C5.0 NTS O�� \GENSF� w U 19085 = REVISIONS DESIGNED: SUB SHEET NO. TITLE OF SHEET DATE: THIS DOCUMENTANDTHE INFORMATION CONTAINED HEREIN MAY NOT BE COPIED ,^ O Z.MATHEWS JULY U OR REPRODUCED WITHOUT E%PRESS WRITTEN PERMISSION OFHECO HECO Jesse Christense v �l, � NO. DATE BY DESCRIPTION ENGINEERS � �,9T P`Z` �� DRAWN BY: STANDARD DETAIL 2025 N UNAUTHORIZED DISCLOSURE OR CONSTRUCTION USE ARE PROHIBITED BY F O F `G, S.OCHOA COPYRIGHT LAW. Digitally signed b S \ PROJECT NO.: 9 Y 9 Y DESIGN oc PR24-0363 ORIGINAL DOCUMENTS STORED AT: ENGINEERS Jesse Christensen R. CI-IRIS J.CHRISTENSEN C5.0 TOPAZ DEVELOPMENT HE ENGINEERS CORPORATE OFFICE SHEET 32 N.MAIN,PAVETTE,IDAHO Date:2025.08.20 14:21:03-06'00' rDWG QC: 9 9 .M ATHEWS MERIDIAN IDAHO of