HomeMy WebLinkAboutPZ - Staff Report 09-04
City of Meridian | Department Report I. Project Overview
HEARING
DATE:
9/4/2025
TO: Planning & Zoning Commission
FROM: Linda Ritter, Associate Planner
208-884-5533
lritter@meridiancity.org
APPLICANT: Jadon Schneider, Bronze Bow Land
SUBJECT: H-2025-0013
Solara Estates Subdivision ALT, AZ,
PP
LOCATION: 1695 E. Amity Road, 4940 and 5060 S.
Locust Grove Road, located in the NW ¼
of Section 32, Township 3N, Range 1E.
Parcel(s) S1132223130, S1132223210
and S1132223320
PROJECT OVERVIEW
A. Summary
• Annexation of approximately +15 acres of land with a zoning designation of R-8 and R-2
from Rural Urban Transition (RUT) within Ada County;
• Preliminary Plat consisting of 19 lots on approximately 9.72 acres; and
• Alternative Compliance to reduce a portion of the landscape buffer along the street
adjacent to Lot 11, Block 1.
B. Issues/Waivers
• The applicant is requesting Alternative Compliance for Lot 11, Block 1, due to the impact
of the Ada County Highway District’s (ACHD) required right-of-way dedication and
associated improvements along Locust Grove Road. ACHD requires a fifty-foot (50')
right-of-way dedication from the centerline, pavement widening extending seventeen feet
(17') from the centerline, a three-foot (3') gravel shoulder, and a ten-foot (10') multi-use
pathway located 26.5 feet from the centerline adjacent to the site. When combined with
the City’s required twenty-five-foot (25') landscape buffer, these requirements
substantially reduce the usable area on Lot 11, Block 1, where the existing residence is
located. The applicant is therefore requesting Alternative Compliance to reduce the
required landscape buffer along the street frontage adjacent to Lot 11, Block 1 to twelve
and a half (12.5) feet.
• Currently, the church property doesn’t meet the landscape regulations of the UDC.
Therefore, the property is deemed as a non-conforming use and subject to the standards
outlined in UDC 11-1B-4. However, the property did receive CUP through the County
COMMUNITY DEVELOPMENT
DEPARTMENT REPORT
City of Meridian | Department Report I. Project Overview
and may continue to operate under that approval until future development is proposed for
the property.
• The church property at 1695 E. Amity Road currently has three (3) access points along E.
Amity Road and one (1) along S. Locust Grove Road. ACHD has not included any site-
specific conditions on this property since no development is currently proposed. Future
access will be evaluated at the time of development application in accordance with UDC
11-3A-3.
C. Recommendation
Staff recommends approval of the proposed annexation, preliminary plat, and the Director
approved the request for Alternative Compliance, in accordance with the provisions of Section IV
and the Findings in Section V.
D. Decision
Select: (Multi-combo)
City of Meridian | Department Report II. Community Metrics
COMMUNITY METRICS
Table 1: Land Use
Description Details Map Ref.
Existing Land Use(s) Church, vacant and residential -
Proposed Land Use(s) Church and residential -
Existing Zoning RUT VII.A.2
Proposed Zoning R-8 (Church Property) and R-2 (Residential Subdivision)
Adopted FLUM Designation Low Density Residential VII.A.3
Proposed FLUM Designation Low Density Residential
Table 2: Process Facts
Description Details
Preapplication Meeting date 1/14/2025
Neighborhood Meeting 1/30/2025
Site posting date 8/15/2025
Table 3: Community Metrics
Agency / Element Description / Issue Reference
Ada County Highway District IV.K
• Comments Received Yes/Staff Report -
• Commission Action Required No -
• Access Existing Arterial/ S. Locust Grove Road -
• Traffic Level of Service Locust Grove Road - Better than “E”
Amity Road – Better than “E”
-
ITD Comments Received No Comment IV.L
Meridian Fire No Comment IV.C
Meridian Police No Comment IV.D
Meridian Public Works Wastewater IV.B
• Distance to Mainline Sewer available in Locust Grove Road approximately 350’
north of Amity Road
• Impacts or Concerns The applicant is proposing to connect to a sewer shed
different from the one identified in the master plan. The
City Engineer has reviewed and approved the proposed
change. The applicant is permitted to tie into the existing
sewer line on Locust Grove Road.
Meridian Public Works Water IV.B
• Distance to Mainline Water available at the site
• Impacts or Concerns Approval of the water system is contingent upon obtaining
a variance to connect to Pressure Zone 5 instead of
Pressure Zone 4. All conditions and requirements
associated with the variance must be met, subject to
approval by the City Engineer. The variance has not yet
been issued. No connection to Pressure Zone 5 may occur
until written approval is provided by the City Engineer.
Note: See City/Agency Comments and Conditions Section and public record for all department/agency
comments received. Solara Estates Subdivision H-2025-0013 (copy this link into a separate browser).
City of Meridian | Department Report II. Community Metrics
Figure 1: One-Mile Radius Existing Condition Metrics
City of Meridian | Department Report II. Community Metrics
Notes: See VIII. Additional Notes & Details for Staff Report Maps, Tables, and Charts.
Figure 2: ACHD Summary Metrics
City of Meridian | Department Report II. Community Metrics
Notes: See VIII. Additional Notes & Details for Staff Report Maps, Tables, and Charts.
Figure 3: Service Impact Summary
Notes: See VIII. Additional Notes & Details for Staff Report Maps, Tables, and Charts.
Ready
Marginal
Caution
City of Meridian | Department Report III. Staff Analysis
STAFF ANALYSIS
Comprehensive Plan and Unified Development Code (UDC)
A. General Overview
The current Future Land Use Map (FLUM) designation for the properties is Low Density
Residential and the zoning district is RUT as the property is located within Ada County. This
designation allows for the development of single-family homes on large and estate lots at gross
densities of three dwelling units or less per acre. These areas often transition between existing
rural residential and urban properties. Developments need to respect agricultural heritage and
resources, recognize view sheds and open spaces, and maintain or improve the overall
atmosphere of the area. The use of open spaces, parks, trails, and other appropriate means should
enhance the character of the area. Density bonuses may be considered with the provision of
additional public amenities such as a park, school, or land dedicated for public services.
The applicant is proposing to annex and zone the properties to the R-8 and R-2 zoning districts.
The property located at 1695 E. Amity Road is proposed to be zoned R-8 to retain the existing
church use. The request for R-8 zoning is necessary because churches are prohibited in the R-2
and R-4 zoning districts. The City has received a copy of the approved Conditional Use Permit
(CUP) from Ada County for the existing church use, and any future expansions of the facility will
require CUP approval through the City. As part of annexation, the church will also be required to
connect to City services and abandon the existing well and septic system in accordance with UDC
11-3A-21.
The properties located at 4940 and 5060 S. Locust Grove Road are proposed to be zoned R-2 with
the approval of the preliminary plat to subdivide the parcels into 19 lots (14 building lots and 5
common lots). The existing home at 5060 S. Locust Grove Road will remain on Lot 11, Block 1,
and will be required to connect to City services and abandon the existing well and septic system.
At this time, the church is not requesting any modifications to the existing property or structures,
but has agreed to annexation solely to provide the path of annexation for the Solara Estates
Subdivision. Because the properties are under two separate ownerships, staff recommends two
separate development agreements to govern each property.
Table 4: Project Overview
Description Details
History CUP for the existing church
Phasing Plan 1
Residential Units Single-family Detached
Open Space 0.78 acres required/0.965 acres provided (9.9%)
Amenities 2 points required/2 points provided
Physical Features N/A
Acreage +15 acres
Lots 19 lots (14 building/5 Common)
Density 1.44 du/ac
B. History
The Church of Jesus Christ of Latter-day Saints received a Conditional Use Permit to build a
church on May 21, 1975.
The Bills’ property has an existing home, formerly used for pasture and agriculture, which will
remain on Lot 11, Block 1.
City of Meridian | Department Report III. Staff Analysis
C. Site Development and Use Analysis
1. Existing Structures/Site Improvements (UDC 11-1):
The property located at 1695 E. Amity Road is currently used as the Church of Jesus Christ
of Latter-day Saints, which will continue to operate as a church. This use is considered
nonconforming for street buffers and parking lot landscaping and may require the approval
of a conditional use permit to expand the non-conformity in accord UDC 11-1B-3.
Although no development or modifications are proposed for the property located at 1695 E.
Amity Road, staff recommends that the Commission and City Council evaluate the need for a
5-foot temporary sidewalk within the ACHD right-of-way on the west and north side of the
property. The sidewalks would provide a pedestrian connection from the south to the north
and east to west and wrap around to extend the entire length of the property along Amity
Road, as part of the annexation approval, as there are no existing sidewalks at this
intersection.
The property located at 5060 S. Locust Grove Rd. is currently used for residential and
agricultural purposes. It contains one (1) existing residence, which is proposed to remain.
Since the existing residence will no longer have access to Locust Grove, the applicant will
need to work with the City on a new home address with the platting of the property.
Both the existing church and residence will be required to connect to City services. As part of
this process, the existing wells and septic systems must be abandoned in accordance with
applicable regulations.
2. Proposed Use Analysis (UDC 11-2):
The applicant is proposing single-family detached homes which are listed as a principal
permitted use in UDC Table 11-2A-2 for the R-2 zoning district. The church requires a
conditional use permit in the proposed R-8 zoning district; subject to the specific use
standards in Chapter 4.
3. Dimensional Standards (UDC 11-2):
In the R-2 and R-8 zoning districts, a twenty-five (25) foot landscape buffer is required along
S. Locust Grove Road and E. Amity Road.
In the R-2 zoning district, the maximum building height is thirty-five (35) feet, with an
interior setback of 7.5 feet per story and a rear setback of fifteen (15) feet. The maximum
street frontage is eighty (80) feet. The proposed building lots range in size from 13,553
square feet to 61,912 square feet, all of which exceed the minimum lot size requirement of
12,000 square feet for the R-2 zone.
In the R-8 zone, the maximum height is also 35 feet with an interior setback of 5 feet and
arear setback of twelve (12) feet. Existing structures should conform with the height and
setback standards of the district which they appear to do.
D. Design Standards Analysis
1. Structure and Site Design Standards (Comp Plan 5.01.02A, UDC 11-3A-19):
The current use of the property located at 5060 S. Locust Grove Road is residential with one
(1) residential property existing. The structure will remain and the existing well and septic
system will be abandoned as required. City utilities are required to be extended to serve the
proposed development. The current use of the property that is located at 1695 E. Amity Road
is a church and will remain a church with the proposed annexation.
Comprehensive Plan Policy 5.01.02A requires the applicant to maintain and implement
community design ordinances, quality design criteria, and complete street policies to set
quality standards citywide.
City of Meridian | Department Report III. Staff Analysis
2. Qualified Open Space & Amenities (Comp Plan 2.02.00, Comp Plan 2.02.01B, UDC 11-3G):
Based on the standards in UDC Table 11-3G-3, a minimum of 8% (or 0.42-acres) for the R-2
zoning district. An open space exhibit was submitted as shown in Section VII.F, that depicts
9.9% (or 0.965 acres) of open space that exceeds the required qualified open space
standards. Based on the standards in UDC 11-3G-4A, a minimum of two (2) amenity points
are required as the overall project is ten (10) acres in size. The amenities proposed are an
outdoor fire ring, picnic table, bench and picnic shelter. All common open space areas are
required to be landscaped with one deciduous shade tree for every 5,000 square feet of area
and include a variety of trees, shrubs, lawn or other vegetative groundcover per UDC 11-3G-
5B.3.
Comprehensive Plan policy 2.02.00 requires the applicant to plan for safe, attractive, and
well-maintained neighborhoods that have ample open space, and generous amenities that
provide varied lifestyle choices.
Comprehensive Plan policy 2.02.01B requires the applicant to evaluate open space and
amenity requirements for consistency with community needs and values.
3. Landscaping (UDC 11-3B):
i. Landscape buffers along streets
UDC 11-2A-6 requires a twenty-five (25) foot wide buffer along arterial roads (Locust
Grove Road).
The applicant is requesting alternative compliance for a portion of the landscape buffer
along Locust Grove Road that borders Lot 11, Block 1 due to the existing structure (see
analysis below).
ii. Tree preservation
Per UDC 11-3B-10, the applicant shall preserve existing trees four-inch caliper or greater
from destruction during the development.
Mitigation shall be required for all existing trees four-inch caliper or greater that are
removed from the site with equal replacement of the total calipers lost on site up to an
amount of one hundred (100) percent replacement (Example: Two (2) ten-inch caliper
trees removed may be mitigated with four 5-inch caliper trees, five (5) four-inch caliper
trees, or seven (7) three-inch caliper trees). Deciduous specimen trees four-inch caliper or
greater may count double towards total calipers lost, when planted at entryways, within
common open space, and when used as focal elements in landscape design.
If trees are proposed to be removed from the property that meet the criteria listed above,
the applicant shall add a mitigation section to the landscape plan with the final platy
application.
iii. Storm integration
Per UDC 11-3B-11, the applicant shall meet the intent to improve water quality and
provide a natural, effective form of flood and water pollution control through the
integration of vegetated, well designed stormwater filtration swales and other green
stormwater facilities into required landscape areas, where topography and hydrologic
features allow if part of the development.
Development will be required to meet UDC 11-3B-11 for stormwater integration.
4. Parking (UDC 11-3C):
Off-street parking is required to be provided for each home based on the total number of
bedrooms per unit as set forth in UDC Table 11-3C-6. On-street parking is also available on
the proposed streets.
City of Meridian | Department Report III. Staff Analysis
i. Residential parking analysis
The proposal will be required to meet the standards for parking as set forth in UDC 11-
3C-6.
5. Building Elevations (Comp Plan 2.01.01C, Architectural Standards Manual):
Five (5) conceptual building elevations were submitted for the proposed subdivision as
shown in Exhibit VII.H. Buildings shall be designed with elevations that create interest
through the use of broken planes, windows, and fenestrations that produce a rhythm of
materials and patterns. Design review is not required for single-family detached structures.
However, because the rear and/or sides of homes facing Locust Grove Road will be highly
visible, Staff recommends a DA provision requiring those elevations incorporate articulation
through changes in two or more of the following: modulation (e.g. projections, recesses, step-
backs, pop-outs), bays, banding, porches, balconies, material types, or other integrated
architectural elements to break up monotonous wall planes and roof lines that are visible
from adjacent public streets. Single-story homes are exempt from this requirement.
Comprehensive Plan policy 2.01.01C encourages the applicants to maintain a range of
residential land use designations that allow diverse lot sizes, housing types, and densities.
6. Fencing (UDC 11-3A-6, 11-3A-7):
All fencing constructed on the site is required to comply with the standards listed in UDC 11-
3A-7.
7. Parkways (Comp Plan, UDC 11-3A-17):
Per the UDC the minimum width of parkways planted with Class II trees shall be eight (8)
feet. The width can be measured from the back of curb where there is no likely expansion of
the street section within the right-of-way; the parkway width shall exclude the width of the
sidewalk. Class II trees are the preferred parkway trees.
Comprehensive Plan policy 3.07.01C appropriate landscaping, buffers, and noise mitigation
with new development along transportation corridors (setback, vegetation, low walls, berms,
etc.) is required.
E. Alternative Compliance
The applicant is requesting alternative compliance for Lot 11, Block 1, due to the impacts of
ACHD’s required right-of-way dedication and roadway improvements along Locust Grove Road.
ACHD requires a fifty-foot (50’) right-of-way dedication from the centerline, pavement widening
extending seventeen feet (17’) from the centerline, a three-foot (3’) gravel shoulder, and a ten-
foot (10’) multi-use pathway located 26.5 feet from the centerline adjacent to the site.
Combined with the City’s 25-foot landscape buffer requirement, these improvements
substantially reduce the usable area on Lot 11, Block 1, where an existing home is located. As a
result, the home would be positioned approximately four feet (4’) from the landscape buffer
property line, encroaching into the R-2 zoning district’s required setback. The applicant also
notes that the buffer placement further limits usable driveway space and raises concerns about
access to the home’s northwest-facing garage.
To address these constraints, the applicant proposes reducing the landscape buffer width along the
west side of Lot 11 from twenty-five feet (25’) to twelve and a half feet (12.5’), placing the buffer
within an easement rather than a common lot. The reduced buffer would include enhanced
landscaping to meet the intent of the code, with the landscape architect proposing seven (7)
additional trees to improve visual screening and sound attenuation between the arterial roadway
and the home.
City of Meridian | Department Report III. Staff Analysis
The Director approved the reduction in landscaping buffer only for the area around the driveway
where it encroaches into the buffer. The remaining buffer shall meet the 25-foot requirement.
F. Transportation Analysis
1. Access (Comp Plan 6.01.02B, UDC 11-3A-3, UDC 11-3H-4):
The existing church has two access points via E. Amity Road and one access point via S.
Locust Grove Road. The Conditional Use Permit approved by Ada County required the
applicant to eliminate the northwestern access. Commission and Council should determine
whether or not access should be further restricted or remain as is until future development
occurs on the property. Note: ACHD has not placed any restrictions on the existing access
points.
Access to the proposed preliminary plat is via Locust Grove Road with the existing house
taking access from a new internal roadway in accord with UDC 11-3A-3. The applicant is
also proposing two (2) stub streets – one at the east boundary and one at the south boundary.
2. Multiuse Pathways (UDC 11-3A-5):
Multiuse pathways shall be constructed in accord with the city's comprehensive plan, the
Meridian Pathways Master Plan, the Ada County Highway District Master Street Map and
Roadways to Bikeways Master Plan.
3. Sidewalks (UDC 11-3A-17):
All sidewalks constructed as part of this proposal are required to comply with the standards
listed in UDC 11-3A-17.
4. Subdivision Regulations (UDC 11-6):
i. Dead end streets
No streets or series of streets that ends in a cul-de-sac or a dead end shall be longer than
five hundred (500) feet except as allowed by UDC 11-6C-3.
ii. Block face
UDC 11-6C-3- regulates block lengths for residential subdivisions. Staff has reviewed the
submitted plat for conformance with these regulations. The intent of this section of code
is to ensure block lengths do not exceed 750 ft, although there is the allowance of an
increase in block length to 1,000 feet if a pedestrian connection is provided. In no case
shall a block face exceed one thousand two hundred (1,200) feet, unless waived by the
City Council.
The proposed block lengths do not exceed the maximum length of 750 feet.
G. Services Analysis
1. Pressurized Irrigation (UDC 11-3A-15):
The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water (UDC 11-3B-6). The applicant should be required to use any existing surface
or well water for the primary source. If a surface or well source is not available, a single-
point connection to the culinary water system shall be required. If a single-point connection
is utilized, the developer will be responsible for the payment of assessments for the common
areas prior to prior to receiving development plan approval.
2. Storm Drainage (UDC 11-3A-18):
An adequate drainage system is required in all developments by the City’s adopted
standards, specifications, and ordinances. Design and construction shall follow best
management practices as adopted by the City as outlined in UDC 11-3A-18. Storm drainage
City of Meridian | Department Report IV. City/Agency Comments & Conditions
will be proposed with a future construction application and shall be constructed to City and
ACHD design criteria.
3. Utilities (Comp Plan 3.03.03G, UDC 11-3A-21):
Ensure development is connected to City of Meridian water and sanitary sewer systems and
the extension to and through said developments are constructed in conformance with the City
of Meridian Water and Sewer System Master Plans in effect at the time of development. All
utilities are available to the site. Water main, fire hydrant and water service require a
twenty-foot (20) wide easement that extends ten (10) feet past the end of main, hydrant, or
water meter. No permanent structures, including trees are allowed inside the easement.
Comprehensive Plan policy 3.03.03G requires urban infrastructure be provided for all new
developments, including curb and gutter, sidewalks, water and sewer utilities.
CITY/AGENCY COMMENTS & CONDITIONS
A. Meridian Planning Division
1. A Development Agreement (DA) is required as a provision of annexation of this property.
Prior to approval of the annexation ordinance, a DA shall be entered into between the City of
Meridian, the property owner(s) at the time of annexation ordinance adoption, and the
developer. A final plat will not be accepted until the annexation ordinance and
development agreement are approved by City Council.
Currently, a fee of $303.00 shall be paid by the Applicant to the Planning Division prior to
commencement of the DA. The DA shall be signed by the property owner and returned to the
Planning Division within six (6) months of the City Council granting the annexation. The DA
shall, at minimum, incorporate the following provisions:
Church of Jesus Christ of Latter-day Saints Property (1685 E. Amity Rd.)
a. The existing church property is deemed a nonconforming use and shall be
subject to the standards outlined in UDC 11-1B-3.
b. The existing church shall connect to City water and sewer service within 60 days of it
becoming available and disconnect from private service, as set forth in MCC 9-1-4 and 9-
4-8.
c. Existing accesses to E. Amity Road and S. Locust Grove Road, including cross access to
parcel #S1132223050, shall be evaluated with future development of the property in
accordance with UDC 11-3A-3.
d. The property shall be limited to the operation of the church or place of religious worship,
subject to the specific use standards outlined in UDC 11-4-3-6.
City of Meridian | Department Report IV. City/Agency Comments & Conditions
Solara Estates Subdivision
a. Future development of this site shall be substantially consistent with the
preliminary plat, landscape plan, open space and amenity exhibits, and
conceptual building elevations for the single-family dwellings included in
Section VII and the provisions contained herein.
b. The rear and/or sides of 2-story structures that face Locust Grove Road shall
incorporate articulation through changes in two or more of the following:
modulation (e.g. projections, recesses, step-backs, pop-outs), bays, banding,
porches, balconies, material types, or other integrated architectural elements to
break up monotonous wall planes and roof lines. Single-story structures are
exempt from this requirement.
c. If warranted, the applicant shall construct a 5-foot temporary sidewalk within
the Locust Grove and Amity Road ACHD right-of-way abutting the west and
north side of the church property.
d. No building permits shall be issued prior to the final plat being recorded.
e. The existing homes shall connect to City water and sewer service within 60 days of it
becoming available and disconnect from private service, as set forth in MCC 9-1-4 and 9-
4-8.
2. The Preliminary Plat included in Section VII, dated March 2025, is approved with the
following revisions:
a. All utility easements reflected in the utility plan shall be included on the final plat.
b. Other than the access approved with this application, direct access to S. Locust Grove
Road is prohibited.
3. The Landscape Plan included in Section VII, dated July 30, 2025 shall be revised as follows:
a. Provide fence details for any proposed fences for this development.
b. Provide a details page for the proposed landscape.
c. The director has approved the alternative compliance request. The reduction in the
landscape buffer for Lot 11 shall only be for the area around the driveway. The
remaining buffer shall meet the 25-foot requirement.
4. Prior to signature on the final plat by the City Engineer, the applicant shall submit a public
access easement for the multi-use pathway along S. Locust Grove to the Planning Division
for approval by City Council and subsequent recordation or unless required by ACHD.
5. The applicant shall construct all proposed fencing and/or any fencing required by the UDC,
consistent with the standards as set forth in UDC 11-3A-7 and 11-3A-6B, as applicable.
6. The development shall comply with standards and installation for landscaping as set forth in
UDC 11-3B-5 and maintenance thereof as set forth in UDC 11-3B-13.
7. Pathway and adjoining fencings and landscaping shall be constructed consistent with the
standards as set forth in UDC 11-3A-7A7, 11-3A-8 and 11-3B-12C.
8. The development shall comply with all subdivision design and improvement standards as set
forth in UDC11-6C-3, including but not limited to driveways, easements, blocks, street
buffers, and mailbox placement.
City of Meridian | Department Report IV. City/Agency Comments & Conditions
9. Off-street parking is required to be provided in accord with the standards listed in UDC Table
11-3C-6 for single-family detached dwellings based on the number of bedrooms per unit.
10. The Applicant shall have a maximum of two (2) years to obtain City Engineer’s signature on
a final plat in accord with UDC 11-6B-7.
11. The Applicant shall comply with all conditions of ACHD.
12. Staff’s failure to cite all relevant UDC requirements does not relieve the applicant from
compliance.
13. The existing home on Lot 11, Block 1 shall update its address once a new address is issued
with the recordation of the final plat.
B. Meridian Public Works
Site Specific Conditions of Approval
1. The applicant is proposing to connect to a sewer shed different from the one identified in the
master plan. The City Engineer has reviewed and approved the proposed change. The
applicant is permitted to tie into the existing sewer line on Locust Grove.
2. Approval of the water system is contingent upon obtaining a variance to connect to Pressure
Zone 5 instead of Pressure Zone 4. All conditions and requirements associated with the
variance must be met, subject to approval by the City Engineer. The variance has not yet
been issued. No connection to Pressure Zone 5 may occur until written approval is provided
by the City Engineer.
General Conditions of Approval
1. Applicant shall coordinate water and sewer main size and routing with the Public Works
Department, and execute standard forms of easements for any mains that are required to
provide service outside of a public right-of-way. Minimum cover over sewer mains is three
feet, if cover from top of pipe to sub-grade is less than three feet than alternate materials shall
be used in conformance of City of Meridian Public Works Departments Standard
Specifications.
2. Per Meridian City Code (MCC), the applicant shall be responsible to install sewer and water
mains to and through this development. Applicant may be eligible for a reimbursement
agreement for infrastructure enhancement per MCC 8-6-5.
3. The applicant shall provide easement(s) for all public water/sewer mains outside of public
right of way (include all water services and hydrants). The easement widths shall be 20-feet
wide for a single utility, or 30-feet wide for two. The easements shall not be dedicated via
the plat, but rather dedicated outside the plat process using the City of Meridian’s standard
forms. The easement shall be graphically depicted on the plat for reference purposes. Submit
an executed easement (on the form available from Public Works), a legal description
prepared by an Idaho Licensed Professional Land Surveyor, which must include the area of
the easement (marked EXHIBIT A) and an 81/2” x 11” map with bearings and distances
(marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a
Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this
document. All easements must be submitted, reviewed, and approved prior to development
plan approval.
4. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water (UDC 11-3B-6). The applicant should be required to use any existing surface
or well water for the primary source. If a surface or well source is not available, a single-
point connection to the culinary water system shall be required. If a single-point connection is
City of Meridian | Department Report IV. City/Agency Comments & Conditions
utilized, the developer will be responsible for the payment of assessments for the common
areas prior to prior to receiving development plan approval.
5. All existing structures that are required to be removed shall be prior to signature on the final
plat by the City Engineer. Any structures that are allowed to remain shall be subject to
evaluation and possible reassignment of street addressing to be in compliance with MCC.
6. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be addressed
per UDC 11-3A-6. In performing such work, the applicant shall comply with Idaho Code 42-
1207 and any other applicable law or regulation.
7. Any wells that will not continue to be used must be properly abandoned according to Idaho
Well Construction Standards Rules administered by the Idaho Department of Water
Resources. The Developer’s Engineer shall provide a statement addressing whether there are
any existing wells in the development, and if so, how they will continue to be used, or
provide record of their abandonment.
8. Any existing septic systems within this project shall be removed from service per City
Ordinance Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment
procedures and inspections (208)375-5211.
9. Street signs are to be in place, sanitary sewer and water system shall be approved and
activated, road base approved by the Ada County Highway District and the Final Plat for this
subdivision shall be recorded, prior to applying for building permits.
10. A letter of credit or cash surety in the amount of 110% will be required for all uncompleted
fencing, landscaping, amenities, etc., prior to signature on the final plat.
11. All improvements related to public life, safety and health shall be completed prior to
occupancy of the structures. Where approved by the City Engineer, an owner may post a
performance surety for such improvements in order to obtain City Engineer signature on the
final plat as set forth in UDC 11-5C-3B.
12. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process, prior to the issuance of a plan
approval letter.
13. It shall be the responsibility of the applicant to ensure that all development features comply
with the Americans with Disabilities Act and the Fair Housing Act.
14. Applicant shall be responsible for application and compliance with any Section 404
Permitting that may be required by the Army Corps of Engineers.
15. Developer shall coordinate mailbox locations with the Meridian Post Office.
16. Compaction test results shall be submitted to the Meridian Building Department for all
building pads receiving engineered backfill, where footing would sit atop fill material.
17. The design engineer shall be required to certify that the street centerline elevations are set a
minimum of 3-feet above the highest established peak groundwater elevation. This is to
ensure that the bottom elevation of the crawl spaces of homes is at least 1-foot above.
18. The applicants design engineer shall be responsible for inspection of all irrigation and/or
drainage facility within this project that do not fall under the jurisdiction of an irrigation
district or ACHD. The design engineer shall provide certification that the facilities have been
installed in accordance with the approved design plans. This certification will be required
before a certificate of occupancy is issued for any structures within the project.
City of Meridian | Department Report IV. City/Agency Comments & Conditions
19. At the completion of the project, the applicant shall be responsible to submit record drawings
per the City of Meridian AutoCAD standards. These record drawings must be received and
approved prior to the issuance of a certification of occupancy for any structures within the
project.
20. A street light plan will need to be included in the civil construction plans. Street light plan
requirements are listed in section 6-5 of the Improvement Standards for Street Lighting. A
copy of the standards can be found at
http://www.meridiancity.org/public_works.aspx?id=272.
21. The City of Meridian requires that the owner post to the City a performance surety in the
amount of 125% of the total construction cost for all incomplete sewer, water and reuse
infrastructure prior to final plat signature. This surety will be verified by a line item cost
estimate provided by the owner to the City. The surety can be posted in the form of an
irrevocable letter of credit, cash deposit or bond. Applicant must file an application for surety,
which can be found on the Community Development Department website. Please contact
Land Development Service for more information at 887-2211.
22. The City of Meridian requires that the owner post to the City a warranty surety in the amount
of 20% of the total construction cost for all completed sewer, water and reuse infrastructure
for duration of two years. This surety will be verified by a line item cost estimate provided by
the owner to the City. The surety can be posted in the form of an irrevocable letter of credit,
cash deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service
for more information at 887-2211.
C. Meridian Park’s Department
https://weblink.meridiancity.org/WebLink/browse.aspx?id=392029&dbid=0&repo=MeridianCit
y
D. Irrigation Districts
1. Boise Kuna Irrigation District
https://weblink.meridiancity.org/WebLink/Browse.aspx?id=392029&dbid=0&repo=Meridia
nCity
E. Idaho Department of Environmental Quality (DEQ)
https://weblink.meridiancity.org/WebLink/Browse.aspx?id=392029&dbid=0&repo=MeridianCit
y
F. Ada County Highway District (ACHD)
https://weblink.meridiancity.org/WebLink/browse.aspx?id=392029&dbid=0&repo=MeridianCit
y
G. Ada County Development Services
https://weblink.meridiancity.org/WebLink/browse.aspx?id=392029&dbid=0&repo=MeridianCit
y
H. Idaho Transportation Department (ITD)
https://weblink.meridiancity.org/WebLink/browse.aspx?id=392029&dbid=0&repo=MeridianCit
y
City of Meridian | Department Report V. Findings
FINDINGS
A. Annexation (UDC 11-5B-3E)
Upon recommendation from the commission, the council shall make a full investigation and shall,
at the public hearing, review the application. In order to grant an annexation and/or rezone, the
council shall make the following findings:
1. The map amendment complies with the applicable provisions of the comprehensive plan;
Staff finds annexation of the subject site with an R-8 and R-2 zoning designation will be
consistent with the Comprehensive Plan Low Density Residential FLUM designation if the
applicant complies with the provisions in Section IV. As the designation will be in line with
the large estate surrounding properties in the area.
2. The map amendment complies with the regulations outlined for the proposed district,
specifically the purpose statement;
Staff finds the proposed lot sizes and layout proposed will be consistent with the purpose
statement of the residential districts if the Comprehensive Plan and that housing
opportunities will provide consistency with the Comprehensive Plan for that area.
3. The map amendment shall not be materially detrimental to the public health, safety, and
welfare;
Staff finds that the map amendment will not be detrimental to the public health, safety and
welfare.
4. The map amendment shall not result in an adverse impact upon the delivery of services by
any political subdivision providing public services within the city including, but not limited
to, school districts; and
Staff finds the proposed annexation shall not result in adverse impact of services.
5. The annexation (as applicable) is in the best interest of city.
Staff finds the proposed annexation is in the best interest of the City if the property is
developed in accord with the provisions in Section IV.
B. Alternative Compliance (UDC 11-5B-5E)
In order to grant approval for an alternative compliance application, the Director shall determine
the following:
1. Strict adherence or application of the requirements are not feasible; or
The existing house cannot meet the requirements for the required twenty-five (25) feet
landscape buffer along Locust Grove Road and still access to the garage or meet the required
setback. The Director approved the reduction in landscaping buffer only be for the area
around the driveway where it encroaches into the buffer. The remaining buffer shall meet the
25-foot requirement.
2. The alternative compliance provides an equal or superior means for meeting the
requirements; and
A minor reduction is proposed to allow access to the driveway and enable the home to meet
the required setbacks of the R-2 zoning district, therefore staff finds the alternative provides
an equal means for meeting the landscape buffer requirement.
3. The alternative means will not be materially detrimental to the public welfare or impair the
intended uses and character of surrounding properties.
Staff finds that the proposed alternative means will not be materially detrimental to public
welfare or impair the intended uses and character of surrounding properties.
City of Meridian | Department Report VI. Action
C. Preliminary Plat (UDC-6B-6)
In consideration of a preliminary plat, combined preliminary and final plat, or short plat, the
decision-making body shall make the following findings:
1. The plat is in conformance with the comprehensive plan and is consistent with this unified
development code;
Staff finds the proposed plat is generally in conformance with the UDC if the Applicant
complies with the conditions of approval in Section IV.
2. Public services are available or can be made available ad are adequate to accommodate the
proposed development;
Staff finds public services can be made available to the subject property and will be adequate
to accommodate the proposed development. The sewer is approximately 350 north of Amity
Road. The applicant is proposing to connect to a sewer shed different from the one identified
in the master plan. The City Engineer has reviewed and approved the proposed change. The
applicant is permitted to tie into the existing sewer line on Locust Grove.
3. The plat is in conformance with scheduled public improvements in accord with the city's
capital improvement program;
Staff finds the proposed plat is in substantial conformance with scheduled public
improvements in accord with the City’s Capital Improvement Program.
4. There is public financial capability of supporting services for the proposed development;
Staff finds there is public financial capability of supporting services for the proposed
development.
5. The development will not be detrimental to the public health, safety or general welfare; and
Staff finds the proposed development is not detrimental to the public health, safety, and
general welfare.
6. The development preserves significant natural, scenic or historic features.
There are no significant natural, scenic or historic features within the proposed development
area.
ACTION
A. Staff:
Staff recommends approval of the proposed annexation, preliminary plat and the director has
approved request for alternative compliance per the provisions in Section IV in accord with the
Findings in Section V.
B. Commission:
Pending
C. City Council:
Pending
City of Meridian | Department Report VII. Exhibits
EXHIBITS
A. Project Area Maps
(link to Project Overview)
1. Aerial
2. Zoning Map
City of Meridian | Department Report VII. Exhibits
3. Future Land Use
4. Planned Development Map
City of Meridian | Department Report VII. Exhibits
5. Map Notes
Recent Area Preliminary Plats (within last 5-years): H-2018-0087 H-2019-0119 H-2019-0134
H-2021-0020 H-2021-0062 H-2022-0012 H-2022-0036 H-2024-0007 H-2024-0044
Recent Area Conditional Use Permits (within last 5-years): H-2019-0123 H-2020-0006 H-
2020-0009 H-2020-0030 H-2019-0134 H-2018-0115 H-2020-0057 H-2020-0117 H-2021-
0021 H-2021-0087 H-2021-0086 H-2017-0068 H-2017-0129 H-2020-0056 H-2018-0017 H-
2019-0097 H-2022-0014 H-2022-0036 H-2022-0089 H-2023-0004 H-2023-0047 H-2024-
0014 H-2024-0022 H-2024-0041
City of Meridian | Department Report VII. Exhibits
B. Service Accessibility Report
City of Meridian | Department Report VII. Exhibits
C. Preliminary Plat (date: 7/30/2025)
D. Site Plan (date: 7/30/2025)
City of Meridian | Department Report VII. Exhibits
E. Landscape Plan (date: 8/5/2025)
City of Meridian | Department Report VII. Exhibits
F. Qualified Open Space Exhibit (date: 7/30/2025)
City of Meridian | Department Report VII. Exhibits
G. Amenity Exhibit
City of Meridian | Department Report VII. Exhibits
H. Emergency Vehicle Turnaround Exhibit
City of Meridian | Department Report VII. Exhibits
I. Building Elevations
City of Meridian | Department Report VII. Exhibits
City of Meridian | Department Report VII. Exhibits
City of Meridian | Department Report VII. Exhibits
J. Annexation Legal Description & Exhibit Map
City of Meridian | Department Report VII. Exhibits
City of Meridian | Department Report VII. Exhibits
City of Meridian | Department Report VII. Exhibits
City of Meridian | Department Report VII. Exhibits
K. Preliminary Plat Legal Description & Exhibit Map
City of Meridian | Department Report VII. Exhibits
City of Meridian | Department Report VII. Exhibits
L. Conditional Use Permit Approved by the Ada County Commission Board
City of Meridian | Department Report VIII. Additional Notes & Details for Staff Report
Maps, Tables, and Charts
ADDITIONAL NOTES & DETAILS FOR STAFF REPORT MAPS, TABLES, AND CHARTS
(link to Community Metrics)
A. One-Mile Radius Existing Condition Notes
This data is automatically derived from enterprise application and GIS databases, and exported
dynamically. Date retrieved notes generally reflect data acquired or processed within the last 30-
days. Analysis is based on a one-mile radius from the centroid of the identified parcel. Parcel
based data excludes certain properties and represents land as it exists now. Properties considered
are only those with a total assessed value greater than 0 (i.e. excludes most HOA area, transitional
development, government, and quasi government facilities). The following values also constrain
included property acreage to reduce outliers and non-conforming instances from distorting
averages: R-2 < 5.0; R-4 < 2.0; R-8 < 1.0; R-15 < 0.5; R-40 < 0.25.
Conditional Use Permits and Preliminary plat data likely include duplicate project submittals as
they may be for the same project, approved at different times through multiple application types.
Consider each independently or review prior application approvals. Some approved entitlements,
and particularly older ones, may be constructed.
Decennial population counts and household counts are based on the most recent Decennial
Census. Current population and current household values are COMPASS estimates, usually for
the year previous, and are based on traffic analysis zone boundaries (TAZ’s).
B. Mixed Use Analysis Notes
This data is derived from enterprise application and GIS databases, and exported dynamically.
Data considered for analysis are only those areas overlapping the overall Mixed Use boundary
area. Mixed Use areas across arterial roadways are distinct, separate, and not considered as they
do not meet the mixed use principles in the Comprehensive Plan (e.g. pedestrian safety,
transportation efficiency, etc.). Mixed Use parcel areas may be greater or smaller than the future
land use area designation boundary due parcel size, configuration, right-of-way, and other factors.
Conditional Use Permits and Preliminary plat data likely include duplicate project submittals as
they may be for the same project, approved at different times through multiple application types.
Consider each independently or review prior application approvals.
C. Service Assessment Notes
This data represents existing conditions derived from our enterprise application and GIS database,
exported through dynamic reporting. The system references the most recent available data from
various sources, including sewer main lines, sewer trunksheds, floodplain, fire service areas and
response times, police crime reporting, pathway information, existing and planned transit,
roadway improvements, school and park proximity, and other resources.
The tool provides context for project review, using multiple indicators consistently. Data from
similar topics may vary based on different levels of review.
The overall score is based on weighted criteria (not a ranked order), and the percentile score
compares the parcel to others in the city (higher is better). This tool was developed as a City
Council priority and outcome of the 2019 Comprehensive Plan. Scores, whether high or low, are
just one data point and should not be the sole basis for decisions.
D. ACHD Roadway Infographic Notes
The Ada County Highway District utilizes a number of planning and analysis tools to understand
existing and future roadway conditions.
• Existing Level of service (LOS). LOS indicator is a common metric to consider a
driver’s experience with a letter ranking from A to F. Letter A represents free flow
conditions, and on the other end Level F represents forced flow with stop and go
City of Meridian | Department Report VIII. Additional Notes & Details for Staff Report
Maps, Tables, and Charts
conditions. These conditions usually represent peak hour driver experience. ACHD
considers Level D, stable flow, to be acceptable. The LOS does not represent conditions
for bikes or pedestrians, nor indicate whether improvements: are possible; if there are
acceptable tradeoffs; or if there is a reasonable cost-benefit.
• Integrated Five Year Work Plan (IFYWP). The IFYWP marker (yes/no) indicates
whether the specified roadway is listed in the next 5-years. This work may vary, from
concept design to construction.
• Capital Improvement Plan (CIP). The CIP marker (yes/no) indicates whether the
specified roadway is programmed for improvement in the next 20-years.