Loading...
HomeMy WebLinkAboutC5.00 Water Plan REMOVE EXISTING S U M M E R W O OD SUBDIVISION City of Meridian Water Notes: ' W BLOW-OFF AND \ ii ����� THE W. DAPHNE STREET CONNECT TO EXISTING 1. CONSTRUCTION OF THE WATER SYSTEM SHALL CONFORM TO THE STANDARDS 8-IN WATER MAIN IN THE"IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA LAND - - X - 71X�_' 58.01.08)"AS WELL AS THE STANDARDS AND SPECIFICATIONS REFERRED TO IN . �" I 'PIRR 3"Ph "PI3"PI GENERAL CONSTRUCTION NOTE N0. 1, SHEET C1.00. - GROUP - - �1 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE _ _ d - - -- - - - - - - - WATER MAINS (SANITARY SEWER, STORM DRAIN,AND IRRIGATION) SHALL BE I I A MINIMUM OF TEN (10) FEET.WHERE IT IS NECESSARY FOR A POTABLE WATER LIJ JMAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN �O N / a ac (18) INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE QPQ. I _ a � a CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES o G ��� g w "' FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08)AND SECTION 430.02 1 11 N 0 M� 10 Q w1 OF THE WASTEWATER RULES (IDAPA 58.01.16). 11433 S.F. 2 �P`'� 69�7 S.F. :° 0.26 AC. 0.16 -C 3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND POTABLE - - - _ _ 9 '� WATER SERVICES OR POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX(6) � 12785 S.F. 0.29 AC. FEET.WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL SEPARATION,THE CROSSING SHALL BE CONSTRUCTED IN N I I C900 45°8"ELBOW ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC / / 6-IN -_ g x 6"REDUCER DRINKING WATER SYSTEMS (IDAPA 58.01.08)AND SECTION 430.02 OF THE w w I / - W/THRUST BLOCK I WASTEWATER RULES (IDAPA 58.01.16). / I °° - it 4. PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT CL 1 W2 \ FACILITY(I.E. PAVERS). w " I � � 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONTINUOUS W2 I I 3� WATER SERVICE TO ALL EXISTING WATER USERS AFFECTED BY CONSTRUCTION. IF WATER SERVICE MUST BE INTERRUPTED,THE CONTRACTOR SHALL 12 I I COORDINATE WITH THE PUBLIC WORKS INSPECTOR. w 1 8000 S.F. � I C/) i I I 0.18AC. \ °° i C, Sheet Notes: N - _X_ O° I I \ I W2 8 " 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB&GUTTER,WATER, STORM / 8000 S.F. DRAIN, CHANNEL CROSSINGS, &SEWER ELEVATIONS OR INVERTS PRIOR TO W2 // 0.18 AC. CONSTRUCTION AND NOTIFY ENGINEER WHEN ELEVATIONS OR INVERTS DO I I NOT MATCH PLANS. z 2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN y� 0o I 1 \ APPROPRIATE LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT J LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. HE 659 I I I AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH Cl) 3: 0.15 A I I I °O MIGHT OCCUR BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND � 8000 S.F. I� 1 13 I I ALL UNDERGROUND UTILITIES. � � I I I �� 0.18 AC. � AND S NORMWATER I W W2 I �2 3. ALL ELBOWS AND TEES SHALL HAVE THRUST BLOCKS. O w I I- I i 7 Y Ke notes: COD1 8000 S.F. � o � 16'COM PUBLIC 16'COM PUBLIC m 16'COM PUBLIC 0.18 AC. z W1 POTABLE WATER MAIN CROSSING-SEE WATER NOTE NO. 2 ON THIS SHEET. UTILITIES EASEMENT UTILITIES EASEMENT W V� z UTILITIES EASEMENT U) o0 1 = W2 POTABLE/NON-POTABLE SERVICE CROSSING-SEE WATER NOTE NO. 3 ON CID 1 I I �O° I J I - THIS SHEET. Q I 1 - M m eo `�' I I 1 � = W3 8"C900 CONDUIT FOR PRESSURE IRRIGATION, PLACE REBAR AT BOTHgo z w I 8000 S.F. I `n ENDS FOR LOCATING PURPOSES. SEE PRESSURE IRRIGATION PLANS FOR a LENGTHS. w I 0.18 AC. 1 W2 I w W4 2-IN WATER METER PER CITY OF MERIDIAN DETAIL W4 FOR SECONDARY 71 1 IRRIGATION SOURCE. SEE SHEET C6.01 FOR CONTINUATION AND BACKFLOW CA w 7 I I I 1 W2 1 °C I 6 PREVENTION REQUIREMENTS. a w I I I i 8000 S.F. CD 1 s I I I 0.18 AC. Legend: 19 i 1 w �, � I � I I I � 8��w 8 WATER MAIN (OR AS NOTED) O CA U w I _ ® GATE VALVE � 15 I I 1 IL a 8435 S.F. w 0.19 AC. i W2 I - FIRE HYDRANT PER CITY OF MERIDIAN DETAIL W8 o LU ~ \ I J w CO J I I THRUST BLOCK PER ISPWC SD-403 SAN "- ZD /- \- / / oo \ C� 3/4"WATER SERVICE PER CITY OF MERIDIAN DETAIL W1 = Q 5 9168 S.F. 3/4"DOUBLE WATER SERVICE PER CITY OF MERIDIAN DETAIL W3 � cc w CD W1 V VV 90°8"ELBOW 0.21 AC. Z cfl W/THRUST BLOCK ° 3� w EXISTING WATER MAIN UJ J M �I �' J J o0 1-8"TEE (FLG) W1 W3 W. RIVA CAPRI STREET W1I ® EXISTING GATE VALVE p 2- ATE VALVE FL xM 8 G S ( G J) gW 81111 8 � .. W/THRUST BLOCK ; - 188-LF 8-IN C900 - o ' OW EXISTING WATER MANHOLE & Q m v Wi / r „ 8"SS 8"SS z 811ss PROPOSED SEWER MAIN (SIZE NOTED) cc o pC w � "ww PIRR o w �� W1 / // P PIRR PRESSURE IRRIGATION W1 W2 / GIRR GRAVITY IRRIGATION Revisions 1� IRR ' w m w CL = I � _ IE, w o � I I � w E,4 I � �k O 1 2 3 8434 S.F. 8370 S.F. 8363 S.F. II 1 0.19 AC. 0.19 AC. 0.19 AC. 23495 S.F. w I I I 0.54 AC. I I �1 m rn 1 16'COM PUBLIC � z o f UTILITIES EASEMENT °O k-'� � I J AND STORMWATER z N J I EASEMENT m w ` a ZD a Q �I I �sZpNAL E1V wCD \11 04� �GENSF� G'r�� T F- w W1 I 3��p P� P� �; P� PIRR 3"PIRR a 213 9 _ __ _ 39, 06/03/2025 IRR 1�"GIRR IRR 4 - - - - - -- - - - - - - -- - - „ - - - -- - - �, sj o j8"GIRR 18 GIRR - �1, - - - - - wA 18 GIRR IRR IRR IRR qTE OF 0 ,Z - - - A q i - v \k � 4/ IRR _ _ E KQqAf .1Jl`; I/111 IPA d 4 Project No.: 121130 - OHP OHP -x -X OHP OHP nupp Date of Issuance: 05.08.2025 Project Milestone: CONSTRUCTION DOCUMENTS EG EG EG EG - li EG EG EG EG EG EG W W W EP W W W W_ _W _ W EP W W W EP W17772 S.F.W EP W W EP EP W W W CONNECT TO EXISTING 8-IN WATER 0.41 AC. W-� MAIN. INSTALL 8"TAPPING SLEEVE - - Water Plan AND 8"TAPPING GATE VALVE. W. McMILLAN ROAD Mop Water Plan 0 30' 60' C5mOO 6 E 2 Horizontal Scale: 1" = 30'