HomeMy WebLinkAboutA-4.5 Building 6 Exterior Elevations_Franklin StorageK E Y N O T E S
SPLIT FACE CMU, PER EXT. SPEC.
GROUND FACE CMU, PER EXT. SPEC.
WALL MOUNTED FIRE EXTINGUISHER, SEE
DETAIL 4/A-1.2
VERTICAL METAL PANEL SIDING, PER SPEC.
SIDEWALL/HEAD FLASHING:
MBCI OR APPROVED EQUAL 22 GA. METAL
SIDEWALL FLASHING. COLOR: MATCH METAL
WALL PANELS
PARAPET WALL BEYOND
DOOR JAMB WALL PANEL COLOR TO MATCH
ADJACENT METAL PANEL SIDING.
PARAPET CAP, SEE DETAIL X/A-7.X
RECESSED ARCHITECTURAL GLASS CLADDING,
PER PLAN
METAL DOWNSPOUT, PER EXT. SPEC.
PRE-FINISHED METAL FASCIA, PER EXT. SPEC.
METAL ROOFING PANELS, PER SPEC.
4" WIDE, 24 GA. PRE-FINISHED METAL GUTTER,
CONT. AT LOW EAVES.
ROLL-UP COIL DOOR, PER EXT. SPEC.
DOOR, PER PLAN.
4" METAL TRIM, PER SPEC.
METAL AWNING, PER DETAIL X/A-7.X
PIPE BOLLARD, PER DETAIL 2/A-1.2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
SCALE: 1" = 10'
S O U T H E L E V. - B L D G 6
T.O. SLAB
±0' - 0"
T.O. PARAPET
T.O. PARAPET
18' - 0"±
SCALE: 1" = 10'
E A S T E L E V. - B L D G 6
T.O. SLAB
±0' - 0"
T.O. PARAPET
SCALE: 1" = 10'
W E S T E L E V. - B L D G 6
T.O. SLAB
±0' - 0"
T.O. PARAPET
16' - 8"±
T.O. PARAPET
20' - 0"±
T.O. SLAB
±0' - 0"
SCALE: 1" = 10'
N O R T H E L E V. - B L D G 6
T.O. SLAB
±0' - 0"
T.O. PARAPET
16' - 8"±
T.O. PARAPET
18' - 0"±T.O. PARAPET
20' - 0"±
T.O. PARAPET
16' - 8"±
LOW EAVE
11' - 6"±
LOW EAVE
9' - 6"±
LOW EAVE
9' - 6"±
T.O. PARAPET
20' - 0"±
LOW EAVE
11' - 6"±
HDR. HT.
8' - 0"±
HDR. HT.
8' - 0"±
T.O. PARAPET
14' - 8"±4 M3
20'-0"35'-4 1/2"
TYP.
1 C3
TYP.
1C1
TYP.
2 C2
TYP.
16
TYP.3'-6"11'-2"M2 4
TYP.
35'-4 1/2"20'-0"20'-0"20'-0"35'-4 1/2"14'-11 1/2"20'-0"9'-4"9'-4"1'-4"9'-4"9'-4"1'-4"6'-0"12'-0"1 C3
TYP.
1C1
TYP.
2 C2
TYP.
9
17
9 9 9 9 9 9 9 9 9
M18
TYP.
M18
TYP.
17 17
M24
M3 4
TYP.
TYP.
12 MR1
TYP.
12 MR1
TYP.
10 10 10 10 10
7
TYP.
7
TYP.
7
TYP.
7
TYP.
10 10 1014D1
TYP.
14 D1
TYP.
14 D1
TYP.
159'-4"6'-0"1'-4"9'-4"6'-0"1'-4"6
TYP.
6
TYP.
5
TYP.
5
TYP.
4M2
TYP.
4 M3
TYP.
13 M1
TYP.
11 M1
TYP.
4 M3
TYP.
13 M1
TYP.M18
TYP.
4 M3
TYP.
4M2
TYP.
M18
TYP.
26'-0"21'-5"26'-0"21'-5"26'-0"
4'-0"
6'-0"
20' - 0"±
20' - 0"±
12
1/2 8"8"G E N E R A L N O T E
1.ALL EXTERIOR FRAMED WALLS TO RECEIVE
TYVEK BUILDING WRAP OVER STUDS AND
EXTERIOR SHEATHING WHERE OCCURS. (I.E.
UNDER FINISH SIDING MATERIALS).
2.INSTALL WATER SHIELD PROTECTION/
FLASHING AT ALL OPENINGS. TAPE 4" MIN.
OVER TYVEK AND RETURN INTO OPENINGS IN
WALL
3.ALL DOWN SPOUTS ARE TO MATCH TRIM COLOR,
SEE EXTERIOR FINISH SPECS.
4.FOR EXTERIOR SPECIFICATIONS. SEE SPECS ON
SHEET A-4.0
B.O. AWNING
8' - 8"±8"18 3
18 18
18
3
SCALE: N.T.S.
S I T E K E Y P L A N LANARK ST.FRANKLIN RD.EMERGENCY
ACCESS
ACCESS
DRIVE
BUILDING - 1A
BUILDING - 4
BUILDING - 5
BUILDING - 6
BUILDING - 2
BUILDING - 1B
BUILDING - 3
8'-8"10'-9"9'-8"
4 M3
TYP.
4
4 M2
TYP.
1
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
D
C
B
A
A-4.5DESCRIPTION- COMMENTSDATEDELTAFranklin StorageHATCH DESIGNARCHITECTURE200 W. 36TH ST.BOISE, IDAHO 83714OFFICE: (208) 475-3204FAX: (208) 475-3205THIS PLAN AND/OR DESIGN ARE NOT TO BE CHANGED ORCOPIED IN ANY FORM, NOR ARE THE DOCUMENTS TO BEASSIGNED TO A THIRD PARTY WITHOUT WRITTEN CONSENTAND PROPER COMPENSATION TO HATCH DESIGNARCHITECTURE.THE USE OF THE PLANS SHALL BE RESTRICTED TO THEORIGINAL SITE FOR WHICH THEY WERE PREPARED.DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS,INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BYTHE DESIGNER AND THE DESIGNER'S CONSULTANTS AREINSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECTTO THIS PROJECT. THE DESIGNER AND THE DESIGNER'SCONSULTANTS SHALL BE DEEMED THE AUTHORS ANDOWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICEAND SHALL RETAIN ALL COMMON LAW, STATUTORY ANDOTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS.SHEET TITLE
SHEET NUMBER
SHEETNEW INDUSTRIAL BUILDING FOR:DATE:
JOB NUMBER:19158
JUNE 2025
DRAWN BY:
CHECKED BY:JLH
LACOPYRIGHT 2025HATCH DESIGNARCHITECTURE1DESCRIPTION- COMMENTSDATEDELTA06-26-25CZC/DR PLAN MODBLDG 6
EXTERIOR
ELEVATIONS