HomeMy WebLinkAboutA-4.3 Building 3 Exterior Elevations_Franklin StorageSCALE: 1" = 10'
S O U T H E L E V. - B L D G 3
SCALE: 1" = 10'
E A S T E L E V. - B L D G 3
SCALE: 1" = 10'
W E S T E L E V. - B L D G 3
SCALE: 1" = 10'
N O R T H E L E V. - B L D G 3
T.O. SLAB
±0' - 0"
LOW EAVE
12' - 0"±
T.O. SLAB
±0' - 0"
LOW EAVE
12' - 0"±
T.O. SLAB
±0' - 0"
T.O. SLAB
±0' - 0"
LOW EAVE
12' - 0"±
7
TYP.8 D1
TYP.
4 M1
TYP.
1M3
TYP.
9
1 M3
TYP.
4M1
TYP.
12
1/2
1 M3
TYP.
4M1
TYP.
12
1/2
99
K E Y N O T E S
VERTICAL METAL PANEL SIDING
4" WIDE, 24 GA. PRE-FINISHED METAL GUTTER,
CONT. AT LOW EAVES.
PRE-FINISHED METAL ROOFING PANELS, PER
SPEC.
PRE-FINISHED METAL FASCIA, PER EXT. SPEC.
PIPE BOLLARDS, SEE DETAIL 2/A-1.2
METAL DOWNSPOUT, PER EXT. SPEC.
DOOR JAMB WALL PANEL COLOR TO MATCH
ADJACENT METAL PANEL SIDING.
ROLL-UP COIL DOOR, PER EXT. SPEC.
WALL MOUNTED FIRE EXTINGUISHER, SEE
DETAIL 4/A-1.2
1
2
3
4
5
6
7
8
9
G E N E R A L N O T E
1.ALL EXTERIOR FRAMED WALLS TO RECEIVE
TYVEK BUILDING WRAP OVER STUDS AND
EXTERIOR SHEATHING WHERE OCCURS. (I.E.
UNDER FINISH SIDING MATERIALS).
2.INSTALL WATER SHIELD PROTECTION/
FLASHING AT ALL OPENINGS. TAPE 4" MIN.
OVER TYVEK AND RETURN INTO OPENINGS IN
WALL
3.ALL DOWN SPOUTS ARE TO MATCH TRIM COLOR,
SEE EXTERIOR FINISH SPECS.
4.FOR EXTERIOR SPECIFICATIONS. SEE SPECS ON
SHEET A-4.0
5 55 5 5 5
5 58D1
TYP.7
TYP.
1M3
TYP.
67
TYP.8 D1
TYP.
3 MR1
TYP.
2 M1
TYP.
1M3
TYP.
6 6695 58D1
TYP.7
TYP.
1M3
TYP.
6
1M31M3
HDR. HT.
10' - 0"±
HDR. HT.
10' - 0"±
SCALE: N.T.S.
S I T E K E Y P L A N LANARK ST.FRANKLIN RD.EMERGENCY
ACCESS
ACCESS
DRIVE
BUILDING - 1A
BUILDING - 4
BUILDING - 5
BUILDING - 6
BUILDING - 1B
BUILDING - 2
BUILDING - 3
S Y M B O L L E G E N D
KEYNOTE TAG, SEE KEY NOTES ON THIS SHEET
MATERIAL TAG, SEE EXTERIOR FINISH
SPECIFICATIONS ON SHEET A-4.0
SECTION CALLOUT, SEE SECTIONS ON SHEET
A-5.0 & A-5.1
*
*
X
A-X.X
1
1
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
D
C
B
A
A-4.3DESCRIPTION- COMMENTSDATEDELTAFranklin StorageHATCH DESIGNARCHITECTURE200 W. 36TH ST.BOISE, IDAHO 83714OFFICE: (208) 475-3204FAX: (208) 475-3205THIS PLAN AND/OR DESIGN ARE NOT TO BE CHANGED ORCOPIED IN ANY FORM, NOR ARE THE DOCUMENTS TO BEASSIGNED TO A THIRD PARTY WITHOUT WRITTEN CONSENTAND PROPER COMPENSATION TO HATCH DESIGNARCHITECTURE.THE USE OF THE PLANS SHALL BE RESTRICTED TO THEORIGINAL SITE FOR WHICH THEY WERE PREPARED.DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS,INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BYTHE DESIGNER AND THE DESIGNER'S CONSULTANTS AREINSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECTTO THIS PROJECT. THE DESIGNER AND THE DESIGNER'SCONSULTANTS SHALL BE DEEMED THE AUTHORS ANDOWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICEAND SHALL RETAIN ALL COMMON LAW, STATUTORY ANDOTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS.SHEET TITLE
SHEET NUMBER
SHEETNEW INDUSTRIAL BUILDING FOR:DATE:
JOB NUMBER:19158
JUNE 2025
DRAWN BY:
CHECKED BY:JLH
LACOPYRIGHT 2025HATCH DESIGNARCHITECTURE1DESCRIPTION- COMMENTSDATEDELTA06-26-25CZC/DR PLAN MODBLDG 3
EXTERIOR
ELEVATIONS