HomeMy WebLinkAboutA-4.0 Building 1A Exterior Elevations_Franklin StorageC1: CONCRETE MASONRY UNIT -SPLIT FACE:
CMU SOLID VENEER (4X8X16) w/ INTEGRAL COLOR
& WATER REPELLANT MANUFACTURER: BASALITE OR
APPROVED EQUAL COLOR:
600 SPLIT FACE FINISH
C2: CONCRETE MASONRY UNIT - GROUND FACE:
CMU w/ INTEGRAL COLOR & WATER REPELLANT
MANUFACTURER: BASALITE OR APPROVED EQUAL
COLOR: 825 SAGE
C3: CONCRETE MASONRY UNIT - SPLIT FACE:
CMU w/ INTEGRAL COLOR & WATER REPELLANT
MANUFACTURER: BASALITE OR APPROVED EQUAL
COLOR: 695 CHARCOAL
D1: COIL OVERHEAD GARAGE DOORS
ROLL-UP OVERHEAD GARAGE DOOR, SEE SCHEDULE
ON A-6.0. INSTALL PER MANUF. SPECS.
COLOR: WHITE
M1: METAL FASCIA, TRIM, GUTTER (24 GA.), PARAPET CAP &
DOWNSPOUT
MANUFACTURER: MBCI OR APPROVED EQUAL
PRODUCT/FINISH: PRE-FINISHED COPING CAP,
METAL FASCIA, TRIM, GUTTER & DOWNSPOUT
COLOR: CHARCOAL GRAY
M2: VERTICAL METAL SIDING
MANUFACTURER: MBCI OR APPROVED EQUAL, RRU
26 GA. PRODUCT/FINISH: PRE-FINISH METAL PANEL
COLOR: CHARCOAL GREY
M3: VERTICAL METAL SIDING
MANUFACTURER: MBCI OR APPROVED EQUAL, RRU
26 GA. PRODUCT/FINISH: PRE-FINISH METAL PANEL
COLOR: HUNTER GREEN
MR1: METAL ROOF PANELS
MANUFACTURER: MBCI OR APPROVED EQUAL
PRODUCT/FINISH: PRE-FINISH METAL PANEL
COLOR: CHARCOAL GRAY
SIDEWALL FLASHING
22 GA. SIDEWALL METAL FLASHING TO MATCH
METAL PANEL SIDING AS MANUFACTURED BY MBCI
(OR APPROVED EQUAL) REF: DETAIL X/A-7.X
BUILDING WRAP WEATHER BARRIER
DUPONT TYVEK COMMERCIAL WRAP WEATHER
BARRIER ASSEMBLY FOR VERTICAL BUILDING
ENVELOPE PROTECTION FOR THE ENTIRE FRAMED
PORTION OF THE BUILDING. ASSEMBLY TO INCLUDE
WEATHER BARRIER MEMBRANE, SEAM TAPE,
FLASHING, & FASTENERS.
SCALE: 1" = 10'
S O U T H E L E V. - B L D G 1 A
SCALE: 1" = 10'
E A S T E L E V. - B L D G 1 A
SCALE: 1" = 10'
W E S T E L E V. - B L D G 1 A
T.O. SLAB
±0' - 0"
T.O. PARAPET
14' - 8"±
T.O. PARAPET
12' - 8"±
T.O. SLAB
±0' - 0"
T.O. PARAPET
T.O. PARAPET
18' - 0"±
T.O. PARAPET
12' - 8"±
T.O. PARAPET
14' - 8"±
T.O. SLAB
±0' - 0"
T.O. PARAPET
T.O. PARAPET
18' - 0"±
SCALE: 1" = 10'
N O R T H E L E V. - B L D G 1 A
T.O. SLAB
±0' - 0"
T.O. PARAPET
18' - 0"±T.O. PARAPET
20' - 0"±
T.O. PARAPET
14' - 8"±
HDR. HT.
8' - 0"±LOW EAVE
9' - 6"±
1 C3
1C1
2C2
9'-4"9'-4"1'-4"9
15
9
M18
M3 4
M1 8
M2 4
16
4 M2
M18 M1 8
6'-0"12'-0"4 M3
20'-0"35'-3"
TYP.1 C3
TYP.
1C1
TYP.
2 C2
TYP.
16
TYP.3'-6"9'-2"M2 4
TYP.
34'-9 1/2"34'-10"35'-3 1/2"20'-0"21'-4"20'-0"20'-0"7'-4"6'-0"1'-4"10 10 10 10107
TYP.
7
TYP.14 D1
TYP.
14 D1
TYP.
6
TYP.
6
TYP.
5
TYP.
4 M3
4 M3
TYP.
13 M1
TYP.
1C17'-4"6'-0"1'-4"2C2
1C3
M18
TYP.
M18
TYP.
M18
TYP.
11 M1
12 MR1
TYP.
M18
TYP.
M18
TYP.
4 M2
TYP.
14'-0"6'-5"1'-4"
20' - 0"±
20' - 0"±
K E Y N O T E S
SPLIT FACE CMU, PER EXT. SPEC.
GROUND FACE CMU, PER EXT. SPEC.
WALL MOUNTED FIRE EXTINGUISHER, SEE
DETAIL 4/A-1.2
VERTICAL METAL PANEL SIDING, PER SPEC.
SIDEWALL/HEAD FLASHING:
MBCI OR APPROVED EQUAL 22 GA. METAL
SIDEWALL FLASHING. COLOR: MATCH METAL
WALL PANELS
PARAPET WALL BEYOND
DOOR JAMB WALL PANEL COLOR TO MATCH
ADJACENT METAL PANEL SIDING.
PARAPET CAP, SEE DETAIL X/A-7.X
RECESSED ARCHITECTURAL GLASS CLADDING,
PER PLAN
METAL DOWNSPOUT, PER EXT. SPEC.
PRE-FINISHED METAL FASCIA, PER EXT. SPEC.
METAL ROOFING PANELS, PER SPEC.
4" WIDE, 24 GA. PRE-FINISHED METAL GUTTER,
CONT. AT LOW EAVES.
ROLL-UP COIL DOOR, PER PLAN
METAL AWNING, PER DETAIL X/A-7.X
4" METAL TRIM, PER DETAIL X/A-7.X
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12
1/2B.O. AWNING
8' - 8"±
B.O. AWNING
8' - 8"±
T.O. PARAPET
20' - 0"±
B.O. AWNING
8' - 8"±8"G E N E R A L N O T E
1.ALL EXTERIOR FRAMED WALLS TO RECEIVE
TYVEK BUILDING WRAP OVER STUDS AND
EXTERIOR SHEATHING WHERE OCCURS. (I.E.
UNDER FINISH SIDING MATERIALS).
2.INSTALL WATER SHIELD PROTECTION/
FLASHING AT ALL OPENINGS. TAPE 4" MIN.
OVER TYVEK AND RETURN INTO OPENINGS IN
WALL
3.ALL DOWN SPOUTS ARE TO MATCH TRIM COLOR,
SEE EXTERIOR FINISH SPECS.
4.FOR EXTERIOR SPECIFICATIONS. SEE SPECS ON
SHEET A-4.0
E X T E R I O R F I N I S H S P E C I F I C A T I O N S
3 3
S Y M B O L L E G E N D
KEYNOTE TAG, SEE KEY NOTES ON THIS SHEET
MATERIAL TAG, SEE EXTERIOR FINISH
SPECIFICATIONS ON SHEET A-4.0
SECTION CALLOUT, SEE SECTIONS ON SHEET
A-5.0 & A-5.1
*
*
SCALE: N.T.S.
S I T E K E Y P L A N LANARK ST.FRANKLIN RD.EMERGENCY
ACCESS
ACCESS
DRIVE
BUILDING - 1A
BUILDING - 4
BUILDING - 5
BUILDING - 6
BUILDING - 2
BUILDING - 1B
BUILDING - 3
X
A-X.X
1 1
1
1
1
D
C
B
A
1 2 3 4 5 6
1 2 3 4 5 6
D
C
B
A
A-4.0DESCRIPTION- COMMENTSDATEDELTAFranklin StorageHATCH DESIGNARCHITECTURE200 W. 36TH ST.BOISE, IDAHO 83714OFFICE: (208) 475-3204FAX: (208) 475-3205THIS PLAN AND/OR DESIGN ARE NOT TO BE CHANGED ORCOPIED IN ANY FORM, NOR ARE THE DOCUMENTS TO BEASSIGNED TO A THIRD PARTY WITHOUT WRITTEN CONSENTAND PROPER COMPENSATION TO HATCH DESIGNARCHITECTURE.THE USE OF THE PLANS SHALL BE RESTRICTED TO THEORIGINAL SITE FOR WHICH THEY WERE PREPARED.DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS,INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BYTHE DESIGNER AND THE DESIGNER'S CONSULTANTS AREINSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECTTO THIS PROJECT. THE DESIGNER AND THE DESIGNER'SCONSULTANTS SHALL BE DEEMED THE AUTHORS ANDOWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICEAND SHALL RETAIN ALL COMMON LAW, STATUTORY ANDOTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS.SHEET TITLE
SHEET NUMBER
SHEETNEW INDUSTRIAL BUILDING FOR:DATE:
JOB NUMBER:19158
JUNE 2025
DRAWN BY:
CHECKED BY:JLH
LACOPYRIGHT 2025HATCH DESIGNARCHITECTURE1DESCRIPTION- COMMENTSDATEDELTA06-26-25CZC/DR PLAN MODBLDG. 1A
EXTERIOR
ELEVATIONS