Loading...
HomeMy WebLinkAboutStaff Comments STAFF REPORT: CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT ~. CI"YVt'lI' ~~'/1I' orldi:n .c '\ ID....HO " ~RE -~. JAN 3 1 2007 Hearing Date: February 6, 2007 Transmittal Date: February 1, 2007 TO: Mayor and City Council FROM: Kristy Vigil, Assistant City Planner 'ti Michael Cole, Development Services Coordinator (Y\ C SUBJECT: Southwick Subdivision Final Plat City Of Meridian City Clerk Office Request for Final Plat Approval of Southwick Subdivision Consisting of 26 Single-Family Residential Building Lots and 6 Common Lots on 10.59 Acres in an R-4 Zone by Gemstar Development, LLC (File# FP-06-054). We have reviewed this submittal and offer the following comments and conditions of the applicant. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION The applicant, Gemstar Development, LLC, has applied for [mal plat approval of 26 single-family residential building lots and 6 common lots on 10.59 acres of land for Southwick Subdivision. The current zoning designation for the proposed subdivision is R-4 (Medium Low-Density Residential). The gross density of the proposed subdivision is 3.02 dwelling units per acre and the net density is 4.69 dwelling units per acre. Southwick Subdivision is located east of Linder Road at 1255 W. Ustick Road in the NW 1/4 of T. 3N., R.1 W., Section 1. This property has not been previously platted. The Meridian City Council approved the preliminary plat for Southwick Subdivision on September 12, 2006 and the submitted final plat substantially complies with the approved preliminary plat. Staff recommends approval of Southwick Subdivision with the comments and conditions stated in this report. SITE SPECIFIC CONDITIONS 1. Applicant is to meet all terms of the approved preliminary plat (PP-06-0 18) and annexation and zoning (AZ-06-019). 2. The construction plans do not indicate the source for the required pressurized irrigation system. Per City Code, surface water shall be utilized for the irrigation source. If a pump station is to be located on site then it shall be located in a common lot, outside of any required landscape buffers. 3. The applicant has not indicated who will own the pressurized irrigation system in this development. If it is to be owned by the Homeowner's Association then a draft Operations and Maintenance Manual shall be submitted prior to construction plan approval, with a "final draft" being submitted prior to final plat signature by the City Engineer. If it is to be owned and operated by an irrigation district then a letter of plan approval shall be submitted prior to scheduling of a pre-construction meeting. FP-06-054 Southwick Subdivision FP.doc PAGE 1 CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT 4. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a single-point connection to the potable water system is used, the developer shall be responsible for the payment of assessments for the irrigable common areas prior to signature on the final plat by the Meridian City Engineer. 5. All lots encumbered by the AE flood plain shall receive elevation certification. 6. Staff is uncertain if the Ada County Surveyor will allow the graphically depicted flood plain line to remain on the plat. If it is not allowed, after the recordation of the plat, the applicant shall submit to Public Works at addressing time an entirely separate plat with the flood plain line shown to aid in tracking of lots requiring elevation certification. 7. Prior to construction plan approval the applicant shall submit a "No Rise Analysis" for the crossing of the Creason Lateral. 8. All fencing installed on the site must be in compliance with UDC 11-3A-6 and 11-3A-7. Temporary construction fencing to contain debris shall be installed at the subdivision boundary where permanent fencing does not exist. Perimeter fencing shall be installed prior to release of building permits for this subdivision. 9. The applicant shall be responsible to construct the sewer and water mains to and through this proposed development. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, for any mains that are required to provide service. Minimum cover over sewer mains is three-feet. If there is less than three feet from top of pipe to sub-grade then upgraded pipe materials shall be used per City of Meridian Standard Specifications. 10. The bearings in the second and third call out in the Certificates of Owners do not match what is shown on the plat. The applicant shall ensure the legal description in the Certificate of Owners matches what is depicted on the plat, and that both are accurate. 11. The scales on pages 2 and 3 of the plat are incorrectly labeled. The applicant shall revise the plat so the depicted scale is the actual scale of the drawing shown. 12. The existing house on Lot 3, Block 2 shall be required to connect to City Services. The applicant shall be responsible for the payment of assessments prior to signature on the final plat. The applicant shall be responsible for the actual physical connection to the municipal services prior to Certificates of Occupancy being issued in this subdivision. 13. The plat shows a graphically depicted lO-foot wide gravity irrigation easement along Lots 10, Block 3, and Lot 2, Block 4. However the construction plan shows no facility being installed there. Either revise the construction plans to show the gravity irrigation line that is being installed, OR remove the depicted easement from the face of the plat. 14. Graphically depict an 8-foot wide Public Utilities, Drainage and Irrigation easement along all interior lot lines, where a pressurized irrigation main is being installed. The following lot lines need the extra easement dedicated according to the submitted construction plans, these may change due to redline comments. a.) The south boundary of Lot 3, Block 2. FP-06-054 Southwick Subdivision FP.doc PAGE 2 CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT 15. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4~8. Wells may be used for non-domestic purposes such as landscape irrigation. 16. Please submit a copy of the Ada County Street Name Committee's "Final" letter for the street names and lot & block numbering. Make all corrections necessary to comply. 17. Revise or add the following plat notes on the face of the plat prepared by Idaho Survey Group, and dated 10/16/06: 7.) Include instrument number. 9.) Revise to read, ". . .shall be in compliance with Title 11 and Title the applicable zoninll rellUlations of the City of Meridian at the time ofbuildinll permit submittal." *.) Add note, "Direct lot access to Ustick Road is prohibited." 18. The landscape plan, prepared by The Land Group, and dated 01/24/07 shall be revised as follows: a. Include fencing details for the fencing on the north and west boundaries of Lot 3, Block 2 (i.e. construction materials, & picture/sketch). b. Show and label the Creason Lateral on the plan. c. Depict the required landscaping adjacent to the Creason Lateral on the plan. Submit three full-size copies of the revised landscape plan to the Planning Department prior to signature ofthe.final plat by the City Engineer. 19. All areas approved as open space shall be free of wet ponds or other such nuisances. All stormwater detention facilities incorporated into the approved open space are subject to UDC 11- 3B-11 and shall be fully vegetated with grass and trees. Sand, gravel or other non-vegetated surface materials shall not be used in open space lots, except as permitted under UDC 11-3B- II. Where the applicant has submitted a preliminary landscape plan and where staff has reviewed such plan, the landscaping shall be consistent with the preliminary plan with modifications as proposed by staff. If the stormwater detention facility cannot be incorporated into the approved open space and still meet the standards of UDC 11- 3B-ll, then the applicant shall relocate the facility. This may require losing a developable lot or developable area. It is the responsibility of the developer to comply with ACHD, City of Meridian and all other regulatory requirements at the time of final construction. 20. Staff s failure to cite specific ordinance provisions or conditions of the preliminary plat does not relieve the Applicant of responsibility for compliance. STANDARD CONDITIONS 1. Per UDC 11-3A-6 all irrigation ditches, laterals or canals, exclusive of natural waterways and the Creason Lateral, that intersect, cross or lie within the area being subdivided shall be covered. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department prior to plan approvaL If lateral users association approval can not be obtained, alternate plans will be reviewed and approved by the City Engineer. 2. Street signs are to be in place, water system shall be installed and activated, sewer system shall have passed air-testing and video inspection, fencing installed, drainage lots constructed, road base approved by the Ada County Highway District and the Final Plat for this subdivision shall be recorded, prior to applying for building permits. FP~06-054 Southwick Subdivision FP.doc PAGE 3 CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT 3. A letter of credit or cash surety in the amount of 110% shall be required for all uncompleted fencing, landscaping, amenities, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 4. All development improvements, including but not limited to water, sewer, fencing, micro-paths, pressurized irrigation and landscaping shall be installed and approved prior to obtaining certificates of occupancy. 5. A written certificate of completion shall be prepared by the landscape architect, landscape designer or qualified nurseryman responsible for the landscape plan upon completion of the landscape installation. The Certificate of Completion shall verify that all landscape improvements, including plant materials and sprinkler installation, are in substantial compliance with the approved landscape plan. 6. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat. 7. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 8. Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. 9. Applicant shall be responsible for application and compliance with and NPDES Permitting that may be required by the Environmental Protection Agency. 10. All development features shall comply with the Americans with Disabilities Act and the Fair Housing Act. 11. Any tree over 4" in caliper that is removed from the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. 12. Approval of the preliminary plat shall become null and void if the applicant fails to record the final plat within two years of the approval of the preliminary plat per UDC 11-6B- 7 A. In the event that the development of the preliminary plat is made in successive phases in an orderly and reasonable manner, and conforms substantially to the approved preliminary plat, such segments, if submitted within successive intervals of eighteen months, may be considered for final approval without resubmission for preliminary plat approval per UDC II ~6B-7B. STAFF RECOMMENDATION Staff recommends approval of the final plat for Southwick Subdivision (FP-06-054) with the above stated conditions. FP-06-054 Southwick Subdivision FP.doc PAGE 4