HomeMy WebLinkAboutPZ - Geotech SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC Jim Conger July 4, 2024 Conger Management Group Pagel of 29 4824 West Fairview Avenue File 24722-A Boise, Idaho 83706 Re: Geotechnical Recommendations Report Vicenza North Property North Ten Mile Road Meridian, Idaho Jim: As per your authorization, we have generated this Residential Geotechnical Recommendation report based upon research performed in 2022 for the property owner, Mike McCollum. Mr. McCollum has authorized the use of this information. It is noted that our scope of work as originally authorized was for approximately 48 acres of the 60 acres parcel, consisting of the two large farm fields directly north of the Walmart development. SITE also provided geotechnical engineering for Vicenza Subdivision to the west with test pits that extend onto the west end of subject property. The approximate location of these test pits is shown on the included test pit map. These test pits were similar to those included herein. Based upon our research, observations, and laboratory test results, this report confirms our prior opinion that this site is acceptable for the proposed residential subdivision development. Our research has determined the following: • On site test pits and IDWR well logs for nearby properties indicate that basalt bedrock is not present on the subject property. Onsite soils cut from streets and stormwater facilities can be used as structural fill on building lots and within public right of ways. • Groundwater is shallow on the property and is currently being measured through the end of the 2024 irrigation season. Groundwater is currently six to nine feet below the ground surface. These depths are confirmed by IDWR well logs for two, nearby properties, see Well Logs Los in the Appendix. In 2023 groundwater peaked near the beginning of Septmenber at one to 1.5 feet higher than current measurements. See our separate groundwater report for most current data. a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC • Percolation of stormwater has been addressed in nearby subdivisions with brick pavers, shallow basins, and roadside swales. Prior to testing where stormwater facilities are planned, a design recommendation of P=2 in/hr. with a drain time of less than 12 hours is recommended. These values must be confirmed at the location of injection facilities. Penetrating the cemented silt/sand soils that extend to as deep as eight feet below the surface is critical. Recommendations for construction are included herein. We appreciate this opportunity to be of service. Please contact our office if additional information or services are required. Respectfully submitted, S�aONAL SITE Consulting, LLC � 1STk� �^'® Bob J. Arnold, PE 6345 07106124 N en o. Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC GENERAL On August 9, 2022, SITE personnel logged and sampled twelve test pits on the subject property at the request of the property owner, Mike McCollum. Monitoring wells were installed in anticipation of monitoring the 2023 irrigation season. Locations were limited to the perimeter of the two large farm fields north of the Walmart development. The property was identified in Ada County records as follows: Parcel Parcel # Address Acres 1 SO427417210 North Ten Mile Road 60.0 INVESTIGATION SITE observed the excavation of twelve onsite test pits, excavated by King Construction. Test pit logs and an aerial photo, with approximate test pit locations, are included in the Appendix. Near surface soils consist of sandy, lean clay to average depths of one to two feet but observed as deep as four feet below the surface. This surface soil has been historically cultivated to depths between one and two feet deep and is atop a weakly cemented silt/sand soil. This cemented layer extends to five to eight feet below the surface. At this depth pitrun type sand and gravel was encountered. The top of the sand and gravel layer may also be weakly cemented. The sand and gravels extend to depths greater than our test pits which were halted just below the groundwater surface with caused sloughing of the test pits. RECOMMENDATIONS Site Work Grubbing depths of up to 2 to 6 inches can be anticipated to remove most organic materials. Roots may exist as deep as two feet below the ground surface where large trees and ditches are located or in former alfalfa fields. Therefore, stripping depth is to be adjusted in the field at the time of construction. The cleared subgrade surface should be ripped, watered, and compacted as needed to repair any damage or disturbance of native soils during the clearing and grubbing operation. Proof-rolling of the exposed and repaired subgrade is recommended prior to the placement of structural fill or installation of underground utilities. Excavations caused by demolition, grubbing of ditches, or over excavation of soft or wet areas are to be backfilled with structural fill. All subgrade soils present in the test pits can be used as structural fill on building lots and within right of ways. Blending clay surface soils with onsite silt / sand or imported sand and gravels will improve surface drainage and can reduce moisture content to compactable levels. If encountered, fat clay soil should not be used as structural fill. a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC Compaction of any fill placed within building pads or right of ways must exceed 95% of the maximum dry density as determined by Standard Proctor testing. It should be anticipated that the Meridian City Engineering and / or Building Department will request these test results prior to or at the time of home construction. Structural fill must pass compaction testing and visual inspection for stability. Fill that passes compaction but is observed to rut or deflect under construction traffic is to be rejected. Pavement Sections Based on R-Value test performed on subgrade samples, a pavement section of 2.5"- HMA / 4.0"-3/4" Base / 13.0"-Subbase is appropriate for all subdivision interior streets (TI=6). For subdivision collections (TI=8) a pavement sections of 3.0'74.0'717.0" is recommended. See the R-Value results and pavement section calculations sheets in the Appendix. All materials and methods used in the construction of streets and sidewalks are to comply with ACHD and ISPWC requirements. Residential Foundation System The proposed single-family residential structures may be supported on conventional, continuous, and isolated pad foundations founded upon the native soils or upon structural fill extending to these soils. Based upon proper placement and compaction of structural fill, bearing pressures of up to 1500 psf are allowed for foundations founded on the native soils or upon properly placed and compacted structural fill. Either crawlspaces or slab on grade floors are acceptable. Structural fill placed during lot development must be compacted to meet code and properly support foundations. Unfortunately, structural fill does not percolate stormwater. Therefore, ripping lot surfaces prior to landscaping is recommend to improved yard areas percolation. Slab on Grade Concrete Care must be taken so that all excavations below both interior and exterior slab on grade concrete are properly backfilled in accordance with the structural fill recommendations. Trenches and wall backfill areas are to be filled in lifts and benched each lift so that fill is not placed against a vertical soil face greater than three feet tall. Areas of excessive yielding should be excavated and backfilled with structural fill. Any fill used to increase the elevation of slab on grade concrete should meet the requirement for structural fill. Slab on grade floors, sidewalks and pavements should be placed atop a mat of at least six inches of imported granular structural fill. This depth is to increase to one foot when concrete is to be placed over fat clay soil. This is required to prevent seasonal heaving of sidewalks, patios, and driveways. Mat material should be ISPWC %" crushed base or another approved granular material. a Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC Storm Water It is recommended that storm runoff be directed away from all open excavations and not be allowed to puddle on subgrade soils. As indicated, SITE recommends a design percolation rate of P=2 inches per hour with a drain time of less than 12 hours. This is to be confirmed after the location of stormwater facilities is known or at the time of construction. Site Grading Each completed building lot must be grading and foundation elevations controlled so that site irrigation is retained on each individual lot. Ripping of lot surfaces around completed homes prior to final landscaping may improve percolation of storm and irrigation water. Inspection & Testing A qualified engineer or his representative should monitor fill placement to ensure the work is performed in accordance with these recommendations. For mass filling, field compaction testing shall be performed on each lift of compacted fill for each lot or every 5000 square feet of surface area. Trench backfill and right of ways are to be tested to ACHD / ISPWC requirements. It is noted that structural fill can pass compaction tests and still be unacceptable if pumping, rutting, or deflecting under vehicle or foot traffic. General Comments After the plans and specifications for construction are completed, it is recommended that this consultant be provided with the opportunity to review the final design and specifications. This review will confirm that the earthwork recommendations have been properly interpreted and implemented. At that time, it may be necessary to submit supplementary recommendations. This review is a part of this service and will not result in additional invoicing unless additional research and recommendations are needed. Testing and inspection services are recommended herein. Proper quality control during construction is required to confirm materials and methods and thereby obtain a desirable finished product. Monitoring and testing should also be performed to verify suitability of materials used for structural fills and to confirm proper demolition, subgrade grubbing, subgrade stability, and proper placement and compaction of fills. Any deviations from the herein described subsurface conditions must be brought to the attention of this consultant. This report has been prepared for the exclusive use of the client and their retained design consultants. Findings and recommendations within this report are for specific application to the proposed construction described herein and apply only to the property identified. LO Appendix Follows a Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC APPENDIX Location Aerial Photo Parcel Information & Aerial Photo Aerial Photo with Test Pit Locations Test Pits Logs (12) Soil Log Legend /Abbreviations and Acronyms Adjacent Property Well Logs (2) Pavement Section Calc Sheet (2) R-Value Report (2) a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC LOCATION AERIAL PHOTO IRIS 'IBM, list -wry'. � _ _- •�i*` I i Supplied by Google Earth a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC PARCEL INFORMATION & AERIAL PHOTO weir L Parcel Number: S0427417210 i Information '? Parcel SO427417210 �. — ` Primary Owner BRIDGETOLNER INVESTMENTS LLC Second Owner Property N TEN MILE RD t 3. Address 1 ! r ,r { Total Value $98.100 Subdivision 4N 1',N 27 .377 j. Zoning C-C �1F.rFe�- Acres ITax} 59.966 N Acres 60.019 s x. (Calculated) Legal 1 P.AR#7210 OF SE4 Legal 2 SEC 27 44N 1W w J IandproDATA •• I 1 _ Y vw Supplied by landprodata.com. 00 a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TOPO MAP TV a ` P� A a ® ® L . _ 7d 7— Supplied by Client. Cz a Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC AERIAL PHOTO WITH TEST PIT LOCATIONS C. ok a oWit . 77II .y, -!t s ly�■wf •wws tom.. � ■ ■ •y.rXr� y y ! t ILI Google Earth and Handheld GPS O an o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-1 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-4.0 Brown, Moist, Firm, Blocky, Lean Clay with sand (CL) 3.0 1 1 1 100 1 98 1 93 1 78.6 112.6 1 34 1 14 I 4.0-8.0 Brown/Red, Moist, Firm, Silty, Sand with hardpan (SM) 5.0 100 1 89 1 67 1 51 1 37 1 21 1 27.8 1 19.4 1 N P I N P 1 8.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 9.0' Monitoring Well in Place rl r-1 an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-2 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 #40 I #100 I #200 I %M I LL PI 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-4.0 Brown/Tan, Moist, Firm, Cemented, Silty, Sand with hardpan (SM) 3.0 I 100 1 75 1 48 1 34 1 21 1 16 1 13.2 120.2 1 NP F NP I 4.0-6.0 Brown/Red, Moist, Firm, Cemented, Silty, Sand with hardpan (SM) 5.0 100 1 97 1 96 1 77 64 1 55 1 50.5 1 14.3 1 N P 1 N P 1 6.0-8.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 8.0 Bottom of Excavation @ 8.0' Ground Water Encountered @ 8.0' Monitoring Well in Place N r-1 an o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-3 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-3.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan (SM) R-Value R=9 2.0 100 1 95 1 78 1 64 1 44 1 36 1 30.7 I 14.7 1 N P I N P I 3.0-5.0 Brown/Red, Moist, Firm, Sand & Silt 5.0-9.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 9.0 Bottom of Excavation @ 9.0' Ground Water Encountered @ 8.0' Monitoring Well in Place M r-1 an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-4 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-4.0 Brown/Red, Moist, Firm, Sand, Silt, Hardpan 4.0-6.0 Brown/Tan, Moist, Firm, Cemented, Sand & Silt 6.0-10.0 Brown/Tan, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 9.0' Monitoring Well in Place d" r-1 a an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-5 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-4.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan (SM) 3.0 I 100 1 921 1 70 1 49 1 31 1 22 1 17.3 122.2 1 N P F NP I 4.0-7.0 Brown/Red, Moist, Firm, cemented, Sand, Gravel, Silt 7.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 9.0' Monitoring Well in Place LIB r-1 a an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-6 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-2.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 2.0-7.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan 7.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 9.0' Monitoring Well in Place r-1 an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-7 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-2.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 2.0-8.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan 5.0 I 100 1 97 1 81 1 63 1 40 1 218 1 22.8 120.7 1 NP F NP I 8.0-11.0 Brown/Red, Wet, Firm, Silt, Sand, Gravel 11.0 Bottom of Excavation @ 11.0' Ground Water Encountered @ 10.0' Monitoring Well in Place ILI- r-1 a TEST PIT LOG a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC Test Pit: TP-8 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION I (feet) I 3/4" I 1/2" I 3/8" I #4 I # 10 I #40 I #100 I #200 i 7-T ILLI PI I 0.0-2.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 2.0-6.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan 6.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 10.0' Monitoring Well in Place 00 r-1 a an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-9 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) 3/4" I 1/2" I 3/8" #4 I # 10 I #40 I #100 I #200 I %M I LL PI 0.0-2.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 2.0-4.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan R-Value R=9 3.0 & "R" I I 100 1 98 1 93 1 79 1 66 1 588 I 14.8 1 34 1 7 I 4.0-6.0 Brown/Tan, Moist, Firm, Cemented, Sand & Silt 6.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 10.0' Monitoring Well in Place r-1 a an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-10 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) I 3/4" I 1/2" I 3/8" #4 I # 10 I #40 #100 #200 I %M ILL PI I 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-8.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan 8.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 10.0' Monitoring Well in Place O N an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-11 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) I 3/4" I 1/2" I 3/8" #4 I # 10 I #40 #100 #200 I %M ILL PI I 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-8.0 Brown/Tan, Moist, Firm, Silty, Sand with hardpan 3.0 1 100 1 97 1 84 1 59 1 33 1 24 119.2 128.9 I N P I N P 8.0-10.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 10.0 Bottom of Excavation @ 10.0' Ground Water Encountered @ 10.0' Monitoring Well in Place rl N an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-12 File #: 24722-A Client: Conger Group Date Excavated: 08/09/2022 Project: Vicenza North Excavated By: King Excavation Location: See Aerial Photo Logged By: J. Meusch-SITE DEPTH SOILS DESCRIPTION (feet) I 3/4" I 1/2" I 3/8" #4 I # 10 I #40 #100 #200 I %M ILL PI I 0.0-1.0 Brown, Dry, Firm, Sand & Clay—Cultivated Depth 1.0-8.0 Brown/Red, Moist, Firm, Sand, Gravel, Silt 3.0 1 1 1 1 1 1I I I I 8.0-11.0 Brown/Red, Wet, Firm, Sand, Gravel, Cobble 11.0 Bottom of Excavation @ 11.0' Ground Water Encountered @ 10.0' Monitoring Well in Place N N an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC SOIL LOG LEGEND UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM STANDARD TEST METHOD D 2487 FOR CLASSIFICATION OF SOIL FOR ENGINEERING PURPOSES MAJOR DIVISIONS TYPICAL DESCRIPTIONS GRAVEL& <5% #200 =1 Well-graded gravel, ravel-sand mixture, little or no fines. GRAVELLY GP Poorlygraded gravel,gravel sand mixture,little or no fines COARSE SOILS 5-12%4200 GM FS7ilt—yg ravel, ravel-sand-silt mixtures GRAINED <50%-#4 >12% #200 GC Clayey ravel,gravel-sand-clay mixtures SOILS SAND& <5% #200 SW Well-graded sand,gravelly sand, little or no fines. <50%-#200 SANDY =FP_O0_r1y graded sand,gravelly sand, little or no fines SOILS >12% #200 SM Silty sand,sand-silt mixtures >50%-#4 SC Clayey sand,sand-clay mixtures SILTS& INORGANIC F91 Inorganic silt and very fine sand, rock flour,silty or clayey fine sand or clayey silt with slight plasticity FINE CLAYS CL Lean clay-low to medium plasticity,gravelly,sandy,or silty clay GRAINED LL<50% ORGANIC OL Organic silt and organic silty clay of low plasticity SOILS SILTS& INORGANIC MH Elastic silt, micaceous or diatomaceous fine sand or silt soil. >50%-#200 CLAYS CH Fat clay-high plasticity LL>50% ORGANIC OH Or anic clay-med.or high plasticity:organic silt HIGHLY ORGANIC SOILS PT Peat,humus,swamp soil with high organic content ABBREVIATIONS AND ACRONYMS ASTM American Society for Testing and Materials IBC International Building Code ISPWC Idaho Standard for Public Works Construction IDWR Idaho Department of Water Resources ITD Idaho Transportation Department NP Non-Plastic PCC Portland Cement Concrete TP Test Pit USCS Unified Soil Classification System pcf Pounds per Cubic Foot psf Pounds per Square Foot tsf Tons per Square Foot sf/f Pounds per Square Foot / Foot M N en Cz o. Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC ADJACENT WELL LOG Walmart Property - South of Property IDAH L." DEPARTMENT OF WATER RE OURGES WELL DRILLER'S REPORT WILL TAG ik1 LdR 4520 12MAIM-YVATERLEVELoralWELLYEYT9= -DWW,-Permit W' Q Deplh im4 wuler enoarterad{hI 9.5 SLabcwualer k M{hp +r+Ne-ngM ar i+" m-uLr P k1kftr 7!r (°F] 57 B3=n hole ien-p�r°�I owrlER; 13.ccrlla.,corac y mon wo Cal) Mll-Mart 51nres.Inc. 1t1'M LU4+17 ioy4 meLhad: AdUMF 20D 1 SE 1 M 5t. ow.un�u.+u �' aroavi r,P er. A. rra-++o Unionville A 72710 =0 ca sLm■ ap� a.5 7 GPM 11 0 Mr). M ❑ ❑ ❑ �P 4 NMh0 or Said+❑ F44a 1 EsuLl qr YJnsIO 1Yaiarq.tiNynrteresnrar m2! 27 1A SE 1f4$E IM 13,LITHDLOGIC LOU anger r9pipirg gr4zWFu0 rlm4M= -M-Fr ObL r..mtT. oy..�nro�wr Q a..w or�.r"or r14w,Ads OLF .Wrdcnrnr4x.wwr� y 11 10' oaL � I]p.mdavrrr.rWq 10' 3' nCay o� a $.Q4 �o.rnow.r.v,r�i 1 E V2'J X mssurY r aMu 800'ftW NVV CUt Or-OF N.Taft Mlle - ad McMillan RaaG meridian [i. elk Sub.Na'M - UI3E' mm mik 0 Yuriawl O'r8riKf ❑116poo ❑YTp'mp1 ❑lepw On TYPIE OF Y"K. 14—W@H la1P.O.,rd-iLYI ❑ ry—iWwell dRJLL PdF7HOEI! -�r katin ❑Mud kuury 0 Cable Mother SEALING PROGROUIRES: xwniiwd lc-Ml Talk w Bent or a' P.5 bags , BorehbJe •C,391�1¢'LLINELZ anevr nvnly T�Ir4 rar.r —M U—n..d.a -A-.kW Gil SC)R17 El ❑ ❑ ❑ 'krsrinse ahm ueedi U Y ®a shoe bew"sl 1.PERFORATION9kS UENSr RCES Arorlorrh QY Igw kVPX" V&StV 4RFSUrr4 oniAVJjYW WW]jfl Y Q ru Type Ceri-lok elhad al inrWLalon 80 yoth rf*ln line Lth aurawrnn4 °`" Ylan+u.5 fi.5 2U 6" PVC FR17 Dm Aug21.201$ Line otAug 22.2013 L"Wgftfd+ri�'H'r.+�'�x0IC*140ut74dz-s bda+tieneoar ndYAMal ar Hoadp pe lir pr TRIV" h?H"we ry-g reeyyr{rJ e"p'T ®a ryas fi&Vwly Worm!Adarnsw Pump-&Drilling Co No 457 O.FILTERPACK: �nrropal P416Aug F8,2013 Fur Mrxrr From Oil ToIµ Qi1M1rIaQa'} Plau"wr—M4 8-12 Sand 23.5 5' 31 bags 11-T Overbore �r� - I�A��9,�413 Opergl uaLe&g N.2013 1.FLQVMIJ ARTC53AN= a ermor I D=Fk7m y q+4teMill Q Y 10 N Arleemn Pinmra{PSIGJ aWuftm d Prinapol arllkrand r rm1a rarad V � � - N rce crnlyd dour _ d) ca a Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC ADJACENT WELL LOG East of Property, East of McMillan LOG MW JE?oIU OF TIJE u AL 2j - • STATE BECLOUUMN E COnEm 0 *MNPW 034742 Add.a r C. -rd., d J, N44 tis I1!'A Will Faord *w94 UY■ Sow aF ydl4r rir l SF� { i �— $I.r j■plk in■Irrrdlqq —al■r Iran• If.■iraucd "up. On -Rwnp•Ip 'mV' d■II+■n• "oL i�i A p.l- +r C f3. 0ra-v9 n -Pow f-'� F. t LIl..I pYmp aqd Pa*i w.{■d IS n 64 swr a4i cdbt% L r`L WwSrh a1 Mmr d Pm IF r4wlrrw -RAI. pI., n. LRI. K----*P.pk OHM 0 14m, +4 F++■■H� — r n.winq wdM,d■■cAb-W cants w.,i _ -- ���� Lirrs up- OF YiLM�1•I we4w kib 61 L•rrJ Fa . 71fNEkm alai*Mr IY�F,M�� TLIrLnblL*I n■L■g {a�L■' �4�41 -- } + N11 irRfIL rr-+ih RL.I b kmm I■r,I■nprh and Wcumn tl calm �Ity Ir'�7L••I o•• a8��um o� iW■�i!W a4'r�PF FMIM PrQI C1a11M IJ` wr CASING 1EC010 dlrrL 1Gv■r ii riMly IqY l� L-jY6 Rrenmk-6` 11--HmiR .Ic. v�x1 ■Ic■ aF - z4•��,■.I.Fran wuk d ba&i vl cumm■r:ow rr1 aF w•l If al omplimIm of 4 N en o. Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC DESIGN SECTION CALCULATIONS (ACHD R-Value Method) Project: Vicenza North Property File No.: 24722-A Ten Mile Road - Meridian, Idaho Calc By: BA Client: Conger Group Date: 07/04/24 Design Thickness Equation: T = 0.0032 (TI) (100-R)(12) = GE (inches) T= Design Thickness TI = Traffic Index = 6 By Agency GE = Gravel Equivalent R = R-Value = 9 By Soils Test GE= 21.5 Inches ACHD HMA, 3/4" Base and Aggregate Subbase Actual Thickness Equivalent Thickness HMA Thickness = 2.5 Inches HMA= 5.0 Inches 3/4" Base Thickness = 4.0 Inches RBE= 4.4 Inches Calculated Aggregate Subbase Thickness Equation: Subbase Thickness=SB=GE-HMA-RBE SB= 12.1 Inches CALCULATED DESIGN SECTION HMA= 2.5 inches 3/4" Base = 4.0 inches Subbase = 13.0 inches RECOMMENDED DESIGN SECTION HMA = 2.5 inches 3/4" BASE = 4.0 inches SUBBASE = 13.0 inches N an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC DESIGN SECTION CALCULATIONS (ACHD R-Value Method) Project: Vicenza North Property File No.: 24722-A Ten Mile Road - Meridian, Idaho Calc By: BA Client: Conger Group Date: 07/04/24 Design Thickness Equation: T = 0.0032 (TI) (100-R)(12) = GE (inches) T= Design Thickness TI = Traffic Index = 8 By Agency GE = Gravel Equivalent R = R-Value = 9 By Soils Test GE= 28.5 Inches ACHD HMA, 3/4" Base and Aggregate Subbase Actual Thickness Equivalent Thickness HMA Thickness = 3.0 Inches HMA= 7.5 Inches 3/4" Base Thickness = 4.0 Inches RBE= 4.4 Inches Calculated Aggregate Subbase Thickness Equation: Subbase Thickness=SB=GE-HMA-RBE SB= 16.6 Inches CALCULATED DESIGN SECTION HMA= 3.0 inches 3/4" Base = 4.0 inches Subbase = 17.0 inches RECOMMENDED DESIGN SECTION HMA = 3.0 inches 3/4" BASE = 4.0 inches SUBBASE = 17.0 inches N an a o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC Pavement Engineoring Inc. 19-vaVr'y•Seeremenry+San L40�Guaiuu zo- G`*Rowd-SmI r C&Mm RESISTANC E M) VALLIE TEST ASTM : 2644 Laboratory No.: L222863 Project No.: 220021 Sample Date; nfa Report Date: September 22, 2022 Client: Site Consulting LLC Project Name: Bridge Tower LLC Sample Description: Brown Silty Clay Sample Location: TP-3 100 90 00 70 2 60 50 40 0 0) 0 10 600 700 600 500 400 300 200 100 0 Exudation Pressure (P. ,I,) Resistance Value Test —:30,u, P..S.I. Specimen No_ 1 2 3 4loisture Content 2d.5 19.3 21.7 Dry dens PCF 1d2.8 102.2 100.7 Resistance Value(R) 19 1 Exudation Pressure(PSI) 2 411 126 Expansion Pressure 1 48 1 9= As Received Moisture Content(9 ) 1 20.5 RESISTANCE VALUE AT 300 P.S.I. 9 Reviewed By Brandon Rodebaugh ,'fr.iliv 111: Materials Engineer S*rv;ngr Caf lomm srctca 1987 00 N on o.. Geotechnical Services/So#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 siteconsultingllc.com - 208-440-6276 CONSULTING, LLC Pav€rnant Engrrraaring Inc. Rw�$h'np J�E'i�fl+MfltV-��n Ux}4Ur�w COAGp'a'S!!!f#CYaFII� RESISTANCE (R) VALUE TEST ASTM D 2844 Laboratory No.: L222863 Project No.: 220021 Sample Date: n,a Report date: September22. 2022 Client: Site Consulting LLC Project Name: Bridge Tower LLC Sample Description: Drown Silty Clay Sample Location: TP-9 100 90 70 2 60 50 1 cn 20 10 0 600 700 600 500 400 300 200 100 0 Exudation Pressure (P. .I.) Resistance Value Test —300 P.S.I. Specimen No_ 1 2 3 Moisture Content(%1 18.1 19.3 20.2 Dry Density(PCF) 104.6 103.7 103.2 Resistance Value(R i 1 d S 1 Exudation Pressure;PSI) 313, 2-5 121 Expansion Pressure F,s Received Moisture Content{%) 18.1 RESISTANCE VALUE AT 300 P.S.I. 9 Reviewed D}r Brandon Rodebaugh �1 Materials Engineer Sarv;r�q Caf�hxrra�a srcvc�?�8J ON N a) Nothing Follows a Geotechnica/Services/Soil Testing&Inspection Services