LUMEE RFM RoadFocus RFM RoadFocus N
RoadFocus
by LED Cobra head (medium) LED Cobra head (medium) U) L
CobraRFM O
3000K LED Lumen values Predicted Lumen Depreciation Data
Type R2M Type R2S Type R3M Type R3S Type Type 5 Predicted performance derived from LED manufacturer's data and engineering design estimates,based on IESNA LM-80 methodology.Actual experience may vary due to field application conditions.
Color Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG L70 is the predicted time when LED performance depreciates to 70%of initial lumen output.Calculated per IESNA TM21-11 Addendum B.Published L70 hours limited to 6 times actual LED test hours. '
Project: Ordering Code Temp. Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating , r ,• r r r r V
Lumec RoadFocus LED cobra head luminaires feature a sleek design that Location: RFM-130W32LED 3000 1 25°C >60,000hours >97.6%
provides seamless replacement of existing HID luminaires. RoadFocus Cat.No: RFM-135W40LED 3000 14,254 106 B3-UO-G3 14,944 Ill B3-UO-G2 14,311 106 B3-UO-G2 14,503 107 B2-UO-G2 14,243 106 B2-UO-G3 14,815 110 B4-UO-G2 LED Wattage values
is available in three sizes,offers multiple lumen packages,and a complete
RFM-55W48LED 3000 7,268 132 B2-U0-GI 7,620 138 B2-U. 137
Type: RFM-80W48LED 3000 10,422 129 B2-UO-G2 10,926 136 82-UO-G2 10,463 130 B2-UO-G2 10,603 132 B2-UO-G2 10,414 129 B2-UO-G2 10,832 134 B4-UO-G2
array of optical distributions, making it an outstanding solution for all types Light Engine
RFM-108W48LED 300 13,792 1 124 Ordering Code Total LEDs Configuration Average System Watts" Wattage label"
Of roadway applications. Includes Service Tag, innovative way to provide CONTRACTOR TO VERIFY VOLTAGE RFM 160W48LED 3000 18,211 113 63 UO G3 19,092 119 83 UO G2 18,283 114 B3 UO G3 18,528 115 B2 UO G3 18.197 113 63 UO G3 18,928 118 B4-UO-G2 RFM-130W32LEDow 2x16LED
assistance throughout the life of the product. WITH BUILDING MEP PRIOR TO RFM-SOW60LED 3000 7,643 146 B2-UO-G2 N/A N/A N/A 711,111,684 147 B2 UO-G2 N/A N/A N/A N/A RFM-135W40LED 40 2xl2LED+lxl6LED 135 140
PURCHASE AND INSTALLATION RFM-75W60LED 3000 10,439 136 B2-UO-G2 N/A N/A N/A 10,495 136 132-UO-G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A RFM-55W48LED
Ordering guide RFM-10OW60LED 3000 12,945 131 B3-UO-G2 N/A N/A N/A 13,015 131 B3-UO-G2 N/A N/A N/A RFM-SOW48LED 48 3x16LED 81 80 '
example:RFM-108W41LED3K-G2-R2M-UNV-DMG-HS-PH8-RCD7-GY3 V
RFM-120W60LED 3000 15,302 125 B3-UO-G3 N/A N/A N/A 15,384 126 133-UO-G3 N/A N/A N/A N/A N/A N/A N/A N/A N/A
LED RFM-15OW60LED 3000 18,139 122 B3-UO-G3 N/A N/A N/A 18,237 122 1 B3-UO-G3 N/A N/A N/A I N/ N/A N/A N/A N/A N/A RFM-160W48LED13 48 3xl6LED 161 160
Series
RFM module CCT� Generation Distribution Voltage C trots Options Flrlls�h RFM 170W60LED 3000 20,002 118 133-UO-G3 N/A N/A N/A 20,110 118 133 UO G3 N/A N/A N/A N/A I N/A N/A N/A N/A N/A RFM- W60LED 60 3x20L 52 J
I�u'-ll RFM-7575W60LED 60 3x20LED 77 80
0 99 1
RFM 130W32LED K Type 2 NV 120-277V D4115 Zha a-D4i 2C Two clam with 4 bolts BK Black RFM-12OW60LED 60 3x2OLED 122 120
RoadFocus 135W440LED14 3® eneration 2 R2S pe II VU 347-480V certified API Factory installed NEMA label, BR Bronze 2700K LED Lumen values
medium 55W48LED12 2.7V 2700K short DALI1 Digitally ANSI C136.15-2015 compliant GY3 Gray Type Type Type Type Type Type
ASYM addressable FAWS7 Field adjustable Yp Yp yP Vp Vp Yp RFM-170W60LED10 60 3x20LED 170 170
80W48LED I WH White
108W48LED R2M Type II lighting wattage selector Color Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG
160W48LED Medium interface CSSz•15 Cul-de-Sac Shield Ordering Code Temp. Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating 16.Typical values,rounded.
SOW60LED1° (ASYM) DMGS 0-10V FSSz•16 Front Side Shield =ffUO G2 1 104 B3 UO G2 109 109 17.As per ANSI C136.15-2015.Consult factory for other labeling needs.
75W60LED14 Type 3 SRD' Sensor HS z•15 House Side Shield 18.Rated for+40`C/+104'F.
10OW60LED14 R3S Type III ready driver, LSS 2,15 Left Side Shield RFM-135W40LED 2700 12,800 95 133-UO-G2 13,419 99 B3-UO-G2 12,851 95 B3-UO-G2 13,023 96 B2-U0-G2 12,790 95 B2-UO-G3 13,304 99 B4-UO-G2
120W60LED14 short standard RSS z•'s Right Side Shield ,5 121 B2-UO-GI 6,988 127 297 132 B2-U0-G1 6,781 132 Bt-UO-G2 6,660 121 B1-U0-G2 6,928 126
(ASYM) configuration e
15OW60LED11 NRC No receptacle
id R3M Type III SRD1 Sensor NYBC 4-position terminal block RFM-80W48LED 2700 9,557 119 62-UO-G2 10,019 124 B2-UO-G2 10,560 131 B2-UO-G2 9,723 131 B2-U0-G2 9,550 119 32-UO-G2 9,933 123 B4-UO-G2
170W60LED Medium ready driver, 1 ,208 125 B3-UO-G2 12,274 125 82-U0-G2 12,055 114 B2-U0-G2 12,539
(ASYM) alternate OMS Outdoor Multisensor
Type4 configuration PH81•10 Twist-lock photoelectric ce11, RFM-160W48LED 2700 16,700 104 B3-UO-G3 17,508 109 B3-UO-G2 18,283 114 33-U0-G3 16,991 114 B2-UO-G3 16,687 104 B3-UO-G3 17,357 108 B4-UO-G2 4000K LED Lumen values
4 T e IV UNV(120-277VAC)
(ASYM) PH8/34710•19 Twist-lock photoelectric cell 134 B2-U0-G1 N/A N/A N/A N/A Type R2M Type R2S Type R3M Type R3S Type 4 Type 5
Type 5 (347VAC) RFM-75W60LED 2700 9,538 124 B2-UO-G2 N/A N/A N/A 9,589 125 B2-UO-G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A Color Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG Lumen Efficacy BUG
PH8/480101 Twist-lock photoelectric cell
5 Type V P N/A N/A Orderin Code Temp. Out (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating Output (LPW) Rating
(SYMM) (480VAC)
PHXL 1•10 Twist-lock photoelectric cell, RFM-120W60LED 2700 13,982 115 B3-UO-G3 N/A N/A N/A 14,057 115 B3-U0-G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A RFM-130W32LED 4 321 63-U - , 115 B
extended life,UNV RFM 135W40LED 4000 15,066 112 B3-UO-G3 15,794 117 B3-UO-G2 15,125 112 B3-UO-G2 15,328 114 62-UO-G3 15,054 112 B2-UO-G3 15,659 116 64-UO-G2
(120-277VAC) N/A N- o
PH910 Shorting cap RFM-17OW60LED 2700 18,276 108 B3 UO G3 N/A N/A N/A 18,374 108 63-U0-G3 N/A N/A N/A N/A N/A N/A N/A N/A N/A RFM-55W48LED 40 147 B2- B
RCD'' Tool less receptacle for twist- RFM-8OW48LED 4000 11,10 1138 B2-U0-G2 11,647 145 32-UO-G2 11,153 138 B2-UO-G2 11,302 140 B2-UO-G2 11,101 138 B2-UO-G2 11,546 143 B4-UO-G2 Q �f
lock photocell or shorting cap, _ <
5-pin(optional) RFM-108W48LED 4000 4,702 139 83-UO-G2 14,079 133 B 135 B 132 B2-UO-G2 14,576 138 0
Actual performance may vary due to installation variables including optics,mounting/ceiling height,dirt depreciation,light loss factor,etc.;highly recommended
RCD73.5 Tool less receptacle for twist- to confirm performance with a layout-contact Applications at signify.com/outdoorluminaires. Consult DLC OPL to confirm your specific fixture selection is DLC approved. RFM 160W48LED 4000 19,412 121 B3-UO-G3 20,351 127 B3 UO G2 19.489 121 B3 UO-G3 19,750 123 62 UO-G3 19,397 121 B3 UO G3 20,176 126 64 UO-G2 Q -
lock photocell or shorting cap, 5 _
x 7-pin(standard) Note:Some data may be scaled based on tests of similar but not identical luminaries. M-50W60LED 4 N/A N/A 8,0 N/A N/A - Z N SP2 20kV/10kA Surge protector
•v Z TLRSRS SR receptacle CONTRACTOR TO RFM-75W60LED 4000 10,979 143 B2-UO-G2 N/A N/A N/A 11,038 143 B2-UO-G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A
D a- BAC 1s Meets the requirements of N/A N/A 13,68 N/A
W a UJ the Buy American Act of1933 VERIFY FINISH WITH RFM-120W60LED 4000 16,094 132 B3-UO-G3 N/A N/A N/A 16,181 133 B3-UO-G3 N/A N/A N/A N/A N/A N/A N/A N/A N/A , z 0
¢ (BAA) BUILDING O -
SC Q r RFM-150W60LED,. ./A N/A
Not available with HVU. 3 Not available with PH8,PH8/347,PH8/480,PHXL,PH9, 17 TLRSR and D41 must be selected with OMS ARCHITECT PRIOR V LL
F z Refer to Accessories section to confirm DALI,SRD or SRD1 Driver Options. 3 Failure to properly select the"BAC"suffix could result in RFM 170W60LED 4000 21,037 124 83 UO G3 N/A N/A N/A 21,150 124 B3 UO G3 N/A N/A N/A N/A N/A N/A N/A N/A N/A W
° =Q compatibility of shields with optical distribution a Not available with SRD Driver Options. you receiving product that is not BAA compliant product TO PURCHASE AND C
U O 3 Use of photoelectric cell or shorting cap is 10 Either RCD or RCD7 must be selected with no recourse for an RMA or refund.This BAC desig- Actual performance may vary due to installation variables including optics,mounting/ceiling/ceilin height,dirt depreciation,light loss factor,etc.;highly recommended G
z P Y Y 9 P 9 9 9 p 9 9 YUj
° =Q required to ensure proper illumination. for this option. nation hereunder does not address(i)the applicability INSTALLATION to confirm performance with a layout-contact Applications at signify.com/outdoorluminaires. Consult DLC OPL to confirm your specific fixture selection is DLC approved.
a 4 Select either DALI or DMG or SRD or SRD1 11 Extended lead-time may apply. of,or availability of a waiver under,the Trade Agree-
Y PP Y ments Act,or a the"Buy America"domestic content Note:Some data may be scaled based on tests of similar but not identical luminaries.
O O mandatory option. Consult factory. imposed
Y Y
W °-S s Iz requirements imposed on states,localities,and other
w F Please note this integrated feature come FAWS table accuracy+/-15%on these models.
y Z m standard with RoadFocus. 13 non-federal entities as a condition of receiving funds
Not available with UNV.
>C U ? Only available with SRD or SRD1 Driver Options. ^ Only available with R2M or R3M distributions. administered b the Department of Transportation or
other federal agencies.
Only available with DMG Driver Options 15 1 shield provided per LED light engine. 19 Consult Signifyto confirm whether specific accessories
o ¢O is TLRSR must be selected with D41 are BAA-compliant.
a
F ACC@SSOr12S19(must be ordered as separate line item-quickly and easily installed in the field)
WW ¢ Interact City connector node(Contact the factory for additional support when connected lighting or additional services are desired.)
JShielding accessories
_F
v.O
O Luminaire Accessory Ordering Code Shield vs Distribution Compatibility
C7 w x Description
k 3 F Option Code 12/16 LED version' 20 LED version" R2M R2S R3M R3S 4 5
W _ Cul-de-sac shieldCSS ACC-LG66V16LED-CSS ACC-LG66V20LED-CSS Yes Yes es_1iVas Yes N
W Z F m Front side shield FSS ACC LG66V16LED FSS ACC LG66V20LED FSS Yes Yes Yes No Yes O Z
E p House side shield HS ACC-LG66V16LED-HS ACC-LG66V20LED-HS Yes Yes Yes Yes No CV
y Left side shield LSS ACC-LG66V16LED-LSS ACC-LG66V20LED-LSS Yes Yes Yes Yes Yes >
c a z Right side shield RSS ACC-LG66V16LED-RSS ACC-LG66V20LED-RSS Yes Yes Yes Yes Yes O o
F O z OD =
w 0 7 Refer to Wattage table to confirm light engine configuration.Example,if configuration is 2x16LED,2 of the desired shields must be ordered per luminaire. Q (n
a Z< 1
L W 2 0 RoadFocus-RFM-Spec 04/23 page 1 of 5 TM RoadFocus-RFM-Spec 04/23 page 3 of 5 RoadFocus-RFM-Spec 04/23 page 2 of 5 J Q
v Q
F �¢ U
W U CO
w x >
Q Z U
w v LU N
a ar 0
t7 Q zo m m Z
w �' ¢¢ m I-
�' a a� Z Z Y W O
w z o LD
° w wS � w �
zQ � w
z 0 C) 11
oLu
w UJ�
�e
O w3
Q ZOS i� c
z L GO
w o� O
x° �zV. Z a c7
w . ]
W L) ¢� Z O C7 d
N3 mo w : /^ z
rA Q
P w U L
x u=O =0 w
z zo
� a F¢ w ff
�W>o 3� F ■� # ci
3;F U4wr w
CAUTION:NOTICE TO CONTRACTOR � °z �
x0Cn a
w3c4N �o
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING
X z x°� ° UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES
Q w Q AND,WHERE POSSIBLE,MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED SHEET
m W ]Z ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION
on �JjO Q >� O o CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF THE SD24
WCn zCn O
�7 u.�O H Q Know Whars below. UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING
d x Call before you dig. UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
X o.Ca.a F ce