Loading...
HomeMy WebLinkAboutPZ - Geotech Report SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmaii.com - 208-440-6276 CONSULTING, LLC Brent Thompson May 17, 2021 Iterra Homes, LLC Page 1 of 29 316 East 1400 South, Suite 2A File 20864-A St George, Utah 84790 Re: Geotechnical Recommendation Report Proposed Andorra Subdivision & Wells Street Memory Care 675, 715, & 955 South Wells Street Meridian, Idaho Brent: As per our discussions, SITE has rewritten our prior report for the subject property, addressing it to you and using your project name. The following Preliminary Geotechnical Evaluation & Recommendation Report is for both the proposed Andorra Subdivision and the proposed Wells Street Memory Care facility. In October 2019 SITE logged and sampled ten test pits on the subject property. Samples were gathered and returned to our inhouse laboratory for analysis of their engineering properties. Based on the results of our investigation and evaluation, we believe the property is acceptable, from a geotechnical perspective, for the proposed subdivision and care facility. The construction and civil engineering recommendations presented within this report are to be incorporated into the project plans and specifications and adhered to during design and construction. Recommendations are provided for the design and construction of earthwork, foundations, slab on grade concrete, flexible pavements, storm water disposal, and inspection and compaction testing requirements. Please see the following executive summary for items of concern. We appreciate this opportunity to be of service and we look forward to working with you during the design and construction of this project. Should you have any questions or require additional information, please contact our office at your convenience. Respectfully submitted; NAL Bob J. Arnold, PE 35� �iJr SITE Consulting, LL aIST ST�'p �+�,��, d 5 1?1 z, OF ® J. AA� Geotechnical Services/soil Testing&Inspection Services ZSITEI T C Post Office Box 190537 - Boise, Idaho 83719 ,] C site.consulting.idaho@gmaii.com - 208440-6276 CONSULTINGY LLC EXECUTIVE SUMMARY • Ten test pits were excavated on the property at locations shown on the included aerial photo. These test pits provide adequate subsurface information to allow SITE to provide recommendations for your project. • Groundwater was not encountered in any of the test pit locations that were at least 13 feet deep. Well Logs were researched and three from nearby or adjacent properties were copied from the IDWR website. These three well logs are included in the Appendix and indicate the static groundwater is too deep to impact or be impacted by the proposed construction. • Free-draining sand and gravel materials were present in all but two of the test pit locations at depths greater than eight feet deep. A perc rate of P=8 in./hr. can be assumed for these materials. In the north end of the development, a grade change causes the pitrun materials to be deeper. In this location infiltration facilities should extend to the deeper sands and gravels. Percolation testing at the time of construction is recommended. ■ No fat clay soil of concern was observed or sampled on this property. It is noted that highly elastic silt soils were sampled on the surface of the property. These soils will appear to contain clay when wet and can be expected to deform and rut under vehicle traffic. Drying of the soils may be required if too wet for effective compaction. • Non-fat clay materials cut from street sections and infiltration facilities can be used as structural fill on building pads and for mass grading. Structural fill is to be compacted to 95% of Standard Proctor maximum dry density. ■ Either slab on grade floors or crawlspace & foundation construction is acceptable for the planned residential structures and the care facility. • An R-Value result of R>20 was reported by the retained specialty soils lab. Their report is included in the Appendix. Based on this value and a Traffic Index of TI=6, the recommended pavement section for interior driveways is 2.5"- HMA, 4.0" - 3%" base and 10.0" of subbase. A pavement section is also provided for a Traffic Index of TI=8. ACHD should confirm this is acceptable for Wells Street improvements. N v ao a Geotechnical Services/soil Testing&Inspection services S1T E Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC INTRODUCTION Purpose and Scope This report documents our geotechnical investigation and resulting recommendations for the proposed Andorra Subdivision & Wells Street Memory Care facility. This project will be constructed on three parcels located on the west side of South Wells Street in Meridian, Idaho. Ada County Assessor records provided this information about the subject property. Parcel Parcel Number Address Acres_ 1 R-5443010070 675 South Wells Street 4.60 2 R-5443010220 715 South Wells Street 6.86 3 R-5443010210 955 South Wells Street 5.23 Total Acreage 16.59 The purpose of this report is to document the investigation of subsurface soil conditions and provide recommendations for building a Care facility and a residential subdivision. Our field investigation included subsurface exploration by means of a track mounted excavator operated by Wood Brothers Trucking. Soil samples were gathered and test pit logs generated during the field explorations. Selected soil samples were submitted to our in-house soil laboratories for testing. After the field investigation and laboratory testing was completed, all available field and laboratory test data was reviewed, the general data and assumed design information was evaluated, and this report was prepared. This report summarizes our research and recommendations regarding the geotechnical aspects of the project. Authorization Authorization to rewrite a prior SITE report for the subject property was received on April 9, 2021. Authorization and the use of the provided recommendations indicate the client's and the design team's acceptance of the scope of work, warranty, limitations, and general conditions provided herein and within our standard geotechnical proposal. m v Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-"0-6276 CONSULTING, LLC Warranty and Limitations The exploration and evaluation of subsurface conditions documented herein is considered sufficient to form a basis for the provided recommendations. The provided recommendations are based on the available soil information and preliminary design details either assumed or furnished by the client and his civil design team. It is warranted that these recommendations have been promulgated after being prepared in accordance with locally accepted professional engineering and geotechnical engineering practice. No other warranties are implied or expressed. v a Geotechnical Services/Soil Testing&Inspection Services SI T E Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-"0-6276 CONSULTING, LLC RESEARCH & BACKGROUND General In October 2019, SITE staff observed excavation of ten test pits on the subject property. During our field investigation, our staff gathered representative samples from the spoil piles and test pit walls. The samples were field classified, labeled with pit number and depth, and transported to the laboratory for additional testing. Sieve Analysis, Moisture Content, Liquid Limit, Plastic Limit, and Plasticity Index and an R-Value test were performed on selected samples. All tests were performed in general accordance with the appropriate ASTM test methods. Prior to backfilling the test pits temporary monitoring wells were installed. Six wells were destroyed since installation. These were replaced on April 26, 2021. It is recommended these wells be monitored twice monthly through the end of the irrigation season or the start of construction. Surveying of the new wells is required. Preliminary Plan & Vicinity Map A client provided a proposed layout plan and it is included in the Appendix. SITE also obtained an aerial photo of the subject property from Google Earth and reviewed all historical aerial photos available from this source. These documents were used to locate the subject property and position the test pits / monitoring wells. Historical aerial photos reveal the three parcels within the subject property have historically been rural farm properties with areas of farmland and pastureland. No prior building structures other than those currently present were observed in the aerial photos that date back to 1982. The surrounding properties include residential subdivisions to the west and office and commercial facilities to the north, south, and east. Five Mile Creek crosses the property from east to west just below the midpoint. The property is bound by Wells Street on the east, Magic View Drive on the north, Snorting Bull and Locust View Heights subdivisions on the west, and East Wells Circle on the south. All planned access to the development is from Wells Street and Wells Circle. Q a Geotechnica/Services/Soil Testing&Inspection Services 5 I T E Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmaii.com - 208-440-6276 CONSULTING, LLC Observed Subsurface Conditions Test pits were excavated in late October 2019, right at the end of the local irrigation season. At this time, the site surface was firm and stable and supported the excavation equipment without rutting or deflection. Subsurface conditions in the test pits were similar. In general, the near-surface soils consist of silts and sands with some layers that are weakly cemented and other layers that contain lean clays. Weakly-cemented, silt and sand soil were common in the test pits at four to seven feet deep. Pitrun type sand and gravel were contacted in nearly all the test pits at seven to eight feet deep. It is assumed that the higher surface elevation in the north end of the property resulted in the pitrun sand and gravel being deeper than 13 feet and therefore not reached in these two test pits. Groundwater was encountered, in TP-5 and TP-6 at eight feet deep. These are the two test pits nearest the Five Mile Drain. It is believed this is water from the Five Mile Drain perched atop the cemented silt / hardpan layer described in the test pit logs. This is based upon well logs for the surrounding area found on the IDWR website. Four nearby well logs were selected and have been included in the Appendix. The wells are on adjacent or nearby properties that are west, north, northeast, and east of the subject property. These logs reveal the static groundwater at the time of well drilling was 20 plus feet. Therefore, groundwater does not appear to reach a depth that will impact or be impacted by the planned construction. QD ru CL Gootechnical Services/Soil Testing Br Inspecilan Services SI T E Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208A40-6276 CONSULTING, LLC DESIGN & CONSTRUCTION RECOMMENDATIONS General Earthwork All native soils that are free of organic matter and expansive clays are acceptable for use as fill. After proper grubbing, the native silty or clayey sand, and sandy silts removed from the right of ways can be utilized as structural fill to fill low areas, building pads, and over-excavated soft /wet areas. These materials can also be used to fill individual residential lots. Removal of the majority of the organic materials will require grubbing of 2-6 inches of surface soils. This is required in all areas to receive structural fill. Deeper excavation may be required along irrigation ditches. After all demolition and grubbing is completed, inspection should confirm removal of foundation concrete, organic materials, and that no soft or wet areas are present beneath future pavements and structural fills. Subgrade inspection by the project geotechnical engineer prior to the placement of structural fill or pavement section layers is required. If used for fill, elastic silt and lean clay and silt soils will require moisture contents within 2% of optimum for effective compaction. The surface soils will easily become too wet or too dry for effective compaction and can be expected to perform poorly if wet and subjected to rubber-tired equipment. If construction is to occur during wet weather or wet surface soil conditions, low-pressure or track-mounted construction equipment is recommended. Rutting caused by the contactor using rubber-tired equipment on a wet subgrade can be expected and should be repaired at contractor expense. Structural fills less than three feet deep are to be compacted to 95 % of the maximum dry density by ASTM D698, Standard Proctor. For deeper fills, such as ditch backfill, and fill intended to contain rerouted irrigation canals or storm water runoff, fill materials are to be compacted to 100 % of the maximum dry density. If structural fill is to be placed on residential lots or building pads, the fill is to extend laterally outside foundations a distance equal to the depth of structural fill. Structural fill should be placed in uniform, thin horizontal lifts, moisture conditioned as necessary, and compacted to the above requirements. Compaction testing to confirm proper compaction is recommended. v Geotechnlcal Services/Soil Tasting&Inspactlon SarvlcaS SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208A40-6276 CONSULTING, LLC Excavations Excavation of native soils for utility installation can be accomplished with standard construction equipment. Hardpan /cemented soils should not require extra or larger equipment. Excavations and trenches that do not exceed four feet in depth may be constructed with side slopes approaching vertical. Below this depth it is recommended that slopes not exceed a vertical to horizontal ratio of one-to-one. The ability of soils on site to maintain a vertical or near vertical excavation over any extended period can be quite variable. Sloughing when working at or below the groundwater elevation is anticipated. This information is provided for planning purposes. It is our opinion that maintaining safe working conditions is the responsibility of the contractor. Jobsite conditions such as soil moisture content, weather condition, earth movements and equipment type, and operation can all affect slope stability. All excavations should be sloped or braced as required by applicable local, state, and federal requirements. Pavement Section An R-Value of R> 20 was obtained on a sample gathered from TP-4. Based upon this result and a Traffic Index of TI=6, we recommended the following pavement section for driveways within this development. The laboratory report for the R-Value, our calculations for this pavement section, and calculations for a pavement section based upon a Traffic Index of TI=8 are reported in the appendix. Material Layer Thickness HMA Pavement 2.5" _ Base Coarse 3/" minus 4.0" 1 Subbase (Pitrun) 10.( Materials meeting the requirements of ISPWC and / or ACHD are required for any work within this project. 00 bn a Geotechnical Services/Soil Testing&lnspectlon Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC Foundation System The proposed building structures may be supported on conventional, continuous, and isolated pad foundations founded upon the native soils or upon structural fill extending to these soils. Both crawlspaces and slab on grade floors are acceptable. Based upon proper placement and compaction of structural fill, bearing pressures of up to 1500 psf are allowed for foundations founded on the native soils or upon properly placed and compacted structural fill. If fat clays are present at the foundation support elevation a geotechnical engineer should be retained for site specific recommendations. Foundation drains are not required within this development. Foundation embedment depth is to be at least 24 inches below outside adjacent grade for frost protection. Foundations outside crawlspaces are to be sealed /waterproofed with brush or spray on foundation mastic. No basements are allowed in this development without lot specific geotechnical and groundwater studies. Slab on Grade Concrete Care must be taken so that all excavations below both interior and exterior slab on grade concrete are properly backfilled in accordance with the structural fill recommendations. Trenches and wall backfill areas are to be filled in lifts and benched each lift so that fill is not placed against a vertical soil face greater than three feet tall. Testing is to confirm that compaction has been achieved. Areas of excessive yielding should be excavated and backfilled with structural fill. Any fill used to increase the elevation of slab on grade concrete should meet the requirement for structural fill. Slab on grade floors, sidewalks and pavements should be placed atop a mat of at least four inches of granular structural fill materials. This depth is to increase to one foot when concrete is to be placed over fat clays soils. This is required to prevent seasonal heaving of sidewalks, patios, and driveways. Mat material should all pass a 3/4-inch sieve and should contain less than 7% passing the # 200 sieve. The mat shall be compacted to the requirement for structural fill. rn v Geotechnica/Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC Storm Water Due to the encountered weakly cemented silt/ sand soils above the deeper sands and gravels, percolation rates through the near surface soils can be expected to be quite variable. A perc rate of P=4 in./hr. with a drain time of not more than 12 hours is recommended for surface or shallow facilities. If a shallow facility is planned, it is recommended that this perc rate be confirmed by field testing. If facilities extend to or are over excavated to two feet into the sand and gravel (pitrun) layer the design perc rate can be increased to P=8 in./hr. Confirmation at the time of construction will be required by ACHD and is recommend for onsite locations. Underground Utilities It is not anticipated that large excavators or small backhoes will experience any difficulties excavating the onsite materials encountered on the property. No bedrock formation was encountered on the subject property. Well logs from IDWR indicate the high static water level is deep and will not impact utility construction. Perched groundwater may be encountered near the Five Mile Creek. Dewatering may be required if working near this creek. Inspection & Testing A qualified engineer or his representative should monitor fill placement to ensure the work is performed in accordance with these recommendations. Testing should be performed in accordance with ASTM Test Methods D3017-88 and D2922-91 (nuclear densometer). For mass filling, field nuclear moisture - density testing shall be performed on each lift of compacted fill, one each filled residential lot or building pad. Trench backfill and right of ways are to be tested to ISPWC requirements. It is noted that structural fill can pass compaction tests and still be unacceptable if pumping, rutting, or deflecting under vehicle or foot traffic. O v a Geotechnical Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC Contractor Inspections This report has been prepared with the intent to provide specific design information to the developer and the civil engineering consultant. It is not intended to act as any contractor's "Due Diligence" or subsurface inspection prior to estimating construction costs or actual construction. With permission, the contactor(s) can utilize the onsite wells for their own evaluation of groundwater. Wells are to be protected during construction. Contact SITE if a well needs to be relocated. General Comments After the plans and specifications for construction are completed, it is recommended that this consultant be provided the opportunity to review the final design and specifications. This review will confirm that the earthwork recommendations have been properly interpreted and implemented. At that time, it may be necessary to submit supplementary recommendations. This review is a part of this service and will not result in additional invoicing unless additional research and recommendations are needed. Testing and inspection services are recommended herein. Proper quality control during construction is required to confirm materials and methods and thereby obtain a desirable finished product. Monitoring and testing should also be performed to verify suitability of materials used for structural fills and to confirm proper demolition, subgrade grubbing, subgrade stability, and proper placement and compaction of fills. Any deviations from the herein described subsurface conditions must be brought to the attention of this consultant. This report has been prepared for the exclusive use of the client and their retained design consultants. Findings and recommendations within this report are for specific application to the proposed construction described herein and apply only to the property identified. Client may duplicate this report as needed or additional copies will be provided upon proper client authorization. Appendix Follows v a Geotechnical Services/soil Testing&Inspection services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmall.com - 208-440-6276 CQNSU LTI NG, LLB APPENDIX Location Map Preliminary Plan Concept Plan Aerial Photo with Test Pit Location Test Pits Logs (10) Soil Log Legend /Abbreviations and Acronyms Adjacent Well Logs (4) Pavement Section Calc Sheets (2) R-Value Report N rl v m o a Geotechnical Services/Soil Testing&Inspection Services S SITE Post Office Box 190537Boise, Idaho 83719 site.consulting.idaho@gmaii.com1: 1 ZCONSULTING,ULTIV LOCATION . ■ OVA! AA lyw�`- a . w rcrayrcv+x. a ••f t-it--1 ��` -- '- -,�, m �� �.` �- i �.�,�y��_,� crn�F.n.•u:xs •'•rnfGrrrlil rrur: -• �:�44IaY � MMIe' _�.f .r •, �s .ram+ �I SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC PRELIMINARY PLAN ANDORRA SUBDIVISION Y uu a•roa`wn .r�� :.. 51101L@iQ0 a3swoun .i z19m�I'uewgy ,Z,l �� i' o ' " �H NOZ i;l;•II I�I A. N NpA49(S VHlO�NVStl3NIC9i Qa t •�� wy y y3 1 E +! .�"^9 Y ' u;,W ib ' 1 1 • it g :'ryt k x i Id 51 o �Fr O� a 0m�4 ZW `Rifiy' T `•.ry I I-oi Supplied by JUB Engineering Q m Geoteclknlcal Services/Soil Testing&Inspection Servloes SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC CONCEPT SITE PLAN WELLS STREET 675 5 Yrl:l_2'c SI K T,wCAIN AN,0 9360—14'b44:3"Cj51'j . 715 5 VIEILLS STTiE'€T,F4ERIOl4N IG 83fi92 r RSi43Q!Q2i^v %5 5 V,El-S STREET,MEWDIAN,10 B3642—R54430v5M e. .•w4 a PnaMluuNo "CLI YN9 9p5&1M918 S1REEf 8 716 8IAF11,5 SINEI:T � - PUIINIE OFAC9 BURDIU6 955 5 Wam ST >,� ice= UNR9'ENSRT OPENSPryCE I �[ Supplied by JUB Engineering v Geotechnical Services/Soli Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmal1.com - 208-440-6276 ZSULTING, LLC AERIAL PHOTO TP-3 P-4 A A . TI ► do — .— i .TP-8 T P-7 or �a TP-9 TP-10 — R D 5 _ With Test Pit Locations by handheld GPS a Geotecbnical Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-1 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM -SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 1 3/8" it 4 1 #10 #40 #100 #200 %M LL PI Fines 0.0-4.0 Brown,Dry,Moist,Sandy,Silt with gravel With Root Zone/Organic Layer 6-8" 3.0 100 1 96 95 1 93 1 87 78 75 69.3 20.4 59 27 MIL 4.0-6.0 Brown/Tan,Moist,Firm,Sand&Silt 6.0-13.0 Brown/Tan,Moist,Firm,Sand,Gravel,Cobble Clean fines at 8.0' Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered(corrected) Monitoring Well in Place TEST PIT LOG Test Pit: TP-2 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM-SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 3/8" 1 #4 1 #10 #40 #100 #200 %M LL PI Fines 0.0-4.0 Brown,Dry,Moist,Sand,silt with gravel With Root Zone/Organic Layer 6-8" 3.0 1 100 99 1 98 1 95 83 74 66.6 10.3 NP NP ML 4.0-12.0 Brown/Tan,Moist,Firm,Sand&Silt Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered(corrected) Monitoring Well in Place v a Geotechnlcal Services/Soil Testing Br Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-"0-6276 CONSULTING, LLC T7EST PIT LOG Test Pit: TP-3 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM-SITE DEPTH SOILS DESCRIPTION feet 3/4" 1/2" 1 3/8" 1 #4 1 #10 #40 #100 #200 %M LL PI Fines 0.0-1.0 Brown,Moist,Firm,Sand,Clay,Silt With Root Zone/Organic Layer 6-8" 1.0-4.0 Brown Moist,Firm,Cemented/Sand with Silt 4.0-7.0 Brown/Red,Moist,Firm Sandy,Gravel 5.0 78 1 65 1 52 1 47 1 38 1 20 12 10.9 2.6 20 4 ML 7.0-13.0 Brownrran,Moist,Firm,Sand,Gravel,Cobble Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered Monitorin We11 in Place TEST PIT LOG Test Pit: TP-4 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM-SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 1 3/8" 1 #4 1 #10 #40 #100 1 #200 %M I LL I PI I Fines 0.0-1.0 Brown,Moist,Firm,Sand,Clay,Silt With Root Zone/Organic Layer 6-8" 1.0-4.0 Brownrran,Moist,Firm.Silty SAND(SM) R-Value Sampled 3.0 100 96 1 93 1 81 52 37 1 27.8 9.6 1 NP NP ML 4.0-12.0 Brown/Tan,Wet,Firm,Sand,Gravel,Cobble Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered Monitoring Well in Place 00 rl to v M �o a Geotechnlcal Services/Soil Testing&lnspectlon Services SITEPost Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-5 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM -SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 3/8" 1 #4 1 #10 #40 1 #100 #200 %M I LL I PI I Fines 0.0-1.0 Brown,Dry,Firm,Sand,Clay,Silt With Root Zone/Orcianic Laver 6-8" 1.0-3.0 Brown,Moist,Firm Block ,Sand Clay,Silt 3.0-8.0 Brown/Tan Moist Firm,Sand,Cobble,Gravel 8.0-13.0 Brown/Red Moist Firm Sand Silt 10.0 100 1 99 1 96 1 43 1 18 14.8 7.1 NP I NP ML Bottom of Excavation @ 13.0 13.0 Ground Water Encountered @ 8.0 Monitoring Well in Place TEST PIT LOG Test Pit: TP-6 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM -SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 1 3/8" 1 #4 1 #10 #40 #100 #200 %M LL PI Fines 0.0-1.0 Brown,Dry,Firm,Sand,Clay,Silt With Root Zone/Organic Layer 6-8" 3.0-8.0 Brownrran Moist,Firm,Sand,Cobble,Gravel Bottom of Excavation @ 13.0 13.0 Ground Water Encountered @ 8.0 Monitoring Well in Place �l rl v no a Geotechn/cal Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-7 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM-SITE DEPTH SOILS DESCRIPTION feet 314" 1 1/2" 3/8" 1 #4 1 #10 #40 #100 #200 %M LL PI Fines 0.0-1.0 Brown,Dry,Finn,Sand,Clay,Silt With Root Zone/Or anic Laver 6-8" 1.0-2.0 Brown/Tan,Moist,Firm Sand with Silt 2.0-4.0 Tan,Dry,Firm,Lightly Cemented,Sand&Silt 8.0-13.0 Brown/Tan,Moist,Firm,Sand,Cobble,Gravel Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered Monitoring Well in Place TEST PIT LOG Test Pit: TP-8 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM -SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 1 3/8" 1 #4_1 #10 1 #40 1 #100 1 #200 1 %M LL I PI I Fines 0.0-5.0 Brown,Dry,Firm,Sand,Clay,Silt With Root Zone/Organic Layer 6-8" Blocky below organic layer 5.0-7.0 Tan D ,Firm,Lightly Cemented,Silty SANDISM) 6.0 100 1 88 1 84 1 74 1 63 1 47 41 39.2 9.8 56 25 ML 7.0-13.0 Brown/Tan,Moist,Firm,Sand,Gravel Cobble Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered Monitoring Well in Place 0 N a� on �o a Gectechnical Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-"0-6276 CONSULTING, LLC TEST PIT LOG Test Pit: TP-9 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM -SITE DEPTH SOILS DESCRIPTION (feet) 3/4" 1 1/2" 1 3/8" 1 94_1 #1p 1 #40 1 #100 1 #200 %M I LL I PI I Fines 0.0-3.0 Brown,Dry,Firm,Sand,Clay,Silt With Root Zone/Organic Layer 6-8" Blockv below organic layer 3.0-5.0 Tan,Dry,Firm Cemented Sand&Silt 5.0-13.0 Brown/Tan Moist Firm Sand Gravel,Cobble Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered Monitoring Well in Place TEST PIT LOG Test Pit: TP-10 File#: 21864-A Client: Iterra Homes LLC Date Excavated: 10/18/19 Project: Wells Street Development Excavated By: Wood Brothers Location: See location map Logged By: J. Meusch, PM -SITE DEPTH SOILS DESCRIPTION feet 3/4" 1 1/2" 1 3/8" 1 #4 1 #10 #40 #100 #200 %M LL PI Fines 0.0-2.0 Brown,Dry,Firm,Sand,Clay,Silt With Root Zone/Organic Layer 6-8" Blocky below or anic laver 2.0-5.0 Tan,Dry,Firm,Lightly Cemented Sand&Silt 5.0-13.0 Brown/Tan,Moist,Firm,Sand,Gravel,Cobble Bottom of Excavation @ 13.0 13.0 No Ground Water Encountered Monitorin2 Well in Place N a, to a Geotschnlcal Services/Soil Testing&Inspection Services SITEPost Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208�40-6276 CONSULTING, LLC SOIL LOG LEGEND UNIFIED SOIL CLASSIFICATION SYSTEM ASTM STANDARD TEST METHOD D 2487 FOR CLASSIFICATION OF SOIL FOR ENGINEERING PURPOSE5 MAJOR DIVISIONS 1=7PICAL DESCRIPTIONS GW GRAVEL& Well-graded ravel, ravel-sand mixture,little or no fines. <5%-#200 GRAVELLY GP Poorly graded gravel,gravel sand mixture,little or no fines SOILS 5-12%-#200 GM Silty ravel, ravel-sand-silt mixtures COARSE <50%-#4 GRAINED >12%-#200FG-711 Clayey ravelgravel-sand-clay mixtures SOILS SW —Well-graded sand,gravelly sand, little or no fines. <50%-#200 SAND& SANDY SP Poorly graded sand,gravelly sand, little or no fines SOILS SM Silty sand,sand-silt mixtures >50%-#4 >12%-#200 SC Clayey sand,sand-claymixtures El Inorganic silt and very fine sand,rock flour,silty or clayey fine sand SILTS& INORGANICor clayey silt with slight plasticity CLAYS CL Lean cla -low to medium last icity,_gravelly,sandy, or siltyclay FINE LL<50% GRAINED ORGANIC OL Organic silt and organic silt clayof iow plasticity SOILS >50%-#200MH Elastic silt,micaceous or diatomaceous fine sand or silt soil. - =SILTSFat cla -hi h lastici ORGANIC OH Organic clay-med.or high plasticity:organic silt HIGHLY ORGANIC SOILS PT Peat, humus,swamp soil with high organic content ABBREVIATIONS AND ACRONYMS ASTM American Society for Testing and Materials IBC International Buildin Code ISPWC Idaho Standard for Public Works Construction ITD Idaho Transportation Department NP Non-Plastic PCC Portland Cement Concrete TP Test Pit USCS Unified Soil Classification System cf Pounds per Cubic Foot sf Pounds per Square Foot tsf Tons per Square Foot sf/f Pounds per Square Foot/ Foot (V N a, a G8016Chn1C81 SOMICBS/S011 Testing&Inspactian SBrvICOS Si T E Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmaii.com - 208-"0-6276 CONSULTING, LLC ADJACENT WELL LOG Lot 17 Magic View Subdivision Across Wells Street to the East -or STATE OF IDAHO USE TYPEWRITER OR DEPARTMENT OF WATER RESOURCES BALLPOINT PEN WELL DRILLER'S REPORT State law ragefrae thettlds report be filed with the Director,Department of Water Resources within 30 days after the completion or abandonment of the well. 1.WELL OWNER 7.WATER LEVEL Namn-C�ta'.�r-JCl.'- �1 Static water level feet below land surface. Flowing? ❑Yes ❑No G.P.M.Dma Address z—, Z:/,;e74Z Artesian closed-in pressure p.s i. Controlled by: ❑Valve ❑Cap ❑Plug Owner's Permit No, _ Temperature_OF. Duality 2.NATURE OF WORK S. WELL TEST DATA _ New well ❑Deepened ❑Replacement ❑Pump ❑Beilar ❑Air ❑Other ❑Abandoned(describe method of abandoning) ITyrnarer G}'lii Pumping Level IlainFrtrpwl 3.PROPOSED USE �Domesllc ❑Irrigation ❑Test ElMunicipal 9. LITHOLOGIC LOG ti1�i�J ❑Industdel ❑Stock ❑Wane Disposal or Injection Hole 1m Water ❑other ispecify type) Dials Ftpm To Material Y No 9,METHOD DRILLED ❑Rotary ❑Air ❑Hydraulic ❑Reverse rotary XCeble ❑Dug ❑Other r 7 5.WELL CONSTRUCTION yam, Casing schedule:P Steel ❑ Concrete El Other - TWO-ss Diameter From To 42 inches�� inches+�2 f t /Meat inches _ inches rest feet 'i�'-•^�[+"-�-.�,ti;} Inches inches feet_feet inches inches J feft�fabt c: Was casing eirle shoe used? )(Yes ❑No Was a packer or seal used? ❑Yes �No I y Perforated? ❑Yes No How perforated? ❑Factory ❑Knife ❑Torch Size of perloratims inches by_inches •es,Da- ^ Number From To perforations _feet feet 'T perfuretlons feet feet perforations foes feet J' Well screen installed? ❑Yes ❑No Manufacturer's name _ Type _Model No. Diameter_Slot size_Set from fect to_feet Diameter_Slot size_Smfrom_faetto_feat Gravel packed? ❑Yes ❑No ❑Size or gravel Placcd from faette fear Surface seal dilp IReln�rN uRy In Wf-, 0 t Oran p4'Puddling[ll y t]Will calling, Sealing procedure used: ❑Slurry pit ❑Tamp.surface rasing — ❑Overbore to seal depth Method of Joining casing:❑Threaded ❑Welded ❑Solvent Wald ❑Cemented between strata Describe access port Work started finished /-.-3 0 6 LOCATION OF WELL i 11. DRILLERS CERTIFICATION Sketch map 1w tleo rmrrl nyea wld,, IT"1—ti sn. I/We certify that all minimum wall construction standards were N complied with at the time the rig was removed, Subdivision Name ✓ / 9 Firm Nrttgr (L �Y/t•_I'L Flan No. L W E J a Address,f.:�_-.A i r (Lrf 'f'-- Lot No, ,_' Block No, Signed by(Firm anOdfficlel) _ S County d" S (Operates) /.� Y.Sec. ,T.�_N ,R. E/yr taSE ApDITMNAL SHEETS IF NECES9ARV—FORWARD 711E WHITE COPY TO THE DEPARTMENT m N GJ a Geotechnica/Services/Soil Testing&Inspection Services SSI T C Post Office Box 190537 - Boise, Idaho 83719 L site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC ADJACENT WELL LOG 2205 West Cadillac Drive Three Lots west of Property IDAHO DEPARTMENT OF WATER RESOURCES Use Typewriter G n WELL DRILLER'S REPORT sail Point Ran 1088 )1- 1.DRILLING PERMIT NO.�e _ %a,• 10.WELL TOM Mar IOWR No, ._ .. _ O PUMP ❑Geller NAir i'e rb er,o Artse an 2.OWNER. A-,„,.., a aS .�aatr.11w CiIY_..-1�e[ri"w� Ttlmperatum ut weDer___was o wafer anelyals done?YSS❑ NOV 3,LOCATION OF WELL by legal dmoriptlon: By whoc„q _ - SMnk:h msp boedon mum spree With,wrAlen loceploa. Water QufftY(odor,etc.) _ k Bottom H09 TSRlaaretutis_ 11.STATIC WATER LEVEL. T. -. NonhIky or sdtrh' _495 h.melpm rWAlce Deplh arl"4h pow Tmir,d Fmk V or woet 1-I AneWan prosaurd_ Ib Dgwrlba at-cuss pore,,,4•Q «` rj141� 1�,:¢ _Vd Dvacrlhe Cotttroltlnp OvAces: �- (lowl Lot 12.UT14OLOGIC LOG:(Daeonibe repalm or abandonment) Add..of Wall SieF__ 54YKQ ...T ^_ d. F+wn Ta I>IamPrMc I.Mealagy,WaNr OtraNly a Taa,Pwaltn qw" Ma Sm+.Piai tease P,tnfa,.avmmiim wos<.n�.nmr.kl -- .. ..�'""��T Lot No hb Bkmk No. Subd.Namr. �. 1 4,PROPOSEO USE: XOomsellc [)Municipal ❑mwaon ❑imgaiiun .'� U Thermal �6Qecbnn r7;harr_. '.r b.TYPE OF WORK _ ❑ NOW Wall L;MO"Or Repab PORSPlgpament L 1 Abandonment 6.DRILL METHOD U r 4- 0 Mud Rotary.J7 xt Fbmry 1aGaote Ll Other wl 7.SEALING PROCEDURES oulA011rERPaL,c ra4041T MaTPloo -. MPAGraI From Ta - Was drive shoe seal tested?Yu How? _ ,R S.GASINGIUNER: AN 1-1 On- h 11L.-,l+30 9 =I X a WAT /4 /Ary ;- Ci r7 = WES7EA7!pE . Final ecaaan of%hoes____ Taco P'at'itet S:r ItPnd 1 � - _ PUO. J�_ lIOII xIt TaRPIpB��__ .- - 9.PERFORATIONWSCREENS oaDe_s18n6d__j2--_-_l0 a ParrWotlons Mo hod - .. ge 13.DRILLERI CERTIFICATION get. T>rPa � - +N.. tA*o serilfy Thai all minhnum Wall cansin4 pn mandwder wore oomoied wllh at , 61,. oftr6.r ttieoePi QW9 ,:,,. 11io Wine,the rip was renewed. - �i ,4a0 ,�$II ❑ I ,, ❑ FrmNarne,�nn�e *tRri _�tpr" FlrrnTla 33 �1 L1 Firm DtM..f,g^Cr� ❑ Cl lima SuetI- 81nPervisor or Q �!! 1 CInN PFlm dl�yllLW'Wl FORWARD WHrrE COPY TO WATER Ai 50 N <v oo Geotechnica/Services/SO#Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 ZC0N:SULT1NG,F LLC ADJACENT WELL LOG 2727 Magic View Across Wells Street to the Northeast Yorm239-? STATE OF sis2 DEPARTMENT OF WATERTER RESOURCES WELL DRILLER'S REPORT n n Statelewreewiros Mat roleort rep he filed with the Director,Deparonent Of WabrR QUID QZ 17a,� within 30 days after the completion or abandonment of Me well- 1.WELL OWNER ( 7.WATER LEVEL Depatlmei11 of Water Resourf: Name_ r— 4 n e S Static waMr level Beat below I—surface. - Flowing? n YeL G,P.M.Ilew Addrex ye Q Artesian clmgsl pr IL%I. Controlled by: ❑Valve ❑Cap ❑Plug C.—rt Pvrem,No. O Temperature OF, Quality,_, pascriee ertevennl�eaaewun racy Arbi 2.NATURE OF WORK FA WELL TEST DATA VNeW well ❑Deepened ❑Replacement ❑Pump W Baller ❑Air ❑Other ❑ Abandoned describe abandonment procedures such as , materials,plug depths,ate.in lilhologie log) Perrpde DJ'.ne. Pumple Lxwl eraeae es.rYN 3.PROPOSED USE Domestic ❑Irrigation ❑Test O Municipal 9. LITHOLOGIC LOG • J 77 ❑Industrial ❑Stock ❑Waste Disposal or Injection Bore Ok M Water ❑Other (specity type) Dittm.Prom Ya Material Ye No 4.METHOD DRILLED 5u ❑Rotary ❑Air ❑Hydraulic ❑Reverse rotary a•L p•. Cable ❑Oug ❑Other t'/�.... 5,WELL CONSTRUCTION Casing schedule:1C Steel ❑ Concrete ❑Other TWO— 0—ter From A50 inches b r, inches+ Feat rest •- inches _ Inches Feet' T7��feet - inches inches Feet_feet - inches_ inches feet_ feet AM Was casing tlrive shoe used? 5(Yes ❑No Zap Acker or seal used? PC Yes �❑ o — Perforated? ❑Yes L No itlaan�,�rs How perforated? ❑Factory ❑K few ❑Torch Size of perforation _ inches by_Inches Number From To perforations _ Feet Feet perforations feet _feet _perlaratlorts Tale feet Well tarn fndallad) 'jYYn i]No Marwlxrurer i narna �±±�Q ri Typo Olarb'k"3"'Slot Mre. I.fro..- fm to Ifflt III—ray Sto,tiro—Sot from _fmW itwt Oreyet flacked) 13 Yee C.No Cl Site Or WWM r� Played from rnS 10 tact D — Iiprrace sCal i1uyF11s jr4lerlal utad In"T CI C..Wn WWI dl Wakr Benronite Xpocldiftclay l7 Western Re Tonal 011 Sealhtg ptOcvdVTf teed: 0 SlunY Plf Cl 7.np.Wrfocataa(rp Dyarbon to taml a" Mvdtod ol.loininp wriny:❑Thrasdrd Wddad n$=ft Weld 1-1 Cementedbetween strata Describe access port 10. Work started finished ZI ITS— 9.LOCATION OF WELL a' 77, DRILLERS CERTIFICATION 7:1 1 Sketch map location must agreawlth written lacatlon. + I/We certify that all minimum wall construction rl e N �:�,►120 compiled with at the time Merigwas removed, r Subdivision Nand. [� •I� `f— Firm Nllmeay ir- f11 Flrm No. ,f W e r1�� �l —. Address d ate Signed by(Firm OH le _ S County and + IDosramr lL 7S Sac. T- -w R•r f .. USE ADD 11 IONAL SHEETS OF NECTWARY FORWARD TIIE WHITE COPY TO THE OETAR7M6l17 Lt I N v a Geotechnlcal Services/Soil Testing&Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC ADJACENT WELL LOG 2662 Magic View Across Magic View to the North a state 01daho t USE TYPEWRITER 4R Depertlaent of Voter Reaon erce HALL PDINT pEH WELL DRILLER'S REPORT fig. s rarr t Stale law iequiresthetthis report be filed with the Director,Ova"""ai WoNr ��f-- days offer tho epmpl,tlwl or;ypndnnnrcnt gf the T,YII, �a"�~�,�'' V,�ufCr 'iRHtf" 1.WELL OWNER 7.WATER LEVEL um,�ypL_VpfLp_ Static water level__j3--feet below land surface 2662 Magic Viaw Dr. Flowing? 0 Yes j1 No G.F.M.IICw._- - Addtew Marl di on Idaho-Ag6ip?- Temperature °F. 0"Ity - Arteslanclosed-in pressure_ p.s-i. Owner's Permit No. - Controlled by 0 Valve ❑Cap ❑Plug - i 2,NATURE OF WORK IL WELL TEST DATA @ New wall ❑Deepened O Replacement ❑Pump 11 Bailer ❑Other Dw n Abandoned(describe method of abandoning) t n r S.PROPOSED USE � I 04mesic ❑y6l"nlsn ❑T„1 ❑ OMwbptdly fypV 029268 � 9, LITHOLOGIC LOG ❑10.1kipd ❑Indtnh'nl ❑Stock O Wes%Dlepowl w Hole Otpd' We1e' ti}ecibn Dlwe. From I T. 1i1e1 hy�rj Mn n a 12 moo 4to I I x 4.METHOD DRILLED ®Cable ❑Rotory ❑Dug Cl Other 5,WELL CONSTRUCTION Diameter of hole 6 inches Total depth_AA feet AM- Casing schedule: M Steel O Concrete Th..k- Diameter From To _-2517)-inches_6—inches +_-.L-feet Al, feet inches inches feet _feat inches inches feet feet Ir'chn.. Intswe Imt Fen inches inches feat feet Vhs c 0.9 drive(hoe toad T M Yw ❑No Was a packer or seal used? ❑Yes 60 No Perforated? ❑Yes tj No How perforated? El Factory ❑Knife ❑Torch Site of perforation —inches by—inches NamMr From To perforatlons feet feat pr.fngtion, feet ____ feet perforations Feet fees Well screen installed? ®Yes ❑No Manufacturers name--Zahn Type-3t-I al gag St:iv7 Model No. Olammet�tp.5'Igr are�5 Ser friom. I�+7 leer tn 166_.teat Diameter_Slot size_Set from feat to feet Gravel pecked? ❑Yes Q No Size of grovel Placed from - feet to feet Swtim seal drpth 20 1 _Me1Mpl uted in Mal O Camel wont ❑Peddling day ED Wtll culling, ` q Prgeeders wd Gl W."Fd ❑Tir wwy-It-a" ®O,wlrers to ma"0 lo. 6.LOCATION OF WELL � Workst,rted)l/21/7Z finished 4125/77 Sketch map location must agree with written location. {- f N 11.DRILLERS CEIITIFICATION i .-i.. _ {•_ SWdNnkn time,f�gi r. lri av Fine NonieTad Tlrtn y.l 7 Dn j1*fq2-90 w a ...1--. r Lot N.—i_ebck ro. seen adP'Ma lragnl'Itn-Vie. rkp Doti 47 • Sip"by(Fkn 011icW County. -Aa& albs �- ---- lDFwvtiq -K�.le-.%Sw 17 _T. 3 Na,R.--L—Eel '^ USE ADDITIONAL Si4ESTS IF NECESSARY FORWARD THE WHITE COPY TO THE DEPARTMENT VJ N a, DD a Geotechnical Services/Soil Test/ng&Inspection Services SITE C Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTJNG, LLB DESIGN SECTION CALCULATIONS (ACHD R-Value Method) Project: Andora Senior Living File No.: 20406-A Wells Street-Meridian caic By: B.Arnold client: Sawtooth Development Date: 01/31/20 Design Thickness Equation: T=0.0032 (TI)(100-R)(12)=GE (inches) T= Design Thickness TI = Traffic Index= 8 By Agency GE = Gravel Equivalent R = R-Value= 20 By Soils Test GE= 25.1 Inches ACHD HMA, 314" Base and Aggregate Subbase Actual Thickness Equivalent Thickness HMA Thickness= 3.0 Inches HMA= 7.5 Inches 3/4" Base Thickness = 4.0 Inches RBE= 4.4 Inches Calculated Aggregate Subbase Thickness Equation: Subbase Thickness=SB=GE-HMA-RBE SB= 13.2Inches CALCULATED DESIGN SECTION HMA= 3.0 inches 3/4" Base= 4.0 inches Subbase= 14.0 inches RECOMMENDED DESIGN SECTION HMA = 3.0 inches 3/4" BASE = 4.0 inches SUBBASE = 14.0 inches SITE uses a maximum R-Value of 20 for ACHD Designs N a a Geotechnical Servlces/Soil Testing&lnspectlon Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 ZCONSULTING, LLC DESIGN SECTION CALCULATIONS (ACHD R-Value Method) Project: Andora Senior Living File No.: 20406-A Wells Street-Meridian Caic By: B.Arnold Client: Sawtooth Development Date: 01/31/20 Design Thickness Equation: T=0.0032 (TI)(100-R)(12)=GE (inches) T= Design Thickness TI = Traffic Index= 6 By Agency GE= Gravel Equivalent R = R-Value= 20 By Soils Test GE= 18.9Inches ACHD HMA,3/4" Base and Aggregate Subbase Actual Thickness Equivalent Thickness HMA Thickness= 2.5 Inches HMA= 5.0 Inches 3/4" Base Thickness = 4.0 Inches RBE= 4.4 Inches Calculated Aggregate Subbase Thickness Equation: Subbase Thickness=SB=GE-HMA-RBE SB= 9.5 Inches CALCULATED DESIGN SECTION HMA= 2.5 inches 3/4" Base= 4.0 inches Subbase= 10.0 inches RECOMMENDED DESIGN SECTION HMA = 2.5 inches 3/4" BASE = 4.0 inches SUBBASE = 10.0 inches SITE uses a maximum R-Value of 20 for ACHD Designs 00 tw a Geotechnicai Services/Soli Testing d inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 ONSU LTI N C G,, LLC R-VALUE REPORT 'Pavement Engineering Inc. ,.Redding•Sacra memo•San Luis Obispo Concord•Saifa Clanta RESISTANCE(R)VALUE TEST ASTM D 2844 Laboratory No.: L200010 Project No.: 190027 Sample Date: January 2.2020 Report Date: January 3.2020 Client: Site Gonsgitng.LLC Project Name: 2019 I.ahoratmv xestino Sample Description: Brown Sandy Clay Sample Location: 19373.Wells Slreel 100 --- - 90 --- - 80 -- - - 70 2 60 — 50 -- 40 V - 30 -- 20 -- - - -- 10 0 800 700 600 500 400 300 200 100 0 Exudation Pressure (P.S.I.) -+ Resistance Value Test 300 P.S.I. Specimen No. 10 11 12 Moisture Content % 242 222 21.6 Dry Density PCF 94.1 96.4 96.9 (Resistance Value R 48 62 71 Exudation Pressure(PSI) 112 398 547 Expansion Pressure 17 30 43 As Received Moisture Content RESISTANCE VALUE AT 300 P.S.I. 57 ANDReviewed By: Brandon Rodebaugh k Hi0 R'F Materials Engineer N v Nothing Follows Geotechnical Services/Soil Testing&Inspection Services