Loading...
HomeMy WebLinkAboutC-PP-2.3 East Fortuna CT Utility Profile MERIDIAN CITY APPROVAL DM Partners 2815 East 3300 South, Salt Lake City, UT 84109 (801) 305-4670 www.edmpartners.com MATCH LINE SCALE: 1 = 20 SEE PP-2.2 S5 S5 \\ \\ 0 10 20 40 60 I \ " \ OWNER: S3 \ \ \\ Dawson Ranch, LLC _ I �/ S3 I \ — LOT 6 LOT 18 LOT 1� 'pC. LOT 15 \ \\ 6865 S. Pemberley P1.T S- - — — orI ��°sc �'°F�� LOT 16 OPEN SPACE Meridian, ID 83642 or 9 \ \ < s5 -v,, Contact:Jarron Langston I N S3 — — — I \ \ Phone: (208)724-6239 I — 'i li � \ \ \ \ �< I T SIDEWALK l I I \ \ ...... " N LANDSCAPING CB-8 I I I 0 `�SGT-4 8 S O LOT 24 � S8 I S2 S9 SD-3 .,t d NOTES: I S5 S2 \ S3 99.64' i2xo + S8 SD-2 — O S7 1. This drawing is considered preliminary unless ss \ \ \ is ss — s ss — 13+00 — ss ss — ss ss 14+00 ss — 15+00 15+95 affixed with a municipal approval or a. PSG \ accompanied by a separate approval document. LOT 14 \ \ 2. All sanitary sewer improvements shall conform \ S8 I EAST LA FORTUNA CT. S8 ❑S7 � S8 S9 I I S8 S5 \ \\ with the standards and specifications of the I \ COMMON DRIVEWAY M M M � � �� .. w .. � � �� �� w w \ \ City of Meridian. 3. All culinary water improvements shall conform ILOT 7 with the standards and specifications of the y \ I LANDSCAPING CB-2 I 3 S3 I City of Meridian. I S5 5'SIDEWALK 4. All improvements in the public right of way S5 I shall conform with the standards and\ i ° / specifications of the Ada County Highway S3 District (ACHD) and the Idaho Standards For Public Works Construction-ACHD Supplement S5 \ I �oh�P / F (ISPWC-ACHD). \ S3 I / / 5. All private improvements shall conform to Idaho Standards For Public Works Construction (ISPWC) standards and specifications. / LOT 12 LOT 13 6. Contractor to field locate and verify the LOT 11 horizontal and vertical location of all utilities S3 LOT 8 LOT 9 prior to beginning work. / p g g O D 5 SIDEWALK S5 PP-2.3 SEWER NOTES: EAST LA FORTUNA CT. PLAN A N 1. SEWER CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE ISPWC AND THE MERIDIAN SUPPLEMENTAL SECTION 500. PP-2.4 2. SANITARY SEWER SERVICES SHALL BE TYPE 'A'-'D' SERVICE •- CONNECTIONS PER ISPWC SD-511 WITH 2%MIN. SLOPE FROM SEWER MAIN TO RIGHT-OF-WAY. 3. SANITARY SEWER SERVICES SHALL BE MARKED PER MERIDIAN STANDARD DRAWING SW3. 2765 2765 4. SEWER MANHOLES SHALL BE 48" STANDARD TYPE A COMPLYING WITH ISPWC-ACHD SD-507 J W \ CO M SEWER KEYNOTES 2760 .9 co 7 M o � 2760 W 7 N r N S1 NOT USED ° CNN ^ N ~ 0 Ln N N 2' W W Vf Ln Q' _ INSTALL SEWER MANHOLE PER ISPWC SD-501. SEE PROFILE FOR PIPE S2 INVERTS AND RIM ELEVATIONS. 2755 2755 APPROVED FOR CONSTRUCTION: INSTALL 4" PVC SEWER SERVICE TYPE "A" CONNECTION. TERMINATE These plans are valid for construction only with the S3 LATERAL WITHIN 5' OF BUILDING. SEE PLUMBING/MECHANICAL PLANS � FOR CONNECTION DETAILS. _ _ signature of the design engineer on the line below. w 54 INSTALL 4" PVC ASTM 3034D SDR 35 PVC SANITARY SERVICE MIN, PER ISPWC SD-511 "B" 2750 _ _ — — — — — — — — — — — — — — — — — — — — 2750 Ap proved Date s5 INSTALL 4" CLEANOUT PER ISPWC SD-506A s6 NOT USED ONAL F,yG 2745 2745 w ❑ POTABLE MAIN/NON-POTABLE MAIN CROSSING. SEE SHEET C-4.0 FOR w s7 DETAILS. 14176 K, 252.89 LF of 8"SDR S8 POTABLE MAIN/NON-POTABLE SERVICE CROSSING OR NON-POTABLE 35 SS C 0.65% N�12/19/24rp MAIN/POTABLE SERVICE CROSSING. SEE SHEET C-4.0 FOR DETAILS. 9�F OF, gJ�� 2740 2740 o R . a CORE DRILL MANHOLE. CONNECT 4" SEWER SERVICE WITH KOR-N-SEAL S9 BOOT 1 12+00 13+00 14+00 15+00 15+95 Keep West EAST LA FORTUNA CT. PROFILE N HORIZONTAL SCALE: 1" = 20' Subdivision v VERTICAL SCALE: 1" = 5' East Fortuna CT Utility Plan & Profile 11+30-15+79 / PROJECT: DRAWN BY: CRS N REVIEWED BY: ERB REVISIONS: No. DATE REMARKS v H v v x / U v O Cr k DATE: Q December 19, 2024 U Y SHEET NUMBER: PPa Q 2e3 A