HomeMy WebLinkAboutAC.1_CANOPY PLAN AC.2 GENERAL NOTES CANOPY KEYNOTES
132'-0" \2/ 1. DOWNSPOUTS TO TIE INTO SUB-GRADE STORM DRAIN SYSTEM, NUMBER DESCRIPTION
CONCRETE SLAB RE:CIVIL DRAWINGS 1 SUB-GRADE DRAIN PIPE, RE: CIVIL FOR INFO.
'-0" 128'-0" '-0' 2 6"THICK, 4000 PSI, 28-DAY STRENGTH REINF. CONCRETE DRIVE SLAB
FUEL CANOPY 2. CANOPY CONTRACTOR SHALL INSTALL DOWNSPOUTS AND CONDUITS W/6x6/D5.OxD5.0 WWF AT MID-DEPTH, OVER 6" GRAVEL BASE COURSE
FOR LIGHTING, SIGN, MUSIC SYSTEM AND CCTV INSIDE COLUMNS. OR AS RECOMMENDED IN GEOTECH REPORT
11'-6" 35'-0" 35'-0" 35'-0" 11'-6" COORDINATE W/G.C. FOR EXACT LOCATION OF CONDUITS AND HAND
HOLES FOR ACCESS. NOTE: CANOPY COLUMN ACCESS PANELS FOR 3 TYPE 2A-20BC FIRE EXTINGUISHER W/MOUNTING HOOK, 48"A.F.F.
17'-6" 17'-6" 17'-6" 17'-6" 17'-6" 17'-6" HAND HOLE ACCESS SHALL FACE THE INSIDE OF THE OPPOSING 4 CUSTOMER SERVICE UNIT
COLUMNS. DO NOT FACE TRAFFIC DRIVE LANES. 5 MULTI-PRODUCT DISPENSER
c i E J c i C J 6 3'x 5'x 13" DISPENSER ISLAND FORMS (STAINLESS STEEL), CONCRETE
q FILLED. INSTALL 6" MIN. HEIGHT FROM CONCRETE SLAB SURFACE
w
7 16" DIA. CANOPY COLUMN RE: CANOPY STRUCTURAL DRAWINGS AND Q
So
ELEVATIONS FOR COLORS p
7 9 8 CONTROL/EXPANSION JOINT.
o 0 o =
o � o 0 0 9 6" DIA X 42" H PROTECTIVE BOLLARD PAINTED
�o 6 5
9 10 q 11 12 13 14 15 16
AC.3
0 4 E? 8 65'-9" z
C J CONCRETE SLAB/FUEL CANOPY
I I 1v I I 1-41" 10'-421' w 18'-0" 18'-0" 18'-0" ��
CO
a 2
oLuo o o 2 < AC.2 1O C J E
w C J
Q
0 J
z w
o u_ 1 +�IrV
3 iltV tO 8
CJ r z
o
M ilk
4 12 -102" 15'-0" 3, 0 15'-0" 3' 0 3 15'-0" 8' ()2
J
12'-0" '-0' 32' 0" '-o' 32' 0" '-0' 32'-0" '-o' 12'-0" _
a > a O C)
1 2 ;r, 3 4 5 5 6 6 7 8 +ilcV 11J ilrV - o 5 _ Lu L o z ❑ 5 ❑ C J oM0 00
Lu�o ; W � J � 6 5 < AC.3 z O C6
o o o 0 0 0 zo ? 8 Q 2 M co
9 v 9 `l am Jo000 ^
� � � _ 4 M 4 � � � MO
W LLI .�
o - 7 O � O '�
_ 00
(n coLL
0 � 00 <
-6' 129'-0"
CANOPY PLAN M
AC.1 1/8"= 1'-0" O U
AC.3
W
3 DIESEL CANOPY PLANIll-
AC.1 1/8"= 1'-0" Z
128'-0" p
FUEL CANOPY
6'-8" 10'-8" 24'-0" 10'-8" 24'-0" 10'-8" 24'-0" 10'-8" 6'-8" Z
4'-10" 5'-10" 2 5'-2" T-6" 1� :1"
5'-64 5-14 T-10" 4'-10"
65'-9" �
1 DIY-10"
CONCRETE SLAB/FUEL CANOPY 11 w
1-� 4'-10" 9'-4" 4'-2" 9'-4" 4'-6" 4'-10" 9'-4" Y-10" 4'-2" 6'-22
`�' II II II II
II o II o o II o 0II ^
2 +❑ ❑+ +❑ + ❑+ ❑+ + U)
II II II W
o II II II II 2 � 5 nn nn � w
II II II J
5 II 4
0 0 + ❑+ ❑+ ❑+ ❑+ ❑+ O
+ ❑+ +❑ ❑+ ❑+ I ❑+ +❑ O 7
1 }
a
a CD CD 3 r'j El W o_ Q
aN 3 Lu
(.I 3 w
w '-` O
ui
0
II II II II °'
II II II II v J U)
--L
II II II II 0
Ijk +16'0" O U
� � � BOT
TOM OF DECK LL
II II II II
N
-L-L L4 DIESEL REFLECTED CEILING PLAN +15'-6" w Lu
_LL1 a /ikAC.1 1/8" = 1'-0" BOTTOM OF p
FASCIA
0Lu
z
BTTM FDEK c w
O ~
O
+15'-6"
2 CEILING PLAN BOTTOM OF
FASCIA � N
KEYNOTES - CANOPY CEILING PLAN DRAWN CMHDATE
12/12/24
NUMBER DESCRIPTION
CHECKED
1 CANOPY RECESSED LIGHT FIXTURE, BY LSI, VERTEX, FLAT LENS, MODEL:
SCV-LED-20L-SC-U NV-DIM-50-W HT,
2 SHELL PECTEN PANEL. SEE ELEVATIONS JOB NO. 24020
3 METAL PAN DECK COLOR"WHITE", RE: CANOPY STRUCTURAL DWGS
4 16" DIA. CANOPY COLUMN. RE: CANOPY STRUCTURAL DRAWINGS CANOPY PLAN
5 PUMP NUMBERS ATTACHED TO COLUMNS. MOUNT 106.3"A.F.G PER SHELL STANDARDS
ACA
COPYRIGHT 2024 BRS ARCHITECTS*ALL RIGHTS RESERVED. REPRODUCTION OR TRANSLATION OF ANY PART OF THIS WORK WITHOUT WRITTEN PERMISSION OF BRS ARCHITECTS IS UNLAWFUL AND SUBJECT TO CRIMINAL PROSECUTION.