HomeMy WebLinkAboutLandscape Plan W. CHINDEN BLVD. (HWY 20/26) ,,��a�������y,��
r -EP EP EP NOTE: CALCULATIONS SHOWN BELOW ARE TO DETERMINE THE REQUIRED NUMBER OF TREES PER CITY OF MERIDIAN ���` �$OFIo
UDC AND ARE NOT OPEN SPACE CALCULATIONS. REFER TO THE OPEN SPACE EXHIBIT FOR OFFICIAL QUALIFIED .` �P' .••••..`91y '•,
OPEN SPACE CALCULATIONS.
Ar OPEN SPACE TREE CALCULATIONS (1TREE/5000SF) '•�vCCA
tl
� i I LOT QUALIFIED
`L' =
BLOCK # LOT # AREA (SF) QUALIFIED AREA (SF) AREA (AC) REQ PRVD �v' . .A 9
17 18 672 672 0.02 0 0 �••� hND•••F�Qt�•,,
- - \ •
17 28 31,502 31,502 0.72 6 9 ��00881181116"�,
17 49 36,642 36,642 0.84 7 9
TOTAL OPEN SPACE TREES 13 18
- - PATHWAY TREE CALCULATIONS (1TREE/100 LF)
L — — BLOCK # LOT # LF CALC REQ PRVD
Lu
17 28 789 789 LF/100 8 8 0
/ C-G I FUTURE HOSPITAL 17 49 1294 1294 LF/100 13 13
I /
TOTAL PATHWAY TREES 21 21
MITIGATION REQUIREMENTS
I
THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL
I
TOTAL TREES REQUIRED/PROVIDED 34 39 L'
z
0
FUTURE PRESCOTT RIDGE cn
SUBDIVISION PHASE TREE PROTECTION NOTES w W
—
1. THE CONTRACTOR SHALL TAKE EXTREME CARE TO PROTECT 4. COMPACTION BY EQUIPMENT TRAFFIC IS PROHIBITED WITHIN
THE CRITICAL ROOT ZONE OF ALL TREES AT ALL TIMES THE CRITICAL ROOT ZONE.
THROUGHOUT PROJECT.
5. MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE.
2. PRIOR TO COMMENCING WORK, TEMPORARY FENCING SHALL APPLY A MIN. 1.5" OF WATER OVER THE CRITICAL ROOT
.
INSTALLED I AROUND IMPACTEDZONE PER WEEK THIS IS A MIN RECOMMENDATION.
ON
30 32 34 36 .
BY DEMOLITION OR CONSTRUCTION. FENCING SHALL BE CONTRACTOR IS RESPONSIBLE TO DETERMINE IF (MORE
I 38 MAINTAINED THROUGHOUT THE COURSE OF THE ENTIRE WATER IS NECESSARY DURING CONSTRUCTION.
33 35 41 43 } DEMOLITION AND CONSTRUCTION PROCESS.
6. ANY DAMAGE TO EXISTING TREES DURING CONSTRUCTION
42 Q
BLOCK 17 3. BULK MATERIAL, EQUIPMENT, VEHICLES, AND CONSTRUCTION SHALL BE THE CONTRACTORS RESPONSIBILITY. THE
N. HIGHFIRE LOOP Y DEBRIS AND WASTE SHALL NOT BE STOCKPILED WITHIN CONTRACTOR SHALL PERFORM REMEDIAL WORK TO o
0 THE CRITICAL ROOT ZONE. DAMAGED TREES AT THE CONTRACTOR'S EXPENSE. z
27 u W. LOST RAPID ST.
2625 59585756::55 53 S2 s0X ACHD LANDSCAPE NOTES
54 48 46
24 44 51 1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR
{ 47 45 z ZONE OF ALL ACHD STORM DRAIN PIPE, STRUCTURES, OR
BLOC 17 + FACILITIES.
21 fi 2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL
20 60 61 62 63 64 +. CONTAMINATION DURING THE CONSTRUCTION AND
— — - INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM.
18 19.. .. 65 66
3. ALL TREES SHALL BE PLANTED A MINIMUM OF 5' FROM ALL
W. WILDFIRE DR. 67 ACHD CURBS AND/OR ATTACHED SIDEWALK, UNLESS
7/7 PLANTED WITHIN THE PARKSTRIP. ALL TREES PLANTED IN
U PARKSTRIP SHALL BE CENTERED.
"4 PLANT SCHEDULE NOTE: SEE L2.0 FOR COMPLETE PLANT SCHEDULE. (/)
- - p z
SYMBOL CODE BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS QTY z Q
PRESCOTT RIDGE DECIDUOUS TREES z 0L
SUBDIVISION NO. 4 O �
�D > 0 Lu
Al ACER TRUNCATUM PACIFIC SUNSET'TM 2"CAL. B&B 35 X30 CLASS II 7 (n z
PACIFIC SUNSET MAPLE _ w
GLEDITSIA TRIACANTHOS'SKYLINE
GS2 2"CAL. B&B 35 X30 CLASS II 13 w
SKYLINE HONEY LOCUST m z > U
Lu
°C PRESCOTT RIDGE Q Q
pSUBDIVISION NO. 3 + FA TILIA CORDATA'GREENSPIRE 2"CAL.B&6 45 X35 W CLASS II 13
2 PRESCOTT RIDGE GREENSPIRE LITTLELEAF LINDEN , n Q
I.0 SUBDIVISION NO. 1 �•J w _
o w Q
EVERGREEN TREES J
• PP3 PICEA PUNGENS 6'-8'B&B 60'X30' EVERGREEN 3 ~ Q
COLORADO SPRUCE U
O
PINUS FLEXILIS'VANDERWOLF'S PYRAMID U
PV VANDERWOLF'S PYRAMID PINE 6 8 B&B 25 X15 EVERGREEN 3 W z
-10
SOD/SEED
PRESCOTT RIDTURF SOD GE v w
/ TOUS
SUBDIVISION NO. 2 TR RH ZOMATOUSOTA L FESCUE SOD 49,650 SF
a_
z
0
z
u II
a
N
O
M Q
z
zz
mz
z Q
v U
N
Y
0
Z Lu
z — — — — —
H
All
u
z
0
u
I
z
3
a
w
a
LANDSCAPE COVER
Z E N G I N E E R I N G
35725 NORTH DISCOVERY WAY
BOISE,IDAHO 83713
0 150 300 450
ti PHONE(208)639-6939
" Plan Scale: 1" = 1501 kmengllp.com
z
z
3 DESIGN BY: KAC
a
CONTACT INFORMATION DRAWN BY: KAC
u
OWNER/DEVELOPER LANDSCAPE CONSULTANT CHECKED BY: KAC
o HUBBLE HOMES, LLC KM ENGINEERING, LLP DATE: 08/23/24
701 S. ALLEN ST. #104 5725 NORTH DISCOVERY WAY PROJECT: 24-188
w MERIDIAN, IDAHO 83642 BOISE, IDAHO 83713 SHEET NO.
CONTACT: AUSTIN EDWARDS PHONE: (208) 639-6939
3 PHONE: (208) 433-8800 FAX: (208) 639-6930 L1.0
EMAIL: oedwards®hubblehomes.com CONTACT: KAYLEE CANDRIAN, PLA
a EMAIL: kcandrian®kmengllp.com
N
d
9 8 3 4—RN 3—BF 10—SM 5—CK3��5—HS
3—BF 5 1 8 7 1 PLANT SCHEDULE ...% ,, ,TEDFID�g�'•,
2—PP 1—PV 3—GS2 2—FA 5—HS 3—BF 5—CK3 9—MM 3—BF 4—RN 4—GS2 I �`� C. ���N •,�O .,
PI PI W I W W W PIS ®® ® p O p O + + + + + + + + O O' O O ® ® W w w W w w w SYMBOL CODE BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS QTY �•�
w . w . w . y w w . ., w . . . . w w = • ,
PI° PI PI PI PI w WWWWWWW WW WWWWWW w w wWWWwWWWwW � Ww w w 15 DECIDUOUS TREES Zv `�
•
W W w /
Wtw W W W W W W W W W W s 4-SM 6"S w p 6^ W W s' W W W W W W w I AJ ACER TRUNCATUM 'PACIFIC SUNSET`TM 2'CAL.B&6 35`X30` CLASS II 7 A 9 7839
\� HS- S Pj I I PI I '• •• ••
W w W w w W W w W W 0 s w W w W w PACIFIC SUNSET MAPLE ' • 9/O•:.�f�•
• •
•L`9NDSCA4� .
•
RG2-4 �' �' . °. w . .
w W w W W W w W W W W W 5—CK3 30 32 5 34 36 w
0 4—RN 2—AJ
,
O GLEDITSIA TRIACANTHOS`SKYLINE'
ou GS2 SKYLINE HONEY LOCUST 2"CAL.B&B 35`X30` CLASS II 13
w w O w
W W W W W w 5—HL2
W W W W W W W W W W + I
� 11
W 12W W 3—HS
W o + 31 33 v W 5—LM2 1 TILIA CORDATA`GREENSPIRE`
g w w W W W W W W W W W W W W W w W W W W W W W W N 29 35 w w 41 43 � + FA 2"CAL.B&B 45`X35` CLASS II 13
W w W W w W w w W 13 W W 6 W +
3 a ® 1-FA 1 7 GREENSPIRE LITTLELEAF LINDEN
L4
+ w
5-CK3 FA- 3-RG2 W W 37 �, I 4
WWWWWWWWWWWWWWWWW28 W . . w . wW . . 4—RN LM2-5 4—SS2 W 39 I EVERGREEN TREES a
PP3 rest w w w w W w . 4—SM HS-3 I 4�wn°"° o
WW W W W W W W W W W W W W W s a v SS2-4 PICEA PUNGENS
W w W W W W W W W W W W W W W W W W W W W W W W b y W RG2-3 O 40 42 i 16 z PP3 COLORADO SPRUCE 6-8'B&B 60`X30` EVERGREEN 3
w w w w w W w W Q a w 4. a a I non, '
40
W W W W W F W ° 7r- PINUS FLEXILIS`VANDERWOLF`S PYRAMID`
BLOCK 17 w w w <Q 4-RG2 BF_2 I 1 PV VANDERWOLF'S PYRAMID PINE 6'-8`B&B 25`X15` EVERGREEN 3
w . w . w . w . w . w . w . w . w . w . w . w . w w r a
`� a 3—HS �
W w w w w f 0 � � a �T
W W WWWWWWWWWWWWWWWWWWWWWWWWWW �' N. HIGHF LOOP OOP W W a EXISTING TREES
N
W I EXISTING TREE TO REMAIN Z
M
S S 3 S 3 S S S W S °Q
s 1
� I
PER PRESCOTT RIDGE SUB.N0.1 a O
W vi a ° I SP EXISTING VARIES 10
yy n �' a LANDSCAPE PLAN.PRESERVE AND PROTECT. to
W SEE KEY NOTES AND TREE PROTECTION NOTES.
W "SD* W6"�D �6�S� _ � � � v � >o y, s s I W W � � H_
W W W W W W W W W W s SM-5 ° o s s S w w — w SYMBOL CODE BOTANICAL/COMMON NAME SIZE MATURE HXW CITY
AJ— e W W
N S 4—SM P HS— ° o o s 1 SHRUBS
_ 3 4—RG2 `� S S 3 `� 2
5-CK3 BB-4 D p o S s I S o BF BUXUS MICROPHYLLA`FAULKNER` 2 GAL. 4'X3` 14
LM2-5 `s 6 1 1 O FAULKNER BOXWOOD
5—HL2 FA— w ;.
+ 5—RG2 > P �'° o HYDRANGEA PANICULATA`LITTLE LIME'
} + HL2 2 GAL. 4•X4' 16
�_ 0 3 O 4—SS2 W W Q LITTLE LIME HYDRANGEA
59 57 W s< p ,` I Y ROSA X'NEARLY WILD`
I 0 0 RN NEARLY WILD ROSE 2 GAL. 2'X3` 16 0
2—GS2 SS2-4 % Q
/ W 3—HS N v z
3 RG2— ® 4—BB
1 N GRASSES
w W 52 ® —FA
Is- 3 5—CK3 RG2-4 50 I °C � � BOUTELOUA GRACILIS`BLONDE AMBITION'
4—RG2 S8 56 I I Z 1yC BB BLONDE AMBITIONS BLUE GRAMMA GRASS 1 GAL. 3 X3' 33
° a o GS2—
M _-1—AJ SM-6 BB-5 W 5—LM2 54 5 ® 46 c I 1 •_j CK3 CALAMAGROSTIS X ACUTIFLORA`KARL FOERSTER` 1 GAL. 4'X2' 30
w 2—SS2 1—FA MM- HS- v FEATHER REED GRASS
9—SM Wit,
� _ 3—MM 5—LM2 I +} MM MISCANTHUS SINENSIS`MORNING LIGHT` 1 GAL. 5•X4' 25
24 44 PI PI P[ w 6 I -yvf' EULALIA GRASS
51 I SCHIZACHYRIUM SCOPARIUM`STANDING
i , P PI w W GS2- RG2-7 4-RG2 SS2 OVATION` 1 GAL. 3•X3` 23
N W W W W W W ® W W W W W W 47 45 I 16 STANDING OVATION LITTLE BLUESTEM
g w w w + + w 2—FA MM-3 6—BB _
HL2
o —° a W W w W W W w W w W W w W W-�W W w WW W w W 3—HS 1—MM BB—3 1 PERENNIALS
23 0 WWWWWWWWWWWWWWWWW WWWWW WWWWWWWWWW W WWWWWW IW PIW I 6—LM2 6—RG2 FA— HS-3
� O I HS HEMEROCALLIS X`STELLA DE ORO` 1 GAL. 1•X2• 40
WBLOCK 17 STELLA DE ORO DAYLILY
LJJ w w w w w w w w w w w w w w w w w w w w w w w w 1°
u= W w W W w W W W w 3 W W W w W w w w W W W W W W w w +, ®® 0 I W ;WI W P W I LAVANDULA ANGUSTIFOLIA'MUNSTEAD` (n
w-_ wLn
�. ® LM2 1 GAL. 2'X3` 49
o W 5 O g + I F MUNSTEAD ENGLISH LAVENDER
p
w w w w w w W w W W w W W w w 49 w W W W W W w W w W RUDBECKIA FULGIDA`GOLDSTRUM` Q
22 Z s w w w +W w w w w w w w ti • ) RG2 1 GAL. 2•X2' 65 z
® + w W W W W W w W w w w W W W w W W w W w I �/ GOLDSTRUM BLACK-EYED SUSAN J
SALVIA NEMOROSA'MAY NIGHT'
' ® 7 SM MAY NIGHT SAGE 1 GAL. 2'X2` 66 O
N 12"SD Id T Id Id♦ I Id Id I ° Id a1°W W W W w W W W H�-
-� 1 W 2—SS2 W W W /d / W W W W W W W W W W W W W W 1B SYMBOL Y W
° 1 1—FA ° W W W W W W W W W W W Lw S OL CODE BOTANICAL/COMMON NAME CONT CITY —
w 1—AJ MM— /y + W c > zQ
N W RG2-5 MM— FA— �\ s. + W f-G2 W w W 11 OTHER
W_ 2—SM ld w f w W 1. I) LLJ J
N _ 6 LM2-7 RG2-7 EXISTING LAWN,SHRUBS,AND PERENNIALS 7 \ �
1—AJ ® W W W W W W EP2 TO REMAIN PER PRESCOTT RIDGE SUB.NO.1 NONE 8,670 SF m z / W
10 GS2— 1 1—AJ o ii° �W W W W W Q LANDSCAPE PLAN.PRESERVE AND PROTECT. Q O Lu
20 1-PV W 1 S w w SEE KEY NOTES
60 61 62W w W W w W 15
63 SM-8 , SOD/SEED W — cif
F w 64 MM-.3 W � W ,, nn 0
w TURF SOD RHIZOMATOUS V
W W w W PV- W / W W 3 TR SOD 49,650 SF W ` z
RHIZOMATOUS TALL FESCUE Q Q
J
s I ' q ° a W 65 �. LM2-6 /y w w W W
° a s SM-7 s ° /
MM— ra. +° + ~ Q
7
FA— KEY NOTES TYPICAL # U 0
BB-3 �/ � � z
—W w w w w w w w w v' HL2-3 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL TREES WITHIN TURF AREAS. LLJ
w w w w Q
CA (n
T1 I `� W Q/ ? / ♦ 2. 40' CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISION TRIANGLE. THE MAXIMUM HEIGHT J
W. WILDFIRE DR. 67 / / ♦ OF ANY VEGETATIVE GROUND COVER AT MATURITY WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE
I W , ♦ �' ADJACENT STREET GRADE.
` > a /� , / ♦ 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH ORGANIC PERMABARK (ROCK) MULCH WITH PERMEABLE FABRIC
LANDSCAPE PLAN \ /� WEED BARRIER. MATCH PREVIOUS PHASES. THE USE OF MULCH OR ROCK AS THE ONLY GROUND COVER IN
Z ip / ♦ REQUIRED PLANTING ARES IS PROHIBITED. IMPERMEABLE PLASTIC WEED BARRIERS ARE PROHIBITED.
z 0 30 60 90
a `, / ♦ 4 4. 10' EXISTING ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL
a� Plan Scale: 1" = 30' 7 /� ¢ / ♦ ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES.
N / ,
� / / ♦ 5. INSTALL FLAT—BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER BED. SEE L3.0-2.
z
o W 6. 5' WIDE PATHWAY. SEE CIVIL PLANS.
a
w Q 7. 5' HEIGHT CLEAR VISION WROUGHT IRON FENCE. SEE L3.0-8 AND L4.0 FENCE PLAN.
w
Y 4f 8. 8' HEIGHT SOLID CONCRETE WALL. MATCH PREVIOUS PHASES. SEE L3.0-7 AND L4.0 FENCE PLAN.
3
M 9. EXISTING FENCE TO REMAIN AS A PART OF PRESCOTT RIDGE SUBDIVISION N0. 3 LANDSCAPE PLAN. PRESERVE AND
o PROTECT. SEE L4.0 FENCE PLAN.
10. MAILBOX CLUSTER. SEE ARCHITECTURAL PLANS.
0
"� 11. ARBOR STRUCTURE BY OWNER. SEE L3.0-3 REFERENCE IMAGE.
Z
3
w
12. PAVILION STRUCTURE BY OWNER. SEE L3.0-4 REFERENCE IMAGE.
a
Z 13. BBQ STATIONS BY OWNER. SEE L3.0-5 REFERENCE IMAGE. E N G I N E E R I N G
35725 NORTH DISCOVERY WAY
14. FIRE PIT BY OWNER. SEE L3.0-6 REFERENCE IMAGE. BOISE,IDAHO 83713
PHONE(208)639-6939
15. LIMIT OF DISTURBANCE. SEE KEY NOTE #16. kmengllp.com
Z
3 16. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN PER PRESCOTT RIDGE SUBDIVISION NO. 1. RETAIN, PROTECT, DESIGN BY: KAC
o AND OR ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND PATCH BACK ALONG DRAWN BY: KAC
PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW AND EXISTING LANDSCAPE SHALL BE NON
N RECOGNIZABLE AND COHESIVE WHEN FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE CHECKED BY: KAC
0 PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION. THE CONTRACTOR DATE: 08/23/24
o SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT
FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED PROJECT: 24-188
w PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS SHEET NO.
N DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN
Z OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION.
3
ti
a
N
d
��////Ifff1III
REMOVE DEAD DAMAGED GENERAL LANDSCAPE NOTES ,• •,S P��oFID��Io�•
BRANCHES AND PRUNE TO 1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS 9. FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND ;0y�� NL'�•: *10
INTERNATIONAL SOCIETY OF SHOWN ON THIS LANDSCAPE PLAN AND IN THE PLANT EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE •^z y;, , ,�
ARBORICULTURE STANDARDS; SCHEDULE SHALL BE THE RESPONSIBILITY OF THE WITH SITE GRADING PLAN. SLOPES FOR TURF AREAS SHALL _ t- • ' �'
IMPROPERLY PRUNED TREES LANDSCAPE CONTRACTOR. IF QUANTITIES LISTED DO NOT NOT EXCEED 3:1. '%� : W
p (AS DETERMINED BY THE CORRELATE WITH WHAT IS SHOWN ON THE PLAN, THE % �; LA-9 7839 ; ti
QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. THIS 10. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER J' • • •� 41
p LANDSCAPE ARCHITECT) INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, MANUFACTURER'S RECOMMENDATIONS AND SHALL OCCUR ,<"IJ�•�9r'O� ?.�f�•• C,•••
p p p SHALL BE REMOVED AND •
(2)-BVC WOOD TREE p p REPLACE. TOPSOIL, MULCH, SEED OR SOD, EDGING, AND DRIP LINE AFTER TOPSOIL PLACEMENT AND PRIOR TO INSTALLATION OF ��L`9NDSCA4�P`•
•
STAKES(MIN. 6' HT) p p p QUANTITIES.TRUNK FLARE. LOCATE PRIOR PLANT MATERIALS AND MULCH. ������///////���••
CHAINLOCK pOpO p TO PLANTING. FLARE SHALL 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN
TREE TIES BE VISIBLE AFTER PLANTING. LANDSCAPE ARCHITECT OF AVAILABLY OF SPECIFIED PLANT NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN.
p MATERIAL FROM COMMERCIAL NURSERIES. IF A SPECIFIED PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING
6" MULCH PER PLAN KEEP PLANT IS NOT AVAILABLE, THE LANDSCAPE ARCHITECT WILL CONDITION.
3„ MIN 1"-2" AWAY FROM TRUNK + PROVIDE ALTERNATE PLANT MATERIAL SELECTIONS. SUCH
FLARE ;v CHANGES SHALL NOT ALTER THE ORIGINAL BID PRICE 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED
UNLESS A CREDIT IS DUE TO THE OWNER. FROM AROUND THE UPPER PORTION OF THE ROOT BALL.
r
FINISH GRADE
3, MULCH AT 3 METAL BASKET WIRES AND BURLAP SHALL BE PULLED BACK
_ 3" HT. WATERING BASING PLANTER 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING AND TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON
BALD = - BERM TURF 8" BEDS - UNDERGROUND AND OVERHEAD UTILITIES WITHIN CONTRACT ALL TREES AND LARGE SHRUBS. ALL SYNTHETIC BURLAP w
DEPTH� I FERTILIZER TABLETS
WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG LINE, SHALL BE REMOVED FROM ROOT BALLS PRIOR TO <
INC. @ 1.800.342.1885. PROVIDE ADEQUATE MEANS OF BACKFILLING. o
-I � -III I FOLD BACK BURLAP FROM PROTECTION OF UTILITIES AND SERVICES DESIGNATED TO
III III- I TOP j OF ROOTBALL. _ _ _ �:'. REMAIN. REPAIR UTILITIES DAMAGED DURING SITE WORK 13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD
-� � REMOVE WIRE BASKET. - I I-I - = -III h I��I OPERATIONS AT CONTRACTOR'S EXPENSE. OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE
NOTE: REMOVE TREATED ROOT- BACKFILL SOIL MIX GENTLY _ ^ [��� 1 BY OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD
BALL PACK BACKFILL USING WATER III=III- _ _ �� 4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES OR NOT IN HEALTHY CONDITION IMMEDIATELY WITH
OR SYNTHETIC BURLAP
WIDTH " ' o -III III- , r �� THROUGHOUT THE DURATION OF THE CONTRACT PERIOD. COMPARABLE SIZE AND SPECIES AT NO COST TO THE
COMPLETELY. REMOVE TO SETTLE SOIL AROUNDI SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS OWNER.
ANY SOIL AND/OR ROOTBALL FINISH -� I i I I II 1= =1 I I I=I �[ 1} [ [ THAT REQUIRE MITIGATION, NOTIFY THE RESPONSIBLE
MULCH AWAY FROM 8" MIN PLANTING PIT 8" MIN ROOTBALL ON UNDISTURBED GRADE I-III-III -III I �_ -� TOPSOIL PERSON IMMEDIATELY. FAILURE TO NOTIFY THE RESPONSIBLE 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM
TREE CROWN AFTER
INSTALLATION. PIT SHALL BE A MIN. 2 TIMES WIDER SOIL } } 1s, s PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING PLANTING TABLETS. QUANTITY PER MANUFACTURER'S
THAN ROOTBALL AT BASE AND A CUT EDGE w - CONDITION. RECOMMENDATIONS. N
MIN. 3 TIMES WIDER THAN ROOTBALL ti; ,�. z
AT FINISH GRADE. DEPTH SHALL BE f. . = 4"' -'t 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR 15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: O
NOTES: SAME AS THE ROOTBALL. _ ""��.! x PREPARING ALL PLANTED AREAS. ALL DELETERIOUS N
.- �r - ». a .. MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, PRUNING, CULTIVATING, WEEDING, WATERING, AND _
1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED -�.w .if + ; , w
STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL 1 �� - AGGREGATE BASE MATERIAL, ASPHALT, ETC.., SHALL BE APPLICATION OF APPROPRIATE INSECTICIDES AND
STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD. REMOVED PRIOR TO ANY FILL OPERATIONS. FINISH GRADES FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF
TO TOLOW
DECIDUOUS TREE PLANTING AND STAKING DETAIL SHOVEL CUT EDGE ARBOR STRUCTURE REFERENCE IMAGE ANDBHIGHOOTH P INTSNANDVTO PROVIDETPOSIITIVEEMOVE DRANAGE. OWNERS AND DISEASE UNTIL FINAL ACCEPTANCE BY
NTS 2 NTS 3 NTS 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS 0 RE-SET SETTLED PLANTS TO A PROPER GRADE AND
PER SPECIFICATIONS. SOIL SHALL BE FREE OF HEAVY, STIFF POSITION.
CLAY AND ANY DELETERIOUS MATERIAL OVER ONE INCH IN
SIZE. REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE. 0 RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND
REMOVE AND REPLACE DEAD MATERIAL.
7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN
AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED 0 TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED
SEEDS, ROCKS, GRASS, OR OTHER FOREIGN MATERIALS AND ONLY IF ORIGINALLY NEEDED.
A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT o
MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE 0 CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER z
RESPONSIBLE TO EITHER: PROVIDE APPROVED IMPORTED DEFICIENCIES BECOMES APPARENT AND WEATHER AND
TOPSOIL OR, AMEND THE ON-SITE TOPSOIL. SEASON PERMIT.
8. TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE
APPLICABLE): LAWN AREAS-6" MIN.; PLANTER BEDS - 12"
MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL
BE TREATED WITH A PRE-EMERGENT HERBICIDE.
- GENERAL IRRIGATION NOTES
1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A
- UTILITIES ARE SHOWN, OR SHOWN CORRECTLY. CONTRACTOR COMPLETE UNIT PRODUCED BY A SINGLE ACCEPTABLE
SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS,
OF ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY AND ACCESSORIES.
DAMAGE TO EXISTING UTILITIES SHALL BE CONTRACTOR'S
* RESPONSIBILITY. 15. A MIN. OF 4" POP-UPS ARE TO BE USED IN ALL LAWN
Ir 2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND AREAS. DRIP IRRIGATION TO BE USED IN ALL PLANTER
INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES BEDS.
Ln
ir ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE V)
AREAS. THE WORK SHALL CONSIST OF PROVIDING AND CIRCUIT PIPING. WATER VELOCITY IN ALL PIPES SHALL NOT Z
INSTALLING ALL MATERIALS NECESSARY FOR A COMPLETE EXCEED FIVE FEET PER SECOND. MINIMUM PIPE SIZE TO 0
SYSTEM INCLUDING POINT OF CONNECTION, PIPE, VALVES, BE 1„ z
FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL
- _ ASSOCIATED LABOR. THE CONTRACTOR SHALL FURNISH THE 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES z
- - LANDSCAPE ARCHITECT WITH A SHOP DRAWING SHOWING
_ UNDER ALL ROADWAY, PARKING, AND WALKWAY SURFACES.
EXTEND 6" MINIMUM BEYOND SURFACE EDGE. IDENTIFY
_- THE DESIGN LAYOUT, PIPE SIZE AND TYPE, VALVE ENDPOINTS OF SLEEVING. (/O z
LOCATIONS AND TYPE, HEAD LOCATIONS AND TYPE, -
)
CONTROLLER LOCATION AND TYPE WIRE SIZING ETC... FOR _
w
APPROVAL PRIOR TO CONSTRUCTION. J
18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD > 0 : Q
PAVILION STRUCTURE REFERENCE IMAGE 5 BBQ STATION REFERENCE IMAGE FIRE PIT REFERENCE IMAGE 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND SURFACES NOT PROTECTED BY A VERTICAL CONCRETE -NTS NTS NTS Co ii
FEES REQUIRED FOR THIS WORK CURB SHALL BE PLACED 18" FROM THE EDGE OF THE 0
ROAD SURFACE. z > 0
4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR Q O W
DEFECTS. 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO Lu
PROVIDE 120 VOLT POWER AND ALL REQUIRED CIRCUITS 0 Q
5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND FROM THE ELECTRICAL PANEL TO THE IRRIGATION w - U
LOCAL LAWS AND ORDINANCES. CONTROLLER. SIZE WIRE AND CONDUIT AS REQUIRED. r n US
6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING 0 w 0
UTILITY SUPPLYING WATER FOR PREVENTION OF BACKFLOW IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW - w Z
AND BACK-SIPHONAGE Lu Q
CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. REPAIR J
INCLUDES BUT IS NOT LIMITED TO PIPING, VALVES, HEADS,
;. ` 7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED DRIP COMPONENTS, CONTROL WIRES AND EQUIPMENT, AND Q
TO PROVIDE ONE HUNDRED PERCENT (100%) COVERAGE SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR SHALL U
WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS O
APPROPRIATE. OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING r , Ln
} CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS `/
} 8. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. (n z
- HAVE MATCHED PRECIPITATION RATES WITHIN EACH w
'rt CONTROL VALVE. 21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE Q
--- x` OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF THIS
X �► PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TOInL
9. IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE
ly� -` = OR OTHER HIGH WATER DEMAND AREAS SHALL BE COARSE OF CONSTRUCTION.
CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM
3 - ---- THOSE IRRIGATING TREES, SHRUBS, OR OTHER REDUCED 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR
WATER DEMAND AREAS. DISCREPANCIES BETWEEN DESIGN DRAWINGS AND ACTUAL
10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY
° REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES SUCH AS ALL INFORMATION PROVIDED ON DRAWINGS. CONTRACTOR
_.
SHALL STOP CONSTRUCTION AND CONTACT THE OWNER
STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING AREAS.
IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES
N x -~ }• 11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM OCCUR.
PSI IS ADEQUATE TO FURNISH AND INSTALL A COMPLETE 23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE
z _ �:.�;;1+-y' - - = -^ ..• _ IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE WATER IRRIGATION CONTRACTOR SHALL PROVIDE A NEAT AND LEGIBLE
- COVERAGE TO ALL LAWN AND PLANTING AREAS. SHOULD
AS-CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND
dr ,,ep !.ti:. �. h: THE PSI BE LESS THAN ADEQUATE, NOTIFY THE MAINTENANCE MANUAL, AND UP TO (8) HOURS OF ORIENTATION
L,rAgg�: .. .� �,, :•+� ,;;;•.-.'.,:.. . ARCHITECT IMMEDIATELY. IN THE EVENT THAT THE AND/OR TRAINING FOR THE OWNERS MAINTENANCE AND
�: •� fi. L
a ;- :;.,,b 'x,:± ' ',�ito:e ;, ,_ {Sf; l:,::; _ 4� ,•r ,:_;.":y_? ti ARCHITECT IS NOT NOTIFIED PRIOR TO THE START OF OPERATIONS STAFF.
vzi. CONSTRUCTION, THE CONTRACTOR SHALL ASSUME FULL
s ti r, yt•f !� y� !,•,'- RESPONSIBILITY FOR ANY NECESSARY REVISIONS. 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF
vA
ONE YEAR FROM THE DATE OF IT'S ACCEPTANCE. REPAIR OR
0 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR
W HEIGHT SOLID CONCRETE WALL REFERENCE IMAGE T HEIGHT CLEAR VISION WROUGHT IRON FENCE REFERENCE IMAGE FAUCETS, VALVE BOXES, AND VAULTS WITH DURABLE TAGS SHALL BE COMPLETED PROMPTLY BY THE IRRIGATION
N7 CARRYING THE WARNING "DANGER-UNSAFE WATER OR CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
o NTS NTS NON-POTABLE WATER." 25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE
z OWNER, SPRING START UP AND WINTERIZATION DURING THE
13. INSTALL ALL PIPING AND VALVES IN PLANTING AREAS GUARANTEE PERIOD.
w WHERE POSSIBLE, AND LOCATE ELECTRIC CONTROL AND
a
o QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS, E N G I N E E R I N G
3 6" TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF
ACCESS. 5725 NORTH DISCOVERY WAY
BOISE,IDAHO 83713
PHONE(208)639-6939
kmengllp.com
z
Z
a
DESIGN BY: KAC
z
DRAWN BY: KAC
CHECKED BY: KAC
z
DATE: 08/23/24
0
u PROJECT: 24-188
w
0
SHEET NO.
z
L3.0
a
N
d
•`,, TE OF I o ,,,,•
�•.......••/x
s' I t A-9� 7839
i %•Q910312�.•• •�
30 32 34 36 ' I ,,"""'sc13
Ap��•,••
S 38
nmo om
29 31 33 35 1° 41 43 I
I
28 37 I
39 F-
S
40 42
.d d
BLOCK 17 a ° 4
< °
N. HIGHFIRE LOOP ° I
a Q d N
d z
4 0
rT
4
3 27 o A o
�. Ir
v
B
\� 26 I Y
53 p O
H
a° a
52 N
25 58 56 I z
a > °
44 51 i
S° 47 45
o as °o
° 23 0 S
w BLOCK 17
I
S
p z
Ln
EL
22 /�
.S °S. d° S I z LL
Lu
1 I p LEI z
s mz > Q
s I � Q O �
60 61 62 63 / L Q LU
64 / — U
W
o �
LEI LL
L u
L-j °1 S
7
ui
r ,
N
W. WILDFIRE DR.
N
N1
C
z FENCE PLAN
n 0 30 60 90 /
Plan Scale: 1" = 30' /
m w
c R�
z
FENCE SCHEDULE
w
Y SYMBOLS DESCRIPTION
3
Z 5' HEIGHT CLEAR VISION WROUGHT IRON FENCE. SEE L3.0-8.
0
X X 8' HEIGHT SOLID CONCRETE WALL. MATCH PREVIOUS PHASES. SEE L3.0-7.
r
z
0 EXISTING FENCE TO REMAIN PER PRESCOTT RIDGE SUBDIVISION NO. 3 PHASE.
z' PRESERVE AND PROTECT.
3
a
w
a
E N G I N E E R I N G
3
5725 NORTH DISCOVERY WAY
BOISE,IDAHO 83713
°° PHONE(208)639-6939
z
kmengllp.com
z
3 DESIGN BY: KAC
a
z
DRAWN BY: KAC
z
CHECKED BY: KAC
z
DATE: 08/23/24
0
PROJECT: 24-188
w
0
SHEET NO.
z
s
4.
a
N
d