HomeMy WebLinkAboutUtility Plan IYE a LEGEND
I � H
- - - - - T
PROPERTY LINE � � o
0 T W EXISTING WATER LINE LO CD o
T ` C'V CO
� —� p w r�— ~
W PROPOSED DOMESTIC WATER SERVICE LINE w N
T p — ti
°a ° a SD
F PROPOSED FIRE WATER SERVICE LINE • x 0 0
G a a o ° T\ I w EXISTING SANITARY SEWER LINE14
•
a e a o
d Q SS SS PROPOSED SANITARY SEWER LINE w o o
x 12 m
/ p ° s�
O I ° l 4, EXISTING IRRIGATION LINE O U = c
�r P T P —P P P P ' P P P P P n
T T ��_
T T T T T T T GAS GAS GAS PROPOSED GAS LINE pC m �
M W PROPOSED END CAP C00-0 7D
PROPOSED TEE
W W W W W
i
I � ��� INTERNAL ACCESS ROAD PROPOSED FIRE HYDRANT
=> � 18"SD 18"SD ® PROPOSED WATER VALVE
0/ a PROPERTY LINE PROPOSED SEWER CLEANOUT
/ a FO — F FO
PROPOSED 12" Store:
2700 N EAGLE RD
00
MERIDIAN, ID 83646
24"cl— �-2a' 24"cl 4GI 24"GI 24"JI 4"4 i Id d Id— STORM DRAIN PIPE —
o n al Id T d d d - - d- - -Id
_ r i PROPOSED SEEPAGE — — — — - — — PROPOSED STORM — — � — — — — —
r Q I I BED#1 f CATCH BASIN _ — — _ Restaurant Al 218
EXISTING PRESSURE I _
_ ° 1 ,1 IRRIGATION AIR b 85.0' �.
pl
RELEASE VALVE o ®p ®p \ I I M M M M M P6�V�AV
IUlI I I I �� PROPOSED 12" KEN McCRACKEN,
a °a 1 EXISTING 2" PRESSURE II PROPOSED ROOF PROPOSED SAND STORM DRAIN PIPE Q
`' -- `�� - " C�Z �� , Q ARCHITECT
IRRIGATION SERVICE �� DRAIN CONNECTION AND GREASE TRAP Architecture•Program Management•Permitting
I � GAS OA GAS \
N I O
�h PROPOSED ROOF
PROPOSED STORM PROPOSED GAS DRAIN CONNECTION PROPOSED GAS LINE �V PROPOSED 9540 MAROON CIRCLE
CATCH BASIN _ __ _____ _ __ _�__�,__ NYOPLAST I / SUITE 260
c� 45° BEND CLEANOUT c / 181 181- ENGLEWOOD, CO 80112
c� I a r11� 1 - Cn
P
[7 G7 ��� 1 II I / PHONE:303.731.3764
PROPOSED GAS y \\� PROPOSED 6" w CONTACT:TODD WOODY
NLY 45° BEND PROPOSED SEWER STORM DRAIN U
EMAIL:TWOODYC�PMDGINC.COM
co BUILDING CONNECTION —`\\ PIPE U
G ° ' :2 I _
N 1 / PROPOSED SEWER PROPOSED ROOF I I I I I I — DRAIN CONNECTIONJo -CHICKEN FINGERS CLEANOUT (TYP) Q 0
Z KEN MCCRACKEN, ARCHITECT
4 ° I C1218 co SEWER LINE PROPOSED ROOF
PROTOTYPE P6-V-AV DRAIN CONNECTION w
w w w w w m 1 I I N I I 2,862 GROSS S.F imley* Horn
I I PROPOSED WATERrc
_ PROPOSED SEWER O
m I -
PROPOSED GAS LINE w
O � I BUILDING CONNECTION � BUILDING CONNECTION � 3
PROPOSED 12"
I 'CA � PROPOSED FI�E 1100 WEST IDAHO STREET
STORM DRAIN PIPE cn I I --„ 0 I PROPOSED FIRE HYDRANT f1 BO SEITID 813702
0 I C I i BUILDING CONNECTION ® PROPOSED 6
Q I I I I F— FIRE LINE � PH: 208-845-0089
O I w m i 1 i i —Tfan--7 PROPOSED 45° I I PROPOSEI11 D TAP INTO
PROPOSED 6"
WATER BEND (TYP) SEWER LINE PROPOSED 8" , I EXISTING WATER LINE
LJJ I ° a° I I I N I PROPOSED 45° WATERLINE I PROPOSED 45° BEND
o EQ ° II II I 0 II II r
_ PROPOSED 45° BEND
PROPOSED 6 IF - - PRELIMINJARY
VAN FIRE LINE w PROPOSED
FIRE BEND TYP W WATER METERT T— tJ v I
W s FOR
REVIEW ONLY
°
O I I I 1 N I )0 NOT 15�1'1E E co PROPOSED 8"TO PROPOSED s � NOT FOR
-p I z i — ° I I i I I PROPOSED CLEANOUT (TYP) co 6" REDUCER 1 WATER VALVE I CONSTRUCTION
I PROPOSED SEWER O 0 SS CONNECT WATER — — — J ICIm »)Horn
-1LINE TO EXISTING
0 L GAIS 45° BEND (TYP) PROPOSED 6" 8" LINE Kimley Horn and Associates,Inc.
1 I a CONNECT TO EXISTING PROPOSED SEWER —> SEWER LINE
GAS LINE STUB CLEANOUT (TYP) I CONNECT
PROPERTY LINE PROPOSED SEWER SEWER LINE TO
C> I a ° II j ) CLEANOUT (TYP) "I EXISTING 8" LINE
u u I I 1I
PROPOSED SAND
PROPOSED SEWER
1 ° 11 I I I AND GREASE TRAP 60.0'
PROPOSED 12 GREASE TRAP PERMIT SET
rT
00 I I IC 0 PROPOSED STORM STORM DRAIN PIPE w
CATCH BASIN o ISSUED
I
l IA# DATE DESCRIPTION
a —r-- �— PROPOSED 12"
Ix ° I I I I STORM DRAIN PIPE / m
33
PROPOSED SEEPAGE
1 11 1 PROPOSED STORM I BED#2 — — —
1 CATCH BASIN
0
s
°
I — - - - J
G I I EXISTING 2" PRESSURE I
IRRIGATION SERVICE I U
G�
0 I I a ° I 1 i PROPERTY LOT LINE <—
�I L — —
I 0
_
a .4 1 —
W_
C
ap 1 II
c,
0
c a° —
c/ Sheet Title:
UTILITY PLAN
co D
d a I�
s
- II i _ Date: 5/28/2024
_ I NORTH Project Number:CL 093610018
Ld I Drawn By: SAH Checked By: MPO
rr
Sheet Number:
m a p �\ �� i GRAPHIC SCALE IN FEET
0 10 20 40
C2.0
o mm \
oThs I
U
I -n
Y