Loading...
HomeMy WebLinkAboutWATER SEWER PRELIM-C2.0 Nasland 1109 W Main Street,Ste.660 T(208)918-4859 Boise,ID 83702 nasland.com Civil Engineering Consulting Land Planning M M M e N.89'46'00"E. 132 .12" SD SD 7 8 So - - 480.70' - 18 17 GENERAL NOTES: EAST FRANKLIN ROAD 1. ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT VERSION OF THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), THE CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC (AND ANY ADDENDUMS), MERIDIAN DESIGN STANDARDS, THE REQUIREMENTS OF THE ADA COUNTY HIGHWAY DISTRICT (ACHD), AND/OR THE REQUIREMENTS OF THE IDAHO TRANSPORTATION DEPARTMENT (ITD). THE MORE STRINGENT OF ANY OF THESE STANDARDS SHALL BE THE CONTROLLING STANDARDS OR SPECIFICATIONS. �ag N.89'4 'oo" _ 2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON-POTABLE WATER MAINS (SANITARY SEWER, 5 .37 5832359"E• 7p•65' STORM DRAIN, AND IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET. WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL 0 0 ROPOSED WATER SERVICE EASEMENT SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES -- . . s .' FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA O e 58.01.16). • 3. STORM DRAINAGE SHALL BE RETAINED ON SITE THROUGH SURFACE AND/OR SUBSURFACE FACILITIES. 4. FOR ALL RESIDENTIAL AND NEW NONRESIDENTIAL CONSTRUCTION THE LOWEST FLOOR ELEVATION OF ANY STRUCTURE, . . . . . . ' ` INCLUDING BASEMENTS, OR MOBILE/MANUFACTURED HOMES, SHALL BE ELEVATED TO THE FLOOD PROTECTION PROPOSED 20' UTILITY EASMENT o `: :` :`` ELEVATION OF NO LESS THAN TWO (2) FEET ABOVE THE BASE FLOOD ELEVATION. :;: : ::� a : 5. THE PROPOSED FINISH FLOOR (FF) ELEVATIONS SHOWN ARE APPROXIMATELY TWO (2) FEET ABOVE THE BASE FLOOD 2621.00 FF ELEVATIONS. PRIOR TO SUBMITTING A FLOODPLAIN DEVELOPMENT PERMIT APPLICATION THE APPLICANT SHALL •;•;•; ; { CONTACT THE CITY FLOODPLAIN ADMINISTRATOR IN ORDER TO DETERMINE THE BASE FLOOD ELEVATIONS. FEMA ELEVATION CERTIFICATES SHALL BE FILED FOR EACH BUILDING THAT FALLS WITHIN ZONE AE. N I O Z PROP SSMH-1 STA: 10+ 2622. GRIM. . . . . . . 2615001 •. „ e • . e• SEWER DATA TABLE C CP CP CP CP I. + f LINE # LENGTH DIRECTION SLOPE NOTES L1 175.00' NO°05'21"E 0.60% 8" PVC TYPE SDR-35 ` d] d] d] d] Al L2 177.74' NO°05'21"E 0.60% 8" PVC TYPE SDR-35 L3 86.08' N82°07'23"W 0.60% 8" PVC TYPE SDR-35 - - - - - - - - - - a : : L4 173.38' S89°39'47"W 0.60% 8" PVC TYPE SDR-35 L5 182.23' S89°39'47"W 0.60% 8" PVC TYPE SDR-35 .a • o M CP CP CP C Al w Lill ' 1e• • (� • ° 9 ` N 0 A :it PROPOSED 30' UTILITY EASMENT o L ROPOSED•FIRE SERVICE EASEMENT I M j-1 I Jl I i� wI ice •. LO J ROPOSED FIRE HYDRANT,'•`•`- w LO . • • ° �� G cn I o z Z Q W Z J� PROP SSMH-2 STA: 11+75.00 2623.81 RIM 2613.951E W 2623.15 FF LILI•° e wi CD � V! Ln M (r, ° O 0 Z e A • °• • z w Ss Q CP CP CP CP ROPOSED• WATER SERVICE EASEMENT Q Pgnposm 8" wATFR MAIN, cn I 2621.50 FF O I W 30' S.89 28' "E. 283.06' di di Fi N ` A' ° n 'e e e e e \ V / f J 0 - PROPOSED 20' UTILITY EASMENT • ' + a I EX CB G v Q L _ A. �_F_ A, ' a' 2616.00 FF i z :-PROPOSED FIRE SERVICE EASEMENT 04 I U Q Q ° JA u e • ° II O I Z N :PROPOSED•FIRE HYDRANT ROPOSED WATER SERVICE EASEMENT J O ° 'e .7 '• ° °• ' �' a 1e M I I I z :�:;:;. . . . .�PROPOSED 30 UTILITY EASMENT a . ;:;::: : ' ROPOSED ^30' UTILITY EASMENT Q p PROP SSMH-3 STA: 13+52.74 • • - . . . . . . . . . . :•. 2622.45RIM • L 1 +0 - - - =.-r. -.;Q - 1 +94 cn 2612.871E 3 SEWER LINE A 17+00 - < Q S- 15+ L4 S L5 S W Q C w W w II u S.89 0'52-W. 474.59' ROPOSED 8" WATER MAIN PROP SSMH-5 N STA: 16+12.19 N 0 PROP SSMH-4 STA: 14+38.82 2616.16RIM PROP SSMH-6 N STA. 17+94.42T w CD 2621.16RIM 2611.311E (2614.82RIM) ss I o 0 2612.401E (2610.221E) 30 0 30 60 90 120 CD CONNECT TO EXISTING SEWER SEWER MAIN I SCALE 1" = 30' CIO