Loading...
HomeMy WebLinkAboutLandscape Plan-L100 1 2 3 4 5 6 7 8 9 10 STACK ROCK G R O U P LANDSCAPE ARCHITECTURE & MASTER PLANNING (208) 345-0500 404 S 8th St. #300A1 Boise, ID 83702 LANDSCAPE NOTES: LANDSCAPE REQUIREMENTS StackRockGroup.com 1. REGULATIONS & STANDARDS contain rocks, sticks, lumps, or toxic matter and has a pH of fully intact. CODE REQUIREMENTS PER MERIDIAN CITY CODE WILLET C HOWARD, PLA 1.1. All contractor work shall be conducted in accordance with 6.5-8.0. 8.4. Install outdoor rated controller in specified location on plan, in a OFFICE: (208)345.0500 EMAIL: ISPWC Idaho Standard Public Works Construction), 2020 or 4.5. Smooth, compact, and fine grade topsoil in lawn areas to lock box with 2 keys. Coordinate with project manager and WILL. STACKROCKGROUP.COM ( ) ( P 9 p Y p l 9 STREET BUFFER: W�.sTACKRocKGRouP.coM most recent published); and City of Meridian, ID codes, smooth and uniform grade .5" below adjacent surfaces. general contractor on exact location. 1 TREE PER 35 LINEAL FEET standards and state and local regulations. 4.6. Amend all new plantings with 2 parts topsoil, 1 part compost. 8.4.1. Controller to have On/Off rain switch or rain shut off device 2. EXISTING CONDITIONS 5. LAWN AREAS that does not alter program. a STREET NAME - LENGTH (LF, MINUS CURB CUTS) TREES REQUIRED TREES PROVIDED THE GRAPHICS AND DESIGNS 2.1. All utilities shall be located prior to construction and protected. 5.1. Sodded lawn to be tall turf-type fescue, or approved other. 8.5. All remote control valves (including master control valve)to . E FRANKLIN RD - 130' 4 4 ON THIS SHEET A R E Any damage to structures, utilities or concrete will be replaced 5.2. Sodded lawn to be regionally/locally harvested, lay sod within have flow control device. . LOCUST GROVE RD - 92' 3 3 DELIVERABLES THAT REMAIN at contractor's expense. 24 hours of harvesting. 8.6. Irrigation system piping to be minimum class 200 PVC or AT ALL TIMES PROPERTY OF 2.2. The site has many existing improvements such as underground 5.3. Lay sod to form a solid mass with offset, tightly fitted joints on approved equal, sleeves to be double the size of pipes located STACK ROCK GROUP, INC. utilities, curb and gutter, light poles and sidewalks. even grades. within, all wires to be contained in separate sleeves 1-1/2" dia LANDSCAPE ALONG PATHWAYS: 2.3. See Engineer's plans for information about existing features. 5.4. Any existing lawn that is damaged shall be replaced with min. 1 TREE AND 15 SHRUBS PER 100 LINEAL FEET REPRODUCTION OR REUSE OF 2.3.1. Refer to civil plans for all existing and/or proposed drainage sodded lawn of the same type of existing lawn. 8.7. All pipe above 3" caliper to be gasketed, with approved joint THIS PRODUCT CONTAINED pipes & locations, utilities. Protect all drainage at all times, 5.5. All lawn areas adjacent to planter beds, gravel areas, or restraints at all 45, TEE, ELL, 22, 11. HERE I N I S PROHIBITED PATHWAY - LENGTH (LF) TREES REQ'D/TREES PROVIDED SHRUBS REQ'D/SHRUBS PROVIDED WITHOUT THE WRITTEN protect all utilities at all times. aggregate pathways shall have 4" black steel edging installed 8.8. Use common trenching where possible.. . EAST & NORTH PATHWAY- 670' 7/7 101 / 113 3. GRADING & SITE PREPARATION per manufacturer recommendations. Other applications to be 8.9. All PVC located under hardscapes to be schedule 40 PVC with CONSENT OF STACK ROCK 3.1. Prepare finish grades for planting by grubbing and removing approved by owner and landscape architect. same req's as above. G R O U P , I N C weeds. If necessary apply Round-Up (or equivalent herbicide), 5.6. Lawn adjacent to buildings, structures shall be a minimum of 8.10. All wires to be Paige wire 7350 or 7351 direct bury wire at a MINIMUM PLANT SIZES: using a certified applicator. Remove rocks and other materials 18" away from foundations. Lawn adjacent to fences or other minimum of 12" below finished grade. 02024 STACK PLANT TYPE: MINIMUM SIZE ROCK GROUP, INC. over 2". screening elements shall be a minimum of 9" away. 8.11. Connect mainline to point of connection in approximate location . EVERGREEN TREES: 6'-0" HT. MIN. 3.2. All gravel overprep to be removed and disposed of off site. 5.6.1. Install$" chips or other approved gravel mulch type in mow shown on plan. . ORNAMENTAL TREES: 2" CALIPER MIN. 3.3. Finish grade to be smooth transition to allow for entire site to be strip at a depth of 3" over commercial grade weed barrier 8.12. Contractor is responsible complying with all codes and paying . SHADE TREES: 2" CALIPER MIN. a natural flowing space. fabric installed per manufacturer recommendations. all permits necessary. . WOODY SHRUBS: 2 GAL. MIN. Seals PRELIMINARY 3.4. Fine grade lawn areas to elevations set by Engineer's plans 5.7. Provide tree rings with a minimum 3' diameter around all trees 8.13. Sprinkler heads shall have matched precipitation within each with positive drainage away from structures. located in lawn, mulch type & installation/application to match all control circuit. Velocities shall not exceed 5 feet per second. OF 3.5. Refer to Engineer's plans for grading information &for all other planter beds. 8.14. All drip irrigation to be buried 2" below finished grade. drainage pipes and locations. Protect and retain drainage at all 6. PLANTER BED MULCH 8.15. Water schedule to be provided at a min of 80% times. 6.1. All planter beds to receive 3" depth of black&tan mini rock evapotranspiration as determined by the local ET. 3.6. No pooling or standing water will be accepted per industry mulch or approved equal, submit for approval prior to 8.16. Install all irrigation per irrigation drawings. utilize material o standards. placement. Install over commercial grade weed barrier fabric specified or approved equal. 4. SOILS per manufacturer recommendations. 8.17. Contractor shall confirm the static water pressure at least five 4.1. Lawn areas shall receive 12" min depth of screened topsoil. 7. PLANTS days before construction begins and to contact the landscape sF LA-16733 4.2. All planter beds shall receive 18" min depth of screened topsoil. 7.1. All plant material shall be installed per industry standards. architect in writing if the pressure is below 80 psi. O 8.05.2 P� 4.3. Reuse of existing topsoil that has been stockpiled on site is 7.2. All plant material shall meet or exceed the minimum federal 8.18. If any discrepancies are found, then local codes shall prevail. gNDSCAPE permitted if: standards as regulated by ANSI z60.1, American Standard for 9. CONTRACTOR RESPONSIBILITIES 4.3.1. Topsoil is tested and analyzed to ensure a proper growing Nursery Stock. Plants not meeting these standards for quality, 9.1. Estimated quantities are shown for general reference only. NOT FOR CONSTRUCTION medium. Provide additional amendments as determined by or plants determined to be unhealthy by Owner's representative, Contractor shall be responsible for all quantity estimates. soil tests. will be rejected. 9.2. All plant material and workmanship shall be guaranteed for a 4.3.2. Topsoil is to be loose, friable sandy loam that is clean and 7.3. All Ball and Burlap trees to be installed per Balled and period of one year beginning at the date of Acceptance by free of toxic materials, noxious weeds, weed seeds, rocks, Burlapped planting detail. All shrubs to be installed per detail. Owner. Replace all dead or unhealthy plant material LU grass or other foreign materials. 7.4. Trees and shrubs over 30" shall not be planted within clear immediately with same type and size at no cost to Owner. 4.3.3. Topsoil shall have a ph of 6.5 to 8.0. vision triangles. 9.3. Landscape contractor to turn in as built drawings at the end of 4.3.4. If on site topsoil does not meet these minimum standards 7.5. Fertilize all trees and shrubs with 'Agriform' planting tablets or project. Substantial completion will not be granted until 2 copies contractor is responsible for providing approved imported approved equal. Apply per manufacturers recommendations. @ 1"=20' scale are turned in and approved by owner's topsoil or improving onsite topsoil per the approval of the 8. IRRIGATION representative. project manager. 8.1. Irrigation system shall be built to the following specifications: 10. In the event of a discrepancy, notify the Landscape Architect 4.4. If imported topsoil is used it must be from a local source and be 8.2. Adhere to city codes when connecting to city water. immediately. screened free of any debris or foreign matter. Topsoil must not 8.3. All irrigation material to be new with manufacturers'warranty CV CO ce) 00 0 Z Q 0 NOTE: 2 NOTES: NOTE: BACKFILL SHALL BE 100%TOPSOIL. *CURB &ADJACENT PAVEMENT PER CIVIL OR HARDSCAPE PLANS Z REMOVE ALL TAGS, TWINE OR WATER SETTLE ALL PLANTINGS TO *TREE&SHRUB TO BE INSTALLED PER RESPECTIVE DETAILS 1. DO NOT DAMAGE OR CUT LEADER OTHER NON BIODEGRADABLE ENSURE PLANT ROOTBALL *PLANTS&MULCH PER PLAN J Z 2. DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. MATERIALS ATTACHED TO PLANT OR MAINTAINS " HEIGHT ABOVE J 3. TREE STAKING SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED ROOT MASS. EXISTING SOILS WHEN COMPLETE. Y FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE. z Q 4. WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. 11� 5. REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP 3 OF THE ROOTBALL. LL 6. S DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3"OF MULCH MIN. DO LLI NOT PLACE MULCH WITHIN 2"OF TRUNK OF TREE. MOUND PLANTER 3.5"ABOVE TOP L0 CUB LL 16 x 4"X 16'COMMERCIAL STEEL EDGING BY SURE-LOC OR APPROVED OTHER. COLOR: PROVIE V MIN STEP SPACE TOP SOIL DEPTH AS BLACK FINISH. W Z FOR ADJACENT PARKING FINISH GRADE AT LAWN,AND ' ^ 0 (� MULCH 2"MIN. EACH SIDE,TYP SPECIFIED PLANTER " BELOW TOP OF PLANTER FINISH GRADE " V, � TOP TWO STRUCTURAL ROOTS: <3" BELOW TOP AWAY FROM TRUNK FINISHED GRADE .5" TOP SOIL DEPTH AS STEEL EDGER. BELOW TOP OF EDGER. U GRAFT VISIBLE ABOVE SOIL FOLD BURLAP FROM TOP OF PLANT. SPECIFIED \ V 0 OF ROOTBALL. LINE BELOW TOP OF OF ROOT BALL DOWN 3" DEEP MULCH MIN. CURB, TYP J LOWEST STRUCTURAL SOIL LINE OF THE TOP OF INTO GROUND; SET TOP 1'-0 OF BALL FLUSH WITH OTHER PER ROOT<5" BELOW TOP OF THE ROOT BALL AFTER FINISH GRADE CIVIL, TYP _ REVISIONS ROOT BALL LAWN OR PAVING � I—III—III—III—III—I I I REMOVING EXCESS SOIL. ' � I—III—III—III—III—I \212' 2-3"OF MULCH MIRK DATE Description BACKFILL MIX SEE I I—I I I—I I I NOTES AND 12"TO 18" FOR FIG /\//\//\//\ / //\//\//\' FIG =III—III—III—III—I ® ** ** _.L. SPECIFICATIONS. LARGER SHRUB ROOT BALLS, \\\\\\\\\\\\\ \\\\\\\\\\\\\ �—III—III—III —I — — —_—_ SOIL SAUCER>3" HIGH MAKE DEPTH MIN. /\�//\�//\�//\�//\ \ \ /\�//\�//\�//\�//\\ I I_—I I I=I I I=I I I III=III=III=III- 4" DEEPER THAN \/\/\/\/\ /\/\/\ \/\/\/\/\ �-III=III=1 I=III=III=III=�REMOVE AT END OF BALL) //\ PROJECT \\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\ —I I I—I I F I I I=� I I-1 I I- - I BALL AND BURLAP PLANT(IF - CONTAINER-GROWN PLANT /i// // // // // // // // // BASKET FROM TCUT AND FOLD OP OF -� SOIL SURFACE WITH ROOTS LOOSENED AND \ \�\\�\\�\\�\\�\\/�� 12" LONG METAL ANCHOR m ROOTBALL COMPACT SOIL UNDER ROUGHENED TO PULLED OUT TO PREVENT /��//////\//\/�\/ STAKES INSTALLED @48" ROOTBALL TO 90% PROCTOR. BIND WITH NEW SOIL PLANT FROM BECOMING ROOT \ \��� O.C.,AND AT EACH END. BOUND) JOB NO: 24-2989 DATE: 08.05.2024 DRAWN BY: DW BALL & BURLAP TREE PLANTING 2 SHRUB PLANTING 3 PLANTER ISLAND DETAIL 4 STEEL LANDSCAPE EDGING CHECKED BY: WH 3/4" = 1'-0" 3293-01 1"= 1'-0" 329333-03 3/4" = 1'-0" P-CO-01 3"= 1'-0" DRAWING TITLE LANDSCAPE NOTES & DETAILS W w a w SHEET NUMBER U a O Ll00 0 Y U O Y U Q H U 1 2 3 4 5 6 7 8 9 10