HomeMy WebLinkAboutPublic Utility Plan LEGEND
PROPERTY BOUNDARY
BUILDING SETBACK
LANDSCAPE SETBACK
DQD4 PROPOSED PUBLIC UTILITY EASEMENT
-n-n-n-n-n-n-n-n- EXISTING SANITARY SEWER LINE
-ss-ss-ss-ss-ss-ss-ss-ss- PROPOSED SANITARY SEWER LINE
SS SS SS SS SS SS SS SS SS SS SS ;S SS SS SS SS SS SS SS SS SS _Ss.w w w EXISTING WATER LINE
w PROPOSED WATER LINE
Du-Du-Du-Du-Du-Du SCHEMATIC DRY UTILITIES (ELECTRIC, GAS, TELECOM)
PROP. ELEC. CONN.
COVERED PARKING
- - - - - -
> -
'. l_
Z
EX. 30' IRRIGATION -
7E
EASMENT j
S
I I
\ I I I I I
0
� � I
PROP. 20' WATER
Ic EX. 30' IRRIGATION L i - EASEMENT
\ \ EASMENT n
PROP. ELEC.
I
\� TRANSFORMER I
PROP. SSWR CO - - -
INV IN: 2610.28 6" PVC - - - -
INV OUT: 2610.28 6" PVC -
EX. FIRE HYDRANTIli DU-DU-DU-DU-DU-
TO REMAIN PROP. FIRE HYDRANT
-DU DU-D
PROP. EASEMENT
INV IN: 2602.87 8" PVC PROP. SSWR CONN. fill
ATE
C PROP. SSWR INV. I III I
INV OUT: 2616.00 6" PVC c EX. 30' IRRIGATION
�
---- INV IN: 2602.95 6" PVC I • 6 ® 9.88% 6" 09.88% a I EASMENT
-es PROP. 2" WATER o
--- INV OUT: 2602.87 8" PVC CONNECT TO �- - METER PIT p
EXIST. WATER w I PROP. RELOCATED W-
LINE w PROP. 6" FIRE LINE BUILDING B1 o I
- - - FIRE HYDRANT c
CONNECT TO
PROP.P. 8" WATER LINE - PROP. FIRE DEPT. I EXIST. WATER
ICONNECTION g I LINE
EX. 8" SSWR TO BE
REMOVED
PROP. 8" WATER
EX. 8" WATER TO LINE
BE REMOVED
BUILDING D I PROP. 20' WATER BUILDING A 0
EASEMENT PROP. 2" WATER 0 I PROP. 20' WATER
PROP. FIRE DEPT. EX. 8" WATER TO Fw _rw METER PIT I I EASEMENT
CONNECTION BE II REMOVED : i I �' III
I--w
0 .6 1 1 PROP. 8" WATER
CONNECT TO I PROP. FIRE DEPT.
LINE
PROP. ELEC. EXIST. WATER I CONNECTION
TRANSFORMER LINE L - o PROP. 6" FIRE LINE
0_ L_ EASMENT BUILDING B2 EX. 30' IRRIGATION
C PROP. SSWR CONN. o _ PROP. FIRE HYDRANT I
INV OUT:: 2\0 6" PVC _
� � � � �o„\� � -� - - - - - - - - -
° U DU DI
EX. FIRE HYDRANT ss_�i
TO BE BE RELOCATED ® - 8" CAD 0.40% �� � o\°u PROP. SSWR CONN.
\ io fw- o o\ou INV OUT: 2617.00 6" PVC CONNECT TO
�w Fw EXIST. WATER I
PROP. RELOCATED. w.. I ^�__ \ \ LINE _
FIRE HYDRANT 6" ® 17.10% l� �Y I�� �\ \� ' SE °u\W, DU DU - - - - - - -- - - - - - - - - - - - - - - - - -- - - _ _
�- DU U DU-DU-pU-DU-pU-
PROP. SSWR MH PROP. 20 SEWER o \ Du DU-ou-DL�
PROP. 2" WATER 8 ESMT. o - - - -
DU-DU- DU-DU-DU _
° PROP. 20' WATER 1 ou- _
RIM: 2620.40 ® p _ h� PROP. 20 SEWER EASEMENT \ -bu D -DU--DU
METER PIT INV IN: 2604.03 8" PVC 40y, ,� v�� \
I � \ � N o �\ ESMT. COMBINED WATER AND
PROP. SSWR CO INV OUT. 2604.03 8" PVC o PROP. ELEC.
N � ® o SSWR EASEMENT \
INV IN: 2607.23 6" PVC (n \\ \,� r O ou\ / TRANSFORMER EX. 8" WATER
INV OUT: 2607.23 6" PVC _ \ co o PROP. ELEC. LINE
CONNECT TO EXIST. PROP. 30 COMBINED PROP. SSWR MH o\°� TRANSFORMER PROP. SSWR CONN. n \ I 0
SANITARY WATER AND SSWR RIM: 2620.75� �\ O \ INV OUT. 2617.00 6" PVC \\\ \ i -w
EASEMENT \ INV IN: 2604.77 8" PVC '� o PROP. FIRE DEPT. C_ Fl"
\ o\ I
CONNECT TO � INV OUT: 2604.77 8" PVC � � � o CONNECTION \
N 2 \ BUILDING C
EXIST. WATER LINE o o \� // / 1 I
` 0 n IMPROVEMENTS
PROP. 20' WATER
\ � � 8" \ PROP. FIRE � � PROP. 2" WATER � \ \ � \ � UNDER SEPARATE
ESMT. ®
j Ospg\ HYDRANT 6�° METER PIT \ \ \ I PLAN AND PERMIT
PROP. SSWR MH
RIM: 2619.42 PROP. SSWR INV. \ss �/ PROP. ELEC.
® / TRANSFORMER
INV IN: 2603.63 8" PVC INV IN: 2604.86 8" PVC \
INV IN: 2603.73 8" PVC INV IN: 2604.86 6" PVC PROP. SSWR INV.\ 6 \"�► I o 0 0 \ \ I
INV OUT: 2603.63 8" PVC INV OUT: 2604.86 8" PVC INV IN: 2605.97 8" PVC �y o \ \\ EX. FIRE HYDRANT
M INV IN: 2605.97 6" PVC TO REMAIN 0 9" 0
\ INV OUT. 2605.97 8" PVC \ \ \ a0
PROP. \ \ CONNECT TO \ I PROP. 6" 0 D �
SS SS SS SS SS PROP. SSWR MH BLOW OFF \ \ Z
EXIST. WATER \ � w
RIM: 2621.04 \ " PROP. 8" LINE \ \ PROP. FIRE DEPT. FIRE LINE & I _j
INV OUT: 2606.00 8 PVC` WATER LINE fi Q
\ PROP. 6" w - - - \ \ METTER P. PITWA R 3 w
FIRE LINE u
CONNECT TO I
PROP. 8" WATER - EXIST. WATER
2 WATER _ \ LINE 0 PROP. 2" WATER LINE PROP. FF
EASEMENT \ �I METER PIT ;
- - - It
HYDRANTRE I
EX. SANITARY MANHOLE �� w w w
_ TO BE REMOVED a ss ss ss n ss ss n ss
- 8" 0 0.40% -r
- - - - _
\ PROP. SSWR MH I
RIM: 2621.96 - - -
On
INV IN: 2610.58 8" PVC PROP. SSWR MH
INV OUT: 2610.48 8" PVC RIM: 2623.35
INV OUT: 2611.47 8" PVC
PROP. 30' COMBINED
WATER AND SSWR
EASEMENT
EX. SSWR MH
INV IN: 2609.76 8" PVC
I �
UTILITY PLAN - C E N T R E PO I N T GRAPHIC SCALE IN FEET
0 20 40 80
Eagle & Ustick Meridian, ID May 10, 2024 NORTH