HomeMy WebLinkAboutPZ - Staff Report
Page 1
HEARING
DATE:
June 20, 2024
TO: Planning & Zoning Commission
FROM: Stacy Hersh, Associate Planner
208-884-5533
SUBJECT: Black Rock Coffee - CUP
H-2024-0011
LOCATION: 776 N. Cliff Creek Lane (Parcel
#R5711030040)
I. PROJECT DESCRIPTION
Conditional Use Permit request for a new 1,460-square foot coffee shop including a drive-through, parking,
and pedestrian access located within 300 feet of an existing drive-through facility, residential district, and
existing residence, on approximately 0.543 acres of land in the C-C zoning district.
II. SUMMARY OF REPORT
A. Project Summary
STAFF REPORT
COMMUNITY DEVELOPMENT DEPARTMENT
Description Details Page
Acreage 0.543 acres (Conditional Use Permit)
Future Land Use Designation Mixed Use Community
Existing Land Use Vacant/undeveloped
Proposed Land Use(s) Black Rock Coffee (restaurant with a drive-through)
Current Zoning C-C
Physical Features (waterways,
hazards, flood plain, hillside)
None
Neighborhood meeting date; # of
attendees:
3/21/2024
Description Details Page
History (previous approvals) H-2020-0099 AZ, DR, PP, PS, CUP (DA#2021-046525);
FP-2021-0013
Page 2
B. Community Metrics
Description Details
Ada County Highway
District
• Staff report (yes/no) Yes
• Requires ACHD
Commission Action
(yes/no)
No
Traffic Impact Study
(yes/no)
No
Access
(Arterial/Collectors/State
Hwy/Local) (Existing
and Proposed)
Access is proposed from N. Cliff Creek Lane (private street) via W. Pine Avenue
at the North boundary of the site.
C. Project Area Maps
Future Land Use Map
Aerial Map
Page 3
III. APPLICANT INFORMATION
A. Applicant:
Peggy Schinder, CSHQA – P2696 S. Colorado Blvd., Suite 525, Denver, CO 80222
B. Owner:
Tony Pallotta, Black Rock Coffee – 9170 E. Bahia Drive, Suite 101, Scottsdale, AZ 85260
C. Agent/Representative:
Same as Applicant
IV. NOTICING
Planning & Zoning
Posting Date
Newspaper Notification 6/4/2024
Radius notification mailed to
properties within 500 feet 5/30/2024
Public hearing notice sign posted
on site 5/24/2024
Nextdoor posting 5/30/2024
V. COMPREHENSIVE PLAN (HTTPS://WWW.MERIDIANCITY.ORG/COMPPLAN):
Land Use:
This property is designated Mixed Use Community (MU-C) on the Future Land Use Map (FLUM).
The purpose of this designation is to allocate areas where community-serving uses and dwellings are
seamlessly integrated into the urban fabric. The intent is to integrate a variety of uses, including
residential, and to avoid mainly single-use and strip commercial-type buildings. Non-residential
buildings in these areas tend to be larger than Mixed Use Neighborhood (MU-N) areas, but not as large
Zoning Map
Planned Development Map
Page 4
as in Mixed Use Regional (MU-R) areas. Goods and services in these areas tend to be of the variety that
people will mainly travel by car to, but also walk or bike to (up to three or four miles). Employment
opportunities for those living in and around the neighborhood are encouraged.
The subject site is among several commercially zoned properties surrounding the intersection of Ten
Mile and Pine Avenue. Numerous commercial establishments currently exist near the intersection, with
additional ones under construction directly to the south. The proposed use of a restaurant with a drive-
through aligns with the desired uses specified within the Mixed Use Community designation in the
Comprehensive Plan, as noted above. In conjunction with the already approved multi-family
development directly to the west and the currently approved and under-construction commercial, the
proposed use satisfies the general Mixed-Use Community future land use designation for this area. Staff
finds the proposed project is generally consistent with the Comprehensive Plan.
COMPREHENSIVE PLAN POLICIES (https://www.meridiancity.org/compplan):
Goals, Objectives, & Action Items: Staff finds the following Comprehensive Plan policies to be
applicable to this application and apply to the proposed use of this property (staff analysis in italics):
• “Require all new and reconstructed parking lots to provide landscaping in internal islands and along
streets.” (2.01.04B)
All parking lot landscaping is required to comply with the standards listed in UDC 11-3B-8C.
• “Permit new development only where urban services can be reasonably provided at the time of final
approval and development is contiguous to the City.” (3.01.01F)
City water and sewer service stubs have been provided to this site with the development of the
subdivision.
• “Plan for a variety of commercial and retail opportunities within the Area of City Impact.” (3.05.01J)
The proposed drive-through restaurant will contribute to the variety of uses and restaurant options
within this Area of the City.
• “Require pedestrian circulation plans to ensure safety and convenient access across large
commercial and mixed-use developments.” (3.07.02A).
A proposed 10-foot-wide pathway will be constructed from the building entrance, extending
through the drive-through connecting to the property to the south. Additionally, there is an
existing 10-foot-wide pedestrian pathway along N. Ten Mile Road, located on the west side of this
site, connects the commercial and multi-family developments.
• “Minimize noise, lighting, and odor disturbances from commercial developments to residential
dwellings by enforcing city code.” (5.01.01F)
Operation of the proposed use should comply with City ordinances pertaining to noise, lighting,
and odor disturbances.
VI. STAFF ANALYSIS
A. CONDITIONAL USE PERMIT (CUP)
Conditional use permit for a new 1,460-square foot coffee shop including a drive-through, parking, and
pedestrian access located on approximately 0.543 acres of land in the C-C zoning district to allow the
requested drive-through use within 300 feet of another drive-through facility, residential district, and
existing residence.
Page 5
Specific Use Standards (UDC 11-4-3):
The proposed use is subject to the following standards: (Staff’s analysis/comments in italic text)
Drive-Through Establishment: The proposed drive-through establishment is subject to the specific use
standards listed in UDC 11-4-3-11, Drive-Through Establishment. All establishments providing drive-
through service are required to identify the stacking lane, menu, and speaker location (if applicable), and
window location on the site plan. The site plan is also required to demonstrate safe pedestrian and
vehicular access and circulation on the site and between adjacent properties. At a minimum, the plan is
required to demonstrate compliance with the following standards: Staff recommends signage be
installed ahead of the southern crossing warning drivers to watch out for pedestrians.
1) Stacking lanes have sufficient capacity to prevent obstruction of driveways, drive aisles, and the
public right-of-way by patrons;
The proposed restaurant features a drive-through lane with space to queue 9 vehicles along with an
escape lane located on the west side of the site, outside of the drive-through lane. The drive-through
itself starts at the south side of the building and exits at the north side, facing W. Pine Avenue. The
concept plan also shows that the stacking lane is separate from the drive aisles and parking, which
allows for easy access to the rest of the development.
Staff recommends that the Applicant install additional signage and parking lot striping to clearly
mark and guide traffic safely throughout the site.
2) The stacking lane shall be a separate lane from the circulation lanes needed for access and parking,
except stacking lanes may provide access to designated employee parking.
The stacking lanes are separate lanes from the circulation lanes needed for access and parking.
3) The stacking lane shall not be located within ten (10) feet of any residential district or existing
residence;
The stacking lane is not located within 10’ of any residential district or residence.
4) Any stacking lane greater than one hundred (100) feet in length shall provide for an escape lane; and
The stacking lane exceeds 100’ in length and an escape lane is required. An escape lane is proposed on
the southeast side of the building (see site plan).
5) The site should be designed so that the drive-through is visible from a public street for surveillance
purposes.
The drive-through is located starting on the south side of the building and ending on the north side of the
building. The drive-through is visible from N. Ten Mile Road along the east side of the building for
surveillance purposes.
Based on the above analysis, Staff deems the proposed drive-through is in compliance with the specific
use standards as required.
Restaurant: The proposed use is also subject to the specific use standards listed in UDC 11-4-3-49
Restaurant, which requires at a minimum, one (1) parking space to be provided for every 250 square feet of
gross floor area (see parking analysis below). The Applicant did not provide information on how many
proposed indoor seats and patio seats will be provided to accommodate customers.
Page 6
Dimensional Standards (UDC 11-2):
Development of the site shall comply with the dimensional standards of the C-G zoning district in UDC
Table 11-2B-3. Staff has reviewed the proposed plans and building elevations and they comply with the
required standards.
Access (UDC 11-3A-3):
The site plan includes one access point from N. Cliff Creek Lane, a private street located on the western side
of the property. Vehicles will enter the site from the west, where they will have the option to park in the lot
in front of the building or proceed eastwards towards the 12’ drive-through lane and the pick-up window,
exiting back to the same drive aisle to the north. A second access is provided from a shared access with the
property to the south. An escape lane is also provided on the east side of the site, merging into the exit drive
aisle to the north. Direct access via N. Ten Mile Road is prohibited. The Applicant should provide a copy
of the recorded cross-access/ingress-egress easement with adjoining properties to the south [parcel
#R5711030060] to the Planning Division with the future CZC and Design Review Application in
accordance with the provisions of UDC 11-3A-3A2.
Parking (UDC 11-3C):
A minimum of one (1) off-street parking space is required per 250 square feet (s.f.) of gross floor area. Based
on the 1,460-square-foot restaurant, a minimum of 6 parking spaces are required. A total of 13 parking
spaces are proposed, exceeding UDC standards.
A minimum of one (1) bicycle parking space must be provided for every 25 vehicle spaces or portion thereof
per UDC 11-3C-6G; bicycle parking facilities are required to comply with the location and design standards
listed in UDC 11-3C-5C. Bicycle parking is depicted on the plans submitted with this application that meet
the requirements. A detail of the bicycle racks shall be provided on the plans submitted with the future
Certificate of Zoning Compliance and Design Review Application.
Pedestrian Walkways (UDC 11-3A-19):
The proposed plan includes a pedestrian walkway from the main walkway in front of the building connecting
to the building residing to the south across the drive-through lanes. Where pedestrian walkways cross
vehicular driving surfaces, they’re required to be distinguished from the vehicular driving surface through
the use of pavers, colored or scored concrete, or bricks as set forth in UDC 11-3A-19B.4. The site/landscape
plan submitted both reflect compliance with this standard – stamped concrete is proposed.
Landscaping (UDC 11-3B):
Street buffer: The street buffer along N. Ten Mile Road and W. Pine Avenue was constructed with the
improvements for the Mile High Pines development for the common area site improvements. Staff
recommends that the Applicant protect the existing landscape buffers and trees per UDC 11-3B-10. The
landscape planter adjacent to the buffer along the northwest side of the drive aisle entrance/exit should
incorporate shrubs and rock mulch (reference figure below). Staff recommends that the Applicant
submit a revised landscape plan with the future CZC application.
Page 7
Parking lot: Interior parking lot landscaping shall be required on any parking lot with more than twelve
(12) spaces. Landscape planters shall contain a minimum of fifty (50) square feet, and the planting area
shall not be less than five (5) feet in any dimension, measured inside curbs. The only exception to the five-
foot minimum dimension is at the tip of triangular planters located at the end of rows of angled parking.
Each interior planter that serves a single row of parking spaces shall be landscaped with at least one (1)
tree and shall be covered with low shrubs, lawn, or other vegetative ground cover. Each interior planter
that serves a double row of parking spaces shall have at least two (2) trees and shall be covered with low
shrubs, lawn, or other vegetative ground cover. Trees shall be centered within the planters and provide
urban canopy. Deciduous urban canopy trees shall be pruned to a minimum height of eight (8) feet above
the adjacent parking areas. Evergreen trees and class III trees are prohibited in interior planters. The
planter islands appear sparse. The required landscape areas shall be at least seventy (70) percent
covered with vegetation at maturity, with mulch used under and around the plants in accordance with
UDC 11-3B-5.
Outdoor Lighting (UDC 11-3A-11):
All outdoor lighting is required to comply with the standards listed in UDC 11-3A-11C. Light fixtures that
have a maximum output of 1,800 lumens or more are required to have an opaque top to prevent up-lighting;
the bulb shall not be visible and shall have a full cutoff shield in accord with Figure 1 in UDC 11-3A-11C.
Staff recommends that the Applicant provide details of the lighting that demonstrate compliance with the
standards listed in UDC 11-3A-11 with the future CZC application submittal.
Mechanical Equipment (UDC 11-3A-12):
All mechanical equipment on the back of the building and outdoor service and equipment should be
incorporated into the overall design of buildings and landscaping so that the visual and acoustic impacts of
these functions are fully contained and out of view from adjacent properties and public streets as set forth in
UDC 11-3A-12. If mechanical equipment is proposed to be roof-mount, all equipment should be screened
and out of view as noted above.
Page 8
Building Elevations (UDC 11-3A-19 | Architectural Standards Manual):
Conceptual building elevations were submitted for the proposed structure as shown in Section VII.C.
Building materials consist of western rib metal panels, western wave metal wall panels, woodstone Hardie
lap siding, parapet metal wall cap flashing, and glazing.
The proposed conceptual elevations are not approved. Final design is required to comply with the
Architectural Standards Manual for Commercial Design Guidelines.
Certificate of Zoning Compliance (UDC 11-5B-1):
A Certificate of Zoning Compliance (CZC) is required to be submitted for approval of the site and building
design prior to submittal of building permit applications.
VII. DECISION
A. Staff:
Staff recommends approval of the Conditional Use Permit per the provisions included in Section IX in
accord with the Findings in Section X.
Page 9
VIII. EXHIBITS
A. Site Plan (date: 5/20/24)
Page 10
B. Lanscape Plan (date: 3/29/24)
Page 11
C. Black Rock Coffee Proposed Elevations
Page 12
Page 13
IX. CITY/AGENCY COMMENTS & CONDITIONS
A. PLANNING DIVISION
Conditional Use Permit:
1. Future development of this site shall comply with the previous conditions of approval and terms of
the existing Development Agreement and the conditions contained herein [H-2020-0099 AZ, DR,
CUP, PP, PS (DA#2021-046525); FP-2021-0013].
2. The site/landscape plans shall be revised as follows:
a. All mechanical equipment on the back of the building and outdoor service and equipment areas
should be incorporated into the overall design of buildings and landscaping so that the visual and
acoustic impacts of these functions are fully contained and out of view from adjacent properties
and public streets as set forth in UDC 11-3A-12.
b. Additional signage and parking lot striping are required throughout the site to efficiently and
adequately direct patrons to the menu boards and throughout the site with minimal conflict.
c. Install additional signage ahead of the southern crossing warning drivers to watch for
pedestrians.
d. Incorporate shrubs and rock mulch in the landscape planter adjacent to the buffer along the
northwest side of the drive aisle entrance/exit in accordance with UDC 11-3B-8C.
e. The required landscape areas within the planters shall be at least seventy (70) percent covered
with vegetation at maturity, with mulch used under and around the plants in accordance with
UDC 11-3B-5.
f. Provide a copy of the recorded cross-access/ingress-egress easement to adjoining properties to
the south [parcel #R5711030060] to the Planning Division with the future CZC and Design
Review application in accordance with the provisions of UDC 11-3A-3A2.
3. The existing landscaping buffers along N. Ten Mile Road and W. Pine Avenue shall remain in place
and shall be protected during construction on the site per UDC 11-3B-10.
4. Compliance with the standards listed in UDC 11-4-3-11– Drive-Through Establishment and
standards listed in UDC 11-4-3-49 – Restaurant is required.
5. Direct access via S. Ten Mile Road and W. Pine Avenue is prohibited.
6. A Certificate of Zoning Compliance and Design Review application shall be submitted and approved
for the proposed use prior to submittal of a building permit application. The design of the site and
structure shall comply with the standards listed in UDC 11-3A-19; the design standards listed in the
Architectural Standards Manual and with the Development Agreement.
7. The conditional use permit is valid for a maximum period of two (2) years unless otherwise
approved by the City. During this time, the Applicant shall commence the use as permitted in accord
with the conditions of approval, satisfy the requirements set forth in the conditions of approval, and
acquire building permits and commence construction of permanent footings or structures on or in the
ground as set forth in UDC 11-5B-6. A time extension may be requested as set forth in UDC 11-5B-
6F.
B. PUBLIC WORKS
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=346087&dbid=0&repo=MeridianCity
Page 14
C. FIRE DEPARTMENT
No comments were submitted.
D. POLICE DEPARTMENT
No comments were submitted.
E. KUNA SCHOOL DISTRICT
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=346103&dbid=0&repo=MeridianCity
F. IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY (DEQ)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=346723&dbid=0&repo=MeridianCity
G. VALLEY REGIONAL TRANSIT
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=346195&dbid=0&repo=MeridianCity
H. NAMPA & MERIDIAN IRRIGATION DISTRICT (NMID)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=348393&dbid=0&repo=MeridianCity
I. ADA COUNTY HIGHWAY DISTRICT (ACHD)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=346344&dbid=0&repo=MeridianCity
J. IDAHO TRANSPORTATION DEPARTMENT (ITD)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=346116&dbid=0&repo=MeridianCity
X. FINDINGS
A. Conditional Use Permit (UDC 11-5B-6E)
The Commission shall base its determination on the Conditional Use Permit requests upon the following:
1. That the site is large enough to accommodate the proposed use and meet all the dimensional and
development regulations in the district in which the use is located.
Staff finds that the subject property is large enough to accommodate the proposed use and dimensional
and development regulations of the C-C district (see Analysis, Section VI for more information).
2. That the proposed use will be harmonious with the Meridian Comprehensive Plan and in accord with the
requirements of this Title.
Staff finds the proposed restaurant with a drive-through will be harmonious with the uses allowed in the
Comprehensive Plan and is consistent with applicable UDC standards with the conditions noted in
Section IX of this report.
3. That the design, construction, operation and maintenance will be compatible with other uses in the
general neighborhood and with the existing or intended character of the general vicinity and that such
use will not adversely change the essential character of the same area.
Staff finds the design, construction, operation and maintenance of the proposed use will be be
compatible with other uses in the general neighborhood, with the existing and intended character of the
vicinity and will not adversely change the essential character of the area.
Page 15
4. That the proposed use, if it complies with all conditions of the approval imposed, will not adversely
affect other property in the vicinity.
Staff finds that if the applicant complies with the conditions outlined in this report, the proposed use will
not adversely affect other property in the area.
5. That the proposed use will be served adequately by essential public facilities and services such as
highways, streets, schools, parks, police and fire protection, drainage structures, refuse disposal,
water, and sewer.
Staff finds the proposed use will be served by essential public facilities and services as required.
6. That the proposed use will not create excessive additional costs for public facilities and services and
will not be detrimental to the economic welfare of the community.
Staff finds the proposed use will not create additional costs for public facilities and services and
will not be detrimental to the economic welfare of the community.
7. That the proposed use will not involve activities or processes, materials, equipment and
conditions of operation that will be detrimental to any persons, property or the general welfare by
reason of excessive production of traffic, noise, smoke, fumes, glare or odors.
Staff finds the proposed use will not be detrimental to any persons, property or the general welfare by
the reasons noted above.
8. That the proposed use will not result in the destruction, loss or damage of a natural, scenic or
historic feature considered to be of major importance. (Ord. 05-1170, 8-30-2005, eff. 9-15-2005).
Staff finds the proposed use will not result in the destruction, loss or damage of any such features.