HomeMy WebLinkAboutC2-1 - UTILITY PLAN N S
Studio
0 20 40 60 306 NE 2nd Street
Plan/Profile Scale: 1" = 20' Meridian, ID 83642
208-649-8306
www.studioharchitects.com
WATER KEYNOTES #w
1. INSTALL
1 — FIRE HYDRANT PER CITY OF MERIDIAN STANDARD
DETAIL "W8"
THRUST BLOCKING STAMP:
2. INSTALL
1 — 2" WATER SERVICE CONNECTION WITH 2" WATER S�ONAL £N
METER PER CITY OF MERIDIAN SUPPLEMENTAL DRAWING �pFS,\ ST£R�.
5 LF 2" WATER SERVICE. Q40
—w
3w w w w w w w w " w w 3. INSTALL 11
ww� w w w w w w w w w w o
3 1 — 8" x 6" TEE
1 — 6" GATE VALVE Q
8"s S 1"S 18"s 18"s i 8"s i 8"s i 8"s i 8"s i s— i 8"s 8"s 18"s i 8"s i 8"s i 8"s i 8"s i 8"s 18"s 18"s THRUST BLOCKING lF O V. \O
4. INSTALL F<<Y KEN��'�
°° W. FRANKLIN RD. THRUST BLOCKING 1 -19-24
0 Lw_
5. INSTALL
a a 1 — 8" x 6" REDUCER
n ° n a ° n FO° FO ° FO 4 FO as F FQ FO f� a° FO Fo Fo i 1 — 6" "JURISDICTIONAL" GATE VALVE CONSULTANT:
1 — 6" 22.5` ELL
P P � a iRR a " 1 R _ T T T- THRUST BLOCKING
r 25 LF 6" _ 6. INSTALL
C900
3 ° _ _ " i — 1 — 6" 45° ELL
FIRE SERVICE THRUST BLOCKING.
°° °
6„Pi EGG — 1Pi �— - - — — — ___- - =__-}- -
G
GAG _ _ _ _ 7. MAINTAIN 18" VERTICAL SEPARATION BETWEEN
POTABLE/NON—POTABLE MAINS/SERVICES PER CITY OF
40 LF 2" POLY 01. MERIDIAN WATER NOTE #2 SHEET CO.0 AND DEQ
°
— e ° _f s 8W WATER SERVICE ° No ° I STANDARDS. INSTALL VERTICAL BENDS IN WATER E N G I N E E RI N G
�s o 3PI '° ° 5W 1 I MAINS/SERVICES IF NECESSARY. 5725 NORTH DISCOVERY WAY
'00I m� BOISE, IDAHO 83713
RR I I ° a ° 8 LF 6" C900 6W ° s \ ° 8. SEE PLUMBING FOR CONTINUATION AND BACKFLOW PHONE(208)639-6939
6"Pi 6' 1 I ° 9W FIRE SERVICE ° 61. I PREVENTION. kmengllp.com
«
I II I , <° N
a \ I I 9. SEE FIRE FOR CONTINUATION AND BACKFLOW
y I i N x a x�x d o1 ° \ ,� i I PREVENTION. REVISIONS
o
ADJUST ELECTRICAL 1 � a 1, ° ° \ 10. DEMO AND REMOVE TEMPORARY BLOW—OFF. CONNECT No. Description Date
L VAULT TO FG GRADE �� J ° ° I TO EXISTING 8" WATER MAIN STUB. CONTRACTOR TO
— —I— I a 2w a 1 W I POTHOLE AND VERIFY WATER STUB SIZE PRIOR TO ANY
NZ
I o 1 1• a \ I CONSTRUCTION.
00 A - I o �o c� a \ \ I 11. INSTALL
3 1 — 6" 90° ELL
°0 ° 15 LF 4" PVC 26 LF 8" C900 0 ,n 4W I THRUST BLOCKING
I m S SEWER SERVICE 3S WATER MAIN o s \ I CONNECT TO EXISTING 6" FIRE MAIN. CONTRACTOR TO
I rx ® 12.5% a \ I POTHOLE AND VERIFY SIZE AND LOCATION PRIOR TO
00 ° I a ° IE 2580.83 a a " I I ANY CONSTRUCTION.
I;tO °s ° ° A ° I ® � I 20 LF 1" PVC O
z °° 1 `° L ° FINISH FLOOR ° I PRESSURE IRRIGATION 2PI
40 LF 4" PVC a I o I R SERVICE. CONNECT TO EXISTING
-00 cn
° SEWER SERVICE ° sco'4"s 44 ELEVATION a I I �, _ d SERVICE STUB.
@ 12.5% o s ° 2583.50 z I W
o 2s ° o s ° I I 0 1 3PI SEWER KEYNOTES #s
00
z I S a 105 LF 8" C900 1. CONNECT TO EXISTING 6" SEWER SERVICE STUB.
S I / ° ° 4 �° WATER MAIN I CONTRACTOR TO POTHOLE AND VERIFY SEWER STUB
O I +� ° a °a a ,a a ° S I I a LOCATION, SIZE, AND ELEVATION PRIOR TO ANY
CONSTRUCTION.
° ° I % � I I N I RR IE 6" STUB = 2574.40t
toL 7W I o I IE 4" PROPOSED = 2574.48
° m 4"SD 4"SD "SD 4"SD �° I I I �
v 6„s "s� I 6 do ISao s"sD s"sD s D s"sD SD 6"sD — 3PI a 2. INSTALL 4" TRAFFIC RATED CLEAN—OUT WITH BRASS CAP
—�--s" ® i2"sD I W 34 LF 1" PVC LID PER ISPWC SD-506A.
2P1
xx 20.00' CITY ° PRESSURE IRRIGATION
3 I is I I SERVICE. CONNECT TO EXISTING
OF MERIDIAN N 3. SEE PLUMBING FOR CONTINUATION.
WATER MAIN EASEMENT ( I SERVICE STUB.
° v
1 I to I No I I
co °
I
00
°s 1
Jill K a I 1 PRESSURE IRRIGATION KEYNOTES #W
N G I � a I o I w 0
o0 1. PRESSURE IRRIGATION POINT OF CONNECTION — SEE
3 i 1 7W i LANDSCAPING.
a �
00
127SD z I I W PRESSURE IRRIGATION NOTES
00
12"s�� I
° 0
12"so co 127so 1 I . PRESSURE IRRIGATION IS SUPPLIED BY THE
HOMEOWNERS ASSOCIATION. BACKUP SOURCE IS
® ss° 12sD— S 10W PROVIDED BY DOMESTIC WELL AS PART OF THE TM
II W
N a 4 I SYSTEM.CENTER SUBDIVISION MASTER PRESSURE IRRIGATION
00 R s"SD s"sD 4 LF 6" C900 s"SD s"SD s"sD FIRE MAIN
a
—
- - - — — - - - � ° - - - - - L - - c _ _ - - - - - - - 2. CAP AND MARK SERVICE STUB.
r - - - - - - - - - - - - - — - - - -� - - - - -
c c 00 3P1 ° c c�c c c c c c c c c c c c c c c c c— 3. INSTALL 4" TRAFFIC RATED LIDS OVER EXISTING
TP N TP T TP P ° P TP TP— Tr TP TP TP TP o T' TP TP TP TP TP TP TP TP TP TP TP PRESSURE IRRIGATION VALVES PER ISPWC SD-506A.
8"W
-- -- 1 111 5W
— — $"yr—
P P P CONTRACTOR TO COORDINATE WITH UTILITY
, COMPANY TO RELOCATED VAULT OUTSIDE `J
OF PROPOSED PIED RAMP —
—8"s 8"s S W. PEAK CLOUD LN.
EP EP EP— EP EP EP EP EP EP P \
—EP� \
\ cp, v
oo,
s
00mw*4
a
IL
y
Q
Z
C Q
J y J
C • N
Z
W IL � coyc))
0 �
Q N � � _
IL S ix � a W
a 0 �
� z
_ a
w w vj LU
LU LU
w W o LU
x
O w/ a a co
PROJECT NUMBER 23-230
SHEET ISSUE DATE 1/19/24
SUBMITTAL BUILDING PERMIT
SHEET
C2 . 1