Loading...
HomeMy WebLinkAboutCC - Staff Report for 2-27 STAFF REPORT E COMMUNITY N -- COMMUNITY DEVELOPMENT DEPARTMENT HEARING 2/27/2024 0 DATE: Legend �Pmiect Location o g TO: Mayor&City Council z a FROM: Stacy Hersh,Associate Planner ��,E PUFFIN ST h N n os 208-884-5533 EMASTIFF ,n i -ST c --------------- SUBJECT: Nine Mile Creek Bungalows Z SHP-2023-0003 m p - -E BEAG LOCATION: 2055 S. Locust Grove Road.,in the SE 1/4 of the SE 1/4 of Section 19,T.3N.,R.IE. F� E BLUE TIC I H n E GRIFFON u p ST _ tA--- - I. PROJECT DESCRIPTION Short plat to subdivide an existing residential lot(S1119141856), consisting of 1.34 acres of land, into four(4)building lots,one(1) common driveway lot, and one(1)common lot in the R-4 zoning district. IL APPLICANT INFORMATION A. Applicant: Robyn Shea, Owner.— 12316 N. Humphreys Way,Boise,ID 83714 B. Owner: Same as Applicant C. Representative: Same as Applicant III. NOTICING City Council Posting Date Legal notice published in newspaper 2/11/2024 Radius notice mailed to property owners within 500 feet 2/10/2024 Posted to Next Door 2/15/2024 Page 1 IV. STAFF ANALYSIS The short plat proposes to further subdivide parcel#Sl 119141856,consisting of 1.34 acres of land, into four(4)building lots, one(1) common driveway lot, and one(1)common lot in the R-4 zoning district. The proposed density of 2.99 units per acre is consistent with the density desired of 3 to 8 dwelling units per acre in the Medium Density Residential Future Land Use Map designation for this site. The proposed lots comply with the dimensional standards listed in UDC Table 11-2A-6 for the R-4 zoning district. Existing structure: The existing home is connected to City water and sewer service and is proposed to remain on Lot 1,Block 1. The detached garage/shop and accessory structure on Lots 2 and 3 are proposed to be removed upon development of the subdivision. Additionally,the carport for the existing home is proposed to be removed to comply with the rear setback. Once the carport and the detached garage are removed the existing home would not meet the required number of off-street parking spaces.Per UDC Table 11-2A-5, a four-bedroom home must provide four(4)parking spaces, at least two (2)in an enclosed garage, other spaces may be enclosed or a minimum 20-foot by 20-foot parking pad. By removing the required parking from the property, a CUP may be required per the non- conforming regulations set forth in UDC 11-04, unless the existing garage is retained.At a minimum, staff recommends that the applicant retain the existing carport and install the required parking pad so that in the future a garage could be constructed to avoid having to obtain CUP approval for any expansion. This requires some of the lot lines on the plat to be adjusted to accommodate the carport prior to City Engineer's signature on the plat. Easements: The plat is missing the required public utility, irrigation, and drainage (PUDI) easements for each lot(5-feet along interior lot lines and 10-feet along the perimeter and rear lot lines). Additionally,the consecutive numbering of all lots in each block, including the common lots, should be included. The common lot depicted on the north encompasses the easement for the Nine Mile Creek on a portion of this property. Staff recommends that the proposed 25-foot easement for the landscape buffer along the Locust Grove Street frontage terminate at the shared property line of Lot 4, Block 1, and the northern common lot(refer to the figure below). Access: Access to this property is provided via a driveway from S. Locust Grove Road,which will be platted as a common lot for a common driveway that will provide access to all lots in the proposed subdivision. Direct access via S. Locust Grove Road is prohibited. The Fire Department has approved the design of the proposed common driveway which shall be signed"No Parking Fire Lane"per the Page 2 2108 IFC. A common driveway exhibit that reflects compliance with the standards listed in UDC II-6C-3D was not submitted. The Applicant should submit a common drive exhibit that depicts setbacks,fencing,building envelope, and orientation of the lots and structures, including the existing home on Lot 1,Block 1 prior to City Engineer's signature on the plat. Road improvements: ACHD recently completed the widening of S. Locust Grove Road, incorporating a new 10-foot wide pathway adjacent to this site and a 30' curb cut into this site. No additional roadwork is required for this project. Landscaping: A twenty-five-foot landscape buffer is required along S. Locust Grove Road in accordance with UDC 11-3B-7. There is existing landscaping(i.e.trees)to remain and eight(8)new trees are proposed to be planted with rock mulch. All required landscape buffers along streets shall be designed and planted with a variety of trees, shrubs, lawn, or other vegetative ground cover. Plant materials in conjunction with site design shall elicit design principles including rhythm, repetition,balance, and focal elements. Staff recommends that the Applicant include a variety of shrubs along with the trees within the planters along S. Locust Grove Road (refer to figure below). The 25-foot wide landscape buffer area north of the driveway should comply with these standards for landscaping and requires a license agreement for NMID for any landscape in their easement. The open space standards allow natural waterways that intersect, cross, or lie within the developed area to remain unimproved per UDC 11-3G-5B.1. FIGURE 1 �I i The landscape plan specifies that the use of"weed fabric is not recommended". If rock mulch is used, a weed barrier fabric shall be used beneath the rock in accordance with UDC 3B-3.H. Impermeable plastic weed barriers are prohibited because they restrict water and oxygen to the plants.Within stormwater facilities, mulch may not float. Staff recommends that the Applicant install a weed barrier fabric beneath rock mulch as required by the UDC code. Page 3 There are a few existing trees on this site, of which two(2)are proposed to be removed.A mitigation plan was not submitted;however,the landscape plan included in Section VI.B, depicts existing trees that are proposed to be removed vs. retained. Mitigation should be proposed on the landscape plan in accordance with the standards listed in UDC 11-3B-10C.S. The Applicant should provide a description outlining how existing trees to be retained are to be protected during construction. Furthermore,the landscape plan is missing a calculation table for project components, necessary for demonstrating compliance with the UDC requirements. There is no fencing proposed with this application. The Applicant is responsible for constructing fences abutting common open space lots to distinguish common from private areas,particularly adjacent to the Nile Mile Creek, to enhance safety. Staff recommends installing an open vision or semiprivate fence up to six(6)feet in height, along the northern common lot in accordance with UDC 11-3A-7A.7.b. Staff has reviewed the proposed short plat for compliance with the criteria set forth in UDC 11-6B-5 and deems the short plat in compliance with said requirements. V. DECISION Staff recommends approval of the proposed short plat with the conditions noted in Section VII of this report and in accord with the findings in Section VIII. Page 4 VI. EXHIBITS A. Short Plat(date: 02/07/2023) PRELIMINARY PLAT 5HOW)NG FnR MNE ivS[LE CREEK BUNGALOWS r .: Y `- r MEW 7 NINE MILE CREEK BUNGALOWS cxRnmrArr•!u!]WHIRS rrxnPrcnrc oP AIRl'll'OR courrn nrroanrRs cxenrlcArr: .,LLmi.rew-well wi-e.xuiamiuc.na..rur s" I r�sT' APPl M. AnA CD11MY COMMmow.m s � aoxnovo�c�uc nc�o.�o><w ,� �1� ^~ r..c n....r*. CPAi1S1C.IT[OT CIX1Nry nUAA1RP11 - A1.nLSfR 1 PAl.TI f CSRT CAnf ews w.ni..irw r,.vxm,ucc:iar¢r: ^x.w.w.wsscwrx 'ffi'f �P� �.cruarxr unrmm-rc�xrrcamnoawm �g�s ��"s APPR(1VA1..1 RfiA CCfllhlV][[I:I fN'.RY nCSTA]CT cwxn iir..wn,ocmc+c"�csawnir a.a �. .m,x rir s,rsc�sw rsr�rxrx 9 �ilTF1r�LTT Of COIMiI'W Rl'F.l'O9! ACN FA]W IlnGNPNi .�. }y. '11MRI:RLIR4: wry.. . ulxvi:"NG Page 5 B. Landscape Plan(dated: 12/13/2023) � � z � a w { �Z w A-w9w9mim �Z Page 6 C. Aerial Map&Elevations of Existing Home i 2055 S LOCUST GROVE F X Show search results for 2055 5... Nnertrle Leek I MR R � i � E LAIS DR Y t+'r Page 7 f�- r': VII. CITY/AGENCY COMMENTS&CONDITIONS A. Planning Division Site Specific Conditions: 1. If the City Engineer's signature has not been obtained within two(2)years of the City Council's approval of the short plat,the short plat shall become null and void unless a time extension is obtained,per UDC 11-6B-7. 2. The short plat prepared by Timberline Surveying on 2/7/2023,included in Section VI.A, shall be revised as follows: a. Revise Note#2: "Building setbacks and dimensional standards in this subdivision shall be in compliance with the applicable zoning regulations of the City of Meridian." b. Note#5: Lots shall not be reduced in size without prior approval from the health authority and the City of Meridian. c. Note#8: Include the recorded instrument number of the CC&R's. d. Remove Note#9 e. Add Note#10: "Lot 5,Block 1,is designated as a common drive lot to be owned and maintained by the Homeowners' Association. Lot 5 will provide ingress/egress to all the lots within Nine Mile Creek Bungalows. The common drive shall have a paved surface capable of supporting fire vehicles and equipment." f. Add Note#11: Direct lot access via Locust Grove Road is prohibited. g. Depict the required PUDI easements for(each 5-feet along interior lot lines and 10-feet along the perimeter and rear lot lines) h. Add Note#12: Specify who is to own and maintain the northern common lot. i. Modify the plat to readjust the 25-foot landscape buffer along the street frontage. j. Graphically depict the Nile Mile Creek easement on the plat. k. Adjust the lot lines to accommodate the carport on Lot 1,Block 1 to ensure compliance with the rear setback requirements for the existing home. 1. Depict the Land Surveyor's signed seal on the plat. 3. Prior to signature on the plat,the landscape plan shall include the following revisions: a. Mitigation shall be required for all existing trees four-inch caliper or greater that are removed from the site with equal replacement of the total calipers lost on site up to an amount of one hundred(100)percent replacement per UDC 11-3B-1OC.5 b. Revise the landscape plan to include a variety of shrubs along with the trees within the landscape buffer along S. Locust Grove Road in accordance with UDC 11-313-7. c. Install a weed barrier fabric beneath the rock mulch in accordance with UDC 11-313-3H. d. Install fencing along the common lot adjacent to the Nile Mile Creek and remove any prohibited fencing in accordance with UDC 11-3A-7. 4. Future development shall comply with the dimensional standards listed in UDC Table 11-2A- 5 for the R-4 zoning district and the common driveway standards listed in UDC 11-6C-3D. Additionally,the Applicant shall submit a common drive exhibit that depicts setbacks, Page 9 fencing,building envelope,and orientation of the lots and structures for the future homes, including the existing home on Lot 1,Block 1 prior to City Engineer's signature on the plat 5. As a result of the non-conformity to the existing home due to the off-street parking requirements in UDC 11-3C-6,the Applicant/Owner is required to apply for a Conditional Use Permit for any future expansions on the property. Additionally,the existing carport shall be retained and the Applicant shall install the required parking pad in accordance with UDC 11-3C-6. 6. Once the plat records,the existing home may require a new address. 7. All existing structures that don't comply with the minimum dimensional standards listed in UDC Table 11-2A-5 for the R-4 zoning district shall be removed prior to signature on the final plat by the City Engineer. 8. The Applicant shall secure a license agreement with NMID for landscaping within the Nile Mile Creek easement. 9. Staff s failure to cite specific ordinance provisions or conditions from the previous approvals noted above does not relieve the Applicant of responsibility for compliance. B. Public Works https://weblink.meridiancity.orglWebLinkIDocView.aspx?id=330915&dbid=0&repo=MeridianC ity C. Fire Department https://weblink.meridianciU.or lWebLink/DocView.aspx?id=330945&dbid=0&repo=MeridianC hty D. Idaho Transportation Department(ITD) https:11weblink.meridianciU.or,g/WebLink/DocView.aspx?id=331977&dbid=0&r0o=MeridianC hty E. Idaho Department Of Environmental Quality https://weblink.meridianciU.or,glWebLinkIDocView.aspx?id=331967&dbid=0&repo=MeridianC ky F. Ada County Highway District(ACHD) https://weblink.meridiancity.org/WebLinkIDocView.aspx?id=334303&dbid=0&repo=MeridianC iv VIII. REQUIRED FINDINGS FROM THE UNIFIED DEVELOPMENT CODE In consideration of a short plat,the decision-making body shall make the following findings: A. The plat is in conformance with the Comprehensive Plan and is consistent with the Unified Development Code; The Comprehensive Plan designates the future land use of this property as Medium Density Residential and the current zoning district of the site is R-4. Staff finds the proposed short plat complies with the short plat standards listed in UDC 11-6B-5. B. Public services are available or can be made available and are adequate to accommodate the proposed development; Page 10 Staff finds that public services will be provided and are adequate to serve the proposed lots. C. The plat is in conformance with scheduled public improvements in accord with the City's capital improvements program; Staff finds all required utilities will be provided with lot development at the developer's expense. D. There is public financial capability of supporting services for the proposed development; Staff finds that the development will not require major expenditures for providing supporting services as services are already being provided in this area. E. The development will not be detrimental to the public health, safety or general welfare; and Staff finds the proposed development will not be detrimental to the public health, safety or general welfare. F. The development preserves significant natural,scenic or historic features. Staff is not aware of any significant natural, scenic or historic features associated with short platting the structure on this site. Page 11