Loading...
HomeMy WebLinkAboutC400 Site Plans [11-23-23] ;," lei !�U rt�e rf0 -'_-•yd{"d u',-:., -ay:-� �a' ' 1M"� ..:':�r LE END N N N PROPERTY LINE co CD CD CD M SETBACK LINE - ~ — — — — — — — — DRAINAGE AND UTILITY EASEMENT cN � - � CD CD , 1' ., a —x—x—x—x—x— PROPOSED FENCE E AMITY ROAD PROPOSED CURB AND GUTTER, PER ISPWC SD-701 71, STANDARD DUTY ASPHALT PAVMENT SEE DETAILS FOR SECTION cn I I I RIGHT OF WAY PAVEMENT F PROJECT LOCATION — � _ _ SEE DETAILS FOR SECTION i . I I I i i _ '� � � w A �°° a a ° ° HEAVY DUTY CONCRETE PAVEMENT W Z SEE DETAILS FOR SECTION w Lu Lu I d rt w a �R CONCRETE SIDEWALK 0 W INSTALL PER ACHD SD-709,SEE DETAILS FOR SECTION U z I I I � _ <b, 0 � >. I STORM WATER AREA >_ W ID k I EXC. 18 & r SEE GRADING PLAN FOR DETAILS IL Y I i I EXC. 19 SITE PLAN NOTES as M Z \ I I = 1. REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF STOOPS,TRASH ENCLOSURES,&PRECISE BUILDING I DIMENSIONS.REFER TO THE SITE ELECTRICAL PLAN FOR LOCATIONS OF PROPOSED LIGHT POLES,CONDUITS,AND ELECTRICAL EQUIPMENT. � \VI I I II I I \� I*.T.:sr.A�R•��''re- I arm:.�+r-t; _ Fee Sp�..,rE.rr �'�.,.:. a.,i ., � � I e9•1522•E azo.°o• 2. REFER TO CERTIFIED SITE SURVEY OR PLAT FOR EXACT LOCATION OF EXISTING EASEMENTS,PROPERTY BOUNDARY DIMENSIONS,AND ----—SDCB (COVERED) — — — VICINITY MAP ADJACENT RIGHT-OF-WAY&PARCEL INFORMATION. _ _ I RIM=2684.49' I I 11 N.T.S. I 3. DIMENSIONS AND RADII ARE DRAWN TO THE FACE OF CURB, UNLESS OTHERWISE NOTED.DIMENSIONS ARE ROUNDED TO THE NEAREST L - - - - - - - - - - - - - - - - - - - - - - - - I I - - - - - SMH� TENTH FOOT,AND AREAS ARE ROUNDED TO THE NEAREST SQUARE FOOT. ell Ln I - -I- - - - - — INV. 8" PVC 4. UNLESS OTHERWISE NOTED,THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING EXISTING SITE IMPROVEMENTS THAT CONFLICT U) W=2670.26' — — — — _ WITH THE PROPOSED WORK, INCLUDING BUT NOT LIMITED TO TRAFFIC SIGNS, LIGHT POLES,ABOVEGROUND UTILITIES, ETC. PERFOR Lu M - 1� - -I L — _---- - - - - - - - - - - - - - - - - - - - - - - — — — — — — — — — — — — — — — L — WORK IN ACCORDANCE WITH GOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS. COST SHALL BE Q Q / ILLEGIBLE — — — — — — ' ___— _ — — — — —E=2670�30' — — — — _ _ INCLUDED IN BASE BID. REBAR AND CAP \ o ° o POINT OF BEGINNING G 5. TYPICAL PARKING STALL DIMENSIONS SHALL BE 9.0-FEET IN WIDTH AND 19-FEET IN LENGTH UNLESS OTHERWISE INDICATED. o (n Of PRIVATE DRIVE o a '�,, - I �I I I I I , CD 0 I ILLEGIBLE I I� I I I I I 6. MONUMENT SIGN(S)ARE DETAILED ON THE ARCHITECTURAL PLANS AND ARE SHOWN FOR GRAPHICAL&INFORMATIONAL PURPOSES ONLY. Q c is — — Q _ _ Lu PVC .� — CONTRACTOR TO VERIFY SIGN DIMENSIONS, LOCATION AND REQUIRED PERMITS WITH THE OWNER. Z jco C — � (n bi 2 7. CONTRACTOR TO VERIFY EXISTING IMPROVEMENTS SHOWN ON THE PLAN. 3z H O Y I GRAY P C UBS C4 w = I HILL) �,LNTURY FARM C4 Lu w Of E — — — — — — �— — NORTH SUB C4 8. CONTRACTOR TO PROTECT IN PLACE, DURING DEMOLITION AND CONSTRUCTION,ALL EXISTING IMPROVEMENTS THAT ARE TO REMAIN AS -i — — — - C ` NOTED ON THE PLAN. a i -- — — — GAS �n c —4— — — �— c — M P o C F6 �(i — GAS GAS C 9. ANY EXISTING STRUCTURE, IMPROVEMENT OR APPURTENANCE TO REMAIN THAT IS DAMAGED DURING DEMOLITION OR CONSTRUCTION o j F5 a? p_ SHALL BE IMMEDIATELY REPAIRED OR REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. (� w F6 0 c c c c6 — — c ° S3 — —c6 — — — — _ _ _I_ PROPERTY SUMMARY • �� Q • • • O x G x co x x x x x x x �x z x x—(�x xt�• • • • • • (p 4 N I I x�— F4z + —L — — — — - } — — — — — O s a /—GREEN 2X4 STUBS I __ R � I — — — �•-'� "' PROPOSED BUILDING AREA ± 11,300 SF �a o I i - R1 L J R1 R1 R1 R1 J 6 c1 O 9 0 C1 L—— — 1— — J NET PROPERTY AREA ±65,765 SF (1.51 AC) 2'$ F6(TYP) °' C1 ZONING SUMMARY EXC EXC EXISTING ZONING C-N �_-- F4= F2 FRONT R1 c BUILDING SETBACKS SIDE 0 0 1 30.0' t o \ PROPOSED BUILDING C1 P3(TYP) 3(TYP) (TYP)s4 REAR = 0' ± 11,300 SF ° S1 4 0 5 PARKING = 5' FFE: 2,688.40 P1 N I LANDSCAPE BUFFERS REAR = 20' 8 0' s2 C1 I PARKING E h»� I rn F3 F2 F1 C6 19.0' s 19.0' PROPOSED PARKING 35 SPACES w I P2 (TYP) 4 REQUIRED PARKING 23 SPACES 1 PER 500 SF o �I 1 39.6 11.5' P1 25.0 Tm�? f@BICYCLE PROPOSED PARKING 2 SPACES 64.3' i •�• • • R1 R1 r -1 11'4 5�I 5.0'1 BICYCLE REQUIRED PARKING 2 SPACES 1 PER 25 • i • • • i PARKING STALLS R1 R1 R1 L S1 ••i'•iioc�47.6'••�• � R1 R1 Cl 0 4 S s TYP 3 1 I I it i••i Ei.i.i i . i0...i. ;,�,•i'��©•,i+•'i ii••�li (i F2 w y w y w®y w w wy w y F6(TYP) F7 Cl KECURYNOTE LEGEND • • .i. . , s s ���� y y y w y w y y y y/y wyw F2 x 5 _0 I 1"{b ..i'iii . iii. ••.i`•. OB y y y w wwyywwyywwwyyw wyyw y • �� 1 ' i i . i • i i . w w y w y w y " " » y y w 3(TYP) C1 6 CONCRETE CURB & GUTTER (B612) - SEE DETAIL • © . i . O • y » w y w » (TYP)s4 1 C2 CONCRETE SIDEWALK-SEE DETAIL , �"� y M y y w y N y� y y M O O ° I I 1 . . .•i•.ii p � y F1 +i w M M M w y y w M w�* Q i . • • ./�i .i I /CO O —•a y .+� « yw«/M yww y wyw l w yF3 y (h ' , T t— •\i i•i i i i i.i.i'��j i i i. M M wd wwyyw yyywywy w ++�I w y w y w w w w N , - »/ "." w'+y++wwy wwy\w IwMyw y "y" y w 4 5 9 0 PROPOSED 5' PARKING 1 C4 MATCH EXISTING EDGE OF PAVEMENT/CURB & GUTTER •�t • i • + • i i +i Fs o LANDSCAPE BUFFER C5 COMMERCIAL DRIVEWAY APRON - SEE DETAIL I I •i . . . . • /. . i•./ M y +►y�(�w M y\'y w w w w/ w y 2 — L — i . i i i . y wd •wy • .• y * w w w y J/ w Cl 16.7 I �L./i . i F3 w w 'Pl".`"l9"0� °� y w y y w y Q EXC. 1 & � I ww+�w y ww °' y w w w y w y wwy y y y w C6 ACCESSIBLE CURB RAMP - SEE DETAIL Z - \ w w M M N y/N `p My /wwy wwy NyW EXC. 191"0 I \y w y y y y w y y 11 x �— —127.1' 61 5'— — — _ C7 INTEGRAL CONCRETE CURB/SIDEWALK- SEE DETAIL O I I � I 1 Y 2"� 2"0 L EXISTING 20' LANDSCAPE BUFFER '= _ — _ _ Am_ _ 2"0 � 3"¢ SITE FIXTURES04 cu � L x I 3 0 T 2„ _ _ — — — — — — N 1_ _ _ F1 4' BLACK VINYL COATED CHAIN-LINK FENCE - SEE DETAIL I I I 00 0 Lx —� � �- ICI F2 CHAIN-LINK FENCE SWING GATE - SEE DETAIL Z x x_ 3 3"0 2 0 I I �_- _x _ F3 6' BLACK VINYL COATED CHAIN-LINK FENCE - SEE DETAIL uj o I PLS 12459�� I BLUE PVC STUBS N I FOl1ND PLUG , . . . ILLEGIBLE . ` F4 SEMI-PRIVATE VINYL SCREENING FENCE - SEE DETAIL 12459 , I� �% `� `PLS 12459 BLUE PVC STUBS �PLS 12459 `� ��` 2 j o I BLUE PVC STUBS J HILLS CENTURY FARM `PLS 12459 `p F5 6' BLACK CRASH RATED ALUMINUM ORNAMENTAL FENCE - SEE DETAIL Q NO NORTH `PLS 12459 REBAR ENTRY EA 57018 NO CAP F6 McCUE BOLLARD - SEE DETAIL c I I 4zosoaszz•w F7 6" CONCRETE FILLED STEEL PIPE BOLLARD - SEE DETAILcu W Fs BICYCLE RACK � � I o I I J NO PAVEMENT MARKINGS w J Q ACCESSIBLE PARKING STRIPING AND SIGNAGE PER COM AND MUTCD O=z I Nz cn = O� J� O ILL. OP7 STANDAR DS AND SPECIFICATIONS. 2% MAX SLOPE I N ALL DIRECTIONS. - SEEQ o P 0- o d OL — � Q O 0 DETAIL0 N �o � Q �� OOO � Ot y O z m STRIPED YELLOW CROSS-HATCH AREA 4" SOLID LINES@45° 3' O.C. UJ O O Q m J m Q O J o LL_ O(n � m o � � z m o 4"WIDE WHITE PAINTED SOLID PARKING LOT LINE T � O � m O � 0 J 00 m m o = O y rqNw O O m mm CO z oo� O 4"WIDE YELLOW PAINTED SOLID PARKING LOT LINEW (n Q0 r- z � O > � N >_ S >_ z P N co O OJco� 0 — = m � m � Q mU m �coO � J OL � m coJTz JJ P PAINTED WHITE DIRECTIONAL ARROW- SEE DETAIL VW� O ~ O � O � co O OO � J � ( O _ O � Lj CD LL_ 119 _ 0 PAINTED WHITE CROSSWALK- SEE DETAILO = 0 ( r UJO J O ow� m m m 24"WIDE PAINTED WHITE STOP BAR- SEE DETAILO m mJ tY O m O Q J � w SIGNAGE m ON z J co O U NQ � z s1 ADA PARKING SIGN IN BOLLARD - SEE DETAIL Q r7 � = O = I m OJ u m S2 NO PARKING FIRE LANE SIGN - SEE DETAIL m STOP SIGN - R1-1 STOP SIGN PER MUTCD STANDARDS AND SPECIFICATIONS. In Z M I SEE DETAIL LL 0 Q 0 STAFF MEMBER ONLY PARKING NO � 2 I I / \ REFERENCE NOTES li Q a � I AT-GRADE BUILDING ENTRY& STRUCTURAL STOOP - REFER TO W E �' I I I R1 ARCHITECTURAL & STRUCTURAL PLANS a Q g — — — 1� — _ R2 MONUMENT SIGN - REFER TO ARCHITECTURAL PLANS ~ CC o `° R3 LIGHT POLE & BASE - REFER TO MEP PLANS L w�+ OL R4 TRANSFORMER/EQUIPMENT PAD - REFER TO MEP PLANS w W o° GRAPHIC SCALE IN FEET R5 TRASH ENCLOSURE - REFER TO ARCHITECTURAL PLANS z0 10 20 40 Q � R6 25' TALL FLAG POLE - REFER TO ARCHITECTURAL PLANS W 0 3 O 0- NORTH LL Q O m Caff811 CAUTION: NOTICE TO CONTRACTOR W o BDr9 reYou THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS 0 a v SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, W w UI U MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE o CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO '^ SHEET NUMBER REQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO �/, RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. C400 Y LE END m I — — PROPERTY LINE Anui .f SETBACK LINE Q I _ cl DRAINAGE AND UTILITY EASEMENT Ir x—x—x—x—x— PROPOSED FENCE - E AMITY ROAD PROPOSED CURB AND GUTTER, PER ISPWC SD-701 STANDARD DUTY ASPHALT PAYMENT i+ t SEE DETAILS FOR SECTION U) _ q PROJECT LOCATION r IV+ RIGHT OF WAY PAVEMENT F .-• I I F��.,__ _�., -_ 4, I I t- .? _ .> . �.. _ _ I I SEE DETAILS FOR SECTION � V _ w a° HEAVY DUTY CONCRETE PAVEMENT SEE DETAILS FOR SECTION w a:, CONCRETE SIDEWALK INSTALL PER ACHD SD-709,SEE DETAILS FOR SECTION = > I STORM WATER AREA k I EXC. 18 & r E I I I EXC. 19 SEE GRADING PLAN FOR DETAILS SITE PLAN NOTES z 1. REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF STOOPS,TRASH ENCLOSURES,&PRECISE BUILDING \\ I I I I I \\ a DIMENSIONS.REFER TO THE SITE ELECTRICAL PLAN FOR LOCATIONS OF PROPOSED LIGHT POLES,CONDUITS,AND ELECTRICAL EQUIPMENT. � \� I I I �� ,�I Lrai.:<+r.Ar�R>��,.r,e> I- -' I sro-7�L+r-Fs,-_.., •':MA?N'.e ap�,rE.rr I'q.'.:. .�, .,.a .r., 89.15.22"E 429.o9' l 2. REFER TO CERTIFIED SITE SURVEY OR PLAT FOR EXACT LOCATION OF EXISTING EASEMENTS,PROPERTY BOUNDARY DIMENSIONS,AND ----—SDCB (COVERED) — — — VICINITY MAP ADJACENT RIGHT-OF-WAY&PARCEL INFORMATION. _ _ I RIM=2684.49' 11 N.T.S. I 3. DIMENSIONS AND RADII ARE DRAWN TO THE FACE OF CURB, UNLESS OTHERWISE NOTED.DIMENSIONS ARE ROUNDED TO THE NEAREST L - - - - - - - - - - - - - - - - - - - - - - - - I I - - - - - SMH� TENTH FOOT,AND AREAS ARE ROUNDED TO THE NEAREST SQUARE FOOT. ell Ln I - -I- - - - - — INV. 8" PVC 4. UNLESS OTHERWISE NOTED,THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING EXISTING SITE IMPROVEMENTS THAT CONFLICT Uj W=2670.26' — — — — _ WITH THE PROPOSED WORK, INCLUDING BUT NOT LIMITED TO TRAFFIC SIGNS, LIGHT POLES,ABOVEGROUND UTILITIES, ETC. PERFOR Lu M - 1� - -I L — _---- - - - - - - - - - - - - - - - - - - - - - - — — — — — — — — — — — — — — — L — WORK IN ACCORDANCE WITH GOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS. COST SHALL BE Q Q j ILLEGIBLE — — — — — — ' ___— _ — — — — —E=2670�30' — — i — _ _ INCLUDED IN BASE BID. REBAR AND CAP \ o ° o POINT OF BEgNNI G 5. TYPICAL PARKING STALL DIMENSIONS SHALL BE 9.0 FEET IN WIDTH AND 19 FEET IN LENGTH UNLESS OTHERWISE INDICATED. co o v 0 PRIVATE DRIVE o a '�,, - I �I I I I I , - ui a I ILLEGIBLE I I� 1 I I I \ I 6. MONUMENT SIGN(S)ARE DETAILED ON THE ARCHITECTURAL PLANS AND ARE SHOWN FOR GRAPHICAL&INFORMATIONAL PURPOSES ONLY. Q � > is — — Q — — — — — _ _ PVC .� — CONTRACTOR TO VERIFY SIGN DIMENSIONS, LOCATION AND REQUIRED PERMITS WITH THE OWNER. Z j LU C — (n bi 2 7. CONTRACTOR TO VERIFY EXISTING IMPROVEMENTS SHOWN ON THE PLAN. 0 O Y I GRAY P C UBS C4 w = I ILLJ �ti�TURY FARM C4 w d � — — — — — — �— — NORTH SUB C4 8. CONTRACTOR TO PROTECT IN PLACE, DURING DEMOLITION AND CONSTRUCTION,ALL EXISTING IMPROVEMENTS THAT ARE TO REMAIN AS w O — — — - C %` NOTED ON THE PLAN. 2 U) a i - - - GAS n c  - - �- c - M o C F6 tj — GAS GAS C 9. ANY EXISTING STRUCTURE, IMPROVEMENT OR APPURTENANCE TO REMAIN THAT IS DAMAGED DURING DEMOLITION OR CONSTRUCTION o j F5 a? p_ SHALL BE IMMEDIATELY REPAIRED OR REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. c� w C F5 �— F6 0 co Q I • • • O x G x x x x x x -x - -x x z x x xt• • �•-'� c �p - - a - -c6 � c - - - - PROPERTY SUMMARY 0 z 2X4 STUBS R "' • �� PROPOSED BUILDING AREA ± 11,300 SF ca o I i - R1 L J R1 R1 R1 R1 J 6 c1 O 9 0 C1 L-- - I- - J NET PROPERTY AREA ±65,765 SF (1.51 AC) 2'$ @(TYP) °' Cl ZONING SUMMARY o I o I `EXC EXC EXISTING ZONING C-N L_-- F4= F2 R1 c BUILDING SETBACKS FRONT 00 o 30.0' t o \ PROPOSED BUILDING �scl 1 (TYP) 3(TYP)S. (TYP)s4 REAR = 0' ± 11,300 SF o 4 0 5 PARKING = 5' FFE: 2,688.40 P1 N I LANDSCAPE BUFFERS REAR = 20' h'o I 6 8 0� s S2 C1 I PARKING F3 F2 F1 C6 19.0' 19.0' PROPOSED PARKING 35 SPACES w I P2 (TYP) 4 REQUIRED PARKING 23 SPACES 1 PER 500 SF o "I I 39.6 11.5' P1 25.0 0 f� BICYCLE PROPOSED PARKING 2 SPACES °°' ' I 64.3' i •�• • • R1 R1 F_ -1 11'4 5 1 5.0'� BICYCLE REQUIRED PARKING 2 SPACES 1 PER 25 • > i > • i PARKING STALLS R1 R1 R1 L S1 ••i>••ioc�47.6'••�• � R1 R1 4 S s TYP 3 0 F3 >'.\•i�>i'.i>•'i•'.�ii>�ii'�i•©i'•>i,ii>'>>•''©i'>>�>>�i'i i>>'>`•/' ii aO O— (i,/� (i>/� 0 w>y�•»"wyy\»dy `"">l»w My»"w.M">w»y»»y N.M">®»wy y yy"/w»6 N*>"+1 N«y.wwy"5»Mwww»»w ywyy w» ww 1 _ _ CUR G Cl I KEYNOTE Cc41 LEGEN D F2 F7 5 1"b y " y w » w F6(TYP) PAVEMENT _0 F x� • 6� CONCR ETE CURB & GUTTER (B612) SEE DE TAIL3(TYP)18.0'—° i LID T (TYP)S4 CONCRETE SIDEWALK-SEE DETAIL>y> ' F N ,co L w . 3 y cy) 90 O i> I M MATCH EXISTING EDGE OF PAVEMENT/CURB & GUTT ER i 4 » » » » " &__ PROPOSED 5' PARKIN >> yww F8o i LANDSCAPE BUFFER 16.7 F3 C1 C COMMERCIAL DRIVEWAY APRON - SEE DETAIL QEXC. 18 & /w"y w"y --- EXC. 191"0 ACCESSIBLE CURB RAMP - SEE DETAIL 127.1'— - Z zA i - - _ C7 INTEGRAL CONCRETE CURB/SIDEWALK- SEE DETAIL O Q - - 1'"�i Y 0 - - �- - - _ _ - 2„� EXISTING 20 LANDSCAPE BUFFER 3"¢ SITE FIXTURES 7 —i � � - - - � — _ _ _ AL- N� x 3„� - = - - - -`- - - - - - - - - - - - - _ �! I_ _ _ F1 4' BLACK VINYL COATED CHAIN-LINK FENCE - SEE DETAIL (n M o x 3 0 2 F2 CHAIN-LINK FENCE SWING GATE - SEE DETAIL Z o a I I I x- - X_-- _x 3 _ F3 6' BLACK VINYL COATED CHAIN-LINK FENCE - SEE DETAIL W N I `�`FOWND PLUG PLS 12459�� ,' I; `� �`. �� �� �`. `� BLUE PVC STUBS F4 SEMI-PRIVATE VINYL SCREENING FENCE - SEE DETAIL LS I • ` . ILLEGIBLE . ` j 12459 ,' I� �% `� `PLS 12459 BLUE PVC STUBS �PLS 12459 `% ��` BLUE PVC STUBS J HILLS CENTURY FARM `PLS 12459 `p F5 6' BLACK CRASH RATED ALUMINUM ORNAMENTAL FENCE - SEE DETAIL a) 0 I NORTH SUB `PLS 12459 `�REBAR Q - 2- NO 1 EASEMENT NO CAP I I ENTRY N0. 57018 F6 McCUE BOLLARD - SEE DETAIL > U I F7 6" CONCRETE FILLED STEEL PIPE BOLLARD - SEE DETAIL W N 89°1Y22"W Q (� a29.o9' F8 BICYCLE RACK z I � � I o I I NO PAVEMENT MARKINGS w J Q ACCESSIBLE PARKING STRIPING AND SIGNAGE PER COM AND MUTCD J o I ~ Q O I z N C� N O J O L� P1 STANDARDS AND SPECIFICATIONS. 2% MAX SLOPE IN ALL DIRECTIONS. - SEE 0- 0 d OL� � I - � Qo Z � Q0 U m0 � N NC� � � Oz DETAIL Lu _0rr} y z I o O O O O O O N � � N J Q O z m P2 STRIPED YELLOW CROSS-HATCH AREA 4" SOLID LINES @ 45° 3' O.C. U J I r'� `� z � - N U O O O J o LL_ O m P3 4"WIDE WHITE PAINTED SOLID PARKING LOT LINE (n c Jm r� � y � Z J - Q O T � m oDJm O � Jm r� c� � � z OJoL- m0Q o � Joz � rq m � m r7 � m � OzJm O 0 00 z (/) I O � m � — m CO U O Z J — 0 = P4 4"WIDE YELLOW PAINTED SOLID PARKING LOT LINE z O � OL� NW CD r- z � O (n � � O > � m r� C� � � z 0 � N N � `S >_ z N5; mDm r� ONw co O z J m z m — m O coONO � N-) LIJ � � JNz rq — mom — QO O� Jm � OJT ~ m m � 0cr) — LijJ m P5 PAINTED WHITE DIRECTIONAL ARROW- SEE DETAIL _ W w zO _j ~ I � � � = coO � U = coo O O _j � ~ D 00 m co z J N ° J J m I m = 0 U) � H- 0 � � � _ N L j � � � � � CD Q N z U) D 0 u � Oz P6 PAINTED WHITE CROSSWALK- SEE DETAIL JO U J Jm m =0 CDJ Jm m 0 (n ~ O U O Jm r� NLi - U = = Q z I m = m O J J 0 0 0 o m m Q 0 m J m P7 24"WIDE PAINTED WHITE STOP BAR- SEE DETAIL V 0 � I m I m m = = z � J JO QzNwD Q: ! Jj � O SIGNAGE U I = z O I 0 = ::E zz = S1 ADA PARKING SIGN IN BOLLARD - SEE DETAIL Q m = O m S2 NO PARKING FIRE LANE SIGN - SEE DETAIL m STOP SIGN - R1-1 STOP SIGN PER MUTCD STANDARDS AND SPECIFICATIONS. O Q p Z M I SEE DETAIL LL 0 Q s4 STAFF MEMBER ONLY PARKING U O a � 2 I I / \ REFERENCE NOTES O li Q a c: I AT-GRADE BUILDING ENTRY& STRUCTURAL STOOP - REFER TO LLI E �' I I I R1 ARCHITECTURAL & STRUCTURAL PLANS LL >m a Q g - - - _ R2 MONUMENT SIGN - REFER TO ARCHITECTURAL PLANS CC o `° R3 LIGHT POLE & BASE - REFER TO MEP PLANS OL L Z a R4 TRANSFORMER/EQUIPMENT PAD - REFER TO MEP PLANS ° GRAPHIC SCALE IN FEET R5 TRASH ENCLOSURE - REFER TO ARCHITECTURAL PLANS z (/� w U °' 0 10 20 40 Q � R6 25' TALL FLAG POLE - REFER TO ARCHITECTURAL PLANS W NORTH z Q O Cai/811 CAUTION: NOTICE TO CONTRACTOR Lu o BDr9 reYou THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS m v SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, J I F- MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE j o CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO w SHEET NUMBER REQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. C400 Y L.L