HomeMy WebLinkAboutA-111 CODE FLOOR AND SITE PLANSUP.154 SFWOMAN'S RR.154 SFWOMAN'S RR111DN108 SFSTOR.108S-1128 SFSTOR.107S-136 SFIT106B154 SFPASS THRU114A-242 SFJANITOR/STORAGE109S-151 SFMEN110B50 SFWOMEN111B142 SFSTAFF113A-2268 SFOFFICE100B228 SFOFFICE101B125 SFHALL102B1287 SFSEATING &GAMES103A-299 Occ Max. per 903.2.1.2154 SFGAMES119A-2608 SFDRIVEWAY120NEW 6' WIDE 1hr DOUBLE DOOR AS SHOWN, VIF, UTILIZE MAGNETIC HOLD OPENS WITH AUTOMATIC CLOSERS, TRIGGERED TO RELEASE FOR 1hr PROTRECTION BY A FIRE/SMOKE ALARM IN BOTH ADJACENT BUILDINGSGAME AREA TO INCLUDE POOL TABLES, SHUFFLE BOARD, AND OTHER SIMILAR GAMES OF THIS TYPEEXISTING GLASS SECTIONAL DOORALL ITEMS SHOWN w/OUT NOTE ARE EXISTING AND ARE TO REM AIN AS IS -THIS IS A CHANGE OF USE APPLICATION TO CONVERT THE TYPE III-B CONSTRUCTION BUILDING FROM A "B OCCUPANCY" TO AN "S-2 OCCUPANCY", AND THE ONLY NEW SCOPE IS THE OPENING OF THE SHARED WALL OF THE ADJACENT COMMON OWNERSHIP PARCEL OF THE "127 SALOON" "127 SALOON" BAR / RESTAURANTE THIS SIDE OF WALL (SEE A-112 FOR OVERALL)ALLEY (ADJACENT PARCEL PROPERTY)EXIT #2EXIT #1EATD = 80'EATD = 74'EXISTING OPENING TO REMAIN AS ISSEE DETAIL ON A-211 FOR REINFORCEMENT OF NEW OPENING IN EXISTING CMU WALL2216' - 0"NE 2ND ST.ALLEYADJACENT BUILDINGADJACENT BUILDINGBARE GROUNDEXIST. AWNINGSEXISTING PARKINGEXISTING BUILDING EXTERIOR TO REMAIN AS ISREMOVE OLD BUILDING SIGNAGE, REPAIR WALLEXISTING TRASH SERVICE IN GARBAGE CANS ALONG ALLEY32' - 7"SPACE for (3) EXISTING PARKING STALLS (w/ GARAGE DOOR)18' - 0"19' - 4"9' - 0"9' - 0"9' - 0"EXISTING CURB CUT (AND EXTENDS ACROSS ALLEY)OPEN TO BELOWEXIT ACCESS TRAVEL DISTANCE = <60'LICENSEDARCHITECTAR 984486JAMES L. ESCOBARSTATE OF IDAHOCLIENT:DATEJOB NUMBERCONSULTANTPO Box 1277Eagle, ID 83616 208.546.2824PROFESSIONAL SEALTHIS DOCUMENT IS THE PROPERTY OF TRIAD DESIGN AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION.DRAWN BYTRIAD DESIGN01/17/2323-017for RYAN STEINBRONER725 NE. 2nd St Meridian ID, 83642, R5672000630, .08 Acres, Zoned O-TS 65 FT OF LOTS 11&12 BLK 4 MERIDIAN TOWNSITEA-11110/31/23127 SALOON EXTENSION INTO 725CODE,FLOOR ANDSITE PLANSJLE1/4" = 1'-0"1Floor Plan - With TI1" = 10'-0"2Site PlanNPROJECT LOCATIONEXISTING 127 SALOONPROJECT LOCATION2018 International Building Code2018 International Existing Building Code2018 International Mechanical Code2018 International Fuel Gas Code2018 Idaho State Plumbing Code2018 National Electrical Code2018 International Energy Code2009 ICC/ANSI /A117.1CODE SUMMARYCURRENT CODECONST. TYPETYPE III-B2018 IBC CHAPTER 3302.1OCCUPANCYCHAPTER 5504 & 506TYPE III-BALLOWABLE AREAGROUP A-2 9,500 S.F.ACTUAL AREA/FLRFIRST FLOOR3,013sfSECOND FLOOR465sfTOTAL sf3,475sf(Driveway: 612sf)TYPE III-BALLOWABLE STORIES/HT.2 STORIES/55' ABOVE GRADE PLANEACTUAL STORIES/HT.2 STORIES/ +-20'NEW OCCUPANCY TO BE GROUP A-2 and B (S-1 < 10%, ACCESSORY)FORMER OCCUPANCY WAS A B OCCUPANCYCHAPTER 6TABLE 601REQUIRED FIRE RESISTIVE RATINGSTABLE 602FIRE RESISTANCE RATING FOR EXTERIOR WALLSPRIMARY STRUCTURAL FRAMEEXTERIOR BEARING WALLSINTERIOR BEARING WALLSEXTERIOR NON-BEARING WALLSINTERIOR NON-BEARING WALLSFLOOR CONSTRUCTIONROOF CONSTRUCTIONTYPE III-B0 HR2 HR (NON-COMBUSTIBLE)0 HRSEE BELOW0 HR0 HR0 HRX < 5' =1 HR5' ≤X < 10'1 HR10' ≤X < 30'0 HRX ≥30'0 HRCHAPTER 9903.2.1.2 GROUP A-2BUILDING OCCUPANCY LIMITED TO 99 MAX, w/ NEW SMOKE/FIRE ALARM w/ INTERCONNECT TO MAGNETIC HOLD OPEN REQUIRED AT NEW 1hr FIRE DOOR LOCATIONCHAPTER 10TABLE 1006.3.EXITING & OCCUPANT LOAD99 OCCUPANTS, 2 EXITS REQUIRED2018 IEBC301.3.1PRESCRIPTIVE COMPLIANCECODE ANALYSISTHIS IS A CHANGE OF OCCUPANCY FROM A "PROFESSIONAL SERVICES" OFFICE BUILDING "B" TO A "TAVERNS/BARS" "A-2" ASSEMBLY GROUP w/ "B"OCCUPANCY"A-2" and "B" ("S-1" ACCESSORY) -PREVIOUS TENANT WAS "B"503.3ENGINEERING IS BEING PROVIDED FOR NEW 6' WIDE OPENING IN EXISTING MASONRY WALL506BUILDING WAS PREVIOUSLY PERMITED UNDER THE 2012 IBC, AND ALL EXISTING A-2/B OCCUPANCY ASSOCIATED REQUIREMENTS ARE BEING ADDRESSED FOR COMPLIANCE IN THIS NEW CODE ANALYSIS HEREINNOTE:EXISTING EXTERIOR WALLS ARE CMUWALL @ NEW OPENING EXISTS ON PROPERTY LINE = 1HR PROTECTION2018 IFC APPENDIX B: FIRE FLOW0-5,900sf1,500gpm1006.2.1 & 1017COMMON PATH OF EGRESS = 75'; EXIT ACCESS TRAVEL DISTANCE = 200'1/4" = 1'-0"3MezzanineTHIS IS AN EXPANSION OF THE EXISTING 4,616sf "127 SALOON" A-2 RESTAURANT INTO THE ADJACENT 3,475sf BUILDING (FORMERLY USED AS A B OCCUPANCY w/ PROFESSIONAL OFFICES). THE USE WILL BE THAT OF AN EXPANSION OF THE EXISTING RESTAURANT INTO THIS SPACE, WHICH WILL INCLUDE ADDITIONAL SEATING AND GAMING IN THIS PORTION OF THE FACILITY THUS REQUIRING A "CHANGE OF OCCUPANCY" FROM B TO A-2. AS WELL, THERE WILL BE STORAGE AND OFFICE FUNCTIONS HAPPENING WITHIN THIS BUILDING. THE MODIFICATION WILL BE THE ADDITION OF A FIRE RATED CONNECTION BETWEEN THE TWO BUILDINGS, ALLOWING FOR THE TWO SPACES TO BE CONNECTED AND OPERATE AS ONE. NO EXTERIOR MODIFICATIONS NOR INTERIOR IMPROVEMENTS ARE BEING ADDED OTHER THAN NOTED HEREIN AND INCLUDING THE MODIFICATION OF THE WALL OPENING w/ A NEW 1hr FIRE ALARM INTERLOCKED FIRE DOOR.NARRATIVEN725 E. 2nd St.FIRST FLOOR4,616sfSECOND FLOOR0 sfTOTAL sf4,616sf(Patio: 440sf)127 E. Idaho Ave.NO. DESCRIPTION DATEA Client Review 11/3/231 Plan ReviewResponses12/20/232 Removed Patio 01/17/2311222