Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
C5.6_Water Service
I III III I c„� o M E HOT BOX ENCLOSURE _ 9 ' s - -- - -- -- a - - - -L-- -- -�- -- -- ----- -L-- -- --�-- RPBPA SIZE TO MATCH Q METER SIZE �"� N • i I O I It \ I V w .M • :o I ` I NOTE 'y Z ~ i I c I I FINISHED RPBPA MUST BE APPROVED BY THE STATE OF IDAHO, DEPARTMENT OF Z ' " 1 GRADE ENVIRONMENTAL QUALITY AND MERIDIAN WATER DEPARTMENT. o I I I \� It " 1" DEVICE MUST HAVE 12" MIN CLEARANCE FROM FINISHED GRADE. WILKENS 975XL3 ' a II II.' II II II i , ;\•. A OTHER OTHERWISE APPROVED EQUIVALENT (MATCH METER SIZE) REDUCED N -- --------------- PRESSURE BACKFLOW PREVENTION ASSEMBLY). w Z L• .i II 2-1/2" . I ' - - 1 ° r l HEATED FLIP TOP FIBERGLASS HOT BOX MODEL HF013047028 OR OTHERWISE W w 2-1/2" : ' i : ' 2-1/2„ l f: I APPROVED EQUIVALENT. INSTALL ON 3'-1" x 6'-0" SLAB (USE MEANDERING Z ww �II II i I I N I I \ I �I A ■ � � SIDEWALK DETAIL FOR SLAB). 2" I WATER WATER W a 00 METER I IP p•-I I A II \r-r ®®® ;II \\ \ I I ,, '��III,,�fI II mI 7I--II---f-I----II-- mI a . 1I I-- a 'I ------I--III--TI m-I---1I --m-I---II " mI 1I mI 1" II mI-TI II-II-_---,__ a a \ ' 3 k -------I-----'i-,-'-l�- -I----I- I i I - --- ------ I I MAIN � cn o TUB, LLIJi --- METER 21/2„ 2 ' 2 2" 2-1/2 a •:s-::::: I L__ _ JI ✓ :�I METE R 1 IL- -- -- -- ------ -- -- -- -' I I ,, I ° I Q —F— METER NUMBER METER SIZE WATER METER LEGENDILAYOUT ONAL FNc I •—� °j I I ' / �_ �i v Ks ueLR—. PR la ° - • -'-- -- �- ° � t I I I I R #1 2� h s s » INSTALL FITTINGS PER LA LAYOUT. L METER 2 � N� 10-�y/1. 229 �6/2 02 3- FITTINGS TO BE BRASS OR COPPER W/ ---I -_I ___ r- - - - --- ----�- - - --- --- --- so el _ _ I I ' --- ----------- IRON THREADS PER ISPWC SECTION 82 < ° —1/ L-1/2" I I' I I II 2-1/2" METER # — / 404.2.4.E.1 I _______ ________ I " „ » o - -------- -------o-- ------ ------- - -------- ----------- - J ° SEE PLAN VIEW FOR SERVICE SIZING METER #4 1 1/2 of �� I• ._. I I 1 1 1 1' 1 >✓ " � �•— ���� /N CRP : . S I METER #5 2 I I I . , o o METER #6 1-1/2" BACKFLOW PREVENTION ASSEMBLY CHECKED BY: �• °'11 , %' I o o 2-1/2" '� I IN HOT BOX ENCLOSURE DAVID A. BAILEY P.E. I I .2-1/2" 0 1„ a 11 I .P a. all " 2„ I I METER #7 2» WATER METER SEE TABLE FOR SIZING DRAWN BY: 1" 1" ( ) JBD I o o o I ff r METER 8 2 VIEW I• I �1 SEE PLAN IE FOR LINE SIZING . . -------------- z <:A< I 2" IfI ! M2„E'E° R 4 ® —1 2" o I METER #9 2» — :WATER MAIN (SEE SHEETS 5.1-5.4 )L �_ _ CK\\\ METER 10* 2ff 2" 0 0 - EER 11 I METER #11* 2" > " �;'•: � 'I � :::.::.. ---r- " d� ' ,----- . I: a • .• .. • o •IIII I• 'I I ® \\\ iI • -_-_-_Tr' -- "- OR�- IIi=--_-_--_-_-III an-iI a i'° • ° ° • i'° • a --. .• i. / • "• 2-1/,Z» -- " . j---- - --------- 2"I.•" " C ] I-- P.° -- - " I — . 000 — - METERS SERVING SIX PLEXES SHALL HAVE RPBPA LOCATED IN FIRE RISER ROOM. 2" ------------- RATHER THAN IN ADJACENT O----- ------- Z ° a: ;/= --=-1.- --- SERVICE MST BE ROUTED TO RPBPA PRIOR 0 TO SPLITTING TO ADDITIONAL UNITS) n y - cL U NOTES o SERVICE LINE FROM STREET TO METER AND FROM METER TO STRUCTURES MAY NOT MATCH METER SIZE w a p pl $° 6 ��\ 1" SERVICES TO BE INSTALLED PER MERIDIAN W1 & W2 W o > � METER 5 a ----J r �_ 1„ I —1/2» 2-1/2» o d' Z \\\\\ 1-1/2"-2" SERVICES TO BE INSTALLED PER MERIDIAN W4 LLJ I q o 4 WATER SERVICES TO BE INSTALLED PER MERIDIAN W5 ---- ----------------------7 --- - --- 8 1 a i I II•' ---- ' LJ !! �� ' � '-----T ' ° ° _ • ,�' _ REFER TO MERIDIAN W6 FOR ELEVATION SET OF METER VAULT LIDS. MAY BE REQUIRED �IM I •• I �� � � ADD. BACKFLOW • -- A REFER TO MERIDIAN W9 FOR SERVICE HYDRANT PLACEMENT :::.�:. .• .. , -----r ; — /2" /I I II I I • o so ° ' • '— ! FROM BLDG TO 2 1 POOL. COORD. W/ 1" _.1" ; • ; ; � A SERVICE PIPING SHALL BE ANSI/AWWA C 901 POLYETHYLENE PER ISPWC SECTION 404.2.2.A. II I o o $• i I I MECH PLANS. ® • ' i -----L I ------ m °I : ---------- p -'-- -------------%'-'-T- - : ; •' " a A PROVIDE ADDITIONAL 4 (UNMETERED) FIRE SERVICES TO EACH SIX-PLEX. VERIFY SIZE W/ ARCHITECT PRIOR TO I-----I ------ Ll W I _ I - ORDERING MATERIALS. TI ----- m ,. I ----- ------ ° I{� I •m I • 2-1 2 0 0 0 ��� ' -----r I J " I _ / Ro, 1o, 10, 10, 10, 10 o I (' , ------ METER 9 :' . n ° , PROVIDE C-900 SLEEVES WHERE WATER SERVICES PASS THROUGH DRAINAGE SWALES CROSSING SWALES ARE III 14' I I I o I `a. . ° o ------ o °. 1 1" o a MAX 18 DEEP....SLEEVES AND CROSSINGS ARE BELOW DRAIN ROCK SWALES). II° � Q ---t- II •I o i i " 2-1/2" I 2-1/2" _ -- - THE CITY OF MERIDIAN REQUIRES THAT ALL WATER METERS AND WATERWORKS BRASS BE ANSI/NSF 61 { 2-1/2 2\1/2„ ----- O CERTIFIED. " v 2-1/2" � I J a I a a L I ll,a I as I • ___ I \< a • aa° "I / ,° 81e " I \\ III , rt_ ®®® ° I \ \ 8 -- ------ y ° I I . I \ \ )------- f I 2„ METER 10 to • I O I I I I I i - : •'...` 1" . � � 0 1„ 1„ III' °a .' •: : •..' a NOTES0 _____ I DEVELOPER IS AWARE THAT IF THE PROJECT IS SUBDIVIDED IN THE FUTURE, INDIVIDUAL WATER METERS AND R, . W a WATER/SEWER SERVICES WILL NEED TO BE INSTALLED TO EACH LOT AT THE DEVELOPER'S EXPENSE. I I I Jy I j 1" DEVELOPER TO PROVIDE ALL BUILDING ADDRESSES SERVED BY WATER METERS TO CITY OF MERIDIAN UTILITY II ilre .,I I o i I , " o ••• o '_" : o o. .. 1„ , ,- ,- • v a A� I BILLING (208) 888-4439 WHEN REQUESTING WATER METER. W — I ate\ �c�l�lc�l�c�lcClc� I © " N ' _' ' T I �� _ CITY OF MERIDIAN WATER QUALITY STAFF REQUIRED TO INSPECT BACKFLOW PREVENTION DEVICE PRIOR TO METER Q O n J - SET. \ Z w I N \I o I o o - I I p n ___--------_ ------------ I$ I I ' -11 < 0 0 0 w - e I I L--- _-14 W J I - I n \ • I d3 i , - -------- B --- ----r--------- - --- ------- --- ----r------ { o —1/2" 2-1/2 r- 2-1/2» 14 --- r 1 - 55 ------------ • w • I ®®® I �\JI�I II I \' - /5 °,------------ III .^ I L_r___r___r___r___r7__r___r___r___r__ __ ___r___r___r___r___r1 r__ \\\JI I I I I I I I I I I �•— • • - s� --I MEER 8 lli .• li :i I • �i ��• • • • • 2-1 2" �5 s 1-1/ - li i 11 — — — — — — — — — — — — — — — — — — — — — — — — I— — — — — — — — w • • • • • %' i• III I Ii s s s s s s sTs s s s �• R P UBL I SHRR �R. (PRl RA TR 2-1 2" W a I ®®® I -- --- ---------- ---------------- METER$ R s - o -- -- --- -- -- -- lr 2 s \ MEE ; L T--- - METER 7 - , r- ;'.":: I O I -- -- -- --- - -- -- -- --- -- -- - r - ---- 0 1-1/2" a 2 I a o a e . • I /z � I ° a . • e . a I --- __ _ ® ®' o i ® �/® ® 1» �----r--- o i I D i . o I \ ! 1 d I I I t I I I � \ m I\ I I I I 1 I \I \ I I I I I I I W I I I I < I - I u I I e m I I I I I � 1 1 2" m I � I � %o II o I II I I � 13 11 lid I 1 o I _ I I 2-1 2" L I 2-1 2" �^o �I , I - 1" - III m i III I I I I I S.1 I lla I I i I III DATE:m d I I I� 0 o I J III •� I 11 � °_; I I I � ®• 10-13-2023 I • ' PROJECT: III. I I L----------------- o m L I a C2021-027 III I I ___s___ __�___a _____ _ ��� ,�,�� ��� ` . a 0 0 �_____________ -- -� -- -- - -- SHEET III • I - -- -- - -- --—-- -- -- SC FEET III .I III 'I 1 =405o6 II•,..I _ ___ _ __