Loading...
HomeMy WebLinkAboutC8.1_Street Lighting Plan Q O E LEGEND = Ln ----------- SUBDIVISION BOUNDARY LINE N 5 T CENTERLINE __ C3 w co RIGHT-OF-WAY LINE Z LOT LINE Z PI CONST. PRESSURE IRRIGATION LINE a' o WITH IRRIGATION RISER = C3 N Z w ® GATE VALVE W/RISER W — = -,� r------------- ------ --------- ---- ------ ----------- ----------- ---------- ------ --------- ------ - -- -- ------ -------------- MAINLINE DRAIN �♦ W w r--------------------------------- ------------------------------ O W�- , r------------------------ ----------------------, --------- I r-----------------------� ;- �- -------------, -----------------------, ---------------------- r---------------------- O AIR RELEASE VALVE W --------------- I ; `, _/ ' ' ■� I I I BLOCK 5 ' I #77777C STREET LIGHT NUMBER `, BLOCK 1 I I I I I I I I U) <9 `I `I I I I I I ' I I W 1D ` I I I I I I ' ' I ' I `, , I I I I I I I I ; ; ' ' I I I O I ' I 1 ,. , < M , I I I I I I I I I I I I ' ' I I I I I I , I I I � W N , \ Q ~ C) O I I O I I t0 I I n , I ` I I W � � � I I I I I I I I (O W J I I I I I I , , I (� I , �I1 I I I I I I J I , \ ' ' I I I I ; ; ; ; O O O O O I V ` '1 ' I NOTE: V I I I I I I I I ' ' I I I I I I I ' n I I ^ I , \, I, I I I I I I I I ' ' ' ' I I I I I I I 7K O ' O I I O • Q "' "' 1 UNLESS OTHERWISE SPECIFIED STREET LIGHTS ARE TO BE W I I I I I I 2 I 1 TYPE 2 PER MERIDIAN STANDARD DRAWINGS T1 & T2. SEE 1 I` IN IN i 1 I I IN SHEET 6.3 FOR DETAILS AND SPECIFICATIONS I I I I I I , ; I I ! ! -- I I , , , , I I � I W `I` I` _______________J L________________________J L_______________________J L_______________________J L_______________________J L_______________________J L____ :'I, ��' `-----------------------J ---J -----------------------J `---------------------- i , ;% '% ; S\pN A L FNG I ' — — — — — - - // ``\\````�� 1I ---------------------- STREET ------------- I STREET LIGHTS ARE TO BE INSTALLED PER CURRENT CITY moo`` ���ENSFp Ilk,�� ----- S BLEACHF/ELD AVF - . OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS Q 10/23/2023 - --- ------------------------------ ---------------------5 BLEACHFIELD AVE. _�� -- 1 1 N20218 0 - -------- I , r------------------ r-------------------- - - I I ' (,-� ' i Of I I i i-------------------- , r----------------- I ' W ' L---------------------------J 1 r------------------ , r------------------ .y 1 I I 1 i__________________1 • ; ICI ; I I ; ; ; ; ' ' ; O ; / I �� B. D��� �- I • I I I ' I I I I I I , I --------------------- QI ! I STREET LIGHTING -------------------------- CHECKED BY: •7 I I '� I I ,.� t r� OL N I� I I I --_, DAVID A. BAILEY P.E. Q O O O 1 1. All street light construction shall be done in accordance with the N ' ' _ ' DRAWN BY: I I N I I N I I N , , � , I current version of the ISPWC the Meridian Supplemental Specifications I I I I I \ I I I I 1Electric • JBD to the ISPWC, and the National Electric Code. I , I , , I I I I I I ' ' , , / , , M I I I � I I I I I I I 2. A street lighting electrical permit shall be opened prior to starting ---------------------------� : I I ; : I i I I : I I � � Q I 9 9 P P P 9 10 ; O work. Use the online Citizen Portal at 3 -------------------- BLOCK 3 I I I I r O ! ! ! I :BLOCK 5 W .. r---------------------------- I L_________________J L____________________J L______—_ ____J L____________________J L_________________-, ' IdlanC y g ItlZen ACCBS t0 open O permit I ' I I I L____ I I , I / https://citizenportal.mer' it .or /C' ' s/ o e e ' -------------- __ ___ ____ I and request inspections. ---- , , r---____-, L _____ ________ _____ , --- - ; / ; i 3. Installation will require inspections for the concrete base reinforcing, O N j BLOCK 3 -- -----, -- ------ ; O ---- --- ----_ , bedding backfill and for the pole and associated wiring. I I I I I --ll I I � ' I r-------- r--------, r-------- I -----�-- __-----'� ' I � � W I O 1 BLOCK 5 I i -`" ' 4. Street light bases shall be located 10'min. from trees, 5'min. from fire N : _________� i L_________________________________J : 1 ---- ------- c0 r 00 O J I I I ' ' ' ' _ _ _ I I I I I I I I I I I I I I ' ' I ' I I � I � I I I I I I I r nts and 2'min from water meters � I I ________________________________ 1 5. Keep accurate notes of conduit unction box locations. Attach a IINIIINII II I II -- ' �------------------- r---- ----- _______, I redllned as built drawing of this plan sheet to the street lighting I -----___: I electrical permit or submit a hard copy to the Meridian Public Works � y y _______________________ ! �I Department prior to requesting final inspection. L j I Q ! 6. Contact the City Transportation and Utility Coordinator (208) 898 5500 0 • J L________J L________J L_ J locked t_ I ; I for questions regarding Utility Conflicts, or to accessmeter Nj ------ `----- -----J ------- ------- L_ ------------------------------ j : I pedestals. --------J --------J --------J - ------------------------------- 7.I I 1 All streetlight components shall be constructed within the � S. AMORITA AVE. -- - ---- - g t of w y II I o AMORITA —j — — — AMORITA — I ' - o I : I -----------------------------------, M O —___� ________i r-------- I _ _____ __ ___ ___ ___ ___ ___ ___ i_____- 1 1 I ___ I I ' 1 RIGHT-OF-WAY. WAY. . • } I j Ir— r_ —r r--_ __i j_ __j r— — J \ ' I �I I __ o I : I : Z I I LOCATED WITHIN RIGHT OF -- CONTRACTOR TO PROVIDE ' O -------------- V i AS-BUILT CONDUIT LOCATIONS TO DESIGN ENGINEER FOR ti ---------�I I — 1 INCLUSION IN RECORD DRAWINGS. DIGLINE PHONE # -800-342-1585 N�.I _ I I I I I I II I I - MERIDIAN CITY APPROVED STREET LIGHTING TABLE I -------------------------------� I L___ dd 0 ------i :. � � - --------,I i----------------------------- , i I o I 60 0 30 60 120 `------------- r------- MANUFACTURER MODEL LUMEN RANGE COLOR VOLTAGE NOMINAL HEIGHT MAST LENGH � � �'' � I I I m � I iiiiiiiiiiiiiiiiiii Z ---------- _ U SS L -J'�' : O I L-----------------------------------J SCALE IN FEET ---- ---------- `-------------- ; Iq COPPER/STREETWORKS CC -------------------------- I i ;-----------------------------------; 1 1"=6 0' LEOTEK AR13 4000-6000 BONZE 120-277V 25' OR 30' NA AT 25�' _ O ,mI _ _ ---8 9 AT 30 --------------- ----------- ----- -- : I - � I LU M EC TU LM ----------------- I I I 0 I I 1 rn I _ I ' O ' ----- ----------------------- , W `---------------------- -- 1 I : ___ NO. SIZE LIN.FT NO. SIZE LIN.FT L HOOPS RODS POLE TYPE X Y D E W m I O I �--------------------------- L � 11 GA.TAPERED STEEL TYPE 1-30' 24" 60" 10%z" 11" 11%z" 4 #4 21' 6 #4 36' O I � -------------------------JI WITH 3°RISE PROVIDE RAIN TYPE 1-35' 30" 84" 1OY2" 11" 1%,, 6 #4 41' 6 #6 39' - N I ; : TIGHT CAP- O r------------------------- MIN.O.D.AT TOP 4" TYPE 2 24" 60" 8" 9" 8" 4 #4 21' 6 #4 2T --------J R HISTORICAL 24" 60" 12" 13" N/A 4 #4 21' 6 #4 2T -------------- O 1 ; I r-----------------------------------I 1 1 ANCHOR BOLT SIZES AND LOCATION 1'�__-- PER MANUFACTURERS ON N — SEE ATTACHMENT 3/4"� SPECIFICATIONS ---------------' DETAILS GALv. .. •. _ _ _ - ' : CONDUIT LEVELING 51- HEIGHT 4" NUT I : W O.D.AT MAST 1„tiNO GAP, DO NOT GROUF - ARM BASE 1/2"THICK 6' �•"'�.:+ ;! ' _ : ' 3-11/16" GUSSETS �' '. .••..,\ � _"� ; \ I L______ J I 1/4" SEE SCHEDULE 18 J 111 FOR HOOPS AND TYPE 2AND HISTORICAL �- ----- - I , r-----------------------------------� LU PLASTIC' VERTICAL BARS POLE BASE DETAILLU = RI C'ONDUT Y ; --___—___ ________ _________ : 1 LU Q LONG HEX CAP w 2-1/2"WIRE ENTRY U' 4b'b" (CHASE EDGES) Y to Yz HANDHOLE REINFORCED WITH SCREWS TAP POLE PLATE 3"CLEARANCE m SQ. FOR 'a NO.3 GAUGE RING I I _..._.—... 1-1/2"WIDE WELD TO OUTSIDE I GROUND OF POLE COVER OF 11 GAUGE NEC APPROVED PLATE N GROUNDING GALV.HOLD DOWN II CONNECTOR NUT&WASHER 2 MIN.TO MAX. ' 'I I 4"X 6Y2" 3"CLEARANCE THREADS � 1" °� � `I B OCK 6 : - -------------------J REINFORCED r ____ �//� 2"MAX.GAP I I ____ ____ _ _ _______ . HAND HOLE �� BASE WIDTH"X' DO NOT GROUT 1 L _ o MIN.O.D.AT W BASE 8" ATTACHMENT DETAILS LEVEL NUT Y J AND WASHER TYPE 1 AND DAVIT POLE BASE DETAIL J : :T; SEE BASE DETAILS ;.�••;�..- � GENERAL NOTES: ri s- 1. CONCRETE FOR FOUNDATIONS SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE N GENERAL NOTES: STRENGTH OF 3,000 PSI. E 2. ALL REBAR REINFORCEMENT SHALL HAVE 3"CLEARANCE FROM OUTSIDE OF CONCRETE FOUNDATION. ppp 1. MATERIALS AND CONSTRUCTION 3. HOOP SHALL HAVE A 6"LAP LENGTH MINIMUM U SHALL CONFORM TO AASHTO •D• STANDARD SPECIFICATIONS FOR 4.BREAKAWAY BOLTS ARE REQUIRED WHEN ON STATE HIGHWAYS,SEE ITD STRUCTURAL SUPPORTS FOR STANDARD DRAWING 1-7-C. Nominal MH L R H Actual MH HIGHWAY SIGNS,LUMINAIRES,AND BOLT DIA.+/a' 5.TYPE I,TYPE 2 AND DAVIT POLE TO BE PROVIDED WITH METAL,2-PIECE BASE COVER TO MATCH POLE FINISH 30' 8' 2' 28.5' 30 TRAFFIC SIGNALS,5TH EDITION 6.ALL CONDUIT ELBOWS USED IN CONCRETE BASES SHALL BE RPC BASEPLATE AND BOLT DATE 35' 12' 2.5' 33 35 2. POLE SHAFT AND MAST ARM SHALL PATTERN DETAIL 7.STEEL CONDUIT SHALL BE USED TO EXTEND ELBOWS BEYOND FOUNDATION BE ROUND OR 12-SIDED STEEL 10-18-2023 35' 15' 3' 33' 35.5 8.SPARE STUBOUTS SHALL BE TERMINATED WITH A STEEL COUPLING AND PLASTIC 3. POLE SHAFT SHALL CONFORM TO PUSH PLUG AT BOTH ENDS PROJECT' ASTM A572 GRADE 50 C2023-002 REVISED JUN 2016 REVISED JUN 2016 SHEET CITY OF MERIDIAN STANDARD DRAWING NO. CITY OF MERIDIAN STANDARD DRAWING NO. SUPPLEMENTAL SUPPLEMENTAL DETAILS FOR SPECIFICATIONS TYPE 1 MAST ARM LUMINAIRE T SPECIFICATIONS STREET LIGHT BASE INSTALLATION T2 TO THE IDAHO STANDARDS FOR I TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION PUBLIC WORKS CONSTRUCTION