Loading...
HomeMy WebLinkAboutLandscape Plan GENERAL LANDSCAPE NOTES GENERAL IRRIGATION NOTES �••••••ZE0FI1) ••,,�� 1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS LANDSCAPE 1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN •`� 5� •�'�����'•• O �•� I I PLAN AND IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CORRECTLY. CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANY �`* •'�SSAYR !•� CONTRACTOR. IF QUANTITIES LISTED DO NOT CORRELATE WITH WHAT IS SHOWN ON THE DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE �'� 2: I I PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. THIS INCLUDES, BUT IS NOT CONTRACTOR'S RESPONSIBILITY. ' t LIMITED TO TREE, SHRUB, ROCK, TOPSOIL, MULCH, SEED OR SOD, EDGING, AND DRIP LINE UO QUANTITIES. 2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE IRRIGATION ' ` 0 W I I SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. J, L4,16E 77 o w Z 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF AVAILABLY THE WORK SHALL CONSIST OF PROVIDING AND INSTALLING ALL MATERIALS NECESSARY FOR A �•��'�`0•�I��/�� 4L��• � � o w o o OF w NOTSAVAIIFIED LABLEP THE MATERIAL FROM LANDSCAPE ARCHITECT WILL PROVIDEMMERCIAL RIES. IF A ALTERNA E PLANT SPECIFIED MATERIAL AUTOMATIC IS A�OMATIC CONTROLSMPLETE SYSTEM , ANDNALPOINT OF ASSOCIATED NLABOR.N, PIPE, VALVES, FITTINGS, HEADS, ��001,;D'Cym SELECTIONS. SUCH CHANGES SHALL NOT ALTER THE ORIGINAL BID PRICE UNLESS A CREDITst o o Z w o w w IS DUE TO THE OWNER. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK NZQU) 0-(n J w m Zo 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD UTILITIES 4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS. w a Q WITHIN CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG LINE, INC. - - - 1.800.342.1885. PROVIDE ADEQUATE MEANS OF PROTECTION OF UTILITIES AND SERVICES 5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES. DESIGNATED TO REMAIN. REPAIR UTILITIES DAMAGED DURING SITE WORK OPERATIONS AT 6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER FOR CONTRACTOR'S EXPENSE. PREVENTION OF BACKFLOW AND BACK-SIPHONAGE 4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF THE 7 I• - J i CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS THAT REQUIRE COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED PERCENT (100%) COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS W _ MITIGATION, NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE TO NOTIFY THE ui RESPONSIBLE PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING CONDITION. APPROPRIATE. o I 8. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION I I I 5 DELETERIOUS MATERIAL SUCH AS ROCK,RESPONSIBLE CONSTRUCTION I DEBRIS,PAGGREGATE EBASE ALL RATES WITHIN EACH CONTROL VALVE. Q I MATERIAL, ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL OPERATIONS. FINISH > I GRADES TO BE SMOOTH AND EVEN. GRADIENTS TO REMOVE LOW AND HIGH POINTS AND TO 9. IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER DEMAND F_ a BLOCK 1 I PROVIDE POSITIVE DRAINAGE. AREAS SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM THOSE -- - _ IRRIGATING TREES, SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS. z I 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL SHALL J I I I BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE INCH IN SIZE. 10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO I z _ _ J I REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE. IMPERVIOUS SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING AREAS. ~ w 10 I 11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO FURNISH AND z Q o O I 7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, I 2 0 NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN MATERIALS AND A PH INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO p z I F'z I w m w OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, ALL LAWN AND PLANTING AREAS. SHOULD THE PSI BE LESS THAN ADEQUATE, NOTIFY THE N I z o c>>w I O o D o Z ARCHITECT IMMEDIATELY. IN THE EVENT THAT THE ARCHITECT IS NOT NOTIFIED PRIOR TO THE W o I. CONTRACTORS ARE RESPONSIBLE TO EITHER: PROVIDE APPROVED IMPORTED TOPSOIL OR, 50.0' I o o Z� w AMEND THE ON-SITE TOPSOIL. START OF CONSTRUCTION, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY w INGRESS/EGRESS, I N N i= I o v=w o f w o w w Q NECESSARY REVISIONS. ANDPUBLIC UTILITIES, EMERGENCY I w I NLd o Q oN Z o Q `o w Q N 8 PLANTTOPSOEIR BEDS DEPTHS SHALL M NE; CURB ISLANDS AS FOLLOWS (WHERE APPLICABLE):MNALPLANT PLANTING BEDS WN SHALLBE 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND VAULTS ACCESS EASEMENT I o-w -w N WITH DURABLE TAGS CARRYING THE WARNING "DANGER-UNSAFE WATER OR NON-POTABLE wow X W w uj TREATED WITH APR,-EMERGENT HERBICIDE. WATER." w ui E=Q y 9. FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF AREAS SHALL NOT 13. INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE - EXCEED 3:1. ELECTRIC CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS, 6" TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF ACCESS. 10. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S RECOMMENDATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ _ _ _ o AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO INSTALLATION OF PLANT 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A SINGLE IV I PRIVATE DRIVE MATERIALS AND MULCH. ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND ACCESSORIES. - - - - -L _ _ � _ � � 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR 15. A MIN. OF 4" POP-UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO BE z- - - - - - - - - - - - - - - - _ TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING USED IN ALL PLANTER BEDS. . - �- - - - - - - - - - - - - - - - � - � - - - - - - - - CONDITION. - - - - - - - 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER VELOCITY IN L _ J I 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER PORTION ALL PIPES SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE SIZE TO BE 1". OF THE ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED BACK AND / TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON ALL TREES AND LARGE SHRUBS. 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY, PARKING, AND ALL SYNTHETIC BURLAP SHALL BE REMOVED FROM ROOT BALLS PRIOR TO BACKFILLING. WALKWAY SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE. IDENTIFY ENDPOINTS OF 13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT SLEEVING. THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR 18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A NOT IN HEALTHY CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND SPECIES AT NO COST VERTICAL CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD SURFACE. TO THE OWNER. 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND ALL 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER REQUIRED CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER. SIZE �9 BLOCK 1 �$ . . MANUFACTURER'S RECOMMENDATIONS. WIRE AND CONDUIT AS REQUIRED. 15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. REPAIR INCLUDES FqS C'qo O PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE BUT IS NOT LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS, CONTROL WIRES AND INSECTICIDES AND FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS AND EQUIPMENT, AND SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR SHALL ENSURE THAT THE DISEASE UNTIL FINAL ACCEPTANCE BY OWNER. EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING N QO,yFni �,� CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED �� RE-SET SETTLED PLANTS TO A PROPER GRADE AND POSITION. PRIOR TO THIS PROJECT. . 21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED O RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE DEAD MATERIAL. DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN z o OPERATION OF THE EXISTING SYSTEM DURING THE COARSE OF CONSTRUCTION. \ \ \ ov a / TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY NEEDED. 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN DRAWINGS z 0 W CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES APPARENT AND ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL INFORMATION 0 = > ro AND WEATHER AND SEASON PERMIT. PROVIDED ON DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND CONTACT THE Q E OWNER IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES OCCUR. \_ Q O 23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL PROVIDE A / � V NEAT AND LEGIBLE AS-CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND MAINTENANCE MANUAL, � W 4 / AND UP TO (8) HOURS OF ORIENTATION AND/OR TRAINING FOR THE OWNERS MAINTENANCE AND ��_ m roF TREE PROTECTION NOTES OPERATIONS STAFF. m z Q o Q o��� ,��� \�� �// 1. THE CONTRACTOR SHALL TAKE EXTREME CARE TO PROTECT THE CRITICAL ROOT ZONE OF 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF IT'S � U `v Q o___/ roF _ _ _ '� ALL TREES AT ALL TIMES THROUGHOUT PROJECT. ACCEPTANCE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR SHALL BE M J= S I/ - _ _ - - - - COMPLETED PROMPTLY BY THE IRRIGATION CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. - Q 2. PRIOR TO COMMENCING WORK, TEMPORARY FENCING SHALL BE INSTALLED IMMEDIATELY W Sty �;oQ C/gRO / AROUND EACH TREE IMPACTED BY DEMOLITION OR CONSTRUCTION. FENCING SHALL BE 25. yOy�NTERIZAT010NSDURINGR�HE GUARANTEE PERIODVIDE, AT NO L COST TO THE OWNER, SPRING START UP AND W z J wq y MAINTAINED THROUGHOUT THE COURSE OF THE ENTIRE DEMOLITION AND CONSTRUCTION G Q Q PROCESS. z G J W 3. BULK MATERIAL, EQUIPMENT, VEHICLES, AND CONSTRUCTION DEBRIS AND WASTE SHALL NOT U BE STOCKPILED WITHIN HE CRITICAL ROOT ZONE. 5 4. COMPACTION BY EQUIPMENT TRAFFIC IS PROHIBITED WITHIN THE CRITICAL ROOT ZONE. PLANT SCHEDULE 5. MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE. APPLY A MIN. 1.5" OF WATER OVER DECIDUOUS TREES CODE (STY BOTANICAL / COMMON NAME SIZE THE CRITICAL ROOT ZONE PER WEEK. THIS IS A MIN. RECOMMENDATION. CONTRACTOR IS RESPONSIBLE TO DETERMINE IF MORE WATER IS NECESSARY DURING CONSTRUCTION. 6. ANY DAMAGE TO EXISTING TREES DURING CONSTRUCTION SHALL BE THE CONTRACTORS GS 6 GLEDITSIA TRIACANTHOS 'SHADEMASTER' 2" CAL. B&B o RESPONSIBILITY. THE CONTRACTOR SHALL PERFORM REMEDIAL WORK TO DAMAGED TREES AT SHADEMASTER HONEYLOCUST THE CONTRACTOR'S EXPENSE. I EXISTING TREES CODE (STY BOTANICAL / COMMON NAME SIZE a I RM 1 EXISTING TREE TO BE RELOCATED EXISTING z ACHD LANDSCAPE NOTES SEE KEY NOTE 9 0 1. TREES SHALL NOT BE PLANTED WITHIN THE 10 CLEAR ZONE OF ALL ACHD STORM Z n I DRAIN PIPE, STRUCTURES, OR FACILITIES. 0 AND SP 14 EXISTING TREES TO REMAIN EXISTING V 2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE SEES TREE PROTECTONCNOTES AND KEY NOTES CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. LANDSCAPE COVER RM2 1 RELOCATED EXISTING TREE EXISTING 3. ALL TREES SHALL BE PLANTED A MINIMUM OF 5' FROM ALL ACHD CURBS AND/OR SEE KEY NOTE 10 � w ATTACHED SIDEWALK, UNLESS PLANTED WITHIN THE PARKSTRIP. ALL TREES PLANTED IN 0 50 100 150 PARKSTRIP SHALL BE CENTERED. z GROUND COVERS CODE QTY BOTANICAL / COMMON NAME CONT 0 3 Plan Scale: 1" = 50' U STREET TREE CALCULATIONS (1TREE/35 LF) w TR 3,432 SF TURF SOD RHIZOMATES SOD a w w RHIZOMATOUS TALL FESCUE CONTACT INFORMATION p BUFFER Q STREET NAME LF CALCULATIONS REQ PRVD L.L WIDTH ENGINEERING z OWNER LANDSCAPE CONSULTANT OTHER CODE QTY BOTANICAL / COMMON NAME CONT 5725 NORTH DISCOVERY WAY 3 BRIGHTON DEVELOPMENT INC. KM ENGINEERING, LLP S. WAYFINDER AVE. 20' 328 328 LF/ 35 9 9 BOISE,IDAHO 83713 0 2929 W. NAVIGATOR DR., STE. 400 5725 NORTH DISCOVERY WAY PHONE(208)639-6939 z MERIDIAN, IDAHO 83642 BOISE, IDAHO 83713 S. VANGUARD WAY 20' 427 427 LF / 35 12 12 EP2 37,831 EXISTING LANDSCAPE TO REMAIN NONE kmengllp.com a CONTACT: ZACH MEYERS PHONE: (208) 639-6939 PRESERVE AND PROTECT PHONE: (208) 378-4000 FAX: (208) 639-6930 21 21 SEE KEY NOTES DESIGN BY: WHB FAX: (208) 377-8962 CONTACT: ALYSSA YENSEN, PLA o TOTAL STREET TREES >_ G EMAIL: zme ers®bri htoncor com DRAWN BY: WHB Y 9 P EMAIL: ayensen®kmengllp.com MITIGATION REQUIREMENTS SHRUBS AND PERENNIALS Z SEE L2.0 FOR FULL PLANT SCHEDULE CHECKED BY: AY THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL ALL REQUIRED LANDSCAPE AREAS DATE: JULY 2023 z WITHL BE AT LEAST 70%VEGETATION AT MATURITY, WITH TOTAL TREES REQUIRED PROVIDED 21 21 MULCH USED UNDER AND AROUND RAGE PROJECT: 23084 Z / SHEET NO. a i THE PLANTS IN ACCORDANCE WITH J UDC 1 1-36-SN w L 1.0 o N 2 :� _ _ _ _ _ _ _ _ _ _ PLANT SCHEDULE ••••`�,ZEOFID '''•,, I \- DECIDUOUS TREES � BOTANICAL / COMMON NAME SIZE MATURE HXW CLASS OTHER � BOTANICAL / COMMON NAME CONT ,•�SSAYE�t;!•• 01 —� - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - � *�' :* ft 2 • . 1 I — 6 GLEDITSIA TRIACANTHOS 'SHADEMASTER' 2" CAL. B&B 40'X30` CLASS II 37,831 EXISTING LANDSCAPE TO REMAIN NONE r , a,✓%%S�_ I I I SHADEMASTER HONEYLOCUST PRESERVE AND PROTECT : : W '00OW I I SEE KEY NOTES .0 i L.4.46E 77 4 ti a I `••7/201 • (`��% AIRI "I J I EXISTING TREES G�TY BOTANICAL / COMMON NAME SIZE MATURE HXW CLASS 1,713 SF SHURBS, PERENNIALS, OR GRASSES — ,,,�'�L; D0000;SCNP4•.• I SHRUBS:3 ��������• I.° I 1 EXISTING TREE TO BE RELOCATED EXISTING VARIES CORNUS ALBA `IVORY HALO` TM SEE KEY NOTE 9 TATARIAN DOGWOOD PI—�P I PHYSOCARPUS WINE N ULIFOL US 'SUMMER WINE' Sn SUMMER I I 14 EXISTING TREES TO REMAIN EXISTING VARIES POTENTILLA FRUTICOSA `SUNSET` CO "sD I PRESERVE AND PROTECT SUNSET POTENTILLA I° ROSA X 'NOARE' SEE TREE PROTECTION NOTES AND KEY NOTES FLOWER CARPET RED GROUNDCOVER ROSE F I BLOCK 1 I 1 RELOCATED EXISTING TREE EXISTING VARIES SPIR EGIRL BETULIBIRCHFOLIA 'TOR I GOLD' O i — I SEE KEY NOTE 10 SPIRAEA NIPPONICA `SNOWMOUND` Lu — — — a 1 I SNOWMOUND SPIREA 8Is s s's I 8"s I I I GROUND COVERS � BOTANICAL / COMMON NAME CONT PERENNIALS: I I I I ECHINACEA PURPUREA L — _ PURPLE CONEFLOWER 3,432 SF TURF SOD RHIZOMATOUS SOD RUDBECKIA FULGIDA 'GOLDSTURM' 00 3 I w RHIZOMATOUS TALL FESCUE GOLDSTURM BLACK—EYED SUSAN 10 GAILLARDIA X GRANDIFLORA 'MESA BRIGHT BICOLOR' BLANKETFLOWER HEMEROCALLIS X 'STELLA DE ORO` STELLA DE ORO DAYLILY D4 l e I SALVIA X SYLVESTRIS 'MAY NIGHT' 3 I MAY NIGHT SAGE P �— <I GRASSES: z MISCANTHUS SINENSIS 'MORNING LIGHT' Q EULALIA GRASS _N 00 > I CALAMAGROSTIS X ACUTIFLORA 'KARL FOERSTER' > W a �Go FEATHER REED GRASS Lu ~ HEAVY METAL` BLUE SWITCH GRASS PANICUM VIRGATUM 'HEAVY METAL` N I z SD I BLUE SWITCH GRASS 0° O 3 s a °° L I___ KEY NOTES (TYPICAL) F 'o z 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL TREES WITHIN Z ° yj �so TURF AREAS. — �,— 2. VISION E E F CLEAR . THE —N MAXIMUM HEIGHT VEGETATIVE COVER AT WITHIN — TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE. wv TV —8-w 8 w 8 w 8 w 8 w a w 8 w a w 8 w 8 w s w 8 w s w 8 w 8 w 8 w 8 \ �° 3. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH 1" BLACK AND TAN ORGANIC PERMABARK (ROCK) 2 I — — — — — — — — — — — — — 8"w MULCH WITH PERMEABLE FABRIC WEED BARRIER. SUBMIT SAMPLE TO OWNER FOR APPROVAL PRIOR - - - - - - - - - - - - - - - 8�'s s i „ „ PRIVATE DRIVE — — — — — — s' TO ORDERING AND INSTALLING. THE USE OF MULCH OR ROCK AS THE ONLY GROUND COVER IN " \ 8-w / REQUIRED PLANTING ARES IS PROHIBITED. IMPERMEABLE PLASTIC WEED BARRIERS ARE PROHIBITED. "s—ems a �e=s _ \ I— — — — — — — — — — — — — — �s's \• / %� \ 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. I �8„� — - - - - - - - - - - - - - - - - - - -1 r-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 81'S \, L _ I 8 w -co — — — — _ • I\ 5. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES. 00 _00 I I — — — — — — — — — — — — — — — — — — — — 6. INSTALL FLAT—BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER BED. SEE L2.0-02. / o L - - J 7. EXISTING TREES TO REMAIN. PRESERVE AND PROTECT. SEE TREE PROTECTION NOTES AND PLANT SCHEDULE. / / a s� / \ 8= 8. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR ADJUST AS SHOWN. 61 os / x BOUND RY CONTRACTOR SHALL DISTURBANCE AS E NECESSARY. TRANSITION TWEENNE PATCH ALONG BACK PHASE W AND EXISTINGLANDSCAPESHALL E NON RECOGNIZABLE AND COHESIVE WHEN FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL / EXISTING LANDSCAPE PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS N OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION / /6�� f / SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR CIDs SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING O $ EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN z s OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION. $ �2 9. EXISTING TREE TO BE RELOCATED. SEE PLANT SCHEDULE, TREE PROTECTION NOTES, AND KEY NOTECID z O Z Q / o #10. O = Q Ip 8 10. RELOCATED EXISTING TREE. SEE PLANT SCHEDULE, TREE PROTECTION NOTES, AND KEY NOTE #9. — Q / / O BLOCK 1 — �, 1 / 5 co — W REMOVE DEAD/ DAMAGED 0 10 / BRANCHES AND PRUNE TO m Z INTERNATIONAL SOCIETY OF Q U ARBORICULTURE STANDARDS; Cb / � o / c' IMPROPERLY PRUNED TREES (/� Q V) / / O (AS DETERMINED BY THE — 0 9 Jam ` O O O SHALLCBEEREMOVEDCAND w W z a / W IP i `� / (2)—BVC WOOD TREE O O REPLACE. C Q STAKES(MIN. 6' HT) O G J TRUNK FLARE. LOCATE PRIOR z / / • �� CHAINLOCK 0000 O TO PLANTING. FLARE SHALL V--I 6 �P / / TREE TIES BE VISIBLE AFTER PLANTING. u MULCH PER PLAN KEEP S 1"-2" AWAY FROM TRUNK G ERR / 3 FLARE c0 / FINISH GRADE •� \ \ ��� / / CO / 3 ROOT— . o I= BERM WATERING BASING / BALL — o R R • \ 1 / 7 DEPTH _ = FERTILIZER TABLETS FOLD BACK BURLAP FROM N w Toe i I I I i I II i I I III TOP j OF ROOTBALL. m w� roe / _ REMOVE WIRE BASKET. �w / / NOTE: REMOVE TREATED ROOT— PACKFIBACKOFILL MIX GENTLY WATER 3 3 / W / �� BALL OR SYNTHETIC BURLAPz / 6 T • iW / / spy COMPLETELY. REMOVE WIDTH TO SETTLE SOIL AROUND O / ANY SOIL AND/OR ROOTBALL 7 �� L ��� MULCH AWAY FROM 8" MIN 8" MIN Z Q` s°i TREE CROWN AFTER PLANTING PIT ROOTBALL ON UNDISTURBED 5 T0F ® / 8'S INSTALLATION. PIT SHALL BE A MIN. 2 TIMES WIDER SOIL U m' 8 \ sh THAN ROOTBALL AT BASE AND A D TOF /15 3 pi a / MIN. 3 TIMES WIDER THAN ROOTBALL N IR \p/ ,yG\//J O 'Sci 8• '/ AT FINISH AS THE ROOTBALL.ALL BE 5 w S T0 e e� I •• s NOTES: �qNG 7 \\ \ ��—/ s 1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED z z UqR� STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL �/�/ 01 STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD. O 3 6 3 �� �p� — = _W — �� 8 I / DECIDUOUS TREE PLANTING AND STAKING DETAIL U co 7 / Z NTS O g ' � w I _ MULCH AT E N G I N E E R I N G LL PLANTER 5725 NORTH DISCOVERY WAY g \ 3 a �\ BEDS BOISE,IDAHO 83713 O TURF 8 PHONE(208)639-6939 kmengllp.com z z 2 _ _ _ DESIGN BY: WHB Z I Go to ��—III �I—I I I— = c` ^ DRAWN BY: WHB I III—I —III—, CHECKED BY: AY 111- DATE: J U LY 2023 z ,R I—III—III I I1=1I III =1I I- - —I I1-1I a m FINISH - PROJECT: 23 084 i — TOPSOILLANDSCAPE PLAN GRADE i. , I SHEET NO. _ a 0 30 60 90 CUT EDGE J Plan Scale: 1 = 30 SHOVEL CUT EDGE L2.0Lu a NTS