HomeMy WebLinkAbout2023-09-01 Public WorksWastewater
•
Distance to Sewer
Directly adjacent
Services
•
Sewer Shed
South McDermott
•
Estimated Project
See application
Sewer ERU's
•
WRRF Declining
PW Did not provide (check with Vicki Ly)
Balance
•
Project Consistent
Yes
with WW Master
Plan/Facility Plan
•
Impacts/concerns
• Flow is committed
• See Public Works Site Specific Conditions
Water
•
Distance to Water
Directly adjacent
Services
•
Pressure Zone
S
•
Estimated Project
See application
Water ERU's
•
Water Quality
None
•
Project Consistent
Yes
with Water Master
Plan
•
Impacts/Concerns
See Public Works Site Specific Conditions
PUBLIC WORKS DEPARTMENT
Site Specific Conditions of Approval
1. No permanent structures can be within 10' of the water main.
2. Water main along the common lot between Street J and Street M requires a 20' easement with the
water main centered in the easement.
3. Water mains crossing irrigation district infrastructure needs to be in a casing.
4. Water main from the Linder Rd Entrance to the Amity Rd Entrance through the site must be 12"
5. All permanent dead-end mains need to end in a fire hydrant.
6. All locations where there will be a temporary dead-end water main, where future development is
not part of this project, must have a 4" blow -off per Standard Drawing W 12.
7. Each phase of the development will need to be modeled to verify minimum fire flow pressure is
maintained
8. Sewer services cannot pass through infiltration trenches.
9. No permanent structures (trees, bushes, buildings, carports, trash receptacle walls, fences,
infiltration trenches, light poles, etc.) are to be built within the utility easement.
10. Sewer manholes are not to be within gutter/curb
General Conditions of Approval
1. Applicant shall coordinate water and sewer main size and routing with the Public Works
Department, and execute standard forms of easements for any mains that are required to provide
service outside of a public right-of-way. Minimum cover over sewer mains is three feet, if cover
from top of pipe to sub -grade is less than three feet than alternate materials shall be used in
conformance of City of Meridian Public Works Departments Standard Specifications.
2. Per Meridian City Code (MCC), the applicant shall be responsible to install sewer and water
mains to and through this development. Applicant may be eligible for a reimbursement
agreement for infrastructure enhancement per MCC 8-6-5.
3. The applicant shall provide easement(s) for all public water/sewer mains outside of public right of
way (include all water services and hydrants). The easement widths shall be 20-feet wide for a
single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat, but
rather dedicated outside the plat process using the City of Meridian's standard forms. The
easement shall be graphically depicted on the plat for reference purposes. Submit an executed
easement (on the form available from Public Works), a legal description prepared by an Idaho
Licensed Professional Land Surveyor, which must include the area of the easement (marked
EXHIBIT A) and an 81/2" x I I" map with bearings and distances (marked EXHIBIT B) for
review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO
NOT RECORD. Add a note to the plat referencing this document. All easements must be
submitted, reviewed, and approved prior to development plan approval.
4. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water (UDC 11-313-6). The applicant should be required to use any existing surface or
well water for the primary source. If a surface or well source is not available, a single -point
connection to the culinary water system shall be required. If a single -point connection is utilized,
the developer will be responsible for the payment of assessments for the common areas prior to
prior to receiving development plan approval.
5. All existing structures that are required to be removed shall be prior to signature on the final plat
by the City Engineer. Any structures that are allowed to remain shall be subject to evaluation and
possible reassignment of street addressing to be in compliance with MCC.
6. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be addressed per
UDC 11-3A-6. In performing such work, the applicant shall comply with Idaho Code 42-1207
and any other applicable law or regulation.
7. Any wells that will not continue to be used must be properly abandoned according to Idaho Well
Construction Standards Rules administered by the Idaho Department of Water Resources. The
Developer's Engineer shall provide a statement addressing whether there are any existing wells in
the development, and if so, how they will continue to be used, or provide record of their
abandonment.
8. Any existing septic systems within this project shall be removed from service per City Ordinance
Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and
inspections (208)375-5211.
9. Street signs are to be in place, sanitary sewer and water system shall be approved and activated,
road base approved by the Ada County Highway District and the Final Plat for this subdivision
shall be recorded, prior to applying for building permits.
10. A letter of credit or cash surety in the amount of 110% will be required for all uncompleted
fencing, landscaping, amenities, etc., prior to signature on the final plat.
11. All improvements related to public life, safety and health shall be completed prior to occupancy
of the structures. Where approved by the City Engineer, an owner may post a performance surety
for such improvements in order to obtain City Engineer signature on the final plat as set forth in
UDC 11-5C-3B.
12. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process, prior to the issuance of a plan
approval letter.
13. It shall be the responsibility of the applicant to ensure that all development features comply with
the Americans with Disabilities Act and the Fair Housing Act.
14. Applicant shall be responsible for application and compliance with any Section 404 Permitting
that may be required by the Army Corps of Engineers.
15. Developer shall coordinate mailbox locations with the Meridian Post Office.
16. Compaction test results shall be submitted to the Meridian Building Department for all building
pads receiving engineered backfill, where footing would sit atop fill material.
17. The design engineer shall be required to certify that the street centerline elevations are set a
minimum of 3-feet above the highest established peak groundwater elevation. This is to ensure
that the bottom elevation of the crawl spaces of homes is at least 1-foot above.
18. The applicants design engineer shall be responsible for inspection of all irrigation and/or
drainage facility within this project that do not fall under the jurisdiction of an irrigation district
or ACHD. The design engineer shall provide certification that the facilities have been installed in
accordance with the approved design plans. This certification will be required before a certificate
of occupancy is issued for any structures within the project.
19. At the completion of the project, the applicant shall be responsible to submit record drawings per
the City of Meridian AutoCAD standards. These record drawings must be received and approved
prior to the issuance of a certification of occupancy for any structures within the project.
20. A street light plan will need to be included in the civil construction plans. Street light plan
requirements are listed in section 6-5 of the Improvement Standards for Street Lighting. A copy
of the standards can be found at http://www.meridianciiy.orgzpublic works.aspx?id=272.
21. The City of Meridian requires that the owner post to the City a performance surety in the amount
of 125% of the total construction cost for all incomplete sewer, water and reuse infrastructure
prior to final plat signature. This surety will be verified by a line item cost estimate provided by
the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash
deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.
22. The City of Meridian requires that the owner post to the City a warranty surety in the amount of
20% of the total construction cost for all completed sewer, water and reuse infrastructure for
duration of two years. This surety will be verified by a line item cost estimate provided by the
owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash
deposit or bond. Applicant must file an application for surety, which can be found on the
Community Development Department website. Please contact Land Development Service for
more information at 887-2211.