HomeMy WebLinkAboutPZ - Staff Report
Page 1
HEARING
DATE:
September 7, 2023
TO: Planning & Zoning Commission
FROM: Sonya Allen, Associate Planner
208-884-5533
SUBJECT: Eagle Road Extended Stay Hotel – CUP
H-2023-0040
LOCATION: 2700 N. Eagle Rd., in the NW 1/4 of
Section 4, T.3N., R.1E. (Parcel
#S1104233650)
I. PROJECT DESCRIPTION
A Conditional Use Permit (CUP) is requested for a 4-story extended stay hotel with 124 rooms on 2.77-acres
of land in the C-G zoning district.
II. SUMMARY OF REPORT
A. Project Summary
STAFF REPORT
COMMUNITY DEVELOPMENT DEPARTMENT
Description Details
Acreage 2.77 acres
Future Land Use Designation Mixed Use – Regional (MU-R)
Existing Land Use Vacant/undeveloped land
Proposed Land Use(s) Hotel
Current Zoning C-G (General Retail & Service Commercial)
Proposed Zoning NA
Neighborhood meeting date 6/1/23
History (previous approvals) H-2022-0046 (PP, MDA Inst. #2023-033831); FP-2023-0002; H-2023-0030
(MDA)
Page 2
B. Project Maps
III. APPLICANT INFORMATION
A. Applicant:
Lacey Clark, KM Engineering – 5725 N. Discovery Way, Boise, ID 83713
B. Owner:
GFI – Meridian Investments, LLC – 74 East 500 South, Ste. 200, Bountiful, UT 84010-6251
Future Land Use Map
Aerial Map
Zoning Map
Planned Development Map
Page 3
C. Representative:
Same as Applicant
IV. NOTICING
Planning & Zoning
Posting Date
City Council
Posting Date
Newspaper notification
published in newspaper 8/16/2023
Radius notification mailed to
property owners within 300 feet 8/11/2023
Public hearing notice sign posted
on site 8/17/2023
Nextdoor posting 8/11/2023
V. COMPREHENSIVE PLAN ANALYSIS
FUTURE LAND USE: This property is designated Mixed Use – Regional (MU-R) on the Future Land Use
Map included in the Comprehensive Plan.
The purpose of the MU-R designation is to provide a mix of employment, retail, and residential dwellings
and public uses near major arterial intersections. The intent is to integrate a variety of uses together,
including residential, and to avoid predominantly single use developments such as a regional retail center
with only restaurants and other commercial uses. Developments should be anchored by uses that have a
regional draw with the appropriate supporting uses. For example, an employment center should have
supporting retail uses; a retail center should have supporting residential uses as well as supportive
neighborhood and community services. The standards for the MU-R designation provide an incentive for
larger public and quasi-public uses where they provide a meaningful and appropriate mix to the
development. The developments are encouraged to be designed consistent with the conceptual MU-R plan
depicted in Figure 3D in the Comprehensive Plan.
PROPOSED USE: This property is proposed to develop with a 124-room extended stay hotel.
TRANSPORTATION: The Master Street Map (MSM) does not depict any collector streets across this
property.
Goals, Objectives, & Action Items: Staff finds the following Comprehensive Plan policies to be applicable
to this application and apply to the proposed use of this property (staff analysis in italics):
• “Permit new development only where it can be adequately served by critical public facilities and
urban services at the time of final approval, and in accord with any adopted levels of service for
public facilities and services.” (3.03.03F)
City water and sewer service is available and can be extended by the developer with development in
accord with UDC 11-3A-21.
• “Require all new development to create a site design compatible with surrounding uses through
buffering, screening, transitional densities, and other best site design practices.” (3.07.01A)
A dense landscape buffer is required between the subject property and the abutting multi-family
development to the east.
Page 4
• “Encourage compatible uses and site design to minimize conflicts and maximize use of land.”
(3.07.00)
The proposed hotel use should be generally compatible with the future multi-family residential
apartments to the east, which should minimize conflicts between uses and maximize use of land.
• “Support infill development that does not negatively impact the abutting, existing development.
Infill projects in downtown should develop at higher densities, irrespective of existing
development.” (2.02.02C)
Development of the subject property with a hotel shouldn’t negatively impact the abutting future
multi-family development to the east or the existing commercial uses to the north and south or the
multi-family development to the south. (This development is not downtown.)
• “Provide pathways, crosswalks, traffic signals and other improvements that encourage safe, physical
activity for pedestrians and bicyclists.” (5.01.01B)
A pathway is required to be constructed along the west boundary of this site for pedestrian safety
through the commercial development.
• “Require urban infrastructure be provided for all new developments, including curb and gutter,
sidewalks, water and sewer utilities.” (3.03.03G)
Urban sewer and water infrastructure and curb, gutter and sidewalks are required to be provided
with development of this site.
• “Maximize public services by prioritizing infill development of vacant and underdeveloped parcels
within the City over parcels on the fringe.” (2.02.02)
Development of this infill site will contribute to maximizing public services.
VI. STAFF ANALYSIS
A Conditional Use Permit (CUP) is proposed for a 4-story extended stay hotel with 124 rooms on 2.77-acres
of land in the C-G zoning district as required by UDC Table 11-2B-2 and 11-4-3-23B because the hotel site
adjoins a residential district and existing residences (i.e. apartments) to the south. A multi-family
development is currently in the development process directly to the east as well in the C-G zoning district.
Future development of the subject property is governed by a development agreement (DA) #2023-033831),
which was recently amended but has not yet been recorded (H-2023-0030). The proposed development plan
for a hotel is generally consistent with the Option #2 conceptual plan in the DA. The DA allows one building
permit to be issued prior to subdivision of the property; subsequent building permit applications are not
allowed to be submitted until after the property is subdivided, although Certificate of Zoning Compliance
and Design Review applications may be submitted and approved prior to recordation of the plat.
This property was included in the final plat (FP-2023-0002) for Sessions Parkway Subdivision as Lots 3-5,
Block 1, which was recently approved by City Council but has not yet been recorded. The proposed site
plan depicts the hotel building spanning across property lines; therefore, if the hotel use goes forward,
a final plat modification application will be required prior to recordation of the plat to reduce and
reconfigure the lots; or, a property boundary adjustment application will be required to consolidate
Lots 3-5 if the plat is recorded before development of the hotel.
The property is required to be subdivided prior to issuance of Certificate of Occupancy; or the entire
frontage improvements along N. Eagle Rd./SH-55 will need to be constructed with development of this
site.
Page 5
The hotel shall operate in accord with the definition for such in UDC 11-1A-1, as defined by I.C. 67-
4711, which allows the sale/rent of a place to sleep to an individual for a period of less than 31
continuous days.
Dimensional Standards: Future development is required to comply with the dimensional standards of the
C-G zoning district listed in UDC Table 11-2B-3, except for the landscape buffer to residential uses, which
was reduced from 25- to a minimum of 5-feet by City Council with the recent development agreement
modification application (H-2023-0030).
Specific Use Standards: Per UDC Table 11-2B-2, hotels are required to comply with the specific use
standards listed in UDC 11-4-3-23. Per these standards, a CUP is required for any hotel that adjoins a
residential district or an existing residence. Accessory uses, including but not limited to, restaurants, retail,
drinking establishments and personal services may be allowed if such uses are completely within the hotel
structure; a drinking establishment, which is not proposed, requires separate approval.
Access: A curb cut exists at the northern boundary of the site for access via Eagle Rd./SH-55 through the
commercial property via an existing reciprocal vehicular & pedestrian ingress-egress easement (Inst. #2016-
003980). Access driveways for connectivity between uses and for access via N. Records Ave. are proposed
to the multi-family development to the east, currently in the development process. An access driveway to the
south is also planned for connectivity between uses. A right-in/right-out access driveway via N. Eagle
Rd./SH-55 was previously approved by City Council on the adjacent property to the south for access to this
development contingent upon approval from the Idaho Transportation Department (ITD). Reciprocal cross-
access easements are required to be granted to the properties to the south and east and recorded prior to City
Engineer signature on the final plat (FP-2023-0002).
Parking: Off-street parking is required to be provided in accord with the standards listed in UDC 11-3C-6B,
which require a minimum of one (1) space to be provided for every 500 square feet (s.f.) of gross floor area.
Based on 51,200 s.f.,a minimum of 102 vehicle parking spaces are required that comply with the
dimensional standards listed in UDC Table 11-3C-5. A total of 139 spaces are proposed, exceeding the
minimum standard by 37 spaces.
A minimum of one (1) bicycle parking space is required to be provided for every 25 proposed vehicle
parking spaces or portion thereof per UDC 11-3C-6G. Based on 139 proposed vehicle spaces, a bicycle
rack(s) capable of holding a minimum of five (5) bicycles is required to be provided that complies with the
design standards listed in UDC 11-3C-5C. Four (4) bicycle racks are depicted on the site plan, one at each
entrance to the building, which should accommodate the required spaces; calculations demonstrating
compliance with the minimum standards should be included on the site plan.
All off-street parking areas are required to be provided with a substantial wheel restraints to prevent
cars from overhanging beyond the designated parking stall dimensions as set forth in UDC 11-3C-
5B.3. When a bumper overhangs onto a sidewalk or landscape area, the parking stall dimensions may
be reduced 2-feet in length if 2-feet is added to the width of the sidewalk or landscaped area (to total a
minimum of 7-feet) planted in groundcover; the plans should be revised accordingly.
Walkways: A 4-foot wide pedestrian walkway is proposed within the perimeter buffer along the western
boundary of the site and crosswalks are distinguished from the vehicular driving surface through the use of
scored concrete as required. Two (2) additional crosswalks should be included across the east/west
driveway at the northern end of the site where walkways are proposed to stub from the hotel;
crosswalks should also be included across internal driveways to the south and west if pedestrian
facilities are planned on the opposite site of these driveways. The DA requires a decorative cross-walk
to be constructed across the drive aisle of the multi-family portion of the development (SWC of the
Village Apartments) to enhance pedestrian connectivity with development of this site.
Page 6
Landscaping: Parking lot landscaping is required to be provided on the site in accord with the standards
listed in UDC 11-3B-8C. The proposed landscaping within the parking lot appears to comply with these
standards.
The buffer to residential uses to the east is required to be comprised of, but not limited to, a mix of evergreen
and deciduous trees, shrubs, lawn or other vegetative groundcover that result in a barrier that allows trees to
touch within five (5) years of planting per UDC 11-3B-9C. There are existing trees in the eastern portion of
the buffer on the residential property to the east; evergreen trees should be included in the buffer on this
site in addition to the deciduous trees to achieve the mix of materials and barrier desired.
Design: Building elevations of the proposed structure are included in Section VIII.C below. Building materials
primarily consist of EIFS wall panels in two (2) different colors with a third accent color; architectural metal
siding in two (2) different colors as an accent material; and prefinished metal flashing/grilles/louvers. The
final design of the structure is required to comply with the design standards listed in the Architectural
Standards Manual and will be reviewed for compliance with these standards with the subsequent Design
Review application.
A Certificate of Zoning Compliance and Design Review application is required to be submitted for approval
of the proposed use, site design, landscaping and building design prior to submittal of a building permit
application to ensure compliance with UDC standards, previous conditions of approval, development
agreement provisions, and the conditions contained herein.
VII. DECISION
A. Staff:
Staff recommends approval of the proposed conditional use permit (CUP) with the condition listed in
Section IX in accord with the Findings in Section X.
Page 7
VIII. EXHIBITS
A. Site Plan (dated: 8/23/23)
Page 8
B. Landscape Plan (dated: 8/29/23)
Page 9
C. Building Elevations
Page 10
Page 11
IX. CITY/AGENCY COMMENTS & CONDITIONS
A. PLANNING DIVISION
1. Comply with the previous conditions of approval in effect for this site, as applicable [H-2022-0046
(PP, MDA Inst. #2023-033831); FP-2023-0002; and H-2023-0030 (MDA)].
2. A final plat modification application shall be submitted prior to recordation of the plat to reduce the
number and configuration of the building lots so that the hotel is on one lot intead of three lots and
doesn’t span across property lines; or, if the plat is recorded prior to development of the hotel, a
property boundary adjustment application shall be submitted to consolidate Lots 3-5, Block 1 of
Sessions Parkway Subdivision.
3. The property shall be subdivided prior to issuance of Certificate of Occupancy; or, the entire
frontage improvements along N. Eagle Rd./SH-55 shall be constructed with development of this site.
4. The site plan and/or landscape plan shall be revised as follows:
a. Include calculations for bicycle parking that demonstrate compliance with the minimum
standards listed in UDC 11-3C-6G and include a detail of the proposed bicycle racks that
demonstrate compliance with the design standards listed in UDC 11-3C-5C.
b. Either depict wheel restraints in parking spaces to prevent cars from overhanging beyond the
designated parking stall dimensions onto sidewalks or perimeter planter areas; or, add 2-feet to
the width of the sidewalk or landscaped area planted in groundcover to allow for vehicle
overhang – parking stall dimensions may be reduced 2-feet in length as set forth in UDC 11-3C-
5B.3
c. Depict two (2) additional scored concrete crosswalks across the east/west driveway at the
northern end of the site where walkways are proposed to stub from the hotel; and across internal
driveways to the south and west if pedestrian facilities are planned on the opposite side of these
driveways.
d. Depict a decorative cross-walk across the drive aisle of the multi-family portion of the
development (SWC of the Village Apartments) to the east to enhance pedestrian connectivity as
required by the development agreement.
e. Include the number of required vs. provided bicycle parking spaces in the Project Summary on
the site plan [a minimum of five (5) spaces are required based on 139 vehicle parking spaces].
Include a detail of the bicycle rack(s) that complies with the design standards listed in UDC 11-
3C-5C.
f. Include evergreen trees in the buffer to residential uses along the eastern boundary of the site to
achieve the mix of materials and barrier desired in UDC 11-3B-9C.
5. Future development is required to comply with the dimensional standards of the C -G zoning district
listed in UDC Table 11-2B-3, except for the landscape buffer to residential uses, which was reduced
from 25- to a minimum of 5-feet by City Council with the recent development agreement modification
application (H-2023-0030).
6. The hotel shall operate in accord with the definition for such in UDC 11-1A-1, as defined by I.C. 67-
4711, which allows the sale/rent of a place to sleep to an individual for a period of less than 31
continuous days.
7. The design of the structure shall comply with the design standards listed in the Architectural Standards
Manual.
5. A Certificate of Zoning Compliance and Design Review application is required to be submitted for
Page 12
approval of the proposed use, site design, landscaping and building design prior to submittal of a
building permit application to ensure compliance with UDC standards, design standards in the
Architectural Standards Manual, and the conditions contained herein.
6. The conditional use permit is valid for a maximum period of two (2) years unless otherwise approved
by the City. During this time, the Applicant shall commence the use as permitted in accord with the
conditions of approval, satisfy the requirements set forth in the conditions of approval, and acquire
building permits and commence construction of permanent footings or structures on or in the ground
as set forth in UDC 11-5B-6. A time extension may be requested as set forth in UDC 11-5B-6F.
B. PUBLIC WORKS
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=304023&dbid=0&repo=MeridianCity
C. ADA COUNTY HIGHWAY DISTRICT (ACHD)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=304026&dbid=0&repo=MeridianCity&cr
=1
D. DEPARTMENT OF ENVIRONMENTAL QUALITY (DEQ)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=304105&dbid=0&repo=MeridianCity
E. IDAHO TRANSPORTATION DEPARTMENT (ITD)
https://weblink.meridiancity.org/WebLink/DocView.aspx?id=304434&dbid=0&repo=MeridianCity
X. FINDINGS
A. Conditional Use Permit (UDC 11-5B-6E)
The Commission shall base its determination on the Conditional Use Permit requests upon the following:
1. That the site is large enough to accommodate the proposed use and meet all the dimensional and
development regulations in the district in which the use is located.
Staff finds that the subject property is large enough to accommodate the proposed use and
dimensional and development regulations of the C-G zoning district with the exception of the
reduced buffer to residential uses to the east approved by City Council with H-2023-0030.
2. That the proposed use will be harmonious with the Meridian Comprehensive Plan and in accord with
the requirements of this Title.
Staff finds that the proposed use will be harmonious with the Comprehensive Plan and is consistent
with the requirements on the UDC.
3. That the design, construction, operation and maintenance will be compatible with other uses in the
general neighborhood and with the existing or intended character of the general vicinity and that such
use will not adversely change the essential character of the same area.
Staff finds the design, construction, operation and maintenance of the proposed hotel use should be
compatible with other uses in the area and with the existing character of the general vicinity and
that such use should not adversely change the character of the area.
4. That the proposed use, if it complies with all conditions of the approval imposed, will not adversely
affect other property in the vicinity.
Staff finds the proposed use should not adversely affect other properties in the vicinity.
Page 13
5. That the proposed use will be served adequately by essential public facilities and services such as
highways, streets, schools, parks, police and fire protection, drainage structures, refuse disposal, water,
and sewer.
Staff finds that essential public services are currently serving this property except for water and sewer,
which will be extended with future development. Police and Fire currently provide services to this
property.
6. That the proposed use will not create excessive additional costs for public facilities and services and
will not be detrimental to the economic welfare of the community.
Staff finds the proposed use will not create excessive additional costs for public facilities and services
and will not be detrimental to the economic welfare of the community.
7. That the proposed use will not involve activities or processes, materials, equipment and conditions of
operation that will be detrimental to any persons, property or the general welfare by reason of
excessive production of traffic, noise, smoke, fumes, glare or odors.
Staff finds the proposed use will not involve activities or processes, materials, equipment and
conditions of operation that will be detrimental to any persons, property or the general welfare by the
reasons listed.
8. That the proposed use will not result in the destruction, loss or damage of a natural, scenic or historic
feature considered to be of major importance.
Staff finds the proposed use will not result in the destruction, loss or damage of a natural, scenic or
historic feature considered to be of major importance.
9. Additional findings for the alteration or extension of a nonconforming use:
a. That the proposed nonconforming use does not encourage or set a precedent for additional
nonconforming uses within the area; and
This findings is not applicable.
b. That the proposed nonconforming use is developed to a similar or greater level of conformity with
the development standards as set forth in this title as compared to the level of development of the
surrounding properties.
This findings is not applicable.