HomeMy WebLinkAboutL1.0_Landscape Cover 35' 25 GENERAL LANDSCAPE NOTES GENERAL IRRIGATION NOTES •.••'""""��•
LANDSCAPE BUFFER �
LANDSCAPE BUFFER BETWEEN C-G AND RESIDENTIAL 0FI'D %.,
MEASURED FROM BACK OF CURB BUFFER SHALL BE APPROVED AND INSTALLED 1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS LANDSCAPE PLAN AND 1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN CORRECTLY. �•` S .•••••••••• p '.�
3 WITH EACH INDIVIDUAL LOT DEVELOPMENT IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. IF CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANY DEMOLITION OR : •gSSAYE� '•
�I 4 PRIVATE DRIVE 1 4 11 3 QUANTITIES LISTED DO NOT CORRELATE WITH WHAT IS SHOWN ON THE PLAN, THE QUANTITIES SHOWN CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE CONTRACTOR'S RESPONSIBILITY. : *�` `; ;
II ON THE PLAN SHALL GOVERN. THIS INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, • r • : H
a"sD "SD 18"sD is"sD 18"SD 18"SD 18"sD 18"s TOPSOIL, MULCH, SEED OR SOD, EDGING, AND DRIP LINE QUANTITIES. 2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH =PROVIDES ADEQUATE ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. THE WORK SHALL CONSIST
W 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF AVAILABLY OF OF PROVIDING AND INSTALLING ALL MATERIALS NECESSARY FOR A COMPLETE SYSTEM INCLUDING POINT ' L 165
�F ° P o Fo F Fo F W ;WEo W = Foy �o w w W F Fo W W = = SPECIFIED PLANT MATERIAL FROM COMMERCIAL NURSERIES. IF A SPECIFIED PLANT IS NOT AVAILABLE, OF CONNECTION, PIPE, VALVES, FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL ASSOCIATED LABOR. ,��d••• 7-18-2 • �,`�`�:
- THE LANDSCAPE ARCHITECT WILL PROVIDE ALTERNATE PLANT MATERIAL SELECTIONS. SUCH CHANGES THE CONTRACTOR SHALL FURNISH THE ARCHITECT WITH A SHOP DRAWING SHOWING THE DESIGN ' '••••••Q' Q` `
'GI I id id id d id id id id d dp, +-id+ W i�r d id d W id i w� R SHALL NOT ALTER THE ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER. LAYOUT, PIPE SIZE AND TYPE, VALVE LOCATIONS AND TYPE, HEAD LOCATIONS AND TYPE, CONTROLLER 'i�� SCA •.
° - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - = - = - - - - - - - LOCATION AND TYPE, WIRE SIZING, ETC... FOR APPROVAL PRIOR TO CONSTRUCTION. ottesusis.•••
`I I W- W- W-W W-W W-W W-W W- W p 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD UTILITIES WITHIN
CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG LINE, INC. @ 1.800.342.1885. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK
° ° W �. 6 I M M M M M M M M M M M M PROVIDE ADEQUATE MEANS OF PROTECTION OF UTILITIES AND SERVICES DESIGNATED TO REMAIN.
I REPAIR UTILITIES DAMAGED DURING SITE WORK OPERATIONS AT CONTRACTOR'S EXPENSE. 4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS.
I
4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF THE 5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES.
W I I W IWI 5 3 I CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS THAT REQUIRE MITIGATION, 6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER FOR PREVENTION
NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE TO NOTIFY THE RESPONSIBLE PERSON
OF BACKFLOW AND BACK-SIPHONAGE
o � � / Z IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING CONDITION.
x °° I �� o z,� I I \ 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED AREAS. ALL 7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED PERCENT (100%) W M N
° IWI w w o Q Z L _j 9 DELETERIOUS MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, AGGREGATE BASE MATERIAL, COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPROPRIATE. Q m N
a o - I Fr z O 3� 10' ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL OPERATIONS. FINISH GRADES TO BE SMOOTH � L
W I 10' w w o'w wow PRESSURE IRRIGATION AND EVEN. GRADIENTS TO REMOVE LOW AND HIGH POINTS AND TO PROVIDE POSITIVE DRAINAGE. 8. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION RATES WITHIN
W W PRESSURE IRRIGATION w I w w Z Q EASEMENT \;� 0 3 EACH CONTROL VALVE.
x I EASEMENT V D'N w Q w
°< I � I a O 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL SHALL BE FREE
Ld cn w w? O i OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE INCH IN SIZE. REUSE EXISTING 9• IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER DEMAND AREAS
SURFACE TOPSOIL IF AVAILABLE. SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM THOSE IRRIGATING TREES,
a IW �1 I Cl- 7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS.
-W I 14' 30' WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN MATERIALS AND A PH OF 5.5 TO 7.0. IF
W CITY OF MERIDIAN I ON-SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO 10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS
CROSS ACCESSI . SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING AREAS.
W W SIDEWALK EASEMENT I AND , EITHER: PROVIDE APPROVED IMPORTED TOPSOIL OR, AMEND THE ON-SITE TOPSOIL. Ln
��W I BLOCK 1 CITY OF MERIDIAN 1 1. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO FURNISH AND INSTALL N w
W I 3-HL2 SEWER AND WATER 8. TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE APPLICABLE): LAWN AREAS-6" MIN.; PLANTER BEDS z
8 A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO ALL LAWN AND
1-- g
MAIN EASEMENT - 12" MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL BE TREATED WITH A Q
PLANTING AREAS. SHOULD THE PSI BE LESS THAN ADEQUATE, NOTIFY THE ARCHITECT IMMEDIATELY. IN
PRE-EMERGENT HERBICIDE. v
THE EVENT THAT THE ARCHITECT IS NOT NOTIFIED PRIOR TO THE START OF CONSTRUCTION, THE cn g �
CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS. > �
R2 9. FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE w � o g
W I DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF AREAS SHALL NOT EXCEED 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND VAULTS WITH o
7-BS O I 3.1. DURABLE TAGS CARRYING THE WARNING "DANGER-UNSAFE WATER OR NON-POTABLE WATER.' Z
W 10. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S RECOMMENDATIONS AND SHALL a
8-HS s i - - - OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO INSTALLATION OF PLANT MATERIALS AND MULCH. 13. INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE ELECTRIC v
I° 5-CK3
s � I 01 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS, 6" TO 12" AWAY FROM
- - - I ®� SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING CONDITION. EDGE OF PAVEMENT FOR EASE OF ACCESS.
�' II 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A SINGLE
G 2 i 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER PORTION OF THE ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND ACCESSORIES.
4. ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED BACK AND TUCKED UNDER THE
- 1 1-R3 EDGES OF THE SAUCER RINGS ON ALL TREES AND LARGE SHRUBS. ALL SYNTHETIC BURLAP SHALL
BE REMOVED FROM ROOT BALLS PRIOR TO BACKFILLING. 15. A MIN. OF 4" POP-UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO BE USED IN ALL
t 6-MM I PLANTER BEDS. o N
15' �; 13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE Z
POWER LINE I OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN HEALTHY 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER VELOCITY IN ALL PIPES
+ EASEMENT I CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND SPECIES AT NO COST TO THE OWNER.CLA SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE SIZE TO BE 1".
M W I PLANTED I TRUES N I 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY, PARKING, AND WALKWAY
'# TO PROXIMITY I MANUFACTURER'S RECOMMENDATIONS. SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE. IDENTIFY ENDPOINTS OF SLEEVING.
TO POWER LINE IIL
15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: 18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A VERTICAL
y N I PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE INSECTICIDES AND CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD SURFACE.
z w FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS AND DISEASE UNTIL FINAL
J 5-CK3 I ACCEPTANCE BY OWNER. 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND ALL REQUIRED
7-BS cc RE-SET SETTLED PLANTS TO A PROPER GRADE AND POSITION. CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER. SIZE WIRE AND CONDUIT AS
°I 1 8-HS - w
RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE DEAD MATERIAL. REQUIRED.
Q Ism TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY NEEDED.
I O 8 • CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES APPARENT AND 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS DAMAGED AS A
W I _ _ - J WEATHER AND SEASON PERMIT. RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. REPAIR INCLUDES BUT IS NOT
W 3-HL2 I LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS, CONTROL WIRES AND EQUIPMENT, AND
SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM
W S N °! TREE PROTECTION NOTES REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION
10 I I u SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT.
1. THE CONTRACTOR SHALL TAKE EXTREME CARE TO PROTECT THE CRITICAL ROOT ZONE OF ALL
TREES AT ALL TIMES THROUGHOUT PROJECT. 21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING
EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN OPERATION OF
THE EXISTING SYSTEM DURING THE COARSE OF CONSTRUCTION.
4 _ 2. PRIOR TO COMMENCING WORK, TEMPORARY FENCING SHALL BE INSTALLED IMMEDIATELY
_ _ I 1 AROUND EACH TREE IMPACTED BY DEMOLITION OR CONSTRUCTION. FENCING SHALL BE 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN DRAWINGS AND
F MAINTAINED THROUGHOUT THE COURSE OF THE ENTIRE DEMOLITION AND CONSTRUCTION ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL INFORMATION PROVIDED ON
PROCESS. DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND CONTACT THE OWNER IMMEDIATELY FOR
W I "' FURTHER DIRECTION IF DISCREPANCIES OCCUR.
y _ J 3. BULK MATERIAL, EQUIPMENT, VEHICLES, AND CONSTRUCTION DEBRIS AND WASTE SHALL NOT BE
W I L - - I STOCKPILED WITHIN HE CRITICAL ROOT ZONE. 23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL PROVIDE A NEAT AND z
WI I LEGIBLE AS-CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND MAINTENANCE MANUAL, AND UP TO (8) HOURS O
4. COMPACTION BY EQUIPMENT TRAFFIC IS PROHIBITED WITHIN THE CRITICAL ROOT ZONE. OF ORIENTATION AND/OR TRAINING FOR THE OWNERS MAINTENANCE AND OPERATIONS STAFF. -
I I 5 F 5. MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE. APPLY A MIN. 1.5" OF WATER OVER THE 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF IT'S
CRITICAL ROOT ZONE PER WEEK. THIS IS A MIN. RECOMMENDATION. CONTRACTOR IS ACCEPTANCE.
REPAIR
IIRRIR REP CONTRACTOR ANYNDEFECTS
O OCCURRING
TO THIN OWNER.
SHALL BE COMPLETED
RESPONSIBLE TO DETERMINE IF MORE WATER IS NECESSARY DURING CONSTRUCTION. Q
W 25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, SPRING START UP AND WINTERIZATION L u
� L - I I 6. ANY DAMAGE TO EXISTING TREES DURING CONSTRUCTION SHALL BE THE CONTRACTORS DURING THE GUARANTEE PERIOD. m >
W 0 N RESPONSIBILITY. THE CONTRACTOR SHALL PERFORM REMEDIAL WORK TO DAMAGED TREES AT Q
10 UZ O w�Z I M I - THE CONTRACTOR'S EXPENSE.
GRAVITY IRRIGATION o Q W 2 ���' N I O
W \ EASEMENT 'o�� o O �`0 I L - ACHD LANDSCAPE NOTES Z U
a ^���� I KEY NOTES (TYPICAL) ® uW
J.
a\ A, �� U �`tc, I s� I o 1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM DRAIN PIPE,
W 1 Q Lo
N I - 1. CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR STRUCTURES, OR FACILITIES.
\ \ I I - - VISION TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER Y Q
W \� \ �2� I - J 10' AT MATURITY WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE 2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION U
\ \ \ �' I I PRESSURE IRRIGATION ADJACENT STREET GRADE. AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. LJJ (�
` \ \\ \ __ ___ ---_- -� I N I EASEMENT o 2. ALL PLANTED BEDS TO RECEIVE A MIN. 3" DEPTH 1" MINI BLACK AND TAN Q 5 z
ORGANIC PERMABARK MULCH WITH PERMEABLE FABRIC BARRIER OR OWNER z
APPROVED EQUAL. THE USE OF MULCH OR ROCK AS THE ONLY GROUND PLANT SCHEDULE (/') Q
COVER IN REQUIRED PLANTING ARES IS PROHIBITED. IMPERMEABLE PLASTIC J
Pi WEED BARRIERS ARE PROHIBITED. z
pQ \� ��\ ` p� \ I n I Q� DECIDUOUS TREES CODE QTY BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS O
s �� W 2 8 3. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN AND PROTECT.
> ys P� \P/ co CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND PATCH BACK CC 5 CERCIS CANADENSIS 2"CAL.B&B 30'X25' CLASS I
7'� I W W,_ ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW AND
1 P ? 2 0 V 2 EASTERN REDBUD
Q \ I 2s ci \�� \ \ P \ \\�\ / Z W Q� EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN w
Lu
FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING
0 0) 9 LANDSCAPE PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A Ln
Oj z RESULT OF NEW CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE SP 7 EXISTING TREES TO REMAIN EXISTING VARIES EXISTING
EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND PRESERVE AND PROTECT
3 THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM SEE KEY NOTES AND TREE PROTECTION
/r ♦ c� � OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. NOTES
ot- s I �/ \ \ \ \ ��\\ ?S �,1 ` \ o �� CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, MS 4 MALUS"SPRING SNOW" 2"CAL.B&6 25 X20' CLASS
^�W PLANT MATERIALS DAMAGED DURING EXECUTION OF THIS PROJECT OR
vrI/�� c/\ _ 1'L, _ j Q DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN OPERATION OF 0
SPRING SNOW CRABAPPLE
� 1 ci \��� 12"s \� \\��\_ THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION.
12'S P1 _ `� PVC 2 PRUNUS VIRGINIANA'CANADA RED' 2"CAL.B&B 30'X20' CLASS I
a 4. EXISTING TREES TO REMAIN. PRESERVE AND PROTECT. SEE TREE PROTECTION
\'2"s �,_` L'(� NOTES. CANADA RED CHOKECHERRY
\ \ \ \ 5. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE
N LANDSCAPE PLAN \\ �I c\ \\`\ t2 S�t s\ \ P p, - - - - IN ALL TREES WITHIN TURF AREAS. SHRUBS,PERENNIALS,GRASSES CODE QTY BOTANICAL/COMMON NAME SIZE MATURE HXW
0 30 60 90 I o� ♦ \12"s � \ e PI3 - -
c _ w�\ _� 0 6. DEVELOPMENTS PRESSURIZED IRRIGATION POINT OF CONNECTION. THIS SHALL 0 BS 14 BUXUS SEMPERVIRENS'SUFFRUTICOSA' 2 GAL. 1'X2'
Plan Scale: 1" - 30' �I 12"s \ \ BE THE PRIMARY SOURCE OF WATER FOR THE COMMON AREA STREET TRUE DWARF BOXWOOD
7 BUFFER IRRIGATION. NOTE: THE PI SYSTEM IS PUMP STATION AND POTABLE
s �� �� BACKUP WERE DESIGNED AND INSTALLED AS A PART OF VILLAGE APARTMENTS
o \ \G \�\ PHASE I. ° CK3 10 CALAMAGROSTIS X ACUTIFLORA 1 GAL. 4'X2'
'KARL FOERSTER'
�, O REMOVE DEAD/ DAMAGED I ci \\`\��� , 7. EXISTING PUMP SYSTEM AND ASSOCIATED POTABLE BACKUP DESIGNED AND FEATHER REED GRASS
N BRANCHES AND PRUNE TO ISA \\ \ �s ��� INSTALLED AS A PART OF VILLAGE APARTMENTS PHASE 1.
(2)-BVC WOOD TREE o oo STANDARDS;IMPROPERLY PRUNED \ �� + HS 16 HEMEROCALLIS X'STELLA DE ORO' 1 GAL. VX2'
STAKES (MIN. 6' HT) o 0 o TREES (AS DETERMINED BY THE ` ci �� 8. C-G TO RESIDENTIAL BUFFER. BUFFER SHALL BE APPROVED AND INSTALLED STELLA DE ORO DAYLILY
LANDSCAPE ARCHITECT) \ci �� ' 's I AS PART OF EACH INDIVIDUAL LOT DEVELOPMENT.
CHAINLOCK �O�O O SHALL BE REMOVED AND REPLACE. _
w TREE TIES p �� - \ci �� _ I 9. EXISTING FENCE TO REMAIN. PRESERVE AND PROTECT. AaN HL2 6 HYDRANGEA PANICULATA'LITTLE LIME' 2 GAL. 4'X4'
z 6>, TRUNK FLARE. LOCATE PRIOR TO �c� ��N 2, LITTLE LIME HYDRANGEA
PLANTING. FLARE SHALL BE s
3„ MIN VISIBLE AFTER PLANTING. o \ 10. INSTALL FLAT-BLADE SHOVEL EDGING AT INTERFACE OF SOD AND PLANTER
BED. SEE L1.0-2.
3" HT. WATERING BASING BERM ci I MM 6 MISCANTHUS SINENSIS'MORNING LIGHT' 1 GAL. 5'X4'
NOTES: 11. REMOVE EXISTING LAWN AND INSTALL ALL NEW LAWN AND IRRIGATION IN THIS EULALIA GRASS
1. REMOVE TREATED OR 3' FINISH GRADE AREA. KEY NOTE #4. AREA SHALL BE IRRIGATED VIA THE COMMON AREA
a SYNTHETIC BURLAP ROOT- - MULCH PER PLAN KEEP 1"-2" sA STREET BUFFER IRRIGATION SYSTEM.
o COMPLETELY. ALL ° AWAY FROM TRUNK FLARE MULCH AT R3 11 ROSA SP. 2 GAL. 2'X3'
Z 2. REMOVE ANY SOIL DEPTHT I = PLANTER �i OSO EASY PAPRIKA ROSE N G I N E E R I N G
AND/OR MULCH AWAY -I I =I I I ... FERTILIZER TABLETS GRADE TURF BEDS 5725 NORTH DISCOVERY WAY
N FROM TREE CROWN _ BOISE,IDAHO 83713
AFTER INSTALLATION. I III III- I FOLD BACK BURLAP FROM TOP OTHER CODE QTY BOTANICAL/COMMON NAME CONT PHONE(208)639 6939
Z 3. THE CONTRACTOR IS ' ' " ' ' BASKOF ET. LANDSCAPE
REMOVE WIRE _ _ _ _ _ _ LANDSCAPE BUFFER CALCULATIONS (1 TREE/35 LF, 1 SHRUB/7 LF) CONTACT INFORMATION - kmengllp.`°m
ROOT-
g RESPONSIBLE TO INSURE BALL BACKFILL SOIL MIX GENTLY PACK IIIIIII-III -III h I TBD 11,816 SF RESIDENTIAL BUFFER LANDSCAPING VARIES
_ _ DESIGN BY: WHB
Z THAT ALL TREES ARE ^ TREES TREES
o PLANTED STRAIGHT WIDTH BACKFILL USING WATER TO SETTLE I I =III-I I-, I I-- -� BUFFER LOCATION WIDTH LF LANDSCAPE CONSULTANT TO BE APPROVED AND INSTALLED
SOIL AROUND ROOTBALL I - - DRAWN BY: WHB
AND THAT THEY REMAIN I I III-III- `A 1-III III- REQUIRED PROVIDED REQUIRED PROVIDED KM ENGINEERING, LLP WITH INDIVIDUAL LOT DEVELOPMENT
STRAIGHT FOR ROOTBALL ON UNDISTURBED I- �. CHECKED BY: AY
Z 8" MIN 8" MIN III-III-�I I-I III -� �_ -III-I I N. EAGLE RD. 35.0' 392 11.00 11.00 11.00 11.00 5725 NORTH DISCOVERY WAY
o MINIMUM OF 1 YEAR. PLANTING PIT SOIL _
w ALL STAKING SHALL BE PIT SHALL BE A MIN. 2 TIMES WIDER THAN I I i III-III-III-. I- -III I=I BOISE, IDAHO 83713 DATE: MARCH,2023
REMOVED AT THE END ROOTBALL AT BASE AND A MIN. 3 TIMES I I. ,III-III=III-- I =I I- TOPSOIL MITIGATION REQUIREMENTS PHONE: (208) 639-6939 SOD/SEED CODE QTY BOTANICAL/COMMON NAME CONT
Z OF THE ONE YEAR WIDER THAN ROOTBALL AT FINISH GRADE. I -III=i CUT EDGE ( ) 639-6930 PROJECT: 23-021
FAX: 208
g WARRANTY PERIOD. DEPTH SHALL BE SAME AS THE ROOTBALL. THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL CONTACT: ALYSSA YENSEN, PLA TR 13,191SF TURF SOD RHIZOMATOUS SOD SHEET NO.
SHOVEL CUT EDGE Q EMAIL: °yensen®kmengllp.com RH IZOMATOUS TALL FESCUE
N DECIDUOUS TREE PLANTING AND STAKING DETAIL TURF CALCULATION (65/o EXCLUDING PARKWAY) ALLOWED PROVIDED L1.0
a
NTS NTS 2639 SF 2350 SF