HomeMy WebLinkAboutPZ - Geotechnical Investigation ENGINEERING •GEOTECHNICAL •ENVIRONMENTAL (ESA I & II) • MATERIALS TESTING •SPECIAL INSPECTIONS • ORGANIC CHEMISTRY • PAVEMENT DESIGN •GEOLOGY
PRELIMINARY GEOTECHNICAL
ENGINEERING STUDY
Maslonka Property
NE Corner of Linder Road and Amity Road
Boise, Idaho
CMT PROJECT NO. 13175
FOR:
DevCo, LLC
Laren M. Bailey, MCRP, PMP
September 12, 2019
ENGINEERING • GEOTECHNICAL • ENVIRONMENTAL (ESA I & II) • MATERIALS TESTING • SPECIAL INSPECTIONS
ORGANIC CHEMISTRY • PAVEMENT DESIGN • GEOLOGY
www.cmtlaboratories.com
September 12, 2019
DevCo LLC
Attn: Laren Bailey
Subject: Preliminary Geotechnical Engineering Study
Maslonka Property
NE Corner of Linder and Amity
Boise, Idaho
CMT Project No. 13175
Mr. Bailey:
Submitted herewith is our preliminary geotechnical engineering study for the subject site. This report contains the
results of our findings with respect to the available project characteristics.
On August 23, 2019, a CMT Engineering Laboratories (CMT) engineer was on-site and supervised the excavation of 4 test
pits extending to a depth of about 10 feet below the existing ground surface. Soil samples were obtained during the
field operations and subsequently transported to our laboratory for further testing and observation.
We appreciate the opportunity to work with you at this stage of the project. CMT offers a full range of Geotechnical
Engineering, Geological, Material Testing, Special Inspection services, and Phase I and II Environmental Site Assessments.
With 9 offices throughout Utah, Idaho and Arizona, our staff is capable of efficiently serving your project needs. If we
can be of further assistance or if you have any questions regarding this project, please do not hesitate to contact us at
(208) 912-1868.
Sincerely,
CMT Engineering Laboratories Reviewed by:
Phillip Pack, P.E. Greg Mugavero
Senior Geotechnical Engineer Regional Manager
TABLE OF CONTENTS
1.0 INTRODUCTION ............................................................................................................................................................3
1.1 General ...................................................................................................................................................................................3
1.2 Objectives, Scope and Authorization ......................................................................................................................................4
2.0 FIELD EXPLORATION .....................................................................................................................................................4
2.1 General ...................................................................................................................................................................................4
3.0 LABORATORY TESTING .................................................................................................................................................5
4.0 SITE CONDITIONS .........................................................................................................................................................5
4.1 Surface Conditions ..................................................................................................................................................................5
4.2 Subsurface Soils ......................................................................................................................................................................5
4.3 Groundwater ..........................................................................................................................................................................6
4.4 Site Subsurface Variations ......................................................................................................................................................6
5.0 LIMITATIONS ...............................................................................................................................................................6
APPENDIX
Figure 1: Site Plan
Figures 2 -5: Test Pit Logs
Figure 6: Key to Symbols
Preliminary Geotechnical Engineering Study Page 3
Maslonka Property – Boise, Idaho
CMT Project No. 13175
1.0 INTRODUCTION
1.1 General
CMT Engineering Laboratories (CMT) was retained to conduct a preliminary geotechnical subsurface study for
the proposed development of a residential subdivision. The parcel is situated on the NE corner of Amity Road
and Linder Road in Boise, Idaho, as shown in the Vicinity Map below.
SITE
VICINITY MAP
Preliminary Geotechnical Engineering Study Page 4
Maslonka Property – Boise, Idaho
CMT Project No. 13175
1.2 Objectives, Scope and Authorization
The objectives and scope of our study were planned in discussions between Mr. Laren Bailey of DevCo LLC and
Phillip Pack of CMT Engineering Laboratories (CMT). In general, the objectives of this study were to define and
evaluate the subsurface soil and groundwater conditions at the site.
In accomplishing these objectives, our scope of work has included performing field exploration, which
consisted of the excavating/logging/sampling of 4 test pits, and performing laboratory testing on
representative samples. This scope of work was authorized by returning a signed copy of our proposal dated
August 8, 2019.
2.0 FIELD EXPLORATION
2.1 General
In order to define and evaluate the subsurface soil and groundwater conditions at the site, 4 test pits were
excavated with a backhoe at the site to a depth of approximately 10 feet below the existing ground surface.
Locations of the test pits are shown on Figure 1, Site Plan, included in the Appendix. The field exploration was
performed under the supervision of an experienced member of our geotechnical staff.
Representative soil samples were collected by obtaining disturbed "grab" samples and cutting re latively
undisturbed "block" samples from within each test pit. The samples were placed in sealed plastic bags and
containers prior to transport to the laboratory.
The subsurface soils encountered in the test pits were logged and described in general acc ordance with ASTM1
D-2488. Soil samples were collected as described above, and were classified in the field based upon visual and
textural examination. These field classifications were supplemented by subsequent examination and testing
of select samples in our laboratory. Graphical representations of the subsurface conditions encountered are
presented on each individual Test Pit Log, Figures 2 through 5, included in the Appendix. A Key to Symbols
defining the terms and symbols used on the logs, is provided as Figure 6 in the Appendix.
When backfilling the test pits, only minimal effort was made to compact the backfill and no compaction
testing was performed. Thus, settlement of the backfill in the test pits over time should be anticipated.
1American Society for Testing and Materials
Preliminary Geotechnical Engineering Study Page 5
Maslonka Property – Boise, Idaho
CMT Project No. 13175
3.0 LABORATORY TESTING
Selected samples of the subsurface soils were subjected to various laboratory tests to assess pertinent
engineering properties, as follows:
1. Moisture Content, ASTM D-2216, Percent moisture representative of field conditions
2. Atterberg Limits, ASTM D-4318, Plasticity and workability
3. Gradation Analysis, ASTM D-1140/C-117, Grain Size Analysis
Laboratory test results are presented on the test pit logs (Figures 2 through 5) and in the attached Appendix.
4.0 SITE CONDITIONS
4.1 Surface Conditions
At the time the test pits were excavated the site consisted of two adjacent fields vegetated with grain and
some grasses and weeds. The site grade sloped downward to the south with an overall gradient of about 5 to
10 feet. Based upon aerial photos readily available online dating back to 1993, the site appears to have been
fields since that time. The site is bounded on the south by Amity Road and on the west by Linder Road (see
Vicinity Map in Section 1.1 above).
4.2 Subsurface Soils
At the locations of the test pits we encountered approximately 4 to 6 inches of topsoil at the surface.
Natural soils were observed beneath the topsoil/fill soils, consisting of light brown SILT (ML) with caliche
extending to depths of about 5 to 6 feet below the surface. Natural, light brown coarse SAND (SP) with gravel
and cobbles was encountered extending to the full depth penetrated, 10 feet.
The silt soils were slightly moist brown in color, and estimated to be medium stiff in consistency.
The natural sand soils were moist, brown in color, and estimated to be medium dense to dense.
For a more descriptive interpretation of subsurface conditions, please refer to the test pit logs, Figures 2
through 5, which graphically represent the subsurface conditions encountered. The lines designating the
interface between soil types on the logs generally represent approximate boundaries - in situ, the transition
between soil types may be gradual.
Preliminary Geotechnical Engineering Study Page 6
Maslonka Property – Boise, Idaho
CMT Project No. 13175
4.3 Groundwater
Groundwater was not encountered at the time of our field explorations within the maximum depth explored
of about 10 feet below the existing ground surface. Therefore, groundwater is not anticipated to affect
proposed construction.
Groundwater levels can fluctuate as much as 1.5 to 2 feet seasonally. Numerous other factors such as heavy
precipitation, irrigation of neighboring land, and other unforeseen factors, may also influence ground water
elevations at the site. The detailed evaluation of these and other factors, which may be responsible for
ground water fluctuations, is beyond the scope of this study.
4.4 Site Subsurface Variations
Based on the results of the subsurface explorations and our experience, variations in the continuity and nature
of subsurface conditions should be anticipated. Due to the heterogeneous characteristics of natural soils, care
should be taken in interpolating or extrapolating subsurface conditions between or beyond the exploratory
locations.
Also, when logging and sampling of the test pits was completed, the test pits were backfilled with the
excavated soils but minimal to no effort was made to compact these soils. Thus, settlement of the backfill in
the test pits over time should be anticipated.
5.0 LIMITATIONS
The recommendations provided herein were developed by evaluating the information obtained from the
subsurface explorations and soils encountered therein . The exploration logs reflect the subsurface conditions
only at the specific location at the particular time designated on the logs. Soil and ground water conditions
may differ from conditions encountered at the actual exploration locations. The nature and ex tent of any
variation in the explorations may not become evident until during the course of construction. If variations do
appear, it may become necessary to re-evaluate the recommendations of this report after we have observed
the variation.
Our professional services have been performed, our findings obtained, and our recommendations prepared in
accordance with generally accepted geotechnical engineering principles and practices. This warranty is in lieu
of all other warranties, either expressed or imp lied.
We appreciate the opportunity to be of service to you on this project. If we can be of further assistance or if
you have any questions regarding this project, please do not hesitate to contact us at (208) 912-1868
SUPPORTING
DOCUMENTATION APPENDIX
Date:
Job #
Maslonka Property Figure:1Northeast Corner of Linder Road and Amity Road Site Plan 0-Jan-00
13175
N
TP-1 TP-2
TP-3
TP-4
TOPSOIL, brown silt with vegetation
Light Brown SILT (ML), with caliche
grades to cemented caliche hard
Light Brown Coarse SAND (SP), with gravel and cobbles
END AT 10'
Remarks:
Excavated By:
Logged By:
Page:
Date:
13175NE Corner Amity & Linder 10'
(see Remarks)
8/23/19
Gradation Atterberg
Job #:
TP-1
Soil Description
Surface Elev. (approx):
Equipment: Rubber Tire Backhoe
Maslonka Property Test Pit Log
Total Depth:
Water Depth:
Lou Watts
Inselman Excavation
Groundwater not encountered during excavation.Figure:
21 of 1
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28Depth (ft)GRAPHICLOGSample TypeSample #Moisture (%)Dry Density(pcf)Gravel %Sand %Fines %LLPLPI
TOPSOIL, brown silty sand with vegetation
Light Brown SILT (ML), with caliche
Light Brown Coarse SAND (SP), with gravel and cobbles
grades with fine to medium sand
END AT 11'
Remarks:
Excavated By:
Logged By:
Page:
Groundwater not encountered during excavation.Figure:
3Inselman Excavation
Lou Watts
1 of 1
Soil Description
Gradation Atterberg
Water Depth:(see Remarks)Job #:Surface Elev. (approx): NE Corner Amity & Linder Equipment: Rubber Tire Backhoe
13175
Total Depth:11'Date:8/23/19
Maslonka Property Test Pit Log TP-2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28Depth (ft)GRAPHICLOGSample TypeSample #Moisture (%)Dry Density(pcf)Gravel %Sand %Fines %LLPLPI
Brown Silty SAND (SM)
grades with caliche
grades to cemented caliche
Light Brown Medium to Coarse SAND (SP), with gravel and cobbles
END AT 10'
Remarks:
Excavated By:
Logged By:
Page:
Maslonka Property Test Pit Log TP-3
Surface Elev. (approx): Water Depth:NE Corner Amity & Linder Equipment: Rubber Tire Backhoe Total Depth:10'Date:8/23/19
Soil Description
Gradation Atterberg
(see Remarks)Job #:13175
Groundwater not encountered during excavation.Figure:
4Inselman Excavation
Lou Watts
1 of 1
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28Depth (ft)GRAPHICLOGSample TypeSample #Moisture (%)Dry Density(pcf)Gravel %Sand %Fines %LLPLPI
TOPSOIL, brown clayey sand with vegetation
Brown Clayey SAND (SC)
Brown Medium SAND (SP), with caliche
grades with medium to coarse sand
grades to cemented caliche
REFUSAL AT 6.5'
Remarks:
Excavated By:
Logged By:
Page:
Maslonka Property Test Pit Log TP-4
Surface Elev. (approx): Water Depth:NE Corner Amity & Linder Equipment: Rubber Tire Backhoe Total Depth:6.5'Date:8/23/19
Soil Description
Gradation Atterberg
(see Remarks)Job #:13175
Groundwater not encountered during excavation.Figure:
5Inselman Excavation
Lou Watts
1 of 1
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28Depth (ft)GRAPHICLOGSample TypeSample #Moisture (%)Dry Density(pcf)Gravel %Sand %Fines %LLPLPI
Date:
Job #:
Gradation
⑧
① ② ③ ④ ⑤ ⑥ ⑦
MODIFIERS
Description Thickness Trace
Seam Up to ½ inch <5%
Lense Up to 12 inches Some
Layer Greater than 12 in.5-12%
Occasional 1 or less per foot With
Frequent More than 1 per foot > 12%
Note: Dual Symbols are used to indicate borderline soil classifications (i.e. GP-GM, SC-SM, etc.).
Maslonka Property Key to Symbols
(enter location)Farrer Excavation
13175
Soil Description
Atterberg
⑨
COLUMN DESCRIPTIONS
①Depth (ft.): Depth (feet) below the ground surface (including
groundwater depth - see water symbol below).⑨Atterberg: Individual descriptions of Atterberg Tests are as follows:
②Graphic Log: Graphic depicting type of soil encountered
(see ② below).
LL = Liquid Limit (%): Water content at which a soil changes from
plastic to liquid behavior.
③Soil Description: Description of soils encountered, including
Unified Soil Classification Symbol (see below).
PL = Plastic Limit (%): Water content at which a soil changes from liquid
to plastic behavior.
④Sample Type: Type of soil sample collected at depth interval
shown; sampler symbols are explained below-right.
PI = Plasticity Index (%): Range of water content at which a soil exhibits
plastic properties (= Liquid Limit - Plastic Limit).
⑤Sample #: Consecutive numbering of soil samples collected
during field exploration.STRATIFICATION MOISTURE CONTENT
⑥Moisture (%): Water content of soil sample measured in
laboratory (percentage of dry weight of sample).
Dry: Absence of
moisture, dusty, dry to
the touch.
⑦Dry Density (pcf): The dry density of a soil measured in
laboratory (pounds per cubic foot).
Moist: Damp / moist to
the touch, but no visible
water.
⑧
Gradation: Percentages of Gravel, Sand and Fines
(Silt/Clay), obtained from lab test results of soil passing the
No. 4 and No. 200 sieves.
Saturated: Visible water,
usually soil below
groundwater.
②TYPICAL DESCRIPTIONS
COARSE-
GRAINED
SOILS
More than 50%
of material is
larger than No.
200 sieve size.
GRAVELS
The coarse
fraction
retained on
No. 4 sieve.
CLEAN
GRAVELS GW Well-Graded Gravels, Gravel-Sand Mixtures, Little or
No Fines
SAMPLER
SYMBOLS
(< 5% fines)GP Poorly-Graded Gravels, Gravel-Sand Mixtures, Little
or No Fines Block SampleGRAVELS WITH
FINES GM Silty Gravels, Gravel-Sand-Silt Mixtures
Bulk/Bag Sample
( ≥ 12% fines)GC Clayey Gravels, Gravel-Sand-Clay Mixtures Modified California
Sampler
SANDS
The coarse
fraction
passing
through
No. 4 sieve.
CLEAN SANDS SW Well-Graded Sands, Gravelly Sands, Little or No
Fines 3.5" OD, 2.42" ID
D&M Sampler(< 5% fines)SP Poorly-Graded Sands, Gravelly Sands, Little or No
Fines Rock CoreSANDS WITH
FINES SM Silty Sands, Sand-Silt Mixtures Standard
Penetration Split
Spoon Sampler( ≥ 12% fines)SC Clayey Sands, Sand-Clay Mixtures
FINE-
GRAINED
SOILS
More than 50%
of material is
smaller than No.
200 sieve size.
SILTS AND CLAYS
Liquid Limit less than 50%
ML Inorganic Silts and Sandy Silts with No Plasticity or
Clayey Silts with Slight Plasticity
Thin Wall
(Shelby Tube)
CL Inorganic Clays of Low to Medium Plasticity, Gravelly
Clays, Sandy Clays, Silty Clays, Lean Clays
OL Organic Silts and Organic Silty Clays of Low Plasticity
SILTS AND CLAYS
Liquid Limit greater than 50%
MH Inorganic Silts, Micacious or Diatomacious Fine Sand
or Silty Soils WATER SYMBOL
CH Inorganic Clays of High Plasticity, Fat Clays Encountered Water
LevelOHOrganic Silts and Organic Clays of Medium to High
Plasticity Measured Water
LevelHIGHLY ORGANIC SOILS PT Peat, Soils with High Organic Contents (see Remarks on Logs)
1. The results of laboratory tests on the samples collected are shown on the logs at the respective sample depths.
2. The subsurface conditions represented on the logs are for the locations specified. Caution should be exercised if interpolating between or extrapolating
beyond the exploration locations.
3. The information presented on each log is subject to the limitations, conclusions, and recommendations presented in this report.
Figure:6UNIFIED SOIL CLASSIFICATION SYSTEM (USCS)MAJOR DIVISIONS USCS
SYMBOLSDepth (ft)GRAPHIC LOGSample TypeSample #Moisture (%)Dry Density(pcf)Gravel %Sand %Fines %LLPLPI