Loading...
HomeMy WebLinkAboutPZ - Site Plan ■ Q O U CUP SITE PLAN FOR = oM0 a r_ II iI iI Ij I IIj 1 1 LEGEND -- -- = wNA JUMP CREED SOUTH APARTMENTS or ~ co.BOUNDARY PI PI PI PI b LOT LINES LOCATED IN THE SE 1/4 OF THE SE 1/4 OF Z 3 a - PI PI THE SE 1/4 OF SECTION 28RI PI - � = 1 I I ' ROAD CENTERLINE - - T R B Z , .4N. .1W., B.M. g RIGHT OF WAY MERIDIAN, ADA COUNTY, IDAHO I I 2020 d L----- J ' -W W - - w i i W 01 3 ,--- LOT NUMBER O1 �JJ o A w ----- Hill �I LOT AREA PI PI w 5 6,500sf = Z w , IIII H I w w T�I--I E S T. __ _ w i I I EP — ................................... wow— JUMP CREEK ul to BLOCK NUMBER BLOCK 7 ja w w w �I DAPHNE ST_ _ - - — SUBDIVISION NO. 1 - °° ____ h EASEMENT �++ w _ _S _ - s ---------------- � [EXISTING] Yil m NEW CHAIN LINK FENCE - Z s s s s s --- II Illllal I EP j _ ° iliiii 3 CURB GUTTER SW W Q co cc of I STREET NAME W. ASHTON DR. I� EXISTING 8" °°II Wii HANDICAP RAMP - T-9 j w W BLOCK O SEWER & WATER ----- cn Lp, 3 0 2 O 1 1113 I SEWER LINE • • JUMP V w Ir P� PI ---- 61.78—P' PI —N89° 8'27"W 7.85 PI PI—r PI jll d III I WATER LINE —w—w CREEK (� -- ----- S84°4016 a I 0 I == ==== EXISTING ACHD O sue— - 3 STORM DRAIN LINE aa— N0. 1 a • STORM DRAINAGE -o __ ------ / _ 24-- ----- --------i- o III i t - EXISTING ACHD 3 ® t i PRESSURE IRRIGATION FACILITY r- JUMP S�pNAL FN STORM DRAINAGE _ • - ' 25' _ __J ` N90°00'00"W 73.00 CREEK �CJ Gj - \ I -- - GRAVITY IRRIGATION BLACK CAT \STE FACILITY ASo I r h N 0. 5 p �G BUILDING L -�- a- 1 I II ill FLOW ARROW ESTATES N0. Q- p c<` (q� 02 Q 03/21/2023-- IJ I I: ® `� FIRE HYDRANT K - -- _ -- I: BUILDING I �1- BUILDING A —p -- R l- ---� PI PI PI 1 TYPE 2-2 J-�- : i II - II w SURFACE I BUILDING I 1 -- _ r--------------------- zso7 sf elDc `::'::: :?` N-I - I I i TYPE 2-2 I - I''I CATCH BASIN �y8( 82 DRAINAGE FOOTPRINT I H 1 / I' ' II 31 III 2,507 sf BLDG I E I SWALE I I I I p 1 STREET LIGHT a 9 Y _� V FOOTPRINT H -- - L _ a / I s i i 7' I - �. . o a III i1 / JUMP /j- F OF \ No CREEK BLACK CAT _ O I 17� 2 L 7 A A / Y ESTATES N0. N SNO. 6 . C 01 m O 31 \ 30 ----------- I I D ' -1 o L . s �— r »»> r ' CHECKED BY: o . DAVID A. BAILEY P.E. - I r--------------------1 r-- ?: :; -� I�TI --- Ro 81i i' McMILLAN RD DRAWN BY: DAB KSC s I j s BUILDING K / BUILDING r-- --J _ SOUTH \ _ (;;::: f 0 I AKCREE OAKCREEK -i------ I -- --+ O zTYPE,507 sf BLDG _ i_ Lam/ 35' UTILITY m 1 N0. 03 ONO. 02K NO. 01 PROJECT .......... F I FOOTPRINT —}— O I s I _L Z rn I f -* EASEMENT \ ill IIII SITE O I ^ I I v C a I I C,a ::::1: I: : 3 I I - - : r � I I J I __ - r Lj �I w::i:i L - �j�( � 2,393 sf BLDG I � IPI I FOOTPRINT I; ----------- -j- L'- I OAKCREEK Z --------- � BUILDING B I P'I.1 —� — _ N0. 03 - - U U IIII — I i BUILDING I Q F I• I �♦ I uo I r I �. . . TYPE 2-1 N I' ' III III _ f v ull I 81.'... o I - Z Ld Y JUMP CREEK I III V � II I SUBDI ISION N0. 6 I 2 I I _ C9_ I 1 H ::::: f _ II I I w ............... =- m [IN DEVELOPMENT] o f ° N o-; �`� 3 a Of z S I --------- II- f : °i o v�' � TRASH ENCLOSURE - i i 1v U SURFACE 11 �cb I ' - yy I s -o l�� i i LOCATION i. Y i > Z o vvi I L— ---------------J n DRAINAGE f r--------------------� - _ SWALE F 7 7--r-r,'I I o vi : IO I I �� I 81 I I I SURFACE DRAINAGE N N r•7 I - . z I I J I I I \ I BUILDING C jl I SWALE — H o N N N o I I, BUILDING a N o l I N I 1 I: : I N N � I Q I I I I - o N ✓n I I I s 0 I TYPE 2 2 I ' I I __ I I o II I I > 2,507 sf BLDG I• I IIII Lu O 1 N I I N O I N N ............ "`: I v - - f --- 00 f I FOOTPRINT 1 I� BUILDING J I' ' I � z 2 I I I I- � 11 1 N M � � � O I < I BUILDING III. s I I _ . M s TYPE 3-1 -i i: :: - i' w VICINITY MAP I >. ' I I 2,507 sf BLDG II I 1 I _ L ---------J I -L_ - �:: N A I ------- FOOTPRINT _ ::: L_ `Y W o I 0 1" = 500' • _ _ : -t/t i � 1 A I I s1!18 --_ 00 0° ' `'` I 0 DEVELOPMENT FEATURES SITE FEATURES 3 3 I r� SUBSURFACE 2 ACREAGE BUILDINGS _ o: A 5 ` - ------ I I VERTICAL � _I-- -- -- ___- --J _ � i - 48' I I I Ih SAND FILTER I - II I TOTAL PARCEL-3.29 ACRES TOTAL DWELLING UNITS-44 _-______ � [DRAINAGE] BUILDING D i 3 TYPE 1 UNITS (2 BEDROOM)-6 L--------- DRAIN yy 0 17 25' r- - L . I I � II° �L. o..°� _�_ L s BUILDING I TYPE 2 UNITS 2 BEDROOM -3 r ® I 17" > TYPE 2-1 ZONING ( ) - a 25 � ? r--------------------� s I :::: I v r _ HI TYPE 3 UNITS (3 BEDROOM)-2 _ _ _ _ z,393 sf eIDG I 5' rl III EXISTING - R-15 2,507 sf BLDc FooTPRINT II I� I PROPOSED- R 15 I I NEW ACHD � r— I �I PARKIN BUILDING H ..... w-� / II I SIDEWALK G =_= N - o I' li REQUIRED SPACES: 94 LEASING BUILDING I --� o I: :' A _ SEWAGE DISPOSAL \o ti I I OFFICE TYPE 2-1 -�- -_-- cn III 3 II SPACES PROVIDED: 100 Z L --- -- o i 11 11 ii I MERIDIAN CITY SEWER ADA SPACES REQUIRED: 2 s .: ! I I IIII ADA SPACES PROVIDED: 2 I , I W o I '` I s I I - - WATER SUPPLY BICYCLE STALLS REQ:4 ' v I ':: I: . � I I m r I ----------------1 .......:::::::::.:::::........................ 00 MERIDIAN CITY WATER BICYCLE STALLS PROVIDED IN CARPORT C I PRIVATE I� of o II I \ SEE ARCHITECTURAL SITE PLAN CITY OF MERIDIAN I�` ��� I I \ [ l I o __ _ ... --4i ---- ----------- _ — — -- NEW ACHD ROW LINE I \ 1..... 5 r \ "` UTILITY EASEMENT I I I � 3 I CITY ',II ST. iiii col W �� W W �� ' W -- - - - i �' li MERIDIAN CITY TRASH �,, lUILDING E I N WATER \ BUILDING a h I a �Qe " - - III ONE SCREENED ENCLOSURE y ii iiii a s Tn I DR. N SEW _ i TYPE 2-2 I s e \\\ �I • •� I �' z,so7 sf BLDc r. SCHOOL DISTRICT 0 FOOTPRINT I _ I IW I \ 1 1 1 ................................ "`J`"" I I :::::::::. ::::.:.4i}i}: iP':::::::::::.::: ::::.:::::::::.............. .. ................... I ....... A m III >ul MERIDIAN SCHOOL DISTRICT#2 I - I I FIRE ACCESS I CC SS 4.. .. t .....:a .:. _ I r l�l 1 I I 1 �d•.::;i;; I. . EXISTING USERS Fill o 71 1 Q GIRR LINE TO BE ALL CURVES MIN 28 INSIDE/48 OUTSIDE. -- _---- I -� I. PROTECTED , 'I FIRE DISTRICT ' - ,� �. .. w ROW TERMINATION .,.,,. �:.;.. r :. :`< :;: 1::':':; ;;{ o A A I II' " s / 8" SEWER & WATER TO �...:.... :r N V OF PRIVATE STREET —�'-� I � ��„�� ':::: ����1\\\ i i �, i I 1'�i�l II(��I' I II i iIl � �� 2"1/2 ASPHALT MERIDIAN AMENITIES o COVERED PICNIC SHELTER W/TABLES& BBQ \ BE CONSTRUCTED WITH 4 OF 3 4 MINUS CRUSHED / r ,L BUILDING F IEXISTING CREASON JUMP CREEK SUB N0. 6 qe BUILDING G y ^' AGGREGATE RAISED BED GARDENS BUILDING .. J LATERAL OVERFLOW I I� IRRIGATION DISTRICT ' TYPE 2-1 PROTECTED i1 " " SETTLERS IRRIGATION DISTRICT I , I � BUILDING G-IRR LINE TO BE OF BICYCLE REPAIR STATION LLI s JUMP CREEK , , TYPE 2-2 2,393 sf BLDG 28I 29 3u SUBDIVISION NO. 6 I �� FOOTPRINT ., ,' O O 14" OF 6" MINUS PIT RUN MINUS PIT RUN (PARKING) I F 1 i �::::� o'I� I III 3 o _ I \ oe ,NEW P—IRR UNE o0 00 SIGNS 0 = N A [IN DEVELOPMENT] 1- i11 (APPROACH AND STREET REPAIR) ` I III SEE LANDSCAPE PLAN FOR DETAILS I s L s 2s \v = �� / o o ? III PRIVATE ROAD SECTION --- -+-----� L / NOT TO SCALE LIGHTING A ' ' � • ��� )' ; ' / ~III� r f g -SHIELDED PARKING AREA LIGHT STANDARDSp q R p AZp ----------- -��\--- ~ \\ EXISTING CREASON .' 40 0 20 40 80 o \. `LATERAL EASEMENT II y11 - LIGHTS AT ENTRIES ON EACH BUILDING ooi l l n -� z Q R ,'���'T�� �11 SCALE IN FEET J� / IR IR IR ` IR'V IRR IR RR IRR \\ \O \ �g'\ \\ 17) / I O IRR IR \ : N ;�' \ \`\\ /' :`> ' ' IN 1 =40 OWNER SURVEYOR NOTES: 0 \ 1 NEW ACHD ROW LINE � � / I 1. STORM DRAIN WATER FROM PARKING AND BUILDINGS WILL BE ROUTED TO SURFACE DRAINAGE PONDS/SWALES. ALL EXISTING CREASON ���� �` I I I � OPEN DOOR RENTALS LLC IDAHO SURVEY GROUP .............:::::::::::::.............,::::.::.::::.::::....................................... J \ � � � I \� STORMWATER RUNOFF TO BE RETAINED ON SITE. .......:.......... ...................................................:::::::............................................................:.:::::::::::::::::::::::::::::::::::................................::....................... _ r - ... 1977 E OVERLAND RD 9955 EMERALD ST. LATERAL G IRR LINE o _ ......................................................... LA E . �:. w .................... "—'L=-==—" L_ — - MERIDIAN, D 83642 2 TO ASSESSMENTS OF THE SETTLERS IRRIGATION DISTRICT DEVELOPER TO PROVIDE . ............ .... TO BE PROTECTED I x N, I BOISE, ID 83704 THIS SUBDIVISION WILL BE SUBJECT .. .............. .... ...... . .. .......... ____ ` t----3- , -soe -- \ 46-8570 PRESSURE IRRIGATION SERVICE(S). —..—..—..—..—.. --.- .- ,_ ---------- DEVELOPER EP -----EP EP EP EP Ep EP_— -------- pJ o 0 _-w w w w w w w — w eg EP w EP w EP w EP TI/ II 3. SLOPE OF SITE IS SUFFICIENT TO PROVIDE MINIMUM 0.4/o GRADE AT ALL GUTTER FLOW LINES AND 1/o ACROSS ASPHALT ^' NEW ACHD -- w - w w— TRILOGY DEVELOPMENT ARCHITECT SURFACES. 1'ir SIDEWALK \ //ill SHAWN BROWNLEE THE ARCHITECTS OFFICE Fill \-'2g -W542 M cM I LLAN R D I \ - _---- 9839 W CABLE CAR ST., SUITE 101 MATT RHEES 4. THE SUBJECT PROPERTY DOES NOT FALL WITHIN ANY FEMA FLOOD HAZARD ZONE. REFERENCE FIRM PANEL - I EP EP EP " \ /r'r/ /I BOISE, ID 83709 499 MAIN ST. 16001C0139J EFFECTIVE 06/19/2020 0 EP —f� -------- -- �,------_—_—' EP - - \ _ ---- - i (208)895-8858 BOISE, ID 83702 EP - x x x % /// = = __' WITH THE APPLICABLE STANDARDS OF THE CITY OF _ 5. MINIMUM BUILDING SETBACK LINES SHALL BE IN ACCORDANCE /i/� '/''r''r/i= _= =�_a --- OP �� ----------oP oP OF _ _ _ _ __ /y r r r� (208)343-2931 MERIDIAN AT THE TIME OF ISSUANCE OF THE BUILDING PERMIT. _------- - -----------°9 OF e \\ \` ======__-= ' ENGINEER DATE: ---- _ 10-14-20 KEVIN S. CRAIG, P.E. i I--------- BAILEY ENGINEERING, INC. PROJECT: IE =1 I 1] C2013-024 1119 E STATE ST., SUITE 210 EAGLE, ID 83616 SHEET (208)938-0013