Loading...
HomeMy WebLinkAboutCC - Site Plan - Preliminary Plat 6� Legend SUBDIVISION BOUNDARY c p COI \\\ M \ ,/ LOT LINE a W \\ _ _ = - - = - - = - = = = - = ='ii �� / i HI. 11 30 0 30 - - - STREET CENTERLINE `p 0 / - - SECTION LINE r /Ex-w p N HORIZONTAL SCALE: 1"=30' V/ 5 N o I-M-X3M-X3M-X3M-X3M-X3M-X3NrX3M-X3 M-X3M-X3M-X3-M-X3 M-X3M-X3M-X3M-X3M-X3 M-X3M-X3 M-XBM-X3 III EXISTING MANHOLE EXISTING FENCE o N00'09 45"E 444.16' \\ RIM=2569.65 C 0 0 0 0 o- m ` - -- - - -aQ - txo ---q > �W IN (E)=2563.77 -EEP EEP EEP EEP EXISTING EDGE OF PAVEMENT Z $ �p C a - - - - - - - - - - - - - - - -- - - - - FYTIG 8" PV // / OUT N -2563.67 55-X3-55-X3SS-X3SS-X3SS-X3SS-X355-X3 55-X3SS-X3SS-%355-X355-X3 SS-X3SS-X3SS-X355-X3SS-%355-X3SS-% S- / ( ) C 0 +� o m \ t�. // EOP-EOP-EDP-EOP- NEW EDGE OF PAVEMENT m N of cv r \A , �' .1 Z - = - = = = - = = = _ _ _ _ _ N. Chimney Peak Ave. _ - - ' \'�,, �,X\� % / GONG GONG GONG CGNG J ,; " """ w / / m ( EDGE Of CONCRETE (J 4 3 - - - - - - - - - - - - - - - - - - - - - - - - \� Ii - - - EXISTING CURB AND GUTTER aJ \ \\ FOUND /2" PIN, NO CAP. REPLACED I > 3 WITH 5/ "1 IRON PIN WITH PLASTIC m -EX-Ss EX-Ss Ex SS EX-SS- EXISTING SANITARY SEWER MAIN LINE O bO Q \ \ w z o% / • CAP LAB LED "CENTURION LS 4116" � ) 1 M, 00 \ / Delta=34'23'45" \ L -ss-ss-ss-ss-ss- CONSTRUCT SANITARY SEWER MAIN LINE, SIZE NOTED w H M 1 I Radius-52.00' N CONSTRUCT 4" TYPE "C" SEWER SERVICE PER ISPWC wj own m III III Arc=31.22' \ SD-511, SEE DETAIL 3, SHEET 8 N M Chord Bearing=S12'43'O6"E w / a M III I Chord Distance=30.75' " Iti I \ s` I m I Ex-w -w -w -w EXISTING WATER MAIN LINE o m O III CNN o \\ It I -w w-w-w-w- CONSTRUCT WATER MAIN LINE, SEE SHEET 3.2 FOR SIZES V u N N III I o I I o \\ I CONSTRUCT WATER SERVICE PER CITY OF KUNA SD-K401.75 III i r III Hgffi w PIRR PIRR-PIRR-PIRR- EXISTING PRESSURE IRRIGATION MAIN LINE tiO PIRR-PIRR-PIER-PIRR- CONSTRUCT PRESSURE IRRIGATION MAIN LINE AC 14) 1 I I � I NN w do \ I I CONSTRUCT X" GRAVITY IRRIGATION MAIN LINE H Z GIRRGIRRGIRRGIRR III 8 IH I �� A ? I roe roe-TDB Toe EXISTING TOP OF BANK \ III I /1 z L \ FulTB Sub:No.6 a ) EXISTING FIRE HYDRANT I 1 II III I ti Iw �" EXISTING GRAVITY V `� I DQ EXISTING WATER VALVE III / I Fulfe Sub.No.6 I I I IRRIGATION BOX, TO BE lz III o \ EW EXISTING WATER METER RETAINED AND PROTECTED \ m N III I III aala Mid aaid aam-ama ama gala aala aala aala aala • ama-ama aura SOO'09'45"W 153.fi2' Id .s�did am� IS•-I-a aia aald aala-S�O`09'45"W 116. 8'-aald aala ( I I ❑T EXISTING TELEPHONE RISER w NAL• tJ E .6 -- -'EEP-P <_� 53:96T • • _ _ _ • I I I EEP-- EEP- EEP EEP kidm i w d33 -�daa -d33_a33 L a� i I a �Q, EXISTING UTILITY POLE z it¢ 4i �/ / 5. �n o 9 I a33 -d33 -a33 -- V^\4 I EXISTING STREET SIGN Q Z o j LLV III , R$ '� ,n ,ri M" W S I m o 0 6 I � o 0 o APPROXIMATE LOCATION a II j /ryy EXISTING SHEDS, TO BE OI" OF EXISTING SERVICES w EX EXISTING LED STREET LIGHT N m � I � w� w Y � V1 J O t-`w w E`' `�`(�� RETAINED AND PROTECTED 8,500 SF ) LOT NUMBER ¢ Z m? Sj,O�I�Q U S00'09'45"W 60.00' / S E -- EEP P - EEP EEP- EEP- EEP H EEP EEP EEP- EEP E "U 55 55 �' (n = O Q U EEP EE + m ss EXISTING SANITARY SEWER MANHOLE II 8,059 SF �) 1- m x I +II I ' � -2570 ® INSTALL SANITARY SEWER MANHOLE E v EXISTING WELL AND a° EXISTING TOP OF BANK Q w w III I - �/ APPURTENANCES, TO BE M p p + " \ RELOCATED AS NEEDED. I R EXISTING GRAVITY IRRIGATION BOX \\l � i, v 3 , � -� I • SET 1/2"X24" IRON PIN WITH PLASTIC CAP z o Q �s o N00109'45"E 116.38' �. I I LABELED "CENTURION LS 4116" o o / o " I i \� I SET 5/8"X24" IRON PIN WITH PLASTIC CAP LABELED "CENTURION LS 4116" 0 o � o w h" I o ��N s n I 3 0 vi ZT LLYy 1 ( 8A59 SF _ _2570 - l o C�Cf m x _ cn / emu"6_ I w o EXISTING IRRIGATION f I I w 3 - 29,82233 SF v BOX, TO BE RELOCATED/ `r;: I o - _ z :x AS NEEDED // b � .rLJ YOf Vicinity Map v p a 0' 116.38' P-i m `t �U _y .__ 1 u._�i . r �gzzo a d I y N00'09'45"E 140.38' // F _ i - _ _i -� w III xC` w•,- I -T ( j �- '� �.. O ¢ aw III I w o m i__ - ,� ` -'--_ I I I I I I -1 / � p z 77 .... 1 Z Y p p (I I ))I I o �� \ EXISTING GRAVITY r 8,633 SF �� �.I 0 0 / co IRRIGATION BOX, TO BE e �� z > m - cv III 1 aald-ama aaldaalaaaldaalaaald-gala ama-gala-ama-ama aald -, ) y ,d. I I •E .,-� JI -�.1 (- \ __.I - I _ d p z r� RETAINED AND PROTECTED ,f�� EXISTING IRRIGATION t a _-� o T rn _ Z _ I BOX, TO BE RELOCATED �' ���' m NOT TO SCALE __.__� --.-- _) 1 _ ( � z o 1 �, Z = � III z 2570. e NEEDED �i en `'� ��� o �,„ I I . {' 1i '.__I--�-' �--EAPGARCR_EEK.DR. ._� i�-- -_- - -.._ �"' I 130U � �„ 257 II I z� / / /` o. I � -- p GAR CREEK DR. w O w III • '/ /,�. � � �� � ---li pil - - - ��-� �- TI- � 1 .� Q � ow ,� �1 �� E.SPRINGS CT 3 1ZII I ¢ O Fulfer Sub No.4 " • X' i r I �r - - z , N00'09'45 E 300.Ob N00'O9 5 00 r - -_ Fh7fer0nb.No.4 � f- �� � 11 - I � '`NI,__- ml � i _ Jo\- m l D STONE SI' NI I { McMILLAN 12D. . ....---- 01 I I 1 ~ zl I -1 E ' ..--� - _- ...... cMILLAN RD _ -- Project TIT m N Location -.L�� o - v vvv v vvv v l T Q�j 1 1 - v �v v v" \ r r - �\ i I L_�) � ......�-. ! t - - - _ _ _ _ _ _ _ _ _ _ _ - - - - - - - - - ii/ /TT - /�\' \\\ I N. Wild Goose Way '�v � ' (� 1 w -- - � - - -- - - - - - - - - - - - - - - - --- Ld � Private Drive Cross Section Setback/Zoning Table Land Use Calculations Underground Utility Note Notes NOT TO SCALE DESCRIPTION AREA (ACRES) PERCENTAGE THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM 1. THERE ARE NO POTENTIALLY HAZARDOUS AREAS. 13. EXISTING IRRIGATION FACILITIES TO BE CONTINUED TO THEIR HISTORIC EXISTING ZONE R-8 FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE 2. THERE ARE NO STREAMS, PONDS, LAKES, OR WETLANDS ON THIS DISCHARGE POINTS. 24.0' PROJECT 2.75 100% SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND MINIMUM LOT AREA - INTERIOR LOT 4,000 SF PROPERTY. 14. THIS PROPERTY IS CURRENTLY ZONED R-8. FRONT YARD SETBACK TO GARAGE 20 FEET RESIDENTIAL LOTS 1.69 61.47 UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA 3. THERE ARE NO NATURAL DRAINAGE SWALES ON THIS PROPERTY. 15. EXISTING USE: SINGLE FAMILY RESIDENCE. EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER k 12.0' 12.0' FRONT YARD SETBACK TO LIVING AREA 10 FEET PRIVATE DRIVE LOTS 0.39 14.37 DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN o 4. THERE ARE NO PERMANENT AND/OR SEASONAL HIGH GROUNDWATER 16, CONTOUR INTERVAL: 2 FOOT DATUM: NAVD 88 ° 3 REAR YARD SETBACK 12 FEET ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES AREAS ON THIS PROPERTY. w o z c CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE 17. THE PRIVATE DRIVE AREA SHOWN HEREON SHALL BE MAINTAINED BY THE o z 3i1 TO STREET SIDE YARD SETBACK 20 FEET RESIDENTIAL LOTS 4 5. THIS PROPERTY IS NOT IN A FLOOD PLAIN AREA. HOMEOWNERS' ASSOCIATION. 3:1 TO 2.009 MINIMUM 2.00%MINIMUM FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT 'b rm EXISTING EXISTING INTERIOR SIDE YARD SETBACK 5 FEET PRIVATE DRIVE LOTS 1 PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. DEVIATIONS 6. THERE ARE NO IDENTIFIED SHALLOW BEDROCK AREAS, UNSTABLE ROCK 18. THIS DEVELOPMENT ANTICIPATES USING SUBSURFACE STORM WATER ¢ did = o - c, GROUND GROUND MAXIMUM BUILDING HEIGHT 35 FEET RESIDENTIAL DENSITY 2.4 UNTT/ACRE MAY EXIST BETWEEN THE LOCATIONS SHOWN HEREON AND THEIR FORMATIONS, OR LANDSLIDE AREAS ON THIS PROPERTY. DISPOSAL OF STORM WATER GENERATED FROM THE LOCAL ROAD SYSTEM ,li z z Y o w o z o ACTUAL LOCATTON(S). AND LANDS TRIBUTARY TO THE SYSTEM. '4 3 " ¢4 w� o> ¢> MINIMUM STREET FRONTAGE 40 FEET 7. THIS PROPERTY IS NOT IN AN AQUIFER RECHARGE AREA. c� e m x O O n O U d 19. PUBLIC UTILITIES ARE TO BE PROVIDED FROM THE PUBLIC UTILITY 8. NO UNSTABLE SOILS SUSCEPTIBLE TO EROSION EXISTING ON THIS PROVIDERS FROM JOINT TRENCH ADJACENT TO THE PUBLIC ROADS. 2 1/2" OF ASPHALTIC CONCRETE PROPERTY. ALL AREAS ARE SUITABLE FOR DEVELOPMENT. SPECIFIC DESIGN CRITERIA WILL BE MET DURING THE CONSTRUCTION SHEET NO: SUB BASE - 10" OF PER I.SP.W.C. SECTION 805. Owner/Applicant 9. SANITARY SEWER SERVICE IS TO BE PROVIDED BY THE CITY OF BOISE. APPROVAL PHASE OF THIS DEVELOPMENT. 6" MINUS PER BASE COURSE - 4" OF 3/4" 10. POTABLE WATER IS TO BE PROVIDED BY THE UNITED WATER. 20. THIS PARCEL LIES WITHIN THE "ZONE X" FLOODWAY PER FEMA MAP O1 I.S.P.W.C. SECTION 801. MINUS PER I.S.P.W.C. COLTON YASINSKI S.P.W.C. SECTION 802. 4853 N. CHIMNEY PEAK AVE. 11. PROPERTY LIES WITHIN THE NAMPA MERIDIAN IRRIGATION DISTRICT. #16001C0143J, DATED JUNE 19, 2020. MERIDIAN, 10 83646 12. PROPERTY LIES WITHIN THE MERIDIAN CITY FIRE DISTRICT. 21. THE FOLLOWING TAX PARCEL NUMBER IS INCLUDED WITHIN THIS SUBDIVISION: R2958270300. (4853 N. CHIMNEY PEAK AVE.)