HomeMy WebLinkAbout2023-03-14 MFD Tamee L. Bilbo
From: Joe Bongiorno <jbongiorno@meridiancity.org>
Sent: Tuesday, March 14, 2023 3:23 PM
To: Bill Parsons
Cc: David Crawford;Tamee L. Bilbo
Subject: FW: Final Plat Approval for Chimney Peak Sub
Attachments: Chimney Peak Site Plan.pdf; Chimney Peak Turnaround Sketch.pdf
Bill here are the approved access plans for the Proposed Chimney Peak sub. Not sure if anyone has been assigned the
project yet.
Joe Bongiorno CFI,CFEI
Deputy Chief—Fire Marshal
Meridian Fire
33 E. Broadway Ave.,Ste. 210, Meridian, ID 83642
(Direct)208-489-0458(Cell) 208-936-9554
Dedication-Loyalty-Tradition
All e-mail messages sent to or received by City of Meridian e-mail accounts are subject to the Idaho law,
in regards to both release and retention,and may be released upon request,unless exempt from disclosure by law.
From: David Crawford<dacrawford@centengr.com>
Sent:Tuesday, March 14, 2023 2:52 PM
To:Joe Bongiorno<jbongiorno@meridiancity.org>;Tamee L. Bilbo<tlbilbo@centengr.com>
Subject: RE: Final Plat Approval for Chimney Peak Sub
External Sender-Please use caution with links or attachments.
Mr. Bongiorno,
Please find attached a sketch of the turn around with the no parking signs and note for the maintenance obligations.
Please note that we did alter the locations of the east and south signs to keep them on our property.
The west most sign was also relocated so it would not interfere with the access to the west most lot.
Sincerely,
David Crawford
Centurion Engineers, Inc.
Phone: 208.343.3381
2323 S. Vista Ave. Suite 206, Boise, ID. 83705
1
Legend
� L
SUBDIVISION BOUNDARY O
Z ro r
LOT LINE - r�
- 30 0 30 - - STREET CENTERLINE vi
III I -
Ex-W *1 ON 111 HORIZONTAL SCALE: 1"=30 SECTION LINE �. N E
P-� o
M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3 M-X3� z III EXISTING MANHOLE ��O O O O ,r EXISTING FENCE L •� �''
���\ �x / RIM=2569.65 Z m
N00'09'45"E 444.16'
- -Oa - - - - - - - - - � ' + IN (E)=2563.77 EEP EEP EEP EEP EXISTING EDGE OF PAVEMENT cfl
SS-X3 ss-X3 ss-X3 ss-X3 ss-X3 ss-Xd ss-X3 ss-X3 ss-X3 SS-XI ss-X3 ss-X3 ss-X3 ss-X3 ss-X3 -SS-X3 ss-X3 ss-X3 ss-- EX Tlx G 8" SPVC3 X3 // / OUT (N)=2563.67 o },
J PO o rn ��� // / I EOP-EOP- EoP-EoP NEW EDGE OF PAVEMENT Z ry N
, - - - - - - - - - - - - - - - - - - - - CD
N. Chimney Peak Ave. _ _sue�'��y ��� \ / CONS CONS CONS CONS J
a - - - - - - - - - - - - - - - - - - - _ _ _ _ �.. w EDGE OF CONCRETE L *'
- - - - - - - - - - - - - - - - - - - - - - - II \� a - - - - - - - - - - EXISTING CURB AND GUTTER Z CU
Nt N FOUND 1/2" PIN, NO CAP. REPLACED I �
_ 10 WITH 5/ %24" IRON PIN WITH PLASTIC EX-SS-EX-SS-EX-SS-EX-SS- EXISTING SANITARY SEWER MAIN LINE O op Q -
\ �\ ;; z o/� / • CO
CAP LAB LED "CENTURION LS 4116" ss-ss-ss-ss CONSTRUCT 4" TYPE "C" SEWER SERVICE CC w Co
Delta=34'23 45 a m bA "� m
Radius=52.00' �ln� N \ EX-w EX-w EX-w EX-w- EXISTING WATER MAIN LINE E >
III i II Arc=31.22' w
Chord Bearing=S12'43'06"E / I -w w w w w CONSTRUCT WATER MAIN LINE, SEE SHEET 3.2 FOR SIZES z - N m
III III Chord Distance=30.75' v�'�� \ I I (J N 00
III I III ti \ 1 CONSTRUCT WATER SERVICE PER CITY OF KUNA SD-K401.75 o m O
I U U N N
III III ;I, I 009 CD \ a 1 PIRR PIRR PIRR PIRR EXISTING PRESSURE IRRIGATION MAIN LINE
CD
1 EW EXISTING WATER METER f
III III I � X /�� \\ I I U INSTALL » LANE" O
III I III ``' TH
Q0 \\ //\\ \\ APPENDIXND OFRTHEG2018E1 AHO FIRE NCODE IN CAND ACHD STCORDANCE ANDARDSCAD
III I III I a, ji z
� \ / \ \ - m I 2 LOT NUMBER
III III �' M
III III ,1 / z I� � / \ � 1 ss EXISTING SANITARY SEWER MANHOLE
/ J \ Fulf! Sub.No.6 I �!
III �„� III gyp. I I I w I \ a I m INSTALL SANITARY SEWER MANHOLE
`""N EXISTING GRAVITY \ `s I Co
III III / I Fulfer Sub.No.6 i I�I X I IRRIGATION BOX, TO BE c'O � a I II EXISTING SANITARY SEWER CLEANOUT
III I �• III NyI RETAINED AND PROTECTED I IR EXISTING GRAVITY IRRIGATION BOX
aald aald aald aald aald aald aald aIHd aald adld aald aald bold / aald- ' " ' Id aid ddl aal a c aald ddld- ' " ' aal aald I » » W
III III • S00°09 45 W 153.62 �� \ • S00'09 45 W 116.$8 • I I SET 1/2 X24 IRON PIN WITH PLASTIC CAP Q Z �p��
III III EPA 97.39 =FEP=EeP � 56.23 I - - - - I • » � o /
o �E EEP- EEP- EEP- � d33 d33 ) I I LABELED CENTURION LS 4116 o w z y
rw N w d33 -d33 -d33 d33 '�33 -��d33 ISET Z Z w¢ O"�O
EOP EOP EOP I I II I 0 LABELED PIN
WITH CAP ¢Z,-
o? �� v
IRON o=
III C� ,�o ,�, $ N APPROXIMATE LOCATION a I m o , ,�„ z •� o
I i cA 111 �`� O I N " OF EXISTING SERVICES w ;} "'
III 1 EXISTING SHEDS, TO BE 8,747 SF LO I o N N m W �� `'� P�
`� RETAINED AND PROTECTED \ J x r z- > S1 Q
?^�1 yI EEP- EEP EEP- EEP EEP I I I Q~Z m Q •ls/�J �O�l.
1 III III 1 w f EEP- -/����
• EEP EEP EEP EEP EO EOP 14 I ���((SS SS N (DEEP
I I m w Q=N= v
�i
34.30' A�� -2570 _ 8,059 SF I I ^I m=a
\ 3 I L0
I III III I \ EXISTING WELL AND I I cn w o
III II I I +� �N 3 ` APPURTENANCES, TO BE I I o Q
I I -
1 RELOCATED AS NEEDED. N U
CD
1 III III I o I +� 3 NW09'45"E 116.38' I I I z o U'
I 111 Ill 1 0 z / 3 V I I I I � of
111 111 / o� I I I ct I > C1
.� or- Cw
o / �( 3 j C I 30 - - o II II Vicinity Map ,� m L o
8,059 SF_ _ -2510 _ 1 N ,� �z ~ m o
o -Lo� � J owo
� z \ EXISTING IRRIGATION
II -
1/1 / 29,576 SF v_, I BOX, TO BE RELOCATED f u7
`o � = � �
I 111 ' 111 1 w I d AS NEEDED o
I III 111 I 00
O ,�' N � � QC)
I III 111 1 \ / l // 1 I c� � < � � Q
o m moo, z 4� o � wio
I III III I � \ N � � mazes
III i I a 0' 116.38' / I I �o oz
I II III z I y / N00'09'45"E 140.38' // 1 I `14 °' \ 1 ~ 2
� zz ¢
I I III l / w 00 NOT TO SCALE APGAR CREEK DR. a w g
_Lja APGAR CREEK DR. Q� ~O Q w
III III I w a I/ S \ \ ��s Ism z
JFm
J -
00
1 III I III w a b �\ O ° U' E SPRINGS CT 3 w zo Y o 0
III III I EXISTING GRAVITY ' 8,633 SF Cn I I o N o 0
III IRRIGATION BOX, TO BE `o I OND STONE ST. > m - N
I II aald aald aald aald aald 2iald aald ddld aald a?Jld aIMd ?Jald aald c
RETAINED AND PROTECTED I EXISTING IRRIGATION I a, :' I o m z z
III III 25�1- BOX, TO BE RELOCATED I m I I 3
c�i� z � CD
/2570, , SAS NEEDED 2s, o w I I McMILLAN RD. MCMILLAN RD. w � o c)
Ujoc) rw
Proj ect N
• \ / �� J - -II II - - - 3 Q Qo
III N00'09'45"E 300.0 • N00'09' 5"� m .00' ��, w
III I III I Fulfer Sub.No.4 Fulfer Sub.No.4 ^ Q� LOCatlOn Z m
III III
I III \\\ \ 71 rn \
1 11 \ \ �I i m I0
1 \\\ \\\ \
\ \\\ \ \\ w I I O
LEb
(0 L0
\ \\\
\\\X\ m
I I
C� C
II
- - - -
\ I I
FFFFT L
- - - - - - - - - - - - - - - - -
Notes
_ _ _ _ - _ _ _ = _ _ _ _-
1. THERE ARE NO POTENTIALLY HAZARDOUS AREAS. 14. THIS PROPERTY IS CURRENTLY ZONED R-8.
O U
N. Wild Goose Way 2. THERE ARE NO STREAMS, PONDS, LAKES, OR WETLANDS ON THIS 15. EXISTING USE: SINGLE FAMILY RESIDENCE. w
PROPERTY. CA o
16. CONTOUR INTERVAL: 2 FOOT DATUM: NAVD 88 ..-,
3. THERE ARE NO NATURAL DRAINAGE SWALES ON THIS PROPERTY. 17. THE PRIVATE DRIVE AREA SHOWN HEREON SHALL BE MAINTAINED BY THE j
Ld
Private Drive Cross Section Setback/ZoningTable Land Use Calculations Underground UtilityNote 4 AREAS ONTHERE ETHIS PROPERTY NO . 18. THIS DEVELOPMENT ANTICIPATES USING SUBSURFACE STORM WATER
NOT TO SCALE THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM 5. THIS PROPERTY IS NOT IN A FLOOD PLAIN AREA. DISPOSAL OF STORM WATER GENERATED FROM THE LOCAL ROAD SYSTEM
EXISTING ZONE R-8 DESCRIPTION AREA (ACRES) PERCENTAGE AND LANDS TRIBUTARY TO THE SYSTEM.
FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE 6. THERE ARE NO IDENTIFIED SHALLOW BEDROCK AREAS, UNSTABLE ROCK
24.0' PROJECT 2.75 100% SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND FORMATIONS, OR LANDSLIDE AREAS ON THIS PROPERTY. 19. PUBLIC UTILITIES ARE TO BE PROVIDED FROM THE PUBLIC UTILITY
MINIMUM LOT AREA - INTERIOR LOT 4,000 SF
RESIDENTIAL LOTS 1.69 61.4% UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, PROVIDERS FROM JOINT TRENCH ADJACENT TO THE PUBLIC ROADS.
FRONT YARD SETBACK TO GARAGE 20 FEET 7. THIS PROPERTY IS NOT IN AN AQUIFER RECHARGE AREA.
EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER SPECIFIC DESIGN CRITERIA WILL BE MET DURING THE CONSTRUCTION M
12.0' 12.0' PRIVATE DRIVE LOTS 0.39 14.3% N �;; 3
FRONT YARD SETBACK TO LIVING AREA 10 FEET DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN 8. NO UNSTABLE SOILS SUSCEPTIBLE TO EROSION EXISTING ON THIS APPROVAL PHASE OF THIS DEVELOPMENT. o �
ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES PROPERTY. ALL AREAS ARE SUITABLE FOR DEVELOPMENT.
REAR YARD SETBACK 04
12 FEET 20. THIS PARCEL LIES WITHIN THE "ZONE X" FLOODWAY PER FEMA MAP o z z o
3:1 TO 3:1 TO CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE 9. SANITARY SEWER SERVICE IS TO BE PROVIDED BY THE CITY OF BOISE. 16001C0143J, DATED JUNE 19, 2020. w
f- STREET SIDE YARD SETBACK 20 FEET RESIDENTIAL LOTS 4 FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT # o } J m z
2.00% MINIMUM 2.00% MINIMUM N < a a Z a
EXISTING EXISTING INTERIOR SIDE YARD SETBACK 5 FEET PRIVATE DRIVE LOTS 1 PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. DEVIATIONS 10. POTABLE WATER IS TO BE PROVIDED BY THE UNITED WATER. 21. THE FOLLOWING TAX PARCEL NUMBER IS INCLUDED WITHIN THIS a m= o c, o
GROUND GROUND MAXIMUM BUILDING HEIGHT 35 FEET RESIDENTIAL DENSITY 2.4 UNIT/ACRE MAY EXIST BETWEEN THE LOCATIONS SHOWN HEREON AND THEIR 11. PROPERTY LIES WITHIN THE NAMPA MERIDIAN IRRIGATION DISTRICT. SUBDIVISION: R2958270300. (4853 N. CHIMNEY PEAK AVE.) 41 �� z z J Y o w o Z o
MINIMUM STREET FRONTAGE 40 FEET ACTUAL LOCATION(S). 22. ALL COMMON DRIVEWAYS AND ALLEYS SHALL BE MAINTAINED AT ALL TIMES
J w� ¢� w� o> Q>
12. PROPERTY LIES WITHIN THE MERIDIAN CITY FIRE DISTRICT. FOR ACCESS BY FIRE, POLICE, AND EMAS AT ALL TIMES OF THE YEAR. N o
13. EXISTING IRRIGATION FACILITIES TO BE CONTINUED TO THEIR HISTORIC
2 1/2" OF ASPHALTIC CONCRETE DISCHARGE POINTS. SHEET NO:
SUB BASE - 10" OF PER I.S.P.W.C. SECTION 805.
6" MINUS PER BASE COURSE - 4" OF 3/4" Owner/Applicant I.S.P.W.C. SECTION 801. MINUS PER I.S.P.W.C. SECTION 802. COLTON YASINSKI 1 1 of 1 1
4853 N. CHIMNEY PEAK AVE.
MERIDIAN, ID 83646
Chimney Peak Subdivision
Turnaround Sketch
20,
ASPHALT p�
> I
EXISTING HOME,TO REMAIN 7----F
U
72'
O I a�
� ire
24' ASPHALT _ _ - _ _ _ _ 20' ASPHALT
115' —r- 125'
0
INSTALL "NO PARKING FIRE LANE"
SIGN PER APPENDIX D OF THE 2018
IFC AND INSTALLED PER ACHD
STANDARDS. (TYPICAL)
Q
G01URJ��
Note
ALL COMMON DRIVEWAYS AND ALLEYS SHALL BE
CENTURION ENGINEERS, INC. MAINTAINED AT ALL TIMES FOR ACCESS BY FIRE,
Consulting Engineers, Land Surveyors, Planners POLICE, AND EMAS AT ALL TIMES OF THE YEAR.
2323 S. Vista Ave. Ste. 206 1 Boise, ID 83705
208.343.3381 1 www.centengr.com
30 0 30
eVo NC HORIZONTAL SCALE: 1"=30'