Loading...
HomeMy WebLinkAboutPZ - Roof Plan /14 A501 4 X-2 C 7 SAVORY 5 I I' ry N W S MANAGEMENT 2 V �Y 1 J 8 N z 2 - �? O W N z W 3 U VALLEY ---- �� V P_va _ A131 W A131 TYP. D3 U. m 00 7 X-2 Q z Q 2 7 p oz _ 0 = o 6 7 2 1/2"/ 12" U A501 `0000 > w N CV V X-2 X-7 X-3 2 A131 CORE STATES GROUP 135 WATER STREET SUITE 201 NAPERVILLE,IL 60540 �(_7 630.413.1110 www.core-states.com SEAL 4 ROOF PLAN 1/2"= 1'-0" AM NORTH LVL BEAM - REFERENCE FIBER CEMENT PANEL WITH STRUCTURAL ATTACHMENT CLIP SYSTEM ROOF MEMBRANE FIBER CEMENT PANEL STACKER TRACK ATTACHED TO HAT HEAT WELDED LAP CHANNEL AND ANGLE BEYOND WRAP MEMBRANE ROOFING ISSUE DATE DESCRIPTION OVER LVL BEAM. z_ ROOF ASSEMBLY Ln HVAC UNIT BASE RAIL ROOF PLAN GENERAL NOTES t KEYNOTES 3 ROOF SCREENING DRAINAGE DETAIL ROOF CURB INSULATION 1. REFER TO SHELL STRUCTURAL DRAWINGS FOR ROOF FRAMING O NOT USED 1 1/2"= 1'-0" AND DETAILS FOR ROOF PENETRATIONS AND LOADING. CURB FASTENER AS 2. ROOF TOP HVAC UNITS AND CURBS ARE PROVIDED AS PART OF O SINGLE-PLY MEMBRANE ROOFING OVER RIGID ROOF INSULATION REQUIRED SHELL. AND ROOF SHEATHING; PROVIDE FLASHING AND COUNTER PROJECT INFORMATION (3) 2X4s ROOF ASSEMBLY 3. ALUMINUM EQUIPMENT STAND SUPPORTS MANUFACTURED BY FLASHING AT ALL NEW PENETRATIONS PER PER MANUFACTURER'S RECOMMENDATIONS FOR MECHANICALLY FASTENED SYSTEM PROJECT NO: SW-06SAL AVCOA CORPORATION OF FORT LAUDERDALE, FLORIDA OR DATE: 12/23/2021 APPROVED EQUAL. 4 RAILS AT 5'-0" EACH ANDS'-0" EACH WITH 2 2X8 O3 NEW MECHANICAL EQUIPMENT;SECURE TO TOP OF DECK PER SCALE: AS NOTED SUPPORTS EACH RAIL. 5-0" RAILS TO BE 31"APART AT STRUCTURAL PER MANUFACTURER'S REQUIREMENTS; PROVIDE CURB 1/2" OSB COOLER/FREEZER CONDENSERS AND 5'-0" RAILS W/SUPPORTS AND CRICKET AS REQUIRED FOR PROPER DRAINAGE;SEE MECHANICAL DRAWN BY: M.SCHNEIDER TO BE 24"APART AT ICE MACHINE CONDENSERS. STANDS SHALL CHECKED BY: M.PELINI 2X8 PROVIDE 18"MINIMUM CLEARANCE (48"O.C. AT ICE MAKER 4 PREFINISHED METAL SCUPPER AND DOWNSPOUT SUBDIVISION: TBD CONDENSERS) AND SHALL BE SIZED INSTALLED ACCORDING TO LOT, BLOCK: BLOCK A, LOT 15 > THE MANUFACTURER'S LOAD CHARTS AND PRINTED INSTALLATION DETAILS. CONTACT: 800-266-7212. O5 PROVIDE TAPPERED INSULATION TO SLOPE ROOF AS SHOWN TOWN PROJECT NO: TBD © 24"X 36"OPENING SHEET TITLE SLOPE O7 EXHAUST FAN VENT- REFERENCE MECHANICAL DRAWINGS FRAMING. REFERENCE ROOF PLAN STRUCTURAL DRAWINGS. ® DRAINAGE OPENING. LOCATE OVER DRAINAGE VALLEY. REFERENCE DETAIL. ROOF JOIST. REFERENCE a SANDWICH A PIECE OF 1/2" OSB BETWEEN (2) 2X8s. RIP ENTIRE BLOCK OF LUMBER AS NECESSARY TO ADJUST FOR STRUCTURAL SHEET NUMBER ROOF PITCH. MAINTAIN FULL DEPTH AT ONE END. ATTACH (3) 2X4s TO THE TOP AND (1) 2X8 TO THE BOTTOM. co o CONDENSER FAN CURB DETAIL HVAC UNIT ROOF CURB DETAIL Al 31 No 1 1/2"= 1 -0" 1 1/2"= 1'-0" N O N N