Loading...
HomeMy WebLinkAboutPZ - Landscape Plan 1 2 3 4 5 6 7 8 9 10 LANDSCAPE NOTES: I I NOTE: BACKFILL SHALL BE 100%TOPSOIL. -- -__ a_i__ --- 3 v NOTES: --- --- 1. REGULATIONS & STANDARDS REMOVE ALL TAGS, TWINE OR WATER SETTLE ALL PLANTINGS TO ---— 1.1. All contractor work shall be conducted in accordance with ISPWC Idaho 1. DO NOT DAMAGE OR CUT LEADER OTHER NON BIODEGRADABLE ENSURE PLANT ROOTBALL _ ( 2. DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. MATERIALS ATTACHED TO PLANT OR MAINTAINS 2" HEIGHT ABOVE I 3 3 STACK Ro ROCK Standard Public Works Construction), 2022 (or most recent published); and 3. TREE STAKING SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED ROOT MASS. EXISTING SOILS WHEN COMPLETE. I 3 City of Meridian, ID codes, standards and state and local regulations. FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT I LANDSCAPE 2. EXISTING CONDITIONS CONTRACTOR'S EXPENSE. 3 I I 3 I I 3 ARCHITECTURE 2.1. All utilities shall be located prior to construction and protected. Any damage 4. WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. & MASTER PLANNING to structures, utilities or concrete will be replaced at contractor's expense. 5. REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP.1 OF THE ROOTBALL. I 3 I 3 2.2. The site has many existing improvements such as underground utilities, 6. 5' DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3"OF MULCH MIN. DO 3 3y_ws-ws-ws ws-ws curb and gutter, light poles and sidewalks. NOT PLACE MULCH WITHIN 2"OF TRUNK OF TREE. I " s� i (208)345-0500 2.3. See Engineer's plans for information about existing features. ---- - ---- 3-3------------------------------------- ___ 404 S 8th St. #154 - - ------------ - - ----- - �------------ - ------------- --- ----- --, 2.3.1. Refer to civil plans for all existing and/or proposed drainage pipes & I - - - -- ---- Boise, ID 83702 I " EXISTING BUFFER TO REMAIN StackRockGrou com locations, utilities. Protect all drainage at all times, protect all utilities I--__ " I I p• at all times. _ _ ------- — ------ — --------------- ----- — —I — 3. GRADING & SITE PREPARATION 3 d - - - - - - R" 1 � WILLET C HOWARD, PLA 3.1. Prepare finish grades for planting b grubbing and removing weeds. If MULCH 2" MIN. IRR IRR RR IRR —IRR R RR RR RR IRF IRR R OFFICE: (208)345.0500 EMAIL: P g p g Y g g g TOP TWO STRUCTURAL AWAY FROM TRUNK - I I 3333 WILL@STACKROCKGROUP.COM necessary apply Round-Up (or equivalent herbicide), using a certified ROOTS: <3" BELOW TOP GRAFT VISIBLE ABOVE SOIL OF PLANT. 3 / I I I I I I www.STACKROCKGROUP.COM FOLD BURLAP FROM TOP applicator. Remove rocks and other materials over 2". OF ROOTBALL. LINE OF ROOT BALL DOWN 3" DEEP MULCH MIN. I I I I % a 3333 3.2. All gravel overprep to be removed and disposed of off site. INTO GROUND; SET TOP I R EP LOWEST STRUCTURAL 3 I I "" 3.3. Finish grade to be smooth transition to allow for entire site to be a natural SOIL LINE OF THE TOP OF OF BALL FLUSH WITH I W 3333 THE GRAPHICS AND DESIGNS � flowingspace. ROOT<5" BELOW TOP OF THE ROOT BALL AFTER ~ - + -m - --- -- -- - - - - - ROOT BALL FINISH GRADE LAWN OR PAVING --3 I I I I w I ON THIS SHEET A R E 3.4. Fine grade lawn areas to elevations set by Engineers plans with positive REMOVING EXCESS SOIL. R - - - - - - -- I J I" � -- - - - -I—I— DELIVERABLES THAT REMAIN drainage away from structures. 212 2-3"OF MULCH I TYP, EXISTING TREES I W 33 I AT ALL TIMES PROPERTY OF 3.5. Refer to Engineer's plans for grading information &for all drainage pipes BACKFILL MIX SEE I I PRESERVE & PROTECT I I I I III 3 STACK ROCK GROUP, INC. and locations. Protect and retain drainage at all times. NOTES AND 12"TO 18" FOR I I 333 3.6. No pooling or standing water will be accepted per industry standards. N SPECIFICATIONS. LARGER SHRUB I � I I W I I I I OI REPRODUCTION OR REUSE OF 4. SOILS AI ROOT BALLS, SEPTIC I I " 1333 i �I THIS PRODUCT CONTAINED 4.1. Lawn areas shall receive 12" min depth of screened topsoil. SOIL SAUCER>3" HIGH MAKE DEPTH MIN. I I I I I I W III 4" DEEPER THAN " HERE IN IS PROHIBITED 3 I I 3 3 3 3 I 4.2. All planter beds shall receive 18 REMOVE AT END OF ) WITHOUT THE WRITTEN DECK min depth of screened topsoil. BALL I " I "" PROJECT I I I I "I 4.3. Reuse of existing topsoil that has been stockpiled on site is permitted if: EXIST.HOUSE CONSENT OF STACK ROCK I W III" BALL AND BURLAP PLANT IF 3 I I F.F.=2560.65 I I 333 i G R O U P I N C 4.3.1. Topsoil is tested and analyzed to ensure a proper growing medium. Provide ( EXIST. I I W I I GROWN PLANT I3 additional amendments as determined by soil tests. CUT AND FOLD WIRE - CONTAINER- I I I DECK I 4.3.2. Topsoil is to be loose, friable sandy loam that is clean and free of toxic BASKET FROM TOP OF IG� 1 .. SOIL SURFACE WITH ROOTS LOOSENED AND I I I I " 333 ©2022 STACK " PULLED OUT TO PREVENT I 3 I I I materials, noxious weeds, weed seeds, rocks, grass or other foreign ROOTBALL COMPACT SOIL UNDER ROUGHENED TO I I I m I I ROCK GROUP, INC. ROOTBALL TO 90% PROCTOR. BIND WITH NEW SOILPLANT materials. FROM BECOMING ROOT I I I I " EXIST. BOUND) AWNING I I W 3333 4.3.3. Topsoil shall have a ph of 6.5 to 8.0. 3 I I I I III" I I I I I 4.3.4. If on site topsoil does not meet these minimum standards contractor is I I w 333 seals rI � I I PRELIMINARY ILL responsible fo providing approved imported topsoil or improving BALL & BURLAP TREE PLANTING SHRUB PLANTING I I I I III" onsite topsoil per the approval of the project manager. 1 - 2 - I I I _Ss s OF 3 3 3 3 4.4. If imported topsoil is used it must be from a local source and be screened 3/4"- 1'-0" 3293-01 1"- 1'-0" 329333-03 3 I I " I I I I I A free of any debris or foreign matter. Topsoil must not contain rocks, sticks, I I I I EXIST. I 3333 F C_�P lumps, or toxic matter and has a pH of 6.5-8.0. I I I DECK I I WIIII Ey 4.5. Smooth, compact, and fine grade topsoil in lawn areas to smooth and I I I I I I 1333 a uniform grade .5 below adjacent surfaces. I I I I I WIIII Z U 4.6. Amend all new plantings with 2 parts topsoil, 1 part compost. 5. LAWN AREAS I I I I II s LA-16733 LANDSCAPE REQUIREMENTS 5.1. Sodded lawn to be tall turf-type fescue, or approved other. I I I ° I 3333 WpI FO .23.20 P� 5.2. Sodded lawn to be regionally/locally harvested, lay sod within 24 hours of CODE REQUIREMENTS PER CITY CODE ` I I I I III ' /VDSCP.P� harvesting. c_ 3 v I 333 pl 5.3. Lay sod to form a solid mass with offset, tightly fitted joints on even grades. �\ - - - -�� - - - �- -_-NO TREES PER IRR LINE NOT FOR CONSTRUCTION 5.4. Any existing lawn that is damaged shall be replaced with sodded lawn of STREET BUFFER: / I ; / I W3333 �I the same type of existing lawn. *1 TREE PER 35LF 3 NOTE: IRRIGATION DITCH HAS BEEN ABANDONED," 5.5. All lawn areas adjacent to planter beds, gravel areas, or aggregate **EXISTING BUFFER ALONG CHERRY LANE TO REMAIN W SITE WILL BE IRRIGATED FROM EXISTING WELL 3 W W � WM y M� pathways shall have 4" black steel edging installed per manufacturer AND CITY WATER AS NEEDED, TYP LU recommendations. Other applications to be approved by owner and PERIMETER BUFFER: y landscape architect. *CANOPIES TO TOUCH WHERE POSSIBLE - I .c - C. III" W W 3333 5.6. Lawn adjacent to buildings, structures shall be a minimum of 18 **EAST BUFFER- NO TREES PER IRR LINE away from foundations. Lawn adjacent to fences or other screening elements shall be - - I W W I III I a minimum of 9" away. MINIMUM PLANT SIZES: F O O D O O O O I * ss ss 3333W� PLANT TYPE: MINIMUM SIZE 5.6.1. Install$" chips or other approved gravel mulch type in mow strip at a depth __1_ w ws of 3" over commercial grade weed barrier fabric installed per *EVERGREEN TREES: 6-10" HT. MIN. manufacturer recommendations. *ORNAMENTAL TREES: 2" CALIPER MIN. 5.7. Provide tree rings with a minimum 3' diameter around all trees located in *SHADE TREES: 2" CALIPER MIN. lawn, mulch type & installation/application to match all other planter beds. *WOODY SHRUBS: 2 GAL. MIN. 6. PLANTER BED MULCH I —E T 33 6.1. All planter beds to receive 3" depth of black&tan mini rock mulch or P LAN T SCHEDULE I I I I approved equal, submit for approval prior to placement. Install over I I I 3 3 TREES BOTANICAL/COMMON NAME CONT CAL SIZE QTY REMARKS commercial grade weed barrier fabric per manufacturer recommendations. • - I - 7. PLANTS I I 3 7.1. All plant material shall be installed per industry standards. Acer platanoides Parkway' /Norway Maple B&B 2" 5 CLASS II, 25'H x 25'W z I I I I I 7.2. All plant material shall meet or exceed the minimum federal standards as D o I I 333 Z regulated by ANSI z60.1, American Standard for Nursery Stock. Plants not w m I I I III J meeting these standards for quality, or plants determined to be unhealthy I I 333 by Owner's representative, will be rejected. 0 Betula nigra'BNMTF- TM/Dura Heat River Birch B&B 2" 3 35'h x 30'w • I I I I 3 � � 7.3. All Ball and Burlap trees to be installed per Balled and Burlapped planting J I p detail. All shrubs to be installed per detail. I .I ws ws " ws 7.4. Trees and shrubs over 30" shall not be planted within clear vision triangles. - L I 3 �/ 7.5. Fertilize all trees and shrubs with 'Agriform' planting tablets or approved • Quercus frainetto Schmidt /Forest Green Oak B&B 2" 2 50'h x 3o'w I - - - - - 5s_T5s- equal. Apply per manufacturers recommendations. I I I 3 I W 8. IRRIGATION EVERGREEN TREE BOTANICAL/COMMON NAME CONT CAL SIZE QTY REMARKS 8.1. Irrigation system shall be built to the following specifications: I I I p I O 8.2. Adhere to city codes when connecting to city water. 8.3. All irrigation material to be new with manufacturers'warranty fully intact. • a Pinus flexilis'Vanderwolf's Pyramid /Vanderwolf's Pyramid Pine B&B 8' H MIN 2 20'-25'tall & 10'-15'wide _ I 33 p I Q 8.4. Install outdoor rated controller in specified location on plan, in a lock box p with 2 keys. Coordinate with project manager and general contractor on SHRUBS BOTANICAL/COMMON NAME CONT FIELD2 SIZE QTY REMARKS 3 Z exact location. W - - - - — NO TREES PER IRR LINE 8.4.1. Controller to have On/Off rain switch or rain shut off device that does not Helictotrichon sempervirens 'Blue Oats' /Blue Oat Grass 2 gal 14 30"H x 30"W W I W W alter program. I 13 U 8.5. All remote control valves (including master control valve)to have flow -� - v ss-L ws 1 3 LLI control device. � Hydrangea paniculata 'Limelight' TM/Limelight Hydrangea 5 gal 8 4'H x 6'W I I I ss] 8.6. Irrigation system piping to be minimum class 200 PVC or approved equal, ws----, �53 —va va I 4 sleeves to be double the size of pipes located within, all wires to be yam, contained in separate sleeves 1-1/2" dia min. } Juniperus horizontalis'Wiltonii' /Blue Rug Juniper 5 gal 6 8"H x 8'W 3 8.7. All pipe above 3" caliper to be gasketed, with approved joint restraints at all I • I I I I _ I REVISIONS 45, TEE, ELL, 22, 11. I I I a MRK DATE Description 8.8. Use common trenching where possible.. Ligustrum x vicaryi 'NCLX1' TM/Golden Ticket Privet 5 gal 24 8'H x 8'W, Regular Pruning to 4'H &5'W 8.9. All PVC located under hardscapes to be schedule 40 PVC with same req's I I 3 ® ** ** as above. 8.10. All wires to be Paige wire 7350 or 7351 direct bury wire at a minimum of 12" Physocarpus opulifolius 'Diablo' /Diablo Ninebark 5 gal 20 6'H x 8'W I I 3 g rY � 1 below finished grade. I • 8.11. Connect mainline to point of connection in approximate location shown on Picea abies'Pusch' /Pusch Dwarf Norway Spruce 5 gal 24 3'H x 4'W I plan. 8.12. Contractor is responsible complying with all codes and paying all permits I I 3 necessary. O Rhamnus frangula 'Fine Line' /Fine Line Buchthorn 5 gal 38 7'H x 3'W I I I I p 8.13. Sprinkler heads shall have matched precipitation within each control circuit. I m Velocities shall not exceed 5 feet per second. I • 8.14. All drip irrigation to be buried 2" below finished grade. Rhus trilobata 'Gro Low' /Skunkbush Sumac 5 gal 10 30"H x 8'W I I �S s 3 JOB NO: 22-2252 8.15. Water schedule to be provided at a min of 80% evapotranspiration as 0 I O O k—ws ws ws ws IO�_ DATE: 01.12.2023 determined by the local ET. I 9 , I DRAWN BY: RS 8.16. Install all irrigation per irrigation drawings. utilize material specified or O Viburnum plicatum 'Mariesii' /Maries Doublefile Viburnum 5 gal 10 8'H x 10'W I I I 01 CHECKED BY: BH approved equal. I I I OI 8.17. Contractor shall confirm the static water pressure at least five days before construction begins and to contact the landscape architect in writing if the Yucca filamentosa'Golden Sword /Adam's Needle 3 gal 19 3'H x 4'W I ~ i - -- - - Q DRAWING TITLE pressure is below 80 psi. W W 8.18. If any discrepancies are found, then local codes shall prevail. 4 W W y RR eP WIRR� 9. CONTRACTOR RESPONSIBILITIES W W y W W W _ LANDSCAPE 9.1. Estimated quantities are shown for general reference only. Contractor shall EXISTING TREE, PRESERVE & PROTECT be responsible for all quantity estimates. PLAN 9.2. All plant material and workmanship shall be guaranteed for a period of one I / year beginning at the date of Acceptance by Owner. Replace all dead or unhealthy plant material immediately with same type and size at no cost to EXISTING TO REMAIN, PRESERVE & PROTECT UJ Owner. REPAIR/REPLACE ANY DAMAGED LANDSCAPE 0 20 40 60 feet Q 9.3. Landscape contractor to turn in as built drawings at the end of project. > p g p @ LAWN, TYP w Substantial completion will not be ranted until 2 copies 1 -20 scale are of turned in and approved by owner's representative. SODDED -TALL TURF TYPE FESCUE „ _ , SHEET NUMBER NORTH SCALE: 1 - 20 � 10. In the event of a discrepancy, notify the Landscape Architect immediately. O Ll00 0 Y U O Y U Q H 1 1 2 13 4 1 5 1 6 17 8 1 9 1 10