Loading...
HomeMy WebLinkAboutLochsa Falls Sub PP 02-009WHITE PETERSON WHITE, PETERSON, MORROW, GIGRAY, ROSSMAN, NYE & ROSSMAN, P.A. KEVM E. pMNS PHILIP A. PETERSON JuLa KLeIN FISCHER EIUCA S. Pxaues WM. F. GIORAY.JII ERIC S. RD$SMAN T. GUY HALLAM' TODD A. ROSSMAN D. SAMUEL JOHNSON DAVNM. SWARiLEY LAARY D. NOORE PAMELA J. TARLOW WILLLIM A. MORROW TERRENCE R.WH]TE** WILLIAM F. NICHOLS* MCHOLAS L. WOLLEN CHRISTDPHER S. NYE *Also admitted in OR *' Also adnntted in W A To: Staff Applicant Affected Property Owner(s) ATTORNEYS AT LAW 830 E. FIRST ST., SUITE 200 POST OAAICE Box1150 MERIDIAN, IDAHO 83680-1150 TEL (206)286-2499, FAx (206) 266'2501 E-MAIL: rvLw~whltepeterson.cam September 19, 2002 Re: Application Case No. PP-02-009 NAMPA OFFICE NAMPA, DAH083887--8402 TEL. (206)486-9272 FAX (206) 466}408 PLEASE REPLY TO MERIDIAN OFFICE RECEIVED SEP 19 2~2 City Of Meridian City Clerk Office FINDINGS AND RECOMMENDATIONS OF PLANNING AND ZONING COMMISSION Staff, Applicant and/or Affected Property Owner(s): Please note that these Findings and Recommendations of the Planning and Zoning Commission shall be presented to the City Council at the public hearing on the above referenced matter by the Planning and Zoning Administrator. Due to the volume of matters whrch the Ctty Council must decide, and to insure your position Is understood and clear, it is important to have a consistent format by which matters are presented at the public hearings before the City Council. The City Council strongly recommends: 1. That you take time to carefully review the Findings and Recommendations ofthe Planning and Zoning Commmsslon, and be prepazed to state your position on this application by addressing the Findings and Recommendatrons of the Planning and Zoning Commission; and 2. That you carefully complete (be sure it is legible) the Position Statement if you disagree with the Findings and Recommendations of the Planning and Zoning Commission. The Position Statement form for this application is available at the City Clerk's office. It is recommended that you prepare a Position Statement and deliver it to the City Clerk prior to the hearing, ifpossible. If that is not possible, please present your Position Statement to the Clty Council at the heanng, along with eight (8) coptes. The copies will be presented to the Mayor, Council, Planning and Zoning Administrator, Public Works and the City Attorney. Ifyou aze a part of a group, it is strongly recommended that one Position Statement be filled out for the group, which can be signed by the representative for the group. Very truly yours, City Attorney's Office Iy2:1WORI0MIMERIDIAN\MERIDIAN 75360M1FORM6\TRANSMITTAL.DOC BEFORE THE PLANNING AND ZONING COMMISSION IN THE MATTER OF THE REQUEST FOR PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION FARWEST LLC AND DANIEL GIBBON, Applicants Case No. PP - 02-009 RECOMMENDATION TO CITY COUNCIL The property is approximately 354.38 acres in size and is generally located south of Chinden Blvd., west of Linder, north of McMillan and east ofTen-Mile Road. 2. The owners of record of the subject property are Leroy E. Brandt, Elroy Brandt, Many Goldsmith, Sunjay Ray M.D., Daniel Gibson, Jr., and Justin and Tamra Martin. 3. Applicants are Farwest, LLC, and Daniel Gibson, Jr. 4. The subject property is currently zoned RUT by Ada County. There is, however, an application for Annexation and Zoning before the City Council wherein the Applicants request zoning of R-4. The zoning of R-4 is defined within the City of Meridian Zoning and Development Ordinance Section 11-7-2. 5. The subject property is within the city limits of the City of Meridian. 6. The entire parcel is included within the Meridian Urban Service Planning Area as defined in the Meridian Comprehensive Plan. The Applicant proposes to develop the subject property in the following manner: 856 Single Family Dwellings, 171 Multiple Family Dwellings, 11 Office Buildings, 1 Commercial Building, 1 City Park, 1 Private Park, and 1 Future Fire Station Lot. 8. There are no significant or scenic features of major importance that affect the consideration of this application. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 1 RECOMMENDATION The Meridian Planning and Zoning Commission hereby recommends to the City Council of the City of Meridian that they approve the Preliminary Plat as requested by the Applicant for the property described in the application, subject to the following: A. Adopt the Recommendations of the Planning and Zoning and Engineering staff as follows: Site Specific Comments 1. The Public Works Department is gathering sewer and water infonnation from the field a well as analyzing this project with computer models that were developed for our facility plans. It is anticipated that because of the phasing pattern proposed by the Applicant, that significant amounts of off-site sewer and water main extensions will be necessary. The Sewer Master Plan proposes the North Slough Trunk traversing through this proposed development. By starting the phasing on the opposite side of the section from where the North Slough Sewer Trunk begins traversing east (i.e. Ten Mile Road), the routing locks proposed roadway alignments into place. If the phasing plan is approved, the applicant will be required to construct water mains and the trunk line through the projects roadway system within the normal utility corridors. No service lines will be allowed in the off-site segments. Apnlicant will also be required to construct a permanent all- weather 14 foot-wide paved access road over any undeveloped seaanents within this nroiect, until such time as the public street is improved. At ultimate build-out, the sewer and water mains shall be located within the improved nublic ri hghtof- ~• 2. In accordance with Ordinance 12-13-10-8, Applicant shall construct detached sidewalks adjacent to Ten Mile Road, McMillan Road, and Linder Road. The minimum width of the parkway area between the curb and sidewalk is five (5) feet. Tree plantings within the parkways will be restricted to either Class I or Class II trees, as approved by the P&Z Department, through the detailed Final Plat review process. 3. The Applicant shall install the proposed ten foot (10') wide pathway along the south side of W. Cayuse Creek Drive (see pg. 2 of CUP application). 4. Fencing details shall be submitted with the Final Plat application. Fencing adjacent to pathways or the private park shall not be over three feet in height if constructed of a solid material, and shall no be more than 4 feet in height, if it is non-sight obscuring. 5. A detailed landscaping plan shall be submitted with the final plat application. The landscaping plan shall include the details for the proposed 30' wide pedestrian/ emergency vehicle access on Linder Road. 6. Performance specifications for the common area pressurized irrigation system shall be submitted with the Final Plat application. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 2 7. The phasing schedule may apply to the residential portions of the subdivision only. If the Applicant/ Developer determines that the office/ multi-family /commercial property can or should be developed in an order that is not consistent with the phasing schedule, they may request final plat approval of said phases in a no-sequential manner without revising the preliminary plat. All development, however, must be contiguous to a previously approved phase. 8. The sidewalk to be required as part of the aforementioned path system will be five feet (5') in width. General Comments 1. Please submit a copy of the Ada County Street Name Committee's final approval letter for the subdivision name, and the lot and block numbering. Make any corrections necessary to conform. 2. Coordinate fire hydrant placement with the City of Meridian Public Works Department. 3. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the Final Plat. 4. One-hundred watt, high pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/ or fire hydrants. 5. Underground pressurized irrigation must be provided to all landscaped areas on site. Due to the landscape area, primary water supply connection to the city's mains will not be allowed. Applicant shall be required to utilize any existing surface or well water for the primary source. Applicant has not indicated whether the pressurized irrigafion system within this development is to be owned and maintained by an association or an irrigation district. If the system is being proposed as a private system, plans and specifications for the irrigation system shall be reviewed by the Public Works department as part of the development plan review process, and a draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval. 6. Six-foot high, solid perimeter fencing shall be required adjacent to all existing agricultural land, unless otherwise agreed upon in writing by the Planning Director. No fencing will be permitted within the required landscape buffers. The Applicant shall address the type of fencing planned at the PBcZ Commission public hearing. Submit detailed fencing plans for review and approval with submittal of the Final Plat. All required fencing is to be in place prior to issuance of building permits. A letter of credit or cash will be required for these fences prior to signature on the final plat. Perimeter fencing shall be installed prior to obtaining building permits. 7. A detailed landscape plan for the common areas, including pathways and types of construction, shall be submitted for review and approval with the submittal of the final plat applications. The plan must include sizes and species of trees, shrubs, benning/ Swale details, and all proposed ground cover/ treatment. A letter of RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 3 credit or cash surety in the account of 110% will be required for all fencing, landscaping, pressurized irrigation, sanitary sewer, water, etc. prior to signature on the Final Plat. 8. All irrigation ditches, laterals, or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. The ditches to be piped should be shown on the site plans. Plans will need to be approved by the appropriate irrigation/ drainage district, or lateral users association, with written confirmation of said approval submitted to the Public Works Department. 9. Any existing domestic wells and/ or septic systems within this project will have to be removed from their domestic service per City Ordinance,Sections 9-1-4 and 9- 4-8. Wells maybe used for non-domestic purposes such as landscape irrigation. 10. Slopes within drainage lots are not to exceed a slope ratio of 3:1. B. Adopt the Recommendations of ACHD as follows: Site-Specific Conditions of Approval 1. Dedicate 48 feet of right-of -way from the centerline of Linder Road, Ten Mile Road, and McMillan Road abutting the parcel by means of a warranty deed. The right-of--way purchase and sale agreement and deed must be completed and signed by the Applicant prior to scheduling the final plat for signature by the ACHD Commission or prior to issuance of a building permit (or other required permits), whichever occurs first. Allow up to 30 business days to process the right-of--way dedication after receipt of all requested material. The Owner will be paid the fair market value of the right-of--way dedicated which is an addition to existing ACHD right-of--way if the Owner submits a letter of application to the impact fee administrator prior to breaking ground, in accordance with the ACHD Ordinance in effect at that time (currently Ordinance #195). 2. Construct a 5 foot concrete sidewalk abutting the property on McMillan Road, Ten Mile Road, and Linder Road. The sidewalk shall be constructed 2 feet within the new right-of--way. If the sidewalk is proposed to meander outside of the right- of-way, the applicant shall provide an easement to the District. 3. Construct a main entrance, North Goddard Creek Way, to intersect McMillan Road approximately 1,100 feet east of the west property line (approximately at the half-mile). 4. Construct a main entrance, West Cayuse Creek Drive, to intersect Linder Road located approximately 1,350 feet north of the south property line (approximately the half-mile). 5. Construct a main entrance, Wild Goose Drive, to intersect Linder Road at the south property line. 6. Construct a center turn lane on Linder Road for West Cayuse Creek Drive to provide a minimum of 100 feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 4 7. Construct a center turn lane on Linder Road for West Wild Goose Drive to provide a minimum of 100 feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the turn lane with District staff 8. Construct a center turn lane on North Goddard Creek Way to provide a minimum of 100 feet of storage with shadow tapers for both the approach and departure directions. Coordinate the design of the tum lane with District staff. 9. Construct right-tum deceleration lanes (tapers) on Linder Road for West Cayuse Creek Drive and West Wild Goose Drive. Coordinate the design of the taper with District staff. 10. Construct right-tum deceleration lanes (tapers) on McMillan Road for North Goddard Creek Way. Coordinate the design of the taper with District staff. 11. Construct the internal local residential roadways as a 33 foot street with curb, gutter, and 4-foot-wide detached concrete sidewallc within 50 feet ofright-of--way with parking on both sides of the roadway contingent upon approval from the Meridian Fire Department. 12. Construct North Dry Bar Avenue as a 40 foot street section with curb, gutter, and 5 foot concrete sidewalk within 54 feet ofright-of--way abutting the commercial development (approximately 350 feet). 13. Construct West Ballinger Way and West Wild Goose Drive as 36 foot street sections with curb, gutter, and 5 foot wide concrete sidewalks with no front-on housing. The access restrictions for these street segments shall be stated on the final plat. Parking shall be prohibited on these street segments. Coordinate the signage plan with District staff. 14. Construct West Cayuse Creek Drive, North Goddard Creek Way, North Lochsa Way as 29 foot street sections with vertical curb, gutter, and 5 foot sidewalk within 50 feet ofright-of--way. OR Construct West Cayuse Creek Drive, North Goddard Creek Way, North Lochsa Way as 33 foot street section with a 4 foot bike lane, curb, gutter, and 5 foot concrete sidewalk within 50 feet ofright-of--way. 15. Construct a 30 foot wide driveway located on McMillan Road approximately 250 feet east of the west property line which meets District policy and should be approved with this application. 16. Construct a 25 foot shared access driveway intersecting North Goddard Creek Way approximately 420 feet north of McMillan Road extending to the west property line. 17. Construct two shared driveways (one extending east; one extending west) located on North Dry Bar Avenue approximately 350 feet south of Chinden Boulevard. 18. Construct thirteen stub streets to the surrounding parcels. • The Applicant is proposing to construct West Apgar Drive to the east property line approximately 400 feet north of McMillan Road. • The Applicant is proposing to construct West Wapoot Court to the east property line approximately 1,100 feet north of McMillan Road. • The Applicant is proposing to construct Parachute Hill Avenue to the south property line approximately 600 feet east of the west property line. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDMSION - FARWEST LLC AND DANIEL GIBSON -Page 5 • The Applicant is proposing to construct North Chimney Peak Avenue to the south property line approximately 1,650 feet east of the west property line. • The Applicant is proposing to construct West Cedar Grove Street to the east property line approximately 650 feet north of the south property line. • The Applicant is proposing to construct North Gertie Place to the north property line approximately 100 feet west of the east property line. • The Applicant is proposing to construct West Boulder Bar Street to the west property line approximately 500 feet south of Chinden Boulevard. • The Applicant is proposing to construct West Tango Creek Street to the west property line approximately 1,025 feet south of Chinden Boulevard. • The Applicant is proposing to construct North Powell Creek Avenue to the north property line approximately 2,050 feet east of the west property line. • The Applicant is proposing to construct West Glade Creek Street to the west property line approximately 1,500 feet south of Chinden Boulevard. • The Applicant is proposing to construct West Anatole Street to the west property line approximately 2,350 feet north of McMillan Road. • The Applicant is proposing to construct West Whitehouse Street to the west property line approximately 1,800 feet north of McMillan Road. • The Applicant is proposing to construct West Divide Creek Street to the west property line approximately 1,025 feet north of McMillan Road. 19. Provide a paved temporary turnazound with a temporary easement provided to the District at the end of North Gertie Place, West Glade Creek Street and West Wapoot Court and a sign at the terminus of all of the stub streets stating that "THIS ROAD WILL BE EXTENDED IN THE FUTURE." Coordinate the sign plan for the stub street, and the design of the turnaround with District staff. 20. Any proposed landscape islands/ medians within the publicright-of--way dedicated by this plat shall be owned and maintained by a homeowners association. Notes of this are required on the final plat. 21. Construct one knuckle on North Goddazd Creek Way located approximately 700 feet north of McMillan Road. The island within the knuckle shall be constructed a minimum of 4 feet wide with a minimum area of 100 square feet and designed to safely channel traffic. The roadway around the traffic island shall maintain a minimum of a 29 foot street section. The design shall be reviewed and approved by ACHD's Planning and Development staff. 22. Construct a roundabout at the intersection of North Lochsa Way, North Goddard Creek Way and West Cayuse Creek Way with 21 foot street sections on either side of the center island. The Applicant is required to dedicate 54 feet of right-of- way plus the additional width of the island. Coordinate the size and design of the roundabout with traffic services staff. 23. Turnarounds shall be constructed to provide a minimum turning radius of 45 feet. The Applicant will be required to provide a minimum of a 29 foot street section on either side of any proposed center islands within the turnazounds. The medians shall be constructed a minimum of 4 feet wide to total a minimum of a 100 square foot azea. Dedicate 54 feet ofright-of--way plus the additional width of the median. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDMSION - FARWEST LLC AND DANIEL GIBBON -Page 6 Standard Conditions of Approval 1. Any existing irrigation facilities shall be relocated outside of the right-of--way. 2. All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 3. Replace any existing damaged curb, gutter, and sidewalk and any that maybe damaged during the construction of the proposed development. Contact Construction Services at 387-6280 (with file number) for details. 4. All design and construction shall be in accordance with the Ada County Highway District Policy Manual, ISPWC Standazds and approved supplements, Construction Services procedures and all applicable ACRD Ordinances unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 5. The Applicant shall submit revised plans for staff approval, prior to issuance of building permit (or other required permits), which incorporates any required design changes. 6. Construction, use, and property development shall be in conformance with all applicable requirements of the Ada County Highway District prior to District approval for occupancy. 7. Payment of applicable road impact fees is required prior to building construction in accordance with Ordinance #195, also known as Ada County Highway District Road Impact Fee Ordinance. 8. It is the responsibility of the Applicant to verify all existing utilities within the right-of--way. Existing utilities damaged by the Applicant shall be repaired by the Applicant at no cost to ACHD. The Applicant shall be required to call DIGLINE (1-800-342-1585) at least two full business days prior to breaking ground within ACHD right-of--way. The Applicant shall contact ACHD Traffic Operations 387- 6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 9. No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the Applicant of the Applicant's authorized representative and an authorized representative of the Ada County Highway District. The burden shall be upon the Applicant to obtain written confirmation of any change from the Ada County Highway District. 10. Any change by the Applicant in the planned use of the property which is the subject of this application, shall require the Applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the Applicant or its successors in interest advises the Highway District of its intent to change the planned use of the subject property unless awaiver/ variance of said requirements or other legal relief is granted pursuant to the law in effect at the time the change in use is sought. C. Adopt the Accommodations made by Farwest, LLC in ari August 15, 2002 memo entitled "Tony Moss" as follows, including amendments made by the Planning and Zoning Commission: RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 7 1. a. A park lot will be moved to the east of the Moss parcel. b. On Lots 11, 12, and 14 of Block 6 east of the Moss pazcel, Applicant agreed to a 25' peak building height to retain the view (one of the three lots will be an open lot). c. Applicant will provide large lots on the north and south of the Moss pazcel. d. Applicant will provide a common area on the west (Lot 6 Block 6), and agreed to retain Mr. Moss's plum trees on the east if possible. e. Applicant agreed to pipe any irrigation ditches contiguous to the Lochsa Falls property prior to the issuance of Final Plat. £ Applicant agreed to construct a water feature at the McMillan Road entryway. g. Applicant agreed to deed Lot 1, Block 6 to Mr. Moss and pave a driveway across this lot if Mr. Moss relinquishes his current access easement. h. Applicant agreed to coordinate boundary fencing with Mr. Moss consistent with the Lochsa Falls Subdivision. 2. The City is not aware of whether the accommodations, as amended by the Commission and approved by the Developer, have been approved by the Mosses. If the Mosses do approve the aforementioned list, then the accommodations shall be binding upon the Developer. If Mr. and Mrs. Moss do not agree to such accommodations as listed, the Developer will not be bound to such terms. 3. The Developer and the Mosses have negotiated a relinquishment of the Mosses' easement from Ustick Road to their pazcel of property. If the Mosses do not agree to relinquish such easement, the Developer shall be free to dedicate as a lot the land held in easement. D. Adopt the Meridian Fire Deparhnent Recommendations as follows: 1. One and two family dwellings will require afire-flow of 1,000 gallons perminute available for a duration of 2 hours to service the entire project: Fire hydrants shall be place an average of 400' apart. 2. Commercial and office occupancies will require afire-flow consistent with the Uniform Fire Code to service the proposed project. Fire hydrants shall be placed an average of 400' apart. 3. Multi-family residential on the site will require afire-flow of 1500 GPM plus the amount required by the fire sprinkler demand. 4. Acceptance of the water supply for fire protection will be y the Meridian Water Department. 5. Final approval of the fire hydrant locations shall be by the Meridian Fire Department. 6. All roads shall have a turning radius of 28' inside and 48' outside. 7. Insure that all yet undeveloped parcels are maintained free of combustible vegetation per section 1103.2.4 of the Uniform Fire Code. 8. All access roads within the project shall have a clear driving surface with a minimum width of 20' available at all times. Typical street width of 34' will be RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 8 allowed to have parking on both sides. The typical collector street with a width of 29' will be required to have restricted parking to only one side. Restricted parking will be required for Blocks 2, 58, 57, 20, 36, and 28. 9. Operational fire hydrants and temporary or permanent street signs are required before combustible construction begins. 10. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have a turnaround. 11. A minimum of two points of access will be required for any portion of the project, which serves more than 30 homes. 12. The proposed 876-lot subdivision with an estimated 2.9 residents per household would have a total estimated population of 2,540 residents at build out. The proposed multi-family lot has an estimated 171 units with a total estimated population of 495 residents at build out. The 11 office lots and 1 commercial lot will have an unknown transient population and will have an unlrnown impact on Meridian Fire Department call volumes. The Meridian Fire,Department has experienced 2069 responses in the year 2000 and 2251 calls for service in 2001. According to a report completed by Fire & Emergency Services Consulting Group in February of 2000 our requests for service are projected to reach 2800 in the year 2005 and 3800 by the year 2010. 13. The proposed project lies outside the five-minute response zone goal. Achievement of this goal is subject to budgetary constraints and is intended to enhance the probability of a favorable outcome on a request for Basic Life Support. The budget constraints are typically defined as capital outlay for facilities that are located within 1.5 miles from a given location and sufficient operational funds to staff the facilities. 14. The proposed site location of the Meridian Fire Station meets the general requirements of the Master Site Plan for fire station locations. The site appears to have met the minimum lot dimensions required for a satellite location. E. Adopt the Recommendations of the Central District Health Department as follows: The Applicant's central sewage and central water plans must be submitted to and approved by the Idaho Department of Health & Welfare, Division of Environmental Quality. 2. Run-off is not to create a mosquito breeding problem. Stormwater shall be pretreated through a grassy Swale prior to discharge to the subsurface to prevent impact to groundwater and surface water quality. 4. The Engineers and architects involved with the design of the subject project shall obtain current best management practices for stormwater disposal and design a stormwater management system that prevents groundwater and surface water degradation. RECOMMENDATION TO CITY COUNCIL OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 9 F. Adopt the Recommendations of Meridian Parks & Recreation Department as follows: 1. The Developer shall provide a minimum 25 acre park site adjacent to Ten Mile Road. The Developer would receive a credit of approximately $478,538.00 collected from impact fees within the Lochsa Falls Development only (Based upon 862 single family lots and 171 multi-family lots). The Commission supported this recommendation unanimously. The park would be developed through City General Funds and impact fees collected from other developments. 2. The Developer shall be responsible fora 14' wide hard surface pathway or section of parking lot over the utility easement running along the south boundary of the park site. The developer is responsible for coordinating the location of the easement with the Parks Department. G. Adopt the Recommendations of Idaho Power as follows: Idaho Power Company is unable to serve this application without significant system upgrades. The Applicant should contact the local Idaho Power Company Operations Center for details. The contact for this area is the Meridian Team, at 388-2021. H. Adopt the Recommendations of the Meridian Water Department as follows: Meridian Water recommends that this subdivision be supplied by two water mains. The main on Ten Mile Road needs to be extended down McMillan Road to the subdivision's east boundary. The main on Linder Road needs to be extended to the subdivision's north boundazy. The Public Water Department can recommend water main sizes. bto/Z:\WorkN~lN~leridianNAeridian 15360MV2ecommendadons\PP-02-0091-ochsaFalls.doc RECOMMENDATION TO CITY COUNCII. OF APPROVAL OF PRELIMINARY PLAT FOR LOCHSA FALLS SUBDIVISION - FARWEST LLC AND DANIEL GIBBON -Page 10