HomeMy WebLinkAboutC8.00 ACHD Roadway -Signal Plan V1UGP
UGP
UGP UGP
UGP
UGP UGP
UGP
UGP
UGP UGP UGP UGP
UGP
UGP
UGP
UGP UGP UGP
UGP UGP UGP
UGP UGP UGP UGP
UGP
UGP UGP
UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP
UGP
UGP UGP UGP
T T T T T T T T
T
T T
T
T T T
T
T T
T
T T T
T
T T
T
T
T T T T T
T
T T T T T T
T
T T
T
T T T
T
T T
T
T T T
T T
T
T T T
T
T T
T T
T
T
T
T
T
T
T
T
T
T
T
T T
T T T T T T T T T
UGP
UGP
UGP
G
G
G
G
G
G
G
G
G G
G G G G G G G
G
G
G
G
G G
T T
G G G G
G
G G
G
G
G G G G G G
G
G
G G
G
G
G G G
G
G G G G G G G G G G
T T
T T
T T T
T
T T
T
T T
T
T
T
T
T
T
UGP UGP UGP
UGP
T
T
T
T
T
T T
T
T T
T
T T T
T
T
SS
SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS
SS SS SS
W
W W W W W W
W
W
SS SS SS SS SS
SS
SS SS SS SS SS SS SS SS SS
SS SS SS
SS SS SS SS SS
SS
SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS
SS
OHP OHP OHP OHP OHP OHP
OHP
OHP OHP OHP
OHP
OHP OHP OHP
OHP
OHP OHP
OHP
OHP OHP OHP
OHP
OHP OHP OHP
OHP
OHP OHP OHP OHP
OHP
OHP
W W W
W
W W W
W
W W W W W W W W W W W W
W
W W W
W
W W W
W
W W W
W
W W W
W
W W
W W
W W
W W
W W
W
W W W
W W W W W W
W
W W
G G G
G
G
G
G
G
G G G G G G
G
G
G
G G G G G G G G
G
G
G
G G G G G G
G
G
G
G
G
G G G G G G
G
G
G
G
G
G G
E
E E
E
E
E
E
E
R/W R/W R/W 76.43' R/W R/W R/W
S
W
WV
WV
SAN
IV
IV
IRR
T
C
IV IV
IV
E
IV
E
E
E
IV
IRR
WV
IV
CO
RD
T
T T
T
E
E
T
E
E
WV
W W W W W
S
S
T
UGP
UGP
UGP
UGP
UGP
UGP
8''W
SS SS SS
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
R/W
R/W R/W R/W R/W R/W R/W
SAN
12''SD12''SD
12''SD 12''SD
12''SD
18''SD 18''SD
18''SD
SD
18''SD
18''SD18''SD
18''SD
MW
R/W R/W
133+00
134+00
135+00
R3-5R
30"x36"
R3-5R
30"x36"
2700
E OVERLAND RD
SNS
2600
2600
E OVERLAND RD
SNS
2700
WELLS AVE
SNS
WELLS AVE
SNS
R3-5R
30"x36"
S
S
16001500
15001600
EXISTING POLE B
COMBINATION SIGNAL & LUMINAIRE POLE
STA: 132+71.91, OFF: 49.37'R
EXISTING POLE HEIGHT: 35-FT
INSTALL SIGNAL MAST ARM: 45-FT
EXISTING LUMINAIRE MAST ARM: 15-FT
EXISTING POLE A
COMBINATION SIGNAL & LUMINAIRE POLE
STA: 133+68.25, OFF: 48.41'R
EXISTING POLE HEIGHT: 35-FT
INSTALL SIGNAL MAST ARM: 50-FT
EXISTING LUMINAIRE MAST ARM: 15-FT
RELOCATE POLE D
COMBINATION SIGNAL & LUMINAIRE POLE
STA: 133+50.86, OFF: 62.67'L
EXISTING POLE HEIGHT: 35-FT
INSTALL SIGNAL MAST ARM: 35-FT
EXISTING LUMINAIRE MAST ARM: 15-FT
TOP FOUNDATION EL: 2650.30
EXISTING POLE C
COMBINATION SIGNAL & LUMINAIRE POLE
STA: 132+71.34, OFF: 47.93'L
EXISTING POLE HEIGHT: 35-FT
INSTALL SIGNAL MAST ARM: 50-FT
EXISTING LUMINAIRE MAST ARM: 15-FT
REMOVE AND SALVAGE EXISTING POLE D
COMBINATION SIGNAL & LUMINAIRE POLE
STA: 133+73.21±, OFF: 53.19'L±
POLE HEIGHT: 35-FT
LUMINAIRE MAST ARM: 15-FT
INSTALL POLE E
PEDESTRIAN SIGNAL POLE
STA: 133+61.54, OFF: 55.04'L
POLE HEIGHT: 12-FT
TOP FOUNDATION EL: 2650.54
INSTALL POLE F
PEDESTRIAN PUSH BUTTON POLE
STA: 133+74.62, OFF: 43.31'R
POLE HEIGHT: 4-FT
TOP FOUNDATION EL: 2651.19
INSTALL POLE G
PEDESTRIAN PUSH BUTTON POLE
STA: 133+62.59, OFF: 43.20'R
POLE HEIGHT: 4-FT
TOP FOUNDATION EL: 2651.14
INSTALL POLE I
PEDESTRIAN PUSH BUTTON POLE
STA: 132+62.83, OFF: 42.72'R
POLE HEIGHT: 4-FT
TOP FOUNDATION EL: 2650.81
INSTALL POLE H
PEDESTRIAN PUSH BUTTON POLE
STA: 132+76.61, OFF: 42.85'R
POLE HEIGHT: 4-FT
TOP FOUNDATION EL: 2651.08
INSTALL POLE J
PEDESTRIAN SIGNAL POLE
STA: 132+77.40, OFF: 58.81'L
POLE HEIGHT: 12-FT
TOP FOUNDATION EL: 2650.32
20213
3 1 0 0 B R I S T O L S T R E E T , S U I T E 4 0 0
C O S T A M E S A , C A 9 2 6 2 6
W W W . N G G P A R T N E R S . C O M
T 9 4 9 . 7 5 6 . 0 8 1 8 F 9 4 9 . 7 5 6 . 0 1 4 5
A R C H I T E C T U R E ● P L A N N I N G ● I N T E R I O R S
REV DESCRIPTION DATE
2700 E. Overland Rd.
Meridian, ID 83642
SEASONS AT MERIDIAN
NEWMAN GARRISON + PARTNERS, INC
COPY RIGHT 2019 NEWMAN GARRISON + PARTNERS
MORGAN HOLDINGS &
STONE HILL
38 Glen Gary Dr., Ste. 200
Aspen, CO 81611
7301 Peak Dr., Ste. 200
Las Vegas, NV 89128
TLG PN: 120124
A DELTA A 07/22/2022
C8.00
ACHD Roadway -
Signal Plan
Traffic Signal Legend:
SIGNAL HEAD NUMBER
PROJECT NOTE NUMBER
CONDUIT RUN NUMBER
SIGNAL CABINET SIZE 6 TS2-1 WITH UPS CABINET AND BATTERY BACKUP SYSTEM & SERVICE PEDESTAL
JUNCTION BOX (TYPE S40/ADA)
JUNCTION BOX (TYPE S45/ADA)
SIGNAL HEAD WITH BACKPLATE
EMERGENCY PREEMPT DETECTOR
(2 CHANNELS ONLY PER DETECTOR)
SINGLE POINT DETECTION CAMERA
MAST-ARM MOUNTED SIGN
PEDESTRIAN SIGNAL HEAD
JUNCTION BOX (TYPE S45/ADA WITH RISER)
SPLICE VAULT
X
X
X
Signal Head Schedule:
FY
A
R
12"
12"
12"
G
A
R
12"
12"
12"
G 12"
Quadrant Diagram:
1. QUADRANT LOCATIONS AS SPECIFIED ON LUMINAIRE, SIGNAL POLE, PED BUTTON POLE OR SIGNS ARE
ESTABLISHED BASED ON THIS DIAGRAM. QUADRANTS RELATE TO PLAN ORIENTATION.
QUAD 4
QUAD 3
QUAD 2
QUAD 1
11
Sheet Notes:
1. ALL TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD).
2. REFER TO ACHD STANDARD TRAFFIC DETAILS (TS SERIES) FOR CONSTRUCTION DETAILS AND
INSTALLATION REQUIREMENTS.
3. THE LOCATIONS OF SIGNAL POLES, JUNCTION BOXES AND PEDESTRIAN POLES SHALL BE STAKED IN THE
FIELD FOR APPROVAL BY ACHD PRIOR TO INSTALLATION. REQUEST ACHD APPROVAL AT LEAST TWO (2)
WORKING DAYS PRIOR TO INSTALLATION.
4. CONDUIT LAYOUT SHOWN IS SCHEMATIC. THE CONTRACTOR SHALL MAINTAIN APPROPRIATE CLEARANCE
BETWEEN ADJACENT UTILITIES.
5. GROUND THE SIGNAL AND ILLUMINATION SYSTEM IN ACCORDANCE WITH THE CURRENT EDITION OF THE
N.E.C. AND THE ACHD TRAFFIC SUPPLEMENTAL PROVISIONS.
6. LOCATIONS OF EXISTING UNDERGROUND STRUCTURES AND UTILITIES SUCH AS PIPELINES, CONDUITS,
CABLES, ETC. SHOWN ON THE TRAFFIC SIGNAL PLANS ARE APPROXIMATE ONLY. IT IS NOT THE INTENT OF
THESE PLANS SHOWN THE EXACT LOCATION OF ALL UNDERGROUND UTILITIES AND STRUCTURES. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES WITH
THE RESPECTIVE OWNERS. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED AT
THE CONTRACTOR'S EXPENSE.
7. ALL VIDEO DETECTION ZONES WILL BE SET BY ACHD STAFF. CONTRACTOR SHALL CONTACT ACHD TRAFFIC
DEPARTMENT AT LEAST TWO (2) WORKING DAYS PRIOR TO VIDEO DETECTION PROGRAMMING.
8. NEW SIGNAL AND SERVICE CABINETS AND ALL ASSOCIATED EQUIPMENT TO BE SUPPLIED BY ACHD AT
CONTRACTOR/DEVELOPER EXPENSE. CONTRACTOR SHALL CONTACT ACHD TRAFFIC DEPARTMENT TO
COORDINATE THE SALVAGING, DISPOSAL, AND/OR TRANSFER OF ANY SIGNAL OR INTERCONNECT
EQUIPMENT.
9. TOP OF FOUNDATION ELEVATIONS FOR ALL POLES SHALL BE FIELD VERIFIED BY THE CONTRACTOR BASED
ON THE CONSTRUCTED FINISHED GROUND ELEVATIONS.
10. CONTRACTOR SHALL COORDINATE WITH IDAHO POWER AND SITE ELECTRICAL PLANS FOR SIGNAL POWER.
11. CONTRACTOR SHALL CONTACT MERIDIAN CITY FIRE DEPARTMENT (208)888-1234 FOR PREEMPTION
EQUIPMENT.
Phase Diagram:
Ø1
Ø2
Ø3
31
51 71
21 22
41 42
Ø4
Ø5
Ø6
Ø7
Ø8
61 62
81 82
Horizontal Scale:
0 10' 20'
1" = 10'
ACHD Roadway-Signal Plan
22
52
31
81 83
12
61
62
63
71
43 41
21
24
23
63
5
16" PEDESTRIAN
COUNTDOWN
21P 22P
41P 42P
61P 62P
81P 82P
81P
82P
21P
22P
61P
62P
41P
42P
12 52
51
11
PRESERVE AND PROTECT
EXISTING OVERHEAD UTILITIES
PRESERVE AND PROTECT
EXISTING OVERHEAD UTILITIES
PRESERVE AND PROTECT
EXISTING OVERHEAD UTILITIES
07-22-2022 (100% CD) CD SET
PPB
PPB
PPB
PPB
PPB PPB
PPB
42
43
23
24
82
83
PPB ON EXTENSION
A
A
0 8 / 0 3 / 2 2
08/03/2022
09/27/22
FPS-2022-0022